• Title/Summary/Keyword: Detective

Search Result 154, Processing Time 0.026 seconds

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

The Development of Pattern Classification for Inner Defects in Semiconductor Packages by Self-Organizing Map (자기조직화 지도를 이용한 반도체 패키지 내부결함의 패턴분류 알고리즘 개발)

  • 김재열;윤성운;김훈조;김창현;양동조;송경석
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.2
    • /
    • pp.65-70
    • /
    • 2003
  • In this study, researchers developed the estimative algorithm for artificial defect in semiconductor packages and performed it by pattern recognition technology. For this purpose, the estimative algorithm was included that researchers made software with MATLAB. The software consists of some procedures including ultrasonic image acquisition, equalization filtering, Self-Organizing Map and Backpropagation Neural Network. Self-organizing Map and Backpropagation Neural Network are belong to methods of Neural Networks. And the pattern recognition technology has applied to classify three kinds of detective patterns in semiconductor packages : Crack, Delamination and Normal. According to the results, we were confirmed that estimative algerian was provided the recognition rates of 75.7% (for Crack) and 83.4% (for Delamination) and 87.2 % (for Normal).

Comparative Effect of ${\gamma}$-Irradiation and Ozone Treatment for the Improvement of Hygienic Quality of Dried-Angelica Keiskei Koidz Powder (신선초 분말의 위생화를 위한 오존처리와 감미선 조사와의 비교 효과)

  • 변명우;육홍선;김정옥;김종군;이현자
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.2
    • /
    • pp.111-116
    • /
    • 1997
  • For the purpose of improving hygienic quality of dried-Angelica Keiskei Koidz powder, the effect of ozone treatment and gamma irradiation on the microbial decontamination and physicochemical properties were investigated. Gamma irradiation at 5 to 7.5 kGy resulted in sterilizing total aerobic bacteria, molds and coliforms below detective levels, while ozone treatment for 8 hours up to 18 ppm did not sufficiently eliminate the total aerobic bacteria of the sample. The physicochemical properties of the sample were not changed by gamma irradiation up to 7.5 kGy, whereas, ozone treatment caused remarkable changes in pH, TBA value, chlorophyll, carotenoid and fatty acid compositions. Therefore, this investigation demonstrated conclusively that gamma irradiation was more effective than ozone treatment for decontaminating and sterilizing the dried-Angelica Keiskei Koidz powder, with minimal effect on the physicochemical properties analyzed.

  • PDF

A Study on the Tool Life Detection System in Cutting Process. (절삭가공중의 공구수명검출 시스템 개발에 관한 연구)

  • 김정두;최종순
    • Journal of the Korean Professional Engineers Association
    • /
    • v.21 no.4
    • /
    • pp.6-11
    • /
    • 1988
  • The study on the progress of automatic machining system has been active centering at the CNC machine tools recently to lead the applied production technology like unmaned machining to the practical level, and to make these application more efficient, they require detective method for tool wear and breakage while machining. In this study chiefly on turning, first derive cutting force about the tool surface by the cutting resistant sensor and with which change into electric signal and compare with the standards to make the tool life detection system to let know the tool life and study its application; the cutting resistance detected by the cutting resistant sensor has increased to the level of standards, the measuring system which can decide whether we change tools on the basis of comperative circuit is shown to be very reliable model for cutting tool life detection system.

  • PDF

A Study on the Algorithm for Fault Discrimination in Transmission Lines using Advanced Computational Intelligence(ACI) (ACI 기법을 이용한 송전선로 고장 종류 판별에 관한 연구)

  • Park Jae Hong;Lee Jong Beom
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.619-621
    • /
    • 2004
  • This paper presents the rapid and accurate algorithm for fault discrimination in transmission lines. When faults occur in transmission lines, fault discrimination is very important. If high impedance faults occur in transmission lines, it cannot be detected by overcurrent relays. The method using current and voltage cannot discriminate high impedance fault. Because of this reason this paper uses voltage and zero sequence current, and the proposed algorithm uses fuzzy logic method. This algorithm uses voltage and zero sequence current per period in case of faults. Single line ground fault and three-phase fault can be detective using voltage. Two-line ground fault and line to line fault and high impedance can be detected using zero sequence current. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

Basic Study of the Improvement of PSD Output by Inclined Light Input (PSD의 출력특성향상을 위한 경사 입력광의 특성해석에 대한 기본연구)

  • Kweon, Hyun-Kyu;Park, Chang-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.4
    • /
    • pp.53-58
    • /
    • 2010
  • In this paper, the output characteristics of PSD(Position Sensetive Detector) used in measurement system are described. Most of the precision measurment systems are accomplished by a laser diode(LD), a photo diode(PD) and PSD(Position Sensetive Detector), which are used in reflection of mirror or projection of infrared spectrometer. But it is especially restricted by resolution of PD and PSD in nano-measurement. A new inclined light methods into the PSD are employed in the surface measurement system for increasing the resolution. As the results, we can know that the output characteristics of detective senser (PSD) become more than 2 or 3 times by changing inclined angle(range: 5 degree) compared with common angle. In addition, the experiment results are confirmed that the change of inclined angle is not affecting to the linearity and repeating.

