• Title/Summary/Keyword: Detection Pressure

Search Result 658, Processing Time 0.028 seconds

A Study on Vital Signal Detection Using UWB Pulse (UWB 펄스를 이용한 인체 신호 검출 방법 연구)

  • Jang, Dong-Won;Choi, Jae-Ik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.465-468
    • /
    • 2014
  • In this paper, we describe a method capable of measuring biological signals including respiration, heart rate, blood pressure, and blood sugar, using UWB (Ultra Wide Band) pulses, while does not contact the human body. Physiological signal is a basic data for checking the health. Because life is longer and active area of human becomes very broad, the medical system and the physical human resources which are focused on existing hospital must be located close patient, In that way, they hope be to engage in healthy life by stepping a quick step and treatment. Thus, it must be fitted closely to the patient. It is necessary to monitor the health without inconvenience on an ongoing basis. How to utilize radio waves in this way have been studied for a long time. However, the characteristics of radio waves on the human body has not been accurately grasped and developed as such. Accordingly, it is a level that can not be applied clinically. So, it is not widely put to practical use. In this paper, We analyzed and described the impact and characteristics of UWB pulses to the human body is a problem existing.

  • PDF

Novel Anomaly Detection Method for Proactive Prevention from a Mobile E-finance Accident with User"s Input Pattern Analysis (모바일 디바이스에서의 전자금융사고 예방을 위한 사용자입력패턴분석 기반 이상증후 탐지 방법)

  • Seo, Ho-Jin;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.4
    • /
    • pp.47-60
    • /
    • 2011
  • With the increase in the use of mobile banking service, mobile banking has become an attractive target to attackers. Even though many security measures are applied to the current mobile banking service, some threats such as physical theft or penetration to a mobile device from remote side are still remained as unsolved. With aiming to fill this void, we propose a novel approach to prevent e-financial incidents by analyzing mobile device user's input patterns. This approach helps us to distinguish between original user's usage and attacker's usage through analyzing personal input patterns such as input time-interval, finger pressure level on the touch screen. Our proposed method shows high accuracy, and is effective to prevent the e-finance incidents proactively.

Status of the Real-time Safety Monitoring System of Hydrogen Refueling Station According to the Operation (수소충전소 실시간 이중 모니터링 시스템 운영을 통한 안전성 향상)

  • Lee, Jin-Woo;Park, Jong-Hee;Kim, Dae-Hyun;Tak, Song-Su;Yang, Byung-Jo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.92-97
    • /
    • 2021
  • In accordance with the revision of the Enforcement Regulations of the High-Pressure Gas Safety Management Act in February 2021, from August 27, 2021, the operation status of safety devices such as gas leak detection and alarm devices, emergency shut-off devices and flame detectors installed at hydrogen vehicle charging stations can be monitored in real time. It is transmitted and operated by the computer system managed by Korea Gas Safety Corporations. We intend to share the results of statistical analysis of abnormal signals that have occurred along with the results of the monitoring system construction so that they can be used for the safety management of hydrogen refueling stations, and to seek future safety management directions.

The Advanced Analytical Method Through the Quantitative Comparative Study of Taurine in Feed Using LC-MS/MS

  • Seon, Yeong Jun;Seo, Hyung Ju;Yoon, Jiye;Cho, Hyunjeong;Hong, Sunghie;Lee, Seung Hwa;Na, Tae Woong
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.133-138
    • /
    • 2022
  • Taurine is a type of sulfur-containing amino acid having a sulfate functional group, that is biosynthesized from cysteine. It is mainly distributed in high concentrations in animal tissues and is known to have various effects such as osmotic pressure control, calcium control, anti-inflammatory, antioxidant, and hepatocellular protection. Also, taurine deficiency causes a variety of symptoms, including visual impairment. In particular, in the case of cats, taurine is not biosynthesized and must be supplied through food, so it is classified as an essential amino acid. In this study, an analysis method using mass spectrometry was developed instead of the commonly used derivatization method to quickly, environmentally, and precisely analyze taurine in various animal feeds. The developed analytical method showed good linearity (R2 > 0.99), accuracy (81.97-105.78%), and precision (0.07-12.37%). In addition, the developed method was further verified through quantitative comparison with the derivatization method. This developed method was used in the determination of taurine in 20 animal feed samples obtained from South Korea. The levels of taurine found ranged from 81.53 to 6,743.53 mg/kg. The developed analysis method will be used for the detection and quantification of taurine in domestic feed.

