• Title/Summary/Keyword: Detection Circuit

Search Result 698, Processing Time 0.044 seconds

A Study on the Detection of Acoustic Signal Produced by Partial Discharges in Insulation Oil and its Positioning (부분방전에 의한 음향신호의 검출과 위치추정에 관한 연구)

  • Kil, Gyung-Suk;Park, Dae-Won;Kim, Il-Kwon;Choi, Su-Yeon;Park, Chan-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.907-911
    • /
    • 2007
  • This paper dealt with the frequency spectrum analysis of acoustic signal produced by partial discharge (PD) in insulation oil and the positioning of PD occurrence to apply in diagnosis of oil insulated transformers. Three types of electrode system ; the needle-plane, the plane-plane, and the wire-wire structure were assembled to simulate partial discharges in oil insulated transformers. A low-noise amplifier and a decoupling circuit were designed to detect acoustic signal with high sensitivity The frequency spectrum of the acoustic signal were 50 kHz ${\sim}$ 260 kHz in the needle-plane, 50 kHz ${\sim}$ 250 kHz in the plane-plane, and 45 kHz${\sim}$195 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 130 kHz and 114 kHz, respectively The position of PD occurrence was calculated by the time difference of arrival (TOA) using three acoustic emission (AE) sensors, and we could find the position within the error of 1 % in the experimental apparatus.

Determination of Lead(II) at Nation-Coated Glassy Carbon Electrodes Modified by Tetren-Glycerol (Nafion-Tetren-Glycerol이 수식된 유리탄소전극에서 납(II) 이온의 정량)

  • 반옥기;박은희;정근호
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.62-68
    • /
    • 2003
  • Differential pulse voltammetry (DPV) using nafion-coated glassy carbon electrodes modified with Tetren(tetraethylene pentamine)-glycerol showed sensitivity for determining lead (II) at low concentration. The Lead (II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry. Various experimental parameters, such as the composition of modifier, preconcentration time, pH of electrolyte (0.1 M acetate buffer), and parameters of differential pulse voltammetry, were optimized. The initial potential was applied for 50 s, the electrode was scanned from -0.9 to -0.3 V, and the anodic peak current was measured at -0.604 V $\pm$ 0.015 V (vs. Ag/AgCl). The calibration plot was obtained in the range 1.0$\times$10$^{-8}$ M~l.0$\times$10$^{-6}$ M with pH 4.5 buffer solution. The detection limit (3$\sigma$) it as low as 5.0$\times$ 10$^{-9}$ M. This method is applied to the determination of lead(II) in a certified reference material and the result agrees satisfactorily with the certified value.

Development and Experiment of a Linear Array Acoustic Lens with 31 Microphones (마이크로폰 31개로 이루어진 선형배열 음향렌즈의 구성과 실험)

  • Hyun, Seok-Bong;Min, Dong-Hyun;Kim, Su-Young
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.15-23
    • /
    • 1994
  • We developed an electronic lens for acoustic imaging systems, which is linear array with 31 microphones equally spaced with distance 34mm. Resonant frequency fo receiver circuit coupled to microphone is 20 kHz. We arranged 16 microphones horizontally and 15 microphones vertically, so that the array allows us to obtain a 2 dimensional angle of source, and to track the motion of source in real time. Due to the problem of aliasing in discrete Fourier Transfrom, the maximum observable angle of the lens is limited to 15${\circ}$. We also employed quadrature phase detection scheme to adjust the focus. We have tested the acoustic lens with a personal computer in an anechoic room and obtained the results agreed with the acoustic imaging theory.

  • PDF

UWB WBAN Receiver for Real Time Location System (위치 인식이 가능한 WBAN 용 UWB 수신기)

  • Ha, Jong Ok;Park, Myung Chul;Jung, Seung Hwan;Eo, Yun Seong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.98-104
    • /
    • 2013
  • This paper presents a WBAN UWB receiver circuit for RTLS(real time location system) and wireless data communication. The UWB receiver is designed to OOK modulation for energy detection. The UWB receiver is designed for sub-sampling techniques using 4bit ADC and DLL.The proposed UWB receiver is designed in $0.18{\mu}m$ CMOS and consumes 61mA with a 1.8V supply voltage. The UWB receiver achieves a sensitivity of -85.7 dBm, a RF front-end gain of 42.1 dB, a noise figure of 3.88 dB and maximum sensing range of 4 meter.

A Design of Gate Drive and Protection IC for Insulated Gate Power Devices (고전력 절연 게이트 소자의 구동 및 보호용 파워 IC의 설계)

  • Ko, Min-Joung;Park, Shi-Hong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.96-102
    • /
    • 2009
  • This paper deals with gate drive and power IC for high power devices(600V/200A and 1200V/150A). The proposed gate driver provides high gate driving capability (4 A source, 8 A sink), and over-current protected by means of power transistor desaturation detection. In addition, soft-shutdown function is added to reduce voltage overshoots due to parasitic inductance. This gate drive If is designed, fabricated, and tested using the Dongbu hitek 0.35um BCDMOS process.

