• 제목/요약/키워드: Detection Circuit

검색결과 696건 처리시간 0.033초

상호연관 신경망에 기반을 둔 이동 검출을 위한 아날로그 집적회로 (Analog MOS circuits for motion detection based on correlation neural networks)

  • 심선일;김용태;박정호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(3)
    • /
    • pp.149-152
    • /
    • 2000
  • We propose simple analog MOS circuits producing the one-dimensional compact motion-sensing circuits. In the proposed circuit, the optical flow is computed by a number of local motion sensors which are based on biological motion detectors. Mimicking the structure of biological motion detectors made the circuit structure quite simple, compared with conventional velocity sensing circuits. Extensive simulation results by a simulation program of integrated circuit emphasis (SPICE) indicated that the proposed circuits could compute local velocities of a moving light spot and showed direction selectivity for the moving spot

  • PDF

고압 CV 케이블에서의 부분방전 측정과 위치검출 방법에 관한 연구 (A Study on the measurement and Method of Partial Discharge in High Voltage CV Cable)

  • 송재용;서황동;박대원;길경석;한문섭;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.867-872
    • /
    • 2005
  • This paper describes the measurement and location method of partial discharges in high voltage CV cables. Coupling capacitors were used to detect partial discharge signal. Impedance characteristic of the coupling circuit and an amplifier with a high Common Mode Rejection Ratio(CMRR) were studied to improve sensitivity of the circuit. From the calibration experiment, the sensitivity of the partial discharge detection circuit was about 100pC. Also, we confirmed that the location of partial discharges in cables can be estimated by calculation of time difference between the first pulse and the second one reflected from the other end of the cable.

휴대용 RI 이용 계기의 감마선 검출 회로설계 (The Gamma-Ray Detection Circuit design of RI Use Instrument for Hand Carry)

  • 성낙진;김상진;김기준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 기술교육전문연구회
    • /
    • pp.154-158
    • /
    • 2003
  • In this study, to measure the density of compaction, it is designed to use the 5 gamma-ray detectors. The developed instrument consists of measuring circuits for gamma-rays and thermal neutrons, a high voltage supply unit, stable circuit unit, count circuit unit and a microprocessor. To read count pulse from gamma-ray detectors are very accurate and it can be count to data calibration excluded count of ripple.

  • PDF

BiCMOS 회로의Stuck-Open 고장과 Stuck-On 고장 검출을 위한 테스트 패턴 생성 (Test Pattern Genration for Detection of Stuck-Open and Stuck-On Faults in BiCMOS Circuits)

  • 신재흥;임인칠
    • 전자공학회논문지C
    • /
    • 제34C권1호
    • /
    • pp.1-11
    • /
    • 1997
  • A BiCMOS circuit consists of the CMOS part which performs the logic function, and the bipolar part which drives output load. In BiCMOS circuits, transistor stuck-open faults exhibit delay faults in addition to sequential beavior. Also, stuck-on faults enhanced IDDQ (quiscent power supply current) at steady state. In this paper, a method is proposed which efficiently generates test patterns to detect stuck-open faults and stuck-on faults in BiCMOS circuits. The proposed method divides the BiCMOS circuit into pull-up part and pull-down part, and generates test patterns detect faults occured in each part by structural property of the BiCMOS circuit.

  • PDF

CMOS 회로의 전류 테스팅를 위한 내장형 전류감지기 설계 (Design of a Built-in Current Sensor for Current Testing Method in CMOS VLSI)

  • 김강철;한석붕
    • 전자공학회논문지B
    • /
    • 제32B권11호
    • /
    • pp.1434-1444
    • /
    • 1995
  • Current test has recently been known to be a promising testing method in CMOS VLSI because conventional voltage test can not make sure of the complete detection of bridging, gate-oxide shorts, stuck-open faults and etc. This paper presents a new BIC(built-in current sensor) for the internal current test in CMOS logic circuit. A single phase clock is used in the BIC to reduce the control circuitry of it and to perform a self- testing for a faulty current. The BIC is designed to detect the faulty current at the end of the clock period, so that it can test the CUT(circuit under test) with much longer critical propagation delay time and larger area than conventional BICs. The circuit is composed of 18 devices and verified by using the SPICE simulator.

