• 제목/요약/키워드: Detection sensitivity

검색결과 2,495건 처리시간 0.031초

Attack Detection on Images Based on DCT-Based Features

  • Nirin Thanirat;Sudsanguan Ngamsuriyaroj
    • Asia pacific journal of information systems
    • /
    • 제31권3호
    • /
    • pp.335-357
    • /
    • 2021
  • As reproduction of images can be done with ease, copy detection has increasingly become important. In the duplication process, image modifications are likely to occur and some alterations are deliberate and can be viewed as attacks. A wide range of copy detection techniques has been proposed. In our study, content-based copy detection, which basically applies DCT-based features for images, namely, pixel values, edges, texture information and frequency-domain component distribution, is employed. Experiments are carried out to evaluate robustness and sensitivity of DCT-based features from attacks. As different types of DCT-based features hold different pieces of information, how features and attacks are related can be shown in their robustness and sensitivity. Rather than searching for proper features, use of robustness and sensitivity is proposed here to realize how the attacked features have changed when an image attack occurs. The experiments show that, out of ten attacks, the neural networks are able to detect seven attacks namely, Gaussian noise, S&P noise, Gamma correction (high), blurring, resizing (big), compression and rotation with mostly related to their sensitive features.

Fiber Ring Laser Intra-cavity Absorption Spectroscopy for Gas Sensing: Analysis and Experiment

  • Li, Mo;Liu, Kun;Jing, Wencai;Peng, Gang-Ding
    • Journal of the Optical Society of Korea
    • /
    • 제14권1호
    • /
    • pp.14-21
    • /
    • 2010
  • Fiber ring laser based intra-cavity absorption spectroscopic sensor has great potential for high sensitivity gas detection. Using the rate equations and propagation equations, we investigated theoretically factors that affect the sensitivity of such fiber ring laser sensors and determined the optimal design parameters and conditions for significant enhancement of the system sensitivity. Experiments have been conducted to determine the sensitivity enhancement performance. The results showed a factor of 25 ~ 30 in sensitivity enhancement in the experimental system, agreeing well with the theoretical expectations. Experiments on acetylene detection have also been carried out and the results showed that the ring cavity significantly increases the signal absorption and that high sensitivity can be obtained for gas detection.

236U accelerator mass spectrometry with a time-of-flight and energy detection system

  • Li Zheng;Hiroyuki Matsuzaki;Takeyasu Yamagata
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4636-4643
    • /
    • 2022
  • A time-of-flight and energy (TOF-E) detection system for the measurement of 236U accelerator mass spectrometry (AMS) has been developed to improve the 236U/238U sensitivity at Micro Analysis Laboratory, Tandem accelerator (MALT), The University of Tokyo. With observing TOF distribution of 235U, 236U and 238U, this TOF-E detection system has clearly separated 236U from the interference of 235U and 238U when measuring three kinds of uranium standards. In addition, we have developed a novel method combining kernel-based density estimation method and multi-Gaussian fitting method to estimate the 236U/238U sensitivity of the TOF-E detection system. Using this new estimation method, 3.4 × 10-12 of 236U/238U sensitivity and 1.9 ns of time resolution are obtained. 236U/238U sensitivity of TOF-E detection system has improved two orders of magnitude better than that of previous gas ionization chamber. Moreover, unknown species other than uranium isotopes were also observed in the measurement of a surface soil sample, which has demonstrated that TOF-E detection system has a higher sensitivity in particle identification. With its high sensibility in mass determination, this TOF-E detection system could also be used in other heavy isotope AMS.

