• 제목/요약/키워드: Detection Circuit

검색결과 696건 처리시간 0.024초

전자장해석을 통한 발전기 회전자권선 단락특성 예측 (Predictions of Short-Circuit Characteristics of Rotor Windings in a Generator using Electromagnetic Analysis)

  • 김동훈;송명곤;박중신;이동영
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권11호
    • /
    • pp.572-576
    • /
    • 2006
  • As the increasing of capacity and technology of power facilities, rotating machines such as turbine generators and water turbines are getting higher at capacity but smaller in size. Thus the monitoring and diagnosis of generators for fault detection and protection has attracted intensive interest. Most of electrical faults of rotating machines appear in their windings. In case of an after-fault in high capacity rotating machines, the recovering cost is usually very expensive and additional time is necessary for returning in a normal situation. In this paper, the magnetic flux patterns in air-gap of a generator under various fault states as well as a normal state are simulated by a conventional FEM tool. These results are successfully applied to detection and diagnosis of the short-circuit condition in rotor windings of a high capacity generator.

원형방사상편향에 의한 방사능계측용 기록장치 (A Recording System For Nuclear Radation Detection by Means Of Circular Radial Deflection)

  • 이희용
    • 대한전자공학회논문지
    • /
    • 제3권3호
    • /
    • pp.14-21
    • /
    • 1966
  • 원형방사상편향의 기록방식을 이용한 방사선계측장치로서 그 장치내용과 계측에의 응용례를 기술하였다. 장치의 전자관회로에 있어서 특수한 승산회로를 안출하므로써 원형시간축 뿐만 아니라 그 위에 나타난 펄스의 직선성도 잘 고려되었다. 논리회로에 의해서 1싸이클동안만 밝게하고 다음의 수사이클 동안을 어둡게 하므로써 방사선에 의한 랜돔 펄스를 원형시간축상에 나타내어 이것을 사진으로 기록할 수 있게 하였다. 본장치는 단수명핵종의 감리곡선과 그 파고분포곡선을 얻는데 적당한 것이다.

  • PDF

다목적 수동형 라돈농도 측정기 개발 (Development of A Multipurpose Passive Type Radon Monitor)

  • 이봉재;박영웅
    • 동위원소회보
    • /
    • 제21권4호
    • /
    • pp.55-65
    • /
    • 2006
  • A passive type radon monitor adopting two silicon PIN detector as radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this instrument has been performance-tested by using reference radon concentration and a reference photon radiation field. As a result, in a electronic performance test, radiation signals from each detector were well observed in each signal processing circuit. The radiation detection sensitivity of this instrument after several test-irradiations to a Cs-137 gamma radiation source and a standard radon concentration appeared to be 1.37 cph/$\mu$Svh-1 and 1.66 pCi/L respectively. The developed radon monitor in this paper could be used conveniently in monitoring of radon concentration in buildings which population utilize in Korea.

  • PDF

펄스방사선 탐지를 위한 Photo Diode 출력특성 연구 (The Study of the Photo Diode Output Signal for Pusle Radiation Detection)

  • 황영관;이남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.869-871
    • /
    • 2012
  • 고도의 과학기술발전으로 인해 일상생활에서 전자기기의 사용이 급속도로 늘어가고 있다. 또한 태양의 흑점 폭발이나 북한의 핵폭탄, 원전 사고 등으로 인해 방사선에 대한 관심도가 증가하고 있다. 태양으로부터 방출되는 펄스형태의 방사선은 전자장비에 장애를 초래하며 특히 핵폭발 시 전달되는 고준위 펄스 방사선의 경우 전자부품에 오동작 및 불용상태로 까지 영향을 미칠 수 있다. 이러한 방사선 영향에 대한 연구는 국내외에서 다양하게 진행되고 있다. 본 논문에서는 이러한 전자 부품에 영향을 줄 수 있는 펄스방사선 탐지를 위해 Si 기반의 포토다이오드를 제작하고 이를 통해 펄스 입출력 신호에 대한 회로 시뮬레이션과 일반 광원을 이용한 출력 특성을 연구하였다. 본 연구의 결과는 고 에너지의 펄스 방사선 영향으로부터 전자회로를 보호하기 위한 추가적인 모듈의 입력 센서로 활용 될 수 있다.

  • PDF

Improved Metal Object Detection Circuits for Wireless Charging System of Electric Vehicles

  • Sunhee Kim
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제17권8호
    • /
    • pp.2209-2221
    • /
    • 2023
  • As the supply of electric vehicles increases, research on wireless charging methods for convenience has been increasing. Because the electric vehicle wireless transmission device is installed on the ground and the electric vehicle battery is installed on the floor of the vehicle, the transmission and reception antennas are approximately 15-30 cm away, and thus strong magnetic fields are exposed during wireless charging. When a metallic foreign object is placed in the magnetic field area, an eddy current is induced to the metallic foreign object, and heat is generated, creating danger of fire and burns. Therefore, this study proposes a method to detect metallic foreign objects in the magnetic field area of a wireless electric vehicle charging system. An active detection-only coil array was used, and an LC resonance circuit was constructed for the frequency of the supply power signal. When a metallic foreign object is inserted into the charging zone, the characteristics of the resonance circuit are broken, and the magnitude and phase of the voltage signal at both ends of the capacitor are changed. It was confirmed that the proposed method has about 1.5 times more change than the method of comparing the voltage magnitude at one node.

