A Polycrystalline CdZnTe Film and Its X-ray Response Characteristics for Digital Radiography

  • Kim, Jae-Hyung;Park, Chang-Hee;Kang, Sang-Sik;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • 제4권5호
    • /
    • pp.15-18
    • /
    • 2003
  • The Cd$\_$1-x/Zn$\_$x/Te film was produced by thermal evaporation for the flat-panel X-ray detector. The crystal structure and the surface morphology of poly crystalline Cd$\_$1-x/Zn$\_$x/Te film were examined using XRD and SEM, respectively. The leakage current and X-ray sensitivity of the fabricated films were measured to analyze the X-ray response characteristic of Zn in a polycrystalline CdZnTe thin film. The leakage current and the output charge density of Cd$\_$0.7/Zn$\_$0.3/Te thin film were measured to 0.3 1nA/$\textrm{cm}^2$ and 260 pC/$\textrm{cm}^2$ at an applied voltage of 2.5 V/$\mu\textrm{m}$, respectively. Experimental results showed that the increase of Zn doping rates in Cd$\_$1-x/Zn$\_$x/Te detectors reduced the leakage current and improved the X-ray sensitivity significantly. The leakage current was drastically diminished by the formation of thin parylene layer in the Cd$\_$0.7/Zn$\_$0.3/Te detector.

CdTe 와 ZnS:AgCl phosphor를 이용한 Hybrid형 X선 검출기의 특성연구 (The characteristic study of hybrid X-ray detector using CdTe and Zns:AgCl phosphor)

  • 석대우;강상식;김진영;박지군;문치웅;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 센서 박막재료 반도체 세라믹
    • /
    • pp.71-74
    • /
    • 2003
  • Photoconductor for direct detection fiat-panel imager present a great materials challenge, since their requirement include high X-ray absorption, ionization and charge collection, low leakage current and large area deposition, CdTe is practical material. We report studies of detector sensitivity, That is an CdTe with $5{\mu}m$ thickness on glass. That is hybrid layer of depositting ZnS:AgCl phosphor with $100{\mu}m$ on CdTe. The leakage current of hybrid is similar to it of a-Se, but photocurrent is larger than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF

균형상살 검출 알고리즘에서 검출과 관련된 설계변수의 민감도 해석 몇 최적화 (Sensitivity Analysis and Optimization of Design Variables Related to an Algorithm for Loss of Balance Detection)

  • 고병규;김광훈;손권
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권1호
    • /
    • pp.7-14
    • /
    • 2011
  • This study suggested an optimized algorithm for detecting the loss of balance(LOB) in the seated position. And the sensitivity analysis was performed in order to identify the role of each design variable in the algorithm. The LOB algorithm consisted of data processing of measured signals, an internal model of the central nervous system and a control error anomaly(CEA) detector. This study optimized design variables of a CEA detector to obtain improved values of the success rate(SR) of detecting the LOB and the margin time(MT) provided for preventing the falling. Nine healthy adult volunteers were involved in the experiments. All the subjects were asked to balance their body in a predescribed seated posture with the rear legs of a four-legged wooden chair. The ground reaction force from the right leg was measured from the force plate while the accelerations of the chair and the head were measured from a couple of piezoelectric accelerometers. The measured data were processed to predict the LOB using a detection algorithm. Variables S2, h2 and hd are related to the detector: S2 represents a data selecting window, h2 a time shift and hd an operating period of the LOB detection algorithm. S2 was varied from 0.1 to 10 sec with an increment of 0.1 sec, and both h2 and hd were varied from 0.01 to 1.0 sec with an increment of 0.01 sec. It was found that the SR and MT were increased by up to 9.7% and 0.497 sec comparing with the previously published case when the values of S2, h2 and hd were set to 4.5, 0.3 and 0.2 sec, respectively. Also the results of sensitivity analysis showed that S2 and h2 had considerable influence on the SR while these variables were not so sensitive to the MT.