Development of a pipe burst detection model using large consumer's smart water meter and pressure data (대수용가 스마트미터와 수압 데이터를 이용한 소블록 내 관 파손사고 감지모델 개발)

  • Kyoung Pil Kim;Wan Sik Yu;Shin Uk Kang;Doo Yong Choi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.521-521
    • /
    • 2023
  • 지방상수도의 관 파손사고 감지 및 누수관리 방법에는 블록시스템 구축을 통한 소블록별 야간최소유량 감시방법이 가장 대표적이다. 야간최소유량은 새벽 2시와 4시 사이의 인구 활동 비율이 가장 낮은 새벽 시간대에 소블록에 공급된 유량을 의미하며, 대부분 유량 성분은 누수량일 것이라는 가정에서 출발한다. 그러나 아파트 중심의 주거 형태를 보이는 도심지의 경우, 새벽 시간대에도 다량의 물수요가 비정기적으로 발생하고 있어 관망의 이상 여부를 감시하기 위한 관리기준으로서 야간최소유량을 이용하기에는 높은 일간 변동성에 따른 한계가 있다고 할 수 있다. 즉, 야간최소유량은 관 파손사고 발생의 감시보다는 관로 연결 또는 급수전 분기 부위에서 발생하는 미량의 누수가 수개월에 걸쳐 누적되는 장기추세를 분석하여 누수탐사반의 투입 시점을 결정하기 위한 근거를 제시하기 위한 목적으로 사용되며, 아직까지 관 파손사고의 발생은 자체적인 감지보다는 민원에 의해 인지되는 경우가 많다. 최근, 스마트관망 구축사업(SWM) 등을 통해 관 파손 및 누수 감지를 위한 청음식 누수감지센서가 소블록 내 도입되고 있으나, 초기 시설투자에 큰 비용이 수반되며 주변 소음과 배터리 전원방식의 한계로 인하여 새벽 시간대에만 분석이 제한적으로 적용되는 경우가 많아 이 역시도 상시적인 관 파손사고의 감시기술이라 보기는 어렵다. 본 연구에서는 소블록 유입점에서의 유량·압력과 소블록 내에 설치된 대수용가 스마트미터, 그리고 사고감지를 위한 수압계 사이의 평상시 수리적 균형을 학습한 DNN(Deep Neural Network) 모델을 이용하여 관 파손사고를 실시간 감지하는 모델 개발연구를 수행하였다. 모델은 관 파손사고 감지를 위한 수압계의 최적 위치와 대수를 결정하기 위한 모듈과 관 파손사고 감지모듈로 구성되며, 1개 소블록 Test-Bed를 구축하여 모델을 생성하고 PDD 관망해석 모델을 통해 생성된 가상의 사고에 대한 감지 여부로서 개발 모델의 감지성능을 평가하였다.

  • PDF

Inter-device agreement between spectral domain optical coherence tomography, ultrasound biomicroscopy, and gonioscopy in evaluating the iridocorneal angle in normotensive dogs

  • Su An Kim;Jaeho Shim;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.4
    • /
    • pp.34.1-34.12
    • /
    • 2023
  • Background: There has not been a thoroughly reported study of the comparison between spectral domain-optical coherence tomography (SD-OCT) with both ultrasound biomicroscopy (UBM) and gonioscopy on the evaluation of the iridocorneal angle (ICA) in dogs. Objectives: To investigate the diagnostic value of SD-OCT for the early detection of narrowing ICA by comparing and assessing inter-device agreement in anterior chamber angle (ACA) measurements obtained by SD-OCT and UBM, and ICA evaluations by gonioscopy. Methods: A total of 28 eyes from 28 client-owned dogs with normal intraocular pressure were included for examination. The ACA and angle opening distance (AOD) were measured from the SD-OCT and UBM images, and gonioscopy images were analyzed using the ICA grade and ZibWest angle index. Results: The mean ACA and AOD for SD-OCT were 28.31° ± 5.37° and 658.42 ± 219.90 ㎛, and for UBM, 28.34° ± 5.82° and 859.29 ± 221.80 ㎛, respectively. The mean difference in ACA between the average values of SD-OCT and UBM measurements was 0.03° with a 95% limit of agreement (LoA) span of 16.2°, indicating positive agreement; that in AOD was 200.85 ㎛ with a 95% LoA span of 1,110.95 ㎛, indicating poor agreement. The Pearson correlation coefficient of the ACA of SD-OCT and ZibWest indices of gonioscopy was 0.624, indicating strong agreement; that of UBM and gonioscopy was 0.43, indicating moderate agreement. Conclusions: SD-OCT is well tolerated by canine patients due to its non-contact method and might be an alternative option for early screening of ICA narrowing in clinical settings.

