• 제목/요약/키워드: Detector sensitivity

검색결과 428건 처리시간 0.027초

누설전류에 의한 ZnO피뢰기의 열화진단장치 개발 (Development of deterioration arrester detector by leakage current)

  • 오정환;이영길;김재철;한민구;오계환;이복규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.74-76
    • /
    • 1995
  • In this paper, the results of development of arrester leakage current detector using micro computer are described. This detector is based on harmonic analysis of the leakage current by FFT. The change of leakage current is the recognized measure of deterioration. For low sensitivity to disturbance, this device used optical fiber. This will be a great benefit of detecting deterioration ZnO arrester.

  • PDF

시차 굴절률 측정에 의한 실시간 글루코오스 모니터링 (Real-time Monitoring of Glucose Using a Differential Refractive Index Detector)

  • 정진갑;이명희;최은경
    • 한국염색가공학회지
    • /
    • 제16권2호
    • /
    • pp.47-51
    • /
    • 2004
  • A differential refractive index detector was used for monitoring glucose contents in textile processing solutions. The sensitivity of the device was high enough to measure 0.05% aqueous glucose solution that could not be measured by normal refractive index measurement. The device was set to monitor glucose concentration continuously in real time by measuring differential refractive index and calibrated by standard glucose solutions in a range of 0.1 to 1.0%. The possibility of industrial application of the device was demonstrated by real-time monitoring of glucose concentration in textile processing solutions such as desizing bath and cellulase treatment bath. Both of solutions contained glucose as a major degraded product. The device would be able to control the weight loss of cellulosic fiber during cellulase treatment since the amount of degraded products in a processing bath is proportional to its weight loss.

원료수송용 벨트컨베이어의 철편인식 장치 개발에 관한 연구 (A Study on Development of Metal Detector on Belt Conveyor in Material Plant)

  • 유재상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 B
    • /
    • pp.714-716
    • /
    • 1997
  • In order to prevent the belt from being damaged by metal pieces, we developed multicoil-type metal detection system. This detects the presence of belt clips and position of metal pieces in ores being transported on conveyor belt. In this research, our coil sensor of multicoil-type metal detection system is divided into two parts, exciting part (transmitter coil) and sensing part composed of two receiver coils. Each receiver coil has several coils in the direction of belt width. Multicoil-type metal detection system is operated by supplying a transmitter coil with electric power resources to generate magnetic field, and then the change of magnetic flux resulted from a metal piece on the conveyor be a is induced into sensing coils. We can prevent detector from failing to catch metal pieces due to high threshold level produced by steel belt clips and male the sensitivity of belt-width direction uniform by using multicoil-type metal detection system. Besides, this developed system can recognize precise position and size of metal piece. The experiments shows that our multicoil-type metal detection system has better performances than the conventional metal piece detector.

  • PDF

컴퓨터를 이용한 피뢰기 누설전류 분석장치 개발 (Development of arrester leakage current detector using computer)

  • 이영길;오정환;김재철;한민구;오계환;이복규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.631-633
    • /
    • 1995
  • In this paper, the results of development of arrester leakage current detector using micro computer are described. This detector is based on harmonic analysis of the leakage current by FFT. For low sensitivity to disturbance, this device used optical fiber. This will be a great benefit of detecting deterioration ZnO arrester.

  • PDF

Near-Infrared Light Propagation in an Adult Head Model with Refractive Index Mismatch

  • Kim, Seung-Hwan;Lee, Jae-Hoon
    • ETRI Journal
    • /
    • 제27권4호
    • /
    • pp.377-384
    • /
    • 2005
  • We investigate near-infrared light (NIR) propagation in a model of an adult head using an extensive Monte Carlo (MC) simulation. The adult head model is a four-layered slab which consists of a surface layer, a cerebrospinal fluid layer, a gray-matter layer, and a white-matter layer. We study the effects of a refractive index mismatch on the model, calculating the intensity of detected light, mean flight time, and partial mean flight time of each layer for various refractive indices of the cerebrospinal fluid layer as functions of source-detector spacing. The Monte Carlo simulation shows that the refractive index mismatch presents very rich results including rapidly decaying intensity of detected light and a peak and cross-over in the partial mean flight time with source-detector spacing. We also investigate spatial sensitivity profiles at various source-detector spacings, discussing the index mismatch effect on the model.

