• Title/Summary/Keyword: Deteriorated Power Equipments

Search Result 8, Processing Time 0.023 seconds

A Consideration of the Expected Service Life Cycles of Electrical Equipments in Buildings (자가용 전기설비 권장 사용기간에 대한 고찰)

  • Jung, Jong-Wook;Kim, Sun-Gu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.131-137
    • /
    • 2010
  • This paper considers and suggests the life cycle of the power equipments installed in buildings. The target equipments were divided into 5 groups by a couple of conditions, and a theoretical consideration and domestic foreign case studies were carried out. As a result, the most appropriate life cycles and monitoring periods were suggested for each group. The suggested results are expected to practically help the field electricians determine whether they have to replace the deteriorated equipments or not.

Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment (전자파 검출에 의한 전력기기 On-Line 열화 측정시스템 개발)

  • Kang, C.W.;Choi, G.S.;Lee, Y.S.;Kim, C.W.;Kang, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1664-1666
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

Development of on-line system using electromagnetic wave for diagnosis of deteriorated power equipment in enclosed switchboard (전자파를 이용한 폐쇄배전반내 전력기기의 열화 온라인 진단시스템 개발)

  • Kang, C.W.;Choi, G.S.;Lee, Y.S.;Kang, D.S.;Kim, J.C.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.178-181
    • /
    • 2001
  • This paper presents the development of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise. Power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector, and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

A study on the Effects of Load Current for Lifetime of Cable Systems (부하 전류가 케이블의 수명에 미치는 영향에 대한 연구)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.4
    • /
    • pp.205-209
    • /
    • 2015
  • The economic losses resulted from the accident in the power cables at the power station is not only huge but also requires a great amount of time and expenses to restore to the former condition. In order to prevent these, it is necessary to invent and apply a technique to expect and prevent the accidents. In order to measure insulation resistances of power cables in operation, we derived the relations between load current and temperature. By analyzing data obtained from our measuring equipments, we showed the expected time to change deteriorated cables before accident occurs. We present a result of our study on the effects of the load current on lifetime of 6.6 kV cable systems in operation. With the current flowing through the load of the cable a heat is generated reducing the lifetime of the cable. In order to find out the effect of load current on the lifetime of cable systems, we applied the lifetime theory to the development of two equipments to measure insulation resistance and current of cable systems in operation.

Decomposition of Hazardous Gaseous Substances by Discharge Plasma (방전 프라즈마 화학반응을 이용한 유해물질의 분해)

  • 우인성;황명환;산외번장
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.79-83
    • /
    • 1996
  • In this study, in attempt to develop a new application technique of discharge plasma, we employed a kind of discharging method called SPCP ( short for Surface discharge induced Plasma Chemical Process). Applications of SPCP have been widely used for years. Compact ozonizers to deodorize household equipments like refrigerators we a part of such applications. We took advantages of the compactness and durability of the SPCP electrode to set up an experimental apparatus for decompositing vapor of aromatic hydrocarbons such as toluene, benzene and xylenes, which are major substances given off In painting or washing processes and aggravate working conditions. Results obtained from this study are summarized as follows. 1) Aromatic hydrocarbon vapors of up to 2,000ppm were almost thoroughly decomposed at the flow rate of 4ℓ/min or lower under the discharge with electric power of 400 Watts. 2) In dry air, as the decomposition progresses, tar-like substance deposits on the discharging areas, which deteriorated the decomposition rate in the end. This substance, however, was almost thoroughly removed by keeping discharge in dry air containing no solvent vapor.

  • PDF

A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station (화력 발전소 고전압 케이블 접속재의 On-Line 직류 누설 전류 시스템 개발과 진단 Factor에 관한 연구)

  • Park, Sung-Hee;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.187-193
    • /
    • 2018
  • There has been a gradual increase in the demand for the electric power in Korea. In order to meet the demand, power station should have technical functions with increased effectiveness. When accident happens in electric machinery at power stations, huge amount of economic losses and mulfunction of equipments occur. One of the accidents is a deteriorated cables operating power stations. In order to prevent cable accident in advance, we should monitor the insulation status of the cable. Cable accidents are resulting from the junctions. We have developed and installed a device in order to identify the status of junction part of power cable at Korea Western Power Co., Ltd.. We performed an accurate diagnosis for the stable utilization of junctions where the accidents occurs most frequently, and to increase the reliability. In this paper, we present the concepts of our device and the method of monitoring diagnosis for the stable use of junctions at cables predicting the life time of cables by analyzing the data obtained by the device. We also present the hardware aspect of the device we have developed.

Active Control of a High-Speed Pantograph using LQ-Servo Controller

  • Shin, Seung-Kwon;Song, Young-Soo;Eum, Ki-Young;Koo, Dong-Hoe
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1173-1177
    • /
    • 2004
  • The high investment is necessary for the new high speed lines. So the KRRI was interested in the possibility of upgrading the existing line in order to speed up the train in the conventional lines. The tilting train system has been developed because the reconstruction of railway for the cant compensation costs very high. The purpose of the tilting system is to compensate the centrifugal acceleration in order to reduce the lateral acceleration of the passenger at high speed on the curves.The pantograph of the tilting train is indispensable in order to supply the electrification equipments with power in safe. The dynamic interaction between the pantograph and the overhead catenary system causes the variation of the contact force and the contact force variation can cause contact losses, arcing and sparking. If the spark happens between the pantograph and the overhead catenary system, the EMI(electro magnetic interface) and noises may occur. After all, the quality of current collection is deteriorated. This paper deals with the active control of pantograph and presents the LQ-servo controller to reduce the contact force variation.

  • PDF

Design of Active Pantograph Controller (능동 판토그래프 제어기 설계에 관한 연구)

  • Ko Tae-Hwan;Um Ju-Hwan;Eum Ki-Young;Shin Seung-Kwon
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.4
    • /
    • pp.361-366
    • /
    • 2005
  • The high investment is necessary for the new high speed lines. So the KRRI has been interested in the possibility of upgrading the existing line in order to speed up the train in the conventional lines. The pantograph in train is indispensable in order to supply the electrification equipments with power in safe. The pantograph and the overhead wire form a dynamic coupled system and they affect each other through the contact force. Unfortunately, as the operational speed of a train increases, the vibration of the pantograph and the overhead wire also increases. This may lead to a zero contact force between the pantograph head and the overhead wire, which can results in the loss of contact, arching and abrasion. If the arching and spark happen between the pantograph and the overhead catenary system, the EMI(electro magnetic interface) and noises may occur. After all, the quality of current collection is deteriorated. This paper describes the dynamic response between the pantograph and catenary system by the numerical simulations and presents the LQ-servo controller to reduce the contact force variation