A Carbazole Based Bimodal "Turn-On" Fluorescent Probe for Biothiols (Cysteine/Homocysteine) and Fluoride: Sensing, Imaging and its Applications

  • Kaur, Matinder;Yoon, Byungkwon;Kumar, Rajesh;Cho, Min Ju;Kim, Hak Joong;Kim, Jong Seung;Choi, Dong Hoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3437-3442
    • /
    • 2014
  • A well-known carbazole-based precursor (probe 1) was used for the detection of cysteine/homocysteine and fluoride. Probe 1 shows a "turn-on" response to cysteine/homocysteine and fluoride via enhancement in emission intensity at 442 nm and 462 nm respectively, in solutions and living cells. Furthermore, probe 1 behaves as a fluorescent molecular switch between cysteine/homocysteine and fluoride as the chemical inputs, which have been used for the development of a combinatorial logic circuit and a molecular keypad lock.

Arc-Flash Detection Sensor Based on Surface Coupling of Plastic Optical Fiber (플라스틱 광섬유 표면 입사 현상을 이용한 아크플래시 검출 광센서)

  • Jeong, Hoonil;Kim, Myoung Jin;Kim, Young Ho;Kim, Youngwoong;Rho, Byung Sup
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.208-212
    • /
    • 2016
  • In this work, a loop sensor for Arc-Flash detections has been developed in order to trip a circuit breaker within 2.5 ms after an Arc-Flash event. For an efficient capturing of the flash light, plastic optical fibers, where light attenuations are larger than those in silica-based ones, with different diameters and surface conditions were utilized. The performance was comparatively analyzed with those of a point sensor and a commercialized product. The point sensor module was designed for hemisphere-like capturings of Arc-Flashes larger than 3 kA at 2 meters from the sensor. On the other hand, the loop sensor allowed 360-degree-detections around the fiber axis and the measurement range was dependent on the length of the fiber connected to the sensor module. The trip-level-dependent brightness measurement results showed that the fabricated point sensor and loop sensor satisfied a brightness condition, 10~40 klux, and the responses of the system to Arc-Flashes were completed within 2.5 ms.

An Implementation of $5\times{5}$ CNN Hardware and Pre.Post Processor ($5\times{5}$ CNN 하드웨어 및 전.후 처리기 구현)

  • 김승수;정금섭;전흥우
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.416-419
    • /
    • 2003
  • The cellular neural networks have the circuit structure that differs from the form of general neural network. It consists of an array of the same cell which is a simple processing element, and each of the cells has local connectivity and space invariant template property. In this paper, time-multiplex image processing technique is applied for processing large images using small size CNN cell block, and we simulate the edge detection of a large image using the simulator implemented with a c program and matlab model. A 5$\times$5 CNN hardware and pre post processor is also implemented and is under test.

  • PDF

A Design of High Performance Parallel CRC Generator (고성능 병렬 CRC 생성기 설계)

  • Lee, Hyun-Bean;Park, Sung-Ju;Min, Pyoung-Woo;Park, Chang-Won
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.9A
    • /
    • pp.1101-1107
    • /
    • 2004
  • This paper presents an optimization algorithm and technique for designing parallel Cyclic Redundancy Check (CRC) circuit, which is most widely adopted for error detection A new heuristic algorithm is developed to find as many shared terms as possible, thus eventually to minimize the number and level of the exclusive-or logic blocks in parallel CRC circuits. 16-bit and 32-bit CRC generators are designed with different types of Programmable Logic Devices, and it has been found that our new algorithm and architecture significantly reduce the delay.

An Ultra-precision Electronic Clinometer for Measurement of Small Inclination Angles

  • Tan, Siew-Leng;Kataoka, Satoshi;Ishikawa, Tatsuya;Ito, So;Shimizu, Yuuki;Chen, Yuanliu;Gao, Wei;Nakagawa, Satoshi
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.539-546
    • /
    • 2014
  • This paper describes an ultra-precision electronic clinometer, which is based on the capacitive-based fluid type, for detection of small inclination angles. The main parts of the clinometer low-noise electronics are two capacitance measurement circuits for converting the capacitances of the capacitors of the clinometer into voltages, and a differential amplifier for obtaining the difference of the capacitances, which is proportional to the input inclination angle. A 16 bit analog to digital (AD) converter is also embedded into the same circuit board, whose output is sent to a PC via RS-232C, for achieving a small noise level down to tens of ${\mu}v$. A compensation method, which is referred to as the delay time method for shortening the stabilization time of the sensor was also discussed. Experimental results have shown the possibility of achieving a measurement resolution of $0.0001^{\circ}$ as well as the quick measurement with the delay time method.