휴대용 연기감도시험기 개발에 관한 연구 (A study on the Development of Smoke Detector Sensitivity Test Equipment)

  • 김형권;권성필;윤헌주;사공성호
    • 한국화재소방학회논문지
    • /
    • 제23권5호
    • /
    • pp.125-132
    • /
    • 2009
  • 본 연구는 자동화재탐지설비의 신뢰도 증진 및 국민의 안전 확보를 위한 정밀한 점검기구의 개발에 기여하기 위해 현장에 설치되어 있는 연기감지기를 검정기술기준과 동일한 시험내용으로 현장에서 성능 시험을 실시할 수 있는 시험기를 개발하고자 하였다. 그 결과 연기발생원으로 종이를 사용하고 히터를 40초 이내에 $400^{\circ}C$로 가열하여 시험이 가능하며, 광전식 연기감지센서를 통해 0~25%/m 연기농도의 측정 및 제어와 Fan의 rpm조절로 20~40cm/sec의 일정풍속 제어가 가능한 현장에서 좀 더 표준화되고 정밀한 성능시험이 가능한 휴대용 연기감도시험기를 개발하였다.

영상화재감지기 시험과 설치기준에 관한 연구 (A Study on the Test and Installation Standards of the Video Fire Detector)

  • 이정현;백동현
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.1-5
    • /
    • 2016
  • 본 논문은 영상화재감지기(Video Fire Detector)의 시험 및 설치기준에 관한 연구로서 FM Approvals, UL, ISO7240 및 NFPA 72 기준들을 서로 비교분석하여 국가화재안전기준 203 (NFSC 203)에 반영되어야 할 기준들을 제안하였다. 영상화재감지기의 시험과 관계된 FM Approvals 기준에는 연기형, 불꽃형으로 분류되고 비화재보시험이 있었으나 UL 기준에는 연기형만 제시되어 있었다. 외국 기준인 ISO 7240에서는 화재현상 검출유형 등 6가지를, NFPA 72에서는 화재현상 검출유형 등 3가지를 조사하였다. CCTV 설치 표준공법에서는 영상화재감지기의 설치기준에 필요한 항목이 15가지가 있었으며 설치방법에 따라 각 분야별 기준이 제시되어 있었다. 영상화재감지기 적용을 위해서는 감지기 시험항목 중 용어의 정의, 감지기의 구분, 구조 및 기능에 관련항목을 삽입하고 감도조정, 비화재보방지, 주위온도시험, 유효감지거리 및 감도와 시야각, 노화시험, 살수시험, 내화시험의 7개 항목의 적용이 필요하다. 현장 설치를 위해서는 국가화재안전기준 203 (NFSC 203)에 작동환경 및 조도기준을 설정하고 음향장치, 표시등의 설치거리 등의 기준을 삽입하여야 한다.

Optimization of Dual Layer Phoswich Detector for Small Animal PET using Monte Carlo Simulation

  • Y.H. Chung;Park, Y.;G. Cho;Y.S. Choe;Lee, K.H.;Kim, S.E.;Kim, B.T.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.44-44
    • /
    • 2003
  • As a basic measurement tool in the areas of animal models of human disease, gene expression and therapy, and drug discovery and development, small animal PET imaging is being used increasingly. An ideal small animal PET should have high sensitivity and high and uniform resolution across the field of view to achieve high image quality. However, the combination of long narrow pixellated crystal array and small ring diameter of small animal PET leads to the degradation of spatial resolution for the source located at off center. This degradation of resolution can be improved by determining the depth of interaction (DOI) in the crystal and by taking into account the information in sorting the coincident events. Among a number of 001 identification schemes, dual layer phsowich detector has been widely investigated by many research groups due to its practicability and effectiveness on extracting DOI information. However, the effects of each crystal length composing dual layer phoswich detector on DOI measurements and image qualities were not fully characterized. In order to minimize the DOI effect, the length of each layer of phoswich detector should be optimized. The aim of this study was to perform simulations using a simulation tool, GATE to design the optimum lengths of crystals composing a dual layer phoswich detector. The simulated small PET system employed LSO front layer LuYAP back layer phoswich detector modules and the module consisted of 8${\times}$8 arrays of dual layer crystals with 2 mm ${\times}$ 2 mm sensitive area coupled to a Hamamatsu R7600 00 M64 PSPMT. Sensitivities and variation of radial resolutions were simulated by varying the length of LSO front layer from 0 to 10 mm while the total length (LSO + LuYAP) was fixed to 20 mm for 10 cm diameter ring scanner. The radial resolution uniformity was markedly improved by using DOI information. There existed the optimal lengths of crystal layers to minimize the variation of radial resolutions. In 10 cm ring scanner configuration, the radial resolution was kept below 3.4 mm over 8 cm FOV while the sensitivity was higher than 7.4% for LSO 5 mm : LuYAP 15 mm phoswich detector. In this study, the optimal length of dual layer phoswich detector was derived to achieve high and uniform radial resolution.