Feasibility Study on Detection of Defective Elements in a Linear Phased Array Transducer through Ultrasonic Field Analysis and Visualization (초음파 음장해석 및 가시화를 통한 선형 위상차배열 트랜스듀서의 결함요소 검출 가능성 연구)

  • Choi, Kwang-Yoon;Yang, Jeong-Won;Ha, Kang-Lyeol;Kim, Moo-Joon;Kim, Jung-Soon;Lee, Chae-Bong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.5
    • /
    • pp.416-423
    • /
    • 2009
  • The ultrasonic pressure fields for the 3 MHz linear phased array transducer with sixteen piezoelectric elements of which one may not be operated by defect were simulated theoretically and measured experimentally using a visualization system of the Schlieren method. The simulation results for steering angles of $0^{\circ}$ and $30^{\circ}$ show that the side-lobe patterns of the transducer including a defective element is quite different from the transducer with all normal elements, and those patterns are in good agreement with the results of visualization. It is shown that the defective elements in a linear array transducer can be detected by comparison of the simulated and the visualized side-lobe patterns in two dimensional acoustic fields.

Inferior Vena Cava Stenosis Following Orthotopic Liver Transplantation: Differentiating Points from False Positives (뇌사자 간이식 후 발생한 하대정맥 협착: 위양성과의 감별점)

  • Yeonsoo Choi;Jin Hyeok Kim;Ung Bae Jeon;Joo Yeon Jang;Tae Un Kim;Hwaseong Ryu
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.713-718
    • /
    • 2023
  • Orthotopic liver transplantation has become the treatment of choice for patients with end-stage liver disease. Various early or delayed vascular complications, including arterial pseudoaneurysm, thrombosis, or stenosis, and venous stenosis or occlusion, may lead to graft failure. Early detection and prompt management of such complications are essential to achieve successful transplantation and prevent the need for retransplantation. This report presents differentiating points, using computed tomography and digital subtraction angiography findings and measurement of pressure gradient across the stenotic lesion, that require immediate intervention in patients with inferior vena cava stenosis after orthotopic liver transplantation.

The detection of collapsible airways contributing to airflow limitation (기류 제한에 영향을 미치는 허탈성 기도의 분석)