  • PDF

FID를 이용한 수중의 TOC 분석법 (Determination of Total Organic Carbon in Water by Flame Ionization Detector)

  • 박만기;한대석;임병연
    • 약학회지
    • /
    • 제22권3호
    • /
    • pp.157-162
    • /
    • 1978
  • Total organic carbon(TOC) can be determined by means of combustion and flame ionization detector. The principle of string method is that a sample acidified to pH2 and transferred into combustion tube by string is oxidized with air. Another combustion tube method is that organic compounds are oxidized in the combustion tube charged with CuO and cobalt asbestos after the acidified sample is injected directly by microsyringe. Carbon dioxide evolved was reduced under specially treated nickel catalyst and hydrogen, the methane produced was detected by flame ionization detector. Linear relationship was found between concentration and the peak height by the string method. The peak area in the case of combustion tube method is in the range of 1-200ppm. The coefficient of variation by string method was 2.3% and that by combustion tube method was 1.8%. The lower detectable limit was about 10mol. Advantages of the latter are simplicity, sensitivity and reproducibility. TOC in contineous stream can also be determined automatically by means of the string method.

  • PDF

Design and construction of a new ultraviolet sensor using CsI deposition in the ionization chamber

  • Souri, R.;Negarestani, A.;Souri, S.;Farzan, M.;Mahani, M.
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.751-757
    • /
    • 2018
  • In this article, a UV sensor that is an appropriate tool for fire detection has been designed and constructed. The structure of this UV sensor is an air-filled single-wire detector that is able to operate under normal air condition. A reflective CsI photocathode is installed at the end of the sensor chamber to generate photoelectrons in the ion chamber. An electric current is produced by accelerating photoelectrons to the anode in the electric field. The detector is able to measure the intensity of the incident UV rays whenever the current is sufficiently high. Therefore, the sensitivity coefficient of this sensor is found to be $7.67{\times}10^{-6}V/photons/sec$.

정온식 열감지기의 응답시간지수 및 작동시간 (Response Time Index and Operation Time of Fixed Temperature Heat Detector)

  • 류호철;태순호;이병곤
    • 한국화재소방학회논문지
    • /
    • 제7권1호
    • /
    • pp.11-16
    • /
    • 1993
  • Fixed temperature heat detectors that respond to the heat generated in fire plume and alarm when the temperature reaches a specified point, give a great influences to the loss of life and property according to their reaction sensitivity. In this study, hot wind tunnel tests and compartment fire experiments were performed to investigate the response time and temperature of fixed temperature heat detector. As a result, simple equations were derived which can be predicted the response time and temperature of the fixed temperature heat detector for the ramp type fire. Also other useful data, such as the effective temperature, time constant, response time index(RTI) were obtained.

  • PDF

IN SITU STRESS MEASUREMENTS OF Co-BASED MULTILAYER FILMS

  • Kim, Young-Suk;Shin, Sung-Chul
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.470-473
    • /
    • 1995
  • We have constructed an apparatus for in sity measurement of stress of the film prepared by sputtering using an optical noncontact displacement detector. A Change of the gap distance between the detector and the substrate, caused by stress of a deposited film, was detected by a corresponding change of the reflectivity. The sensitivity of the displacement detector was $5.9\;{\mu}V/{\AA}$ and thus, it was turned out to be good enough to detect stress caused by deposition of a monoatomic layer. The apparatus was applied to in situ stress measurements of Co/X(X=Pd or Pt) multilayer thin films prepared on the glass substrates by dc magnetron sputtering. At the very beginning of the deposition, both Co and X sublayers have subjected to their own intrinsic stresses. However, when the film was thicker than about $100{\AA}$, constant tensile stress in the Co sublayer and compressive stress in the X sublayer were observed, which is believed to be related to a lattice mismatch between the matching planes of Co and X.

  • PDF

볼렌즈를 이용한 광학식 진직도 측정시스템 (Optical Straightness Measuring System Using a Ball-lens)

  • 이민호;조남규
    • 한국정밀공학회지
    • /
    • 제31권12호
    • /
    • pp.1133-1139
    • /
    • 2014
  • This paper proposes a simple method to improve a sensitivity of a straightness measurement system for a linear stage, which is applied to a system based on a geometric optic method. An optical system for this method is composed of a corner-cube retro-reflector, a ball-lens and a twodimensional position sensitive detector (2D PSD). The effectiveness of the proposed method was examined theoretically, and verified experimentally using a prototype measurement system. The results show that the measuring sensitivity was dependent on the size of the ball-lens and the setup position of PSD from the ball-lens, and that the proposed method is efficient method to improve the measuring sensitivity.