  • PDF

레이저 거리 측정기용 광 검출기 수신 감도 실시간 측정 시스템 구현 (Implementation of the Real-time Measurement System of Receiver Sensitivity for a Laser Range Finder)

  • 이영주
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.108-111
    • /
    • 2016
  • We propose the method for measuring sensitivity of optical receiver of a long-range laser range finder in real-time. The sensitivity of the detector can be calculated using the detected voltage of the reference sensor, the area of the reference sensor and the transmittance ratio of neutral density filters. To evaluate the performance of the proposed method, we implemented a system and performed experiments. As a result, this system can be measured from 2nW to $113{\mu}W$. With this system, we measured the sensitivity of 37nW and 7nW with PIN PD and APD sample, respectively. This system has the advantage for the performance test of an optical sensor module in the long-range laser range finder.

상부 Au 전극 면적 Size에 따른 PbI2 필름의 전기적 특성 평가

  • 명주연;박정은;김대국;김교태;조규석;오경민;남상희
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.374-374
    • /
    • 2014
  • 의료용 X-ray는 과거 analog 방식과, 연구가 진행 중이며 현재 많이 사용되고 있는 digital 방식으로 나누어진다. 최근, 광도전체와 형광체 기반의 flat panel X-ray detector의 발전에 따른 상용화가 이루어지고 있으며, 많은 발전 가능성이 제기되고 있다. flat panel X-ray detector 검출방식은 direct method (직접 방식)와 indirect method (간접 방식)로 나누어진다. 본 연구는 일반적으로 상용화 되어있는 amorphous seleinum (비정질 셀레늄)의 큰 일함수에 의한 저 해상력이라는 단점을 보완하기 위해, 작은 일함수를 가지는 물질을 사용하여, 영상을 얻을 시에 높은 해상력으로 표현할 수 있도록 하고, 원자번호가 높은 물질을 사용하여 X-ray 흡수율을 높일 수 있도록 기존 direct method에 많이 사용되고 있는 amorphous seleinum 기반 digital X-ray detector가 아닌, 이러한 장점을 충족시킬 수 있는 PbI2 물질 층을 사용하여 시편을 제작 하였다. PbI2를 같은 두께로 올린 후, 물질 층 상부에 Au 전극 면적을 다른 size로 제작한 시편으로 X-ray에 노출 시켰다. 이는 상부 전극 size 차이에 따른 신호 차이를 측정하여 전기적 특성을 평가하기 위한 것이다. 전도성을 띠고 있는 ITO (Indium - Tin - Oxide) glass를 이용하여 screen printing 방법으로 제작하였다. PbI2층을 약 160~180 um두께, $3cm{\times}3cm$ size로 5개 제작하였으며, 상부 전극으로는 Au를 진공 증착 시켰다. 상부 전극 size는 각각 시편 5개에 $0.5cm{\times}0.5cm$, $1cm{\times}1cm$, $1.5cm{\times}1.5cm$, $2cm{\times}2cm$, $2.5cm{\times}2.5cm$로 PbI2 물질 층 중앙에 증착 시켰다. 이러한 설정으로 X-ray 노출 시 관찰할 수 있는 PbI2의 전기적인 특성을 평가할 수 있었다. 관전압을 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp, 140 kVp로 설정하고, 관전류는 100 mA로 설정하였으며, Dark current, Sensitivity를 측정하였다. Dark current와 Sensitivity를 측정한 뒤, 그 값을 이용하여 SNR (신호 대 잡음 비)값을 구해보았다.실험 결과 단위면적당 signal과 SNR을 분석할 수 있었다. 80 kVp로 기준을 잡고 결과 값을 보면 $0.5cm{\times}0.5cm$ 시편에서 2.92 nC/cm2, $2.5cm{\times}2.5cm$ 시편에서 0.84 nC/cm2로 상부 전극 크기가 작을수록 더 좋은 신호를 측정할 수 있었다. 똑같은 기준에서 SNR을 계산 해 보았을 때, $0.5cm{\times}0.5cm$ 시편에서 6.46, $2.5cm{\times}2.5cm$ 시편에서 1.91로 SNR역시 상부 전극 크기가 작을수록 더 큰 값을 확인할 수 있었다. 이러한 결과는 edge-effect의 영향으로 인해 나온 결과라고 할 수 있다. 이러한 실험 결과, detector 제작 시, 같은 물질을 사용하여 더 높은 효율을 내기 위해서는 큰 size의 상부 전극 보다는 작은 size의 상부 전극을 증착 시키는 것이 전기적 특성을 더욱 효율적으로 평가할 수 있을 것이라고 사료된다.