  • Kim, Yun Seong;Park, Byung Gyu;Lee, Kyong In;Son, Seok Man;Lee, Hyo Jin;Lee, Min Ki;Son, Choon Hee;Park, Soon Kew
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.558-570
    • /
    • 1996
  • Background : The detection of Collapsible airways has important therapeutic implications in chronic airway disease and bronchial asthma. The distinction of a purely collapsible airways disease from that of asthma is important because the treatment of the dormer may include the use of pursed lip breathing or nasal positive pressure ventilation whereas in the latter, pharmacologic approaches are used. One form of irreversible airflow limitation is collapsible airways, which has been shown to be a Component of asthma or to emphysema, it can be assessed by the volume difference between what exits the lung as determined by a spirometer and the volume compressed as measured by the plethysmography. Method : To investigate whether volume difference between slow and forced vital Capacity(SVC-FVC) by spirometry may be used as a surrogate index of airway collapse, we examined pulmonary function parameters before and after bronchodilator agent inhalation by spirometry and body plethysmography in 20 cases of patients with evidence of airflow limitation(chronic obstructive pulmonary disease 12 cases, stable bronchial asthma 7 cases, combined chronic obstructive pulmonary disease with asthma 1 case) and 20 cases of normal subjects without evidence of airflow limitation referred to the Pusan National University Hospital pulmonary function laboratory from January 1995 to July 1995 prospectively. Results : 1) Average and standard deviation of age, height, weight of patients with airflow limitation was $58.3{\pm}7.24$(yr), $166{\pm}8.0$(cm), $59.0{\pm}9.9$(kg) and those of normal subjects was $56.3{\pm}12.47$(yr), $165.9{\pm}6.9$(cm), $64.4{\pm}10.4$(kg), respectively. The differences of physical characteristics of both group were not significant statistically and male to female ratio was 14:6 in both groups. 2) The difference between slow vital capacity and forced vital capacity was $395{\pm}317ml$ in patients group and $154{\pm}176ml$ in normal group and there was statistically significance between two groups(p<0.05). Sensitivity and specificity were most higher when the cut-off value was 208ml. 3) After bronchodilator inhalation, reversible airway obstructions were shown in 16 cases of patients group, 7 cases of control group(p<0.05) by spirometry or body plethysmography d the differences of slow vital capacity and forced vital capacity in bronchodilator response group and nonresponse group were $300.4{\pm}306ml$, $144.7{\pm}180ml$ and this difference was statistically significant. 4) The difference between slow vital capacity and forced vital capacity before bronchodilator inhalation was correlated with airway resistance before bronchodilator(r=0.307 p=0.05), and the difference between slow vital capacity and forced vital capacity after bronchodilator was correlated with difference between slow vital capacity and forced vital capacity(r=0.559 p=0.0002), thoracic gas volume(r=0.488 p=0.002) before bronchodilator and airway resistance(r=0.583 p=0.0001), thoracic gas volume(r=0.375 p=0.0170) after bronchodilator, respectively. 5) The difference between slow vital capacity and forced vital capacity in smokers and nonsmokers was $257.5{\pm}303ml$, $277.5{\pm}276ml$, respectively and this difference did not reach statistical significance(p>0.05). Conclusion : The difference between slow vital capacity and forced vital capacity by spirometry may be useful for the detection of collapsible airway and may help decision making of therapeutic plans.

  • PDF

Examination of the Current Situations of Security Dogs and it's Development Plans (경호탐지견의 운용실태 및 발전방안)

  • Park, Hyung-Kyu;Kim, Doo-Hyun
    • Korean Security Journal
    • /
    • no.14
    • /
    • pp.215-234
    • /
    • 2007
  • Our country security industry 1960's service expense of the beginning U.S. army unit it accomplishes the growth which is quick with start, currently about 2,500 triumph the security enterprises which it goes over are being active. But the majority in these enterprise about lower cotton can a forever characteristic with pressure and the manpower civil official ability insufficient back of faithlessness management and capital power. To sleep with afterwords it presents the security dogs deployment plan for an efficient security together from the research which it sees hereupon and it does. First, it cultivates the domestic mountain progress dog which is a breed which is suitable with the security dogs and the shovel flesh dog back with the security dogs. Specially the Jindo of the breed which is excellent training which is suitable in task of the security dogs it leads and if it uses appropriately, it industrializes our specific the Jindo and protection there is a possibility of getting the effect which falls to also the gist which it rears rightly. It cultivate the second, security dogs and it magnifies training. The security dogs consequently is it will be able to accomplish the task above 2 branches to training method. Namely, after finishing obedience training, it is to be in security activity it will execute guard or detection back special training which is suitable in task and it will be able to commit. Third, it uses the security dogs which is trained rightly in task. The security dogs the adult escorts, facility expense, the explosive and narcotic drug detection, it will be able to use with the other blind man guidance dogs back. The narcotic drug detection dogs which currently is used specially technique intelligence anger, when considering the tendency of the narcotic drug smuggling offense field which becomes diversification that the role very it is important is a possibility of saying at day. It cultivate a fourth, escort relation specialty manpower and it improves the breed of the security dogs. The hazard which cultivate the security dogs use necessary personnel the breed of security dogs, the security dogs training center it opens the security crane relation subject of the college which stands and (university) it improves it establishes and training which is suitable in task it is to do to execute letting in the training map company. Specially, the hazard which improves the breed of security dogs in the progress mind quality which stands against the portion where the breed improvement is demanded as the portion where the internal organs research and investment are necessary sees. The security dogs compares in labor cost and the expense holds few, if it uses the our specific domestic dogs it will be able to use efficiently in the task which is various it solves the multi branch plans for wisly with the security dogs industrial development security of course contemporary history sliced raw fish sees demands compared to being immediacy and the life which is happy business the place where it does it sees it will be able to contribute a lot as.

  • PDF