• Title/Summary/Keyword: Deterioration diagnostic

Search Result 142, Processing Time 0.03 seconds

A Study on the Influence of Harmonics in Power System Voltage on Arrester Diagnostics and its Compensation (피뢰기 열화진단에 있어 전원 고조파의 영향과 보정에 관한 연구)

  • Kim, Il-Kwon;Song, Jae-Yong;Han, Ju-Seop;Kil, Gyung-Suk;Rhyu, Keel-Soo;Cho, Han-Goo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.493-497
    • /
    • 2005
  • This paper dealt with the influence of harmonic voltages on arrester diagnostics and its compensation method by using a designed Pspice arrester model. A pure sinusoidal voltage and its 3$^{rd}$ harmonic voltage were applied to the model, and the leakage current components were analyzed. The simulation results have shown that the peak value of resistive leakage current depends not only on the phase of the 3$^{rd}$ harmonic voltage but also on the magnitude of it. In this paper, an approximated 5$^{th}$ order polynomial formula by the Least-Square-Technique was derived, and correction factors which compensate the error caused by the 3$^{rd}$ harmonic voltage were calculated.

Pulmonic stenosis corrected by balloon valvuloplasty in a Maltese dog

  • Lee, Seung-Gon;Moon, Hyeong-Sun;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.3
    • /
    • pp.333-336
    • /
    • 2007
  • A 6-month-old intact male Maltese dog (2.5 kg of body weight) was presented with the primary complaint of heart murmur and exercise intolerance. Diagnostic studies revealed severe pulmonic stenosis. Since the pressure gradient in stenotic pulmonic valve area was higher than 200 mmHg (maximum flow velocity = 7.1 m/s), the dog was underwent balloon valvuloplasty. With this procedure, the peak pulmonic velocity was reduced to 3.0 m/s (PG = 36 mmHg). Periodic re-evaluations performed in monthly interval revealed no further deterioration even after 4 month of procedure. This is the first case report of pulmonic stenosis fixed by non-surgical balloon valvuloplasty in Korea.

Deterioration Diagnostic of Film Capacitor included LCL Filter in Grid-connected Three-phase PWM Converter (계통연계형 3상 PWM 컨버터에서 LCL필터의 필름 커패시터 열화 진단)

  • Kim, Jang-sik;Im, Won-sang;Kim, Jang-mok;Oh, Hyung-Shic;Choi, Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.186-187
    • /
    • 2011
  • 3상 PWM 컨버터에서 LCL필터 필름 커패시터는 Self-healing 메커니즘에 의해 열화가 진행되며, 이는 시스템의 필터성능과 역률 저하로 이어진다. 따라서 계통측 커패시터의 고장을 판단하고 교체시기를 결정하는 것이 필요하다. 본 논문에서는 정전용량의 80%에 해당하는 공진주파수를 한 주기 동안 주입하였을 때 나타나는 응답의 변화를 통해 커패시터의 열화고장진단 알고리즘을 제안하였다.

  • PDF

Selection of Priority for Revitalization by Analyzing Rural House Type (농촌주택 유형분석을 통한 재생우선순위 도출)

  • Park, Gil-Beom;Park, Jun-Mo;Kim, Ok-Kyue;Bang, Se-Ra
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.174-175
    • /
    • 2014
  • A Rural house in Chungcheong area have been variety of matters, rapid deterioration of house and incomplete of maintenance control, that is represented lack of durability heating from lack of heat insulation property, health worsening form use of toxic substance and so on. For farmers who did not know where to repair and how to repair, they are urgently needed measures of standard and basis that is to realize a condition of rural house. Accordingly, this study drew major matters and priority for revitalization through analysis of type of rural house from research on the actual condition in order to develope of diagnostic criteria of rural house.

  • PDF

Detection and Location of Partial Discharge in Oil Filled Transformer

  • Lee, Seung-Whan;Oh, Hak-Joon;Chung, Chan-Soo;Yun, Man-Soo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.98.3-98
    • /
    • 2001
  • The research for detecting of insulating deterioration in transformer has been studied from long ago. Analysis method of combustible gas, which is included in insulating oil, has been widely used in detection of transformer pre-fault detection due to the effectiveness of its method. Recently the fault effect of the large transformer is very critical in a power system, therefore the on-line monitoring and diagnostic system is needed. In addition, the more accurate method of detecting a Partial Discharge (PD) location should be developed. For preventive maintenance against discharge failures, it is important not only to detect the discharges, but also to accurately estimate their positions. However ...