Generation of Baculovirus Expression Vector Using Detective Autographa California Nuclear Polyhedrosis Virus Genome Maintained in Escherichia coli for $Occ^{+}$ Virus Production

  • Je, Yeon-Ho;Chang, Jin-Hee;Roh, Jong-Yul;Jin, Byung-Rae
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.2 no.2
    • /
    • pp.155-160
    • /
    • 2001
  • We have generated a novel baculovirus genome which can be maintained in Escherichia coli that facilitates the rapid and efficient generation of recombinant baculovirus expression vectors. To make $Occ^{+}$ recombinant expression vectors, polyhedrin gene under the control of p10 promoter was inserted to bAcGOZA and this genome was designated bApGOZA. As in bAcGOZA, bApGOZA lacks a portion of the essential ORF1629 gene, but includes a mini-F replicon and selectable kanamycin-resistance marker, This occasion-producing activity of bApGOZA can be used very conveniently for its oral infectivity to insect larvae in mass production of foreign protein and insecticides.

  • PDF

Identification and Antibiotics Susceptibility of Enterobacteriaceae Isolated from Feces of Wild Mammals in Choniu Zoo (동물원의 야생포유류 분변에서 분리한 장내세균의 동정과 약제감수성)

  • 송회종;윤창용;김성훈;채효석;도흥기;허부흥
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.263-267
    • /
    • 1997
  • Eighty-seven strains of Enterobacteriaceae isolated from feces of wild mammals in Choniu zoo were tested for their biochemical reaction and susceptibility to 19 antibiotics or chemicals by using disc diffusion test and/or Microscan Walkway 40/96. Out of 87 isolates, Enterobacteriaceae (44), Hafinia alvei (9), Citrobacterfreundi (5) and Proteus vulgaris (5) were frequently detected. The detective frequency of Enterobacteriaceae in animals classified by their eating pattern was higher in carnivorous and omnivorous than in herbivorous animal. In antibiotic susceptibility tests most of isolates were susceptible to cefazolinl ceftazidime, aztreoname, trimethoprin/sulfamethoxazole, gentamicin, ciprofloxacin, cofuroximel ceftriaxone, cefotaxime and eftizoximel and moderately susceptible to cephalotin and ticarcillin but resistant to ticarcillin/K and amikacin.

  • PDF

Development of System For Cell Fusion Detection (세포 전기 융합 감지 장치에 관한 연구)

  • Kwon, Ki-Jin;Kim, Min-Soo;Park, Se-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1336-1338
    • /
    • 1994
  • Cell fusion device is an artificial equipment which fuses electrically two types of cells fed from the respective micropump to the fusion chamber by electric pulses. In this case, the detective sensor of flowing cell, along with passage, is required to control the time of pulses applied to cell and the injection of cells which are fed from inlet to micropump. There are two methods of detection of flowing cell; optical, impedance method. The difference of output for optical sensor is about 426mV for 805nm wavelength. about 37mV for 665nm wavelength. In impedance method, sensor output is 132.33mV at middle point and 117.10mV at edge point in the channel. Experimental results show that the optimal frequency range of sensor output is Iron 50Hz to 400Hz.

  • PDF

Partial Discharge Diagnosis technology of EHV Underline Transmission XLPE cable applied FSA (FSA를 적용한 초고압 지중송전 XLPE케이블의 부분방전 진단기술)

  • Shin, D.H.;Lee, Y.S.;Yang, J.S.;Park, N.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.153-154
    • /
    • 2006
  • We studied the improved detecting method on Partial Discharge occurred in EHV power cable. In this field, we usually applied the several sensor for partial discharge. This is metal foil employed with the capacity foil-sensor. We detected the partial discharge through regularly array standard foil-sensor for the better improvement of existed foil-sensor in this research. This test is progressed in real EHV liveline, we analyzed that compare existed foil-sensor to detect character of FSA(Foil Sensor Array) for this test. From this result, detective character of fabricated FSA showed better result than existed foil-sensor.

  • PDF