Long term activity measurement of the primary circuit water on the LVR-15 research reactor

  • Ladislav Viererbl;Vit Klupak;Hana Assmann Vratislavska
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1250-1253
    • /
    • 2024
  • Activity measurement of the primary circuit water of fission reactors is one method that can provide early detection of a damaged fuel assembly in the reactor core. This is an important aspect in the safe operation of the reactor and for radiation protection of staff. Radionuclides in the primary circuit water are produced by the activation of stable nuclides and the fission of fissile nuclides, mainly the isotope 235U. In the LVR-15 research reactor, measurement of the activity of the primary circuit water has been regularly undertaken since 1996. A water sample is taken from the primary circuit every week and the activities are measured four days later using gamma spectrometry. The results of these long-term measurements from 1996 to 2022 are presented. The activity time dependences of the individual radionuclides are discussed in relation to fuel assembly damage and for events connected to contamination of the water by objects inserted into the primary circuit during experiments carried out near the reactor core.

직렬아크신호지 검출방법 (Detection Method of Series Arc Signal)

  • 길경석;지홍근;박대원;김일권;류길수;송재용
    • 한국철도학회논문집
    • /
    • 제11권5호
    • /
    • pp.477-481
    • /
    • 2008
  • 본 논문은 저압계통에서 전기화재의 징후인 직렬아크의 검출방법에 대해 기술하였다. 제안한 검출회로는 전원주파수 성분을 80dB 이상 감소시킬 수 있는 저역차단주파수가 3kHz인 고역통과필터와 아크신호만을 검출하기 위한 중심주파수가 4kHz인 대역통과필터로 구성된다. UL1699에 규정된 아크발생장치를 이용하여 비선형부하인 위상제어 백열전구와 고주파발생부하인 인버터 추동 유도전동기에서 직렬아크신호를 모의하여 성능을 평가하였다. 실험 결과로부터 세안한 방식은 비선형부하와 고주파발생하에 대해서도 직렬아크신호를 정확히 구분함으로써 현재 최대 문제인 검출오류를 해결하였음이 확인되었다.

노이즈에 둔감한 레이저 진동계측기용 실시간 신호처리 장치에 관한 연구 (A Study on the Robust Real-Time Signal Processor of a Laser Doppler Vibrometer for Noises)

  • 박승규;백성훈;김철중
    • 한국정밀공학회지
    • /
    • 제16권1호통권94호
    • /
    • pp.61-67
    • /
    • 1999
  • A laser Doppler vibrometer based on the laser heterodyne interferometry is employed to measure the vibration velocity of vibrating objects. In this paper, we propose a real time analog signal processor of a laser Doppler vibrometer to reduce the degradation of Doppler signals mainly caused by environmental noises. In the proposed real time signal processor of an laser Doppler vibrometer, a pre-processor and a logical motion direction detector are designed to reduce the detection errors of the object motion direction. Also, a noise detection and rejection circuit is designed to reject the unfiltered noises.

  • PDF

자기검사 Pulse별 잉여수연산회로를 이용한 고신뢰화 Fault Tolerant 디지털필터의 구성에 관한 연구 (Implementation of High Reliable Fault-Tolerant Digital Filter Using Self-Checking Pulse-Train Residue Arithmetic Circuits)

  • 김문수;손동인;전구제
    • 대한전자공학회논문지
    • /
    • 제25권2호
    • /
    • pp.204-210
    • /
    • 1988
  • The residue number system offers the possibility of high-speed operation and error detection/correction because of the separability of arithmetic operations on each digit. A compact residue arithmetic module named the self-checking pulse-train residue arithmetic circuit is effectively employed as the basic module, and an efficient error detection/correction algorithm in which error detection is performed in each basic module and error correction is performed based on the parallelism of residue arithmetic is also employed. In this case, the error correcting circuit is imposed in series to non-redundant system. This design method has an advantage of compact hardware. Following the proposed method, a 2nd-order recursive fault-tolerant digital filter is practically implemented, and its fault-tolerant ability is proved by noise injection testing.

  • PDF

근본 출력에 근거한 고장 모의실험 (A Fault Simulation Method Based on Primary Output)

  • 이상설;박규호
    • 전자공학회논문지B
    • /
    • 제31B권6호
    • /
    • pp.63-70
    • /
    • 1994
  • In this paper, we propose a fault simulation method based on primary output in combinational circuit. In the deterministic test pattern generation, each test pattern is genterated incrementally. The test pattern is applied to the primary inputs of circuit under test to simulate faults. We detect the faults with respect to each primary output. The fault detection with resptect to each primary output is reflected by the corresponding bit in the detection words, and efficient fault detection for the reconvergent fan-out stem is achieved with dynamic fault propagation. As an experimental result of the fault simulation with our method for the several bench mark circuits, we illustrated the good performance showing that the number of gates to be activated is much reduced as compared with other method which is not based on primary output.

  • PDF