  • PDF

Development of Diagnostic Device for Internal Degradation in Distribution Line Using NDT Mathod (NDT 기법을 이용한 가공배전선로 내부 열화 진단장치 개발)

  • Hyun, Deuk-Chang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.8
    • /
    • pp.539-543
    • /
    • 2015
  • At present, the development of a detection device in order to prevent accidents due to wire deterioration in the distribution lines is required. Distribution line is not possible to check the internal state in a normal way because it is covered with the coating. Accordingly, various eddy current techniques that is the non-destructive test (NDT) techniques have been applied to solve this problem. In this paper, we have seen examining the characteristic change of the eddy current sensor according to the simplified shape of the sensor in order to solve the problems for the simplified shape that is generated when the simulation for the shape of the eddy current sensor.

Change of Properties by Environment Conditions in Aged ACSR Overhead Conductor (환경적 요인에 의한 노후 가공송전선의 특성변화)

  • Kim Shang-Shu;Kim Byung-Geol;Jang Tae-In;Kang Ji-Won;Lee Dong-Il;Min Byung-Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.3
    • /
    • pp.287-291
    • /
    • 2006
  • This paper describes mechanical and electric properties of ACSR $410\;mm^2$ conductor from many of older overhead conductor. Samples of conductors itemized two division according to operation sector, green area, salt and pollution area. Samples of conductors operated various environment conditions have undergone laboratory metallurigical investigation and tensile strength torsional ductility and electrical performance. The steel core were found to have retained their original properties to a large degree in both tensile strength and the number of turns to failure. On the other hand the aluminum conductor showed reductions in tensile strength. To determine the remaining useful life of aged conductor, an unacceptable deterioration level has to established for each diagnostic procedure.

Mitral Valve Dysplasia in a Maltese Dog

  • Jin, Yoo-Seong;Kim, Su-Jeong;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.33 no.6
    • /
    • pp.368-371
    • /
    • 2016
  • A four month-old intact female Maltese (weighing 1.8 kg) was present with major complaints of severe coughing and dyspnea. Diagnostic imaging studies revealed abnormally elongated chordae tendineae attached to anterior leaflet and shortened chordae tendineae attached to posterior leaflet of mitral valve causing mitral insufficiency and regurgitant blood flow into left atrium, indicating congenital mitral valve dysplasia. Therapy was directed to control existing clinical signs and to prevent further deterioration of cardiac enlargement using conventional cardiac medications. The dog is currently survived and being monitored at regular interval. This is the first case report describing mitral valve dysplasia causing mitral insufficiency of dog in Korea.

A study on the fault diagnosis system for Induction motor using current signal analysis (전류신호 분석을 통한 유도전동기 고장진단시스템 연구)

  • Byun, Yeun-Sub;Jang, Dong-Uk;Park, Hyun-June;Wang, Jong-Bae;Lee, Byung-Song
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.19-21
    • /
    • 2001
  • Induction motors are a critical component of many industrial machines and are frequently integrated in commercial equipment. The many economical losses and the deterioration of system reliability might be caused by the failure of induction motors in industrial field. Based on the reliability and cost competitiveness of driving system(motors), the faults detection and diagnosis of system is considered very important factors. In order to perform the faults detection and diagnosis of motors, the vibration monitoring method and motor current signature analysis (MCSA) method are emphasized. In this paper, MCSA method is used for induction motor fault diagnosis. This method analyzes the motor's supply current, since this diagnoses the motor's condition. The diagnostic system is constructed by using LabVIEW of National Instruments.

  • PDF

Fault diagnosis system of induction motor using artificial neural network (인공신경망을 이용한 유도전동기고장진단)

  • Byun, Yeun-Sub;Wang, Jong-Bae;Kim, Jong-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2222-2224
    • /
    • 2002
  • Induction motors are critical components of many industrial machines and are frequently integrated in commercial equipment. The heavy economical losses and the deterioration of system reliability might be caused by the failure of induction motors in industrial field. Based on the reliability and cost competitiveness of driving system (motors), the faults detection and diagnosis of system is considered very important factors. In order to perform the faults detection and diagnosis of motors, the vibration monitoring method and motor current signature analysis (MCSA) method are emphasized. In this paper, MCSA method are used for induction motor fault diagnosis. This method analyzes the motors supply current. since this diagnoses faults of the motor. The diagnostic algorithm is based on the artificial neural network, and the diagnosis system is programmed by using LabVIEW and MATLAB.

  • PDF