우유중 잔류 항생물질 분서방법에 관한 비교연구 (A Comparative Study of the Detectable Methods of Residual Antibiotics in Milk)

  • 백선영;김형일;박건상;김소희;권경란
    • 한국식품위생안전성학회지
    • /
    • 제11권2호
    • /
    • pp.129-132
    • /
    • 1996
  • Recently, as concern about the residual antibiotics in milk increase, the detection methods of residual antibiotics used extensevely at the present time were investigated and compared to their properties and the detection limits of variable antibiotics. At first, comparactive tests of the detectable sensitivity of 4 test organisms, B. cereus, B. subtilis, M.luteus, B.stearothermophilus C-953, were performed by disc assay. As a result, B.stearothermophilus was the most sensitive strain of all other strains and showe the detect limit of 5-50 ppb for penlicillins (PCs). And also, B.subitilis was showed the more effective detection limit, 200-400 ppb, for aminoglycosides (AGs) and M.luteus was showed predominant sensitivity , 50-500 ppb for macrolides(MLs) and B.cereus was the most sensitive strain for tetracyclines (TCs) and showed the detection limit of 100-400 ppb. Therefore, each test strains were showed a different sensitivity in the detection of the different antibiotic families. When the detection limit of disc assay and other methods were compared, TTCmethod was less sensitive than other methods showing 5-50 ppb detectable lebel for PCs. Also, for the detection of other antibiotic families TTC method was showed the worst sensitivity and Delvo and Charm Farm tests were similar to the detectable properties of AGs and MLs. Although disc assay was showed the similar detection limit for PCs with Delvo and Charm Farm, it was more widely effective for the detection of kanamycin, erythromycin, chlortetracycline, doxycycline, verginiamycin and so on than Delvo or Charm Farm. CharmII test was showed the best sensitivity for the most of antibiotics except neomycin and gentamycin. But it was necessary that different tests must be performed to each antibiotic family and so it was regarded that the effectiveness of that method was low.

  • PDF

감도해석을 이용한 구조물의 손상위치 및 크기해석 (Analysis of a Structural Damage Detection Using Sensitivity Analysis)

  • 이정윤
    • 한국공작기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.50-55
    • /
    • 2003
  • This study proposed the analysis of damage detection due to the change of the stiffness of structure by using the original and modified dynamic characteristics. The present approach allows the use of composite data which consist of eigenvalues and eigenvectors. The suggested method is applied to examples of a cantilever and 3 degree of freedom system by modifying the stiffness. The predicted damage detections are in good agreement with these from the structural reanalysis using the modified stiffness.

모달 데이터의 감도계수를 이용하여 보의 균열 탐지 (Crack Detection in Beam using Sensitivity Coefficient of Modal Data)

  • 이정윤
    • 한국생산제조학회지
    • /
    • 제22권6호
    • /
    • pp.950-956
    • /
    • 2013
  • This paper describes a sensitivity-coefficient-based iterative method for detecting cracks in a structure. The sensitivity coefficients of a cracked structure are obtained by changing its eigenvectors. The proposed method is applied to a cracked cantilever. The crack is modeled as a rotational stiffness. The predicted cracks are in good agreement with those from a structural reanalysis of the cracked structure.

In-situ Endpoint Detection for Dielectric Films Plasma Etching Using Plasma Impedance Monitoring and Self-plasma Optical Emission Spectroscopy with Modified Principal Component Analysis

  • 장해규;채희엽
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.153-153
    • /
    • 2012
  • Endpoint detection with plasma impedance monitoring and self-plasma optical emission spectroscopy is demonstrated for dielectric layers etching processes. For in-situ detecting endpoint, optical-emission spectroscopy (OES) is used for in-situ endpoint detection for plasma etching. However, the sensitivity of OES is decreased if polymer is deposited on viewport or the proportion of exposed area on the wafer is too small. To overcome these problems, the endpoint was determined by impedance signal variation from I-V monitoring (VI probe) and self-plasma optical emission spectroscopy. In addition, modified principal component analysis was applied to enhance sensitivity for small area etching. As a result, the sensitivity of this method is increased about twice better than that of OES. From plasma impedance monitoring and self-plasma optical emission spectroscopy, properties of plasma and chamber are analyzed, and real-time endpoint detection is achieved.