  • PDF

극초단파(Microwave)를 이용한 흰개미 탐지기술 적용연구 (Study on the Adaption Technique for Detection of Termites using Microwave)

  • 김대운;정선혜;이상환;정용재
    • 보존과학회지
    • /
    • 제26권1호
    • /
    • pp.77-83
    • /
    • 2010
  • 국내에 서식하는 지중흰개미는 목재 내부에 공동화 현상이 발생되어 붕괴가 일어나기 직전까지도 외관상 특별한 변화가 발견되지 않는다. 이러한 흰개미의 활성을 비파괴적으로 측정하는 기술은 현재 국내에 적용된 사례가 없었다. 따라서 본 연구는 극초단파 탐지 장비(Termatrac, Australia)를 이용하여 목조 문화재의 비파괴 진단 기술을 정립하고자 한다. 연구 결과, 소나무의 경우 16cm(민감도 5, 6), 느티나무와 Douglas fir의 경우 17cm(민감도 5, 6)까지 측정이 가능하여 국내 대부분의 목조 건축물에 적용이 가능할 것으로 판단되었다. 현장조사 결과 전국 목조건축물 231동 중 33.8%가 흰개미에 의한 손상을 입었으며, 7.8%인 총 18개 건물에서 흰개미 가해가 진행 중인 것을 확인할 수 있었다. 이와 같은 결과를 통해 목조 문화재의 비파괴 분석법으로서 적용이 가능할 것이라 예상된다.

반도체 검출기를 이용한 Hybrid 전치증폭기형 전자식 개인선량계 개발 (Development of Electronic Personal Dosimeter with Hybrid Preamplifier using Semiconductor Detector)

  • 이봉재;김봉환;장시영;김종수;노승용
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.51-57
    • /
    • 2002
  • 반도체 검출기를 이용하여 Hybrid 전치증폭기를 갖는 전자식 개인선량계를 설계 제작하고, 방사선 검출 반응특성과 기계적 및 주변 환경 요건에 따른 각종 성능을 평가하였다. $^{137}Cs$ 감마 방사선을 이용한 방사선 조사 시험결과 감도는 $3.8\;cps/Gy{\cdot}h^{-1}$이고, $10{\mu}Sv{\sim}4Sv$ 범위의 선량당량 조사시 선량계의 지시값은 오차 8%이하에서 선형성이 잘 유지되었다. 방향의존성을 ${\pm}60^{\circ}$ 이내에서 4%이하이며, ISO 기준선장에 의한 에너지 반응영역은 $60{\sim}1,250\;keV$로 나타났으며, IEC 61526에 의한 선량계의 성능검사시 9개 영역의 시험항목에 대한 국제기준을 만족하였다.