  • PDF

전력설비 시험시 인적실수 방지를 위한 345kV 모선보호 배전반 회로개선 (Circuit Improvement of 345kV Bus bar protection panel for Human Error Prevention in the event of Field Test)

  • 김인섭;이종석;정시환;강대언;승재현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.675-676
    • /
    • 2007
  • This Paper presents circuit improvement of 345kV Bus bar protection panel by using VDD (Voltage disturbance detection) relay with distinctive ability between human error in the field test and real facility faults. Therefore, We expect that this improvement of circuit helps decrease of blackout coming from human error. In order to guarantee electric power system reliability, consistent study of human error prevention in the event of field test is necessarily required

  • PDF

A Study on the Detection Algorithm of an Advanced Ultrasonic Signal for Hydro-acoustic Releaser

  • Kim, Young-Jin;Huh, Kyung-Moo;Cho, Young-June
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권5호
    • /
    • pp.767-775
    • /
    • 2008
  • Methods used for exploring marine resources and spaces include positioning a probe under water and then recalling it after a specified time. Hydro-acoustic Releasers are commonly used for positioning and retrieving of such exploration equipment. The most important factor in this kind of system is the reliability for recalling the instruments. The frequently used ultrasonic signal detection method can detect ultrasonic signals using a fixed comparator, but because of increased rates of errors due to outside interferences, information is repetitively acquired. This study presents an effective ultrasonic signal detection algorithm using the characteristics of a resonance and adaptive comparator Combined with the FSK+ASK modulator. As a result, approximately 8.8% of ultrasonic wave communication errors caused by background noise and transmission losses were reduced for effectively detecting ultrasonic waves. Furthermore, the resonance circuit's quality factor was enhanced (Q = 120 to 160). As such, the bias voltage of the transistor (Vb= 3.3 to 6.8V) was increased thereby enhancing the frequency's selectivity.

에지완료 검출을 이용한 클럭이 없는 CMOS 웨이브파이프라인 덧셈기 설계 (CMOS Clockless Wave Pipelined Adder Using Edge-Sensing Completion Detection)

  • 안용성;강진구
    • 전기전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.161-165
    • /
    • 2004
  • 본 논문은 CMOS 에지 완료검출 신호를 이용하여 8bit 웨이브파이프라인 덧셈기를 설게하였다. 이 구조는 클럭이 필요 없이 동작한다. 에지감지후 신호완료를 검출하는 알고리즘회로는 센서회로와 래치로 구성되어있다. 제안하는 구조를 이용하여 8bit 덧셈기의 출력이 거의 같은 시간에 만들어 지도록 정렬된다. 시뮬레이션에서 0.35um CMOS 공정을 사용하여 3.3V 공급전압으로 1GHz 동작을 확인하였다.

  • PDF

Islanding Detection Method for Inverter-Based Distributed Generation through Injection of Second Order Harmonic Current

  • Lee, Yoon-Seok;Yang, Won-Mo;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1513-1522
    • /
    • 2018
  • This paper proposes a new islanding detection method for inverter-based distributed generators by continuously injecting a negligible amount of 2nd order harmonic current. The proposed method adopts a proportional resonant (PR) controller for the output current control of the inverter, and a PR filter to extract the 2nd order harmonic voltage at the point of common coupling (PCC). The islanding state can be detected by measuring the magnitude ratio of the 2nd order harmonic voltage to the fundamental voltage at the PCC by injecting a 2nd order harmonic current with a 0.8% magnitude. The proposed method provides accurate and fast detection under grid voltage unbalance and load unbalance. The operation of the proposed method has been verified through simulations and experiments with a 5kW hardware set-up, considering the islanding test circuit suggested in UL1741.

누설자속 탐상법 및 노이즈 필터를 이용한 와이어로프의 결함진단시스템 개발 (A Development of the Fault Detection System of Wire Rope using Magnetic Flux Leakage Inspection Method and Noise Filter)

  • 이영진;아미나;이권순
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.418-424
    • /
    • 2014
  • A large number of wire rope has been used in various industries such as cranes and elevators. When wire used for a long time, wire defects occur such as disconnection and wear. It leads to an accident and damage to life and property. To prevent this accident, we proposed a wire rope fault detection system in this paper. We constructed the whole system choosing the leakage fault detection method using hall sensors and the method is simple and easy maintenance characteristics. Fault diagnosis and analysis were available through analog filter and amplification process. The amplified signal is transmitted to the computer through the data acquisition system. This signal could be obtained improved results through the digital filter process.