  • PDF

A novel sensitivity method to structural damage estimation in bridges with moving mass

  • Mirzaee, Akbar;Shayanfar, Mohsenali;Abbasnia, Reza
    • Structural Engineering and Mechanics
    • /
    • 제54권6호
    • /
    • pp.1217-1244
    • /
    • 2015
  • In this research a theoretical and numerical study on a bridge damage detection procedure is presented based on vibration measurements collected from a set of accelerometers. This method, referred to as "Adjoint Variable Method", is a sensitivity-based finite element model updating method. The approach relies on minimizing a penalty function, which usually consists of the errors between the measured quantities and the corresponding predictions attained from the model. Moving mass is an interactive model and includes inertia effects between the model and mass. This interactive model is a time varying system and the proposed method is capable of detecting damage in this variable system. Robustness of the proposed method is illustrated by correct detection of the location and extension of predetermined single, multiple and random damages in all ranges of speed and mass ratio of moving vehicle. A comparative study on common sensitivity and the proposed method confirms its efficiency and performance improvement in sensitivity-based damage detection methods. In addition various possible sources of error, including the effects of measurement noise and initial assumption error in stability of method are also discussed.

4분할 광 검출기 상의 광점 크기가 변위 측정감도에 미치는 영향 (Effect of the Incident Optical Spot Size Upon the Quadrant Photodetector on the Optical Displacement Detection Sensitivity)

  • 이은중;이진우;고태준
    • 한국자기학회지
    • /
    • 제18권2호
    • /
    • pp.71-74
    • /
    • 2008
  • 본 논문에서는 4분할 광 검출기 상에 입사된 광점의 크기에 따른 optical beam deflection방식에서의 변위 측정감도의 변화에 대해 살펴보았다. 3mW의 헬륨-네온 레이저를 사용하여 optical beam deflection방식의 광학적 변위 측정 장치를 제작하였으며 광 검출기에 도달하는 광점의 크기를 변화시켜가며 제작된 변위 측정 장비가 나타내는 변위 측정감도를 관찰하였다. 또한 광 검출기에 도달하는 optical beam power를 원형의 균일한 분포를 지닌 광점으로 설정하여 광점 크기의 변화에 따른 변위 측정감도를 계산하였다. 측정된 결과와 계산을 통하여 검출기 상에 입사하는 광점의 크기가 작을수록 변위 측정감도가 증가함을 알 수 있었으며 이는 나노미터 급의 변위측정 장비 개발에 있어 광 검출기에 도달하는 광점의 크기를 최소화함으로써 변위 측정감도를 최적화 할 수 있음을 나타낸다.

Array-based Nano-amplification Technique Was Applied in Detection of Hepatitis E Virus

  • Liu, Hui-Hui;Cao, Xuan;Yang, Yong;Liu, Ming-Gui;Wang, Ye-Fu
    • BMB Reports
    • /
    • 제39권3호
    • /
    • pp.247-252
    • /
    • 2006
  • A rapid method for the detection of Hepatitis E Virus (HEV) was developed by utilizing nano-gold labeled oligonucleotide probes, silver stain enhancement and the microarray technique. The 5'-end -$NH_2$ modified oligonucleotide probes were immobilized on the surface of the chip base as the capture probe. The detection probe was made of the 3'-end -SH modified oligonucleotide probe and nano-gold colloid. The optimal concentrations of these two probes were determined. To test the detection sensitivity and specificity of this technique, a conservative fragment of the virus RNA was amplified by the RT-PCR/PCR one step amplification. The cDNA was hybridized with the capture probes and the detection probes on microarray. The detection signal was amplified by silver stain enhancement and could be identified by naked eyes. 100 fM of amplicon could be detected out on the microarray. As the results, preparation of nano-gold was improved and faster. Development time also was shortened to 2 min. Thus, considering high efficiency, low cost, good specificity and high sensitivity, this technique is alternative for the detection of HEV.