• Title/Summary/Keyword: Detailed Analysis

Search Result 5,729, Processing Time 0.033 seconds

Strength Analysis of Bolt Joints for an Open Frame Structure (개방형 프레임 구조물의 볼트 조인트 강도해석)

  • Lee, Jin-Min;Lee, Min-Uk;Cho, Su-Kil;Koo, Man-Hoi;Gimm, Hak-In;Lee, Tae-Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.8
    • /
    • pp.819-825
    • /
    • 2009
  • An open frame structure is fastened by bolt joints for strength and shock attenuation. Therefore the full finite element model of an open frame structure should be properly modeled including bolt joints for strength analysis of the frames and joint assemblies which are operated under multi-loading conditions such as driving, drop, inertia and torsional loads. Then the joints and frames must satisfy the specified allowable strength constraints. Because the full finite element model has a large number of elements to perform strength analysis, a detailed fine bolt analysis seems to be very expensive. Therefore bolts of the full finite element model are approximately modeled by coupling method to constrain degree of freedoms between adjacent nodes. However, the coupling method can exaggerate stress results at the constrained nodes. Thus a detailed bolt analysis and a theoretical/experiential formula of bolts for a worst bolt joint are performed using reaction force applied both bolt and bolt joint. Finally, the results from the two methods are compared and discussed to verify the safety of the open frame structure.

Non-destructive Analysis of Snail Trail on Silver Grid Line in PV Module (비파괴 분석법을 적용한 결정질 태양전지 모듈의 Snail trail 현상 연구)

  • Kim, Dajung;Kim, Namsu;Hwang, Kyung-Jun;Lee, Ju Ho;Jeong, Sinyoung;Jeong, Dae Hong
    • Current Photovoltaic Research
    • /
    • v.2 no.2
    • /
    • pp.63-68
    • /
    • 2014
  • In recent years, discoloration defects, called as snail trail, have been observed at many crystalline photovoltaic modules after a period of time ranging from several months to several years after initial installation. It has been reported that this phenomenon doesn't impact on the performance of photovoltaic modules, but it can be detected through simple visual inspection. The origin and detailed mechanism for the formation have not been identified. In this study, non-destructive analysis by Raman spectroscopy has been carried out to investigate the origin of this phenomenon. In parallel, destructive analysis by scanning electron microscopt and transmission electron microscopy was also performed in order to confirm the results from non-destructive method. Through the extensive analysis, it was found that the main cause for discoloration is the formations of $Ag_2CO_3$ and $AgC_2H_3O_2$. Detailed mechanism for the formation of these particles was indentified through systematic studies.

Public Satisfaction Analysis of Weather Forecast Service by Using Twitter (Twitter를 활용한 기상예보서비스에 대한 사용자들의 만족도 분석)

  • Lee, Ki-Kwang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.41 no.2
    • /
    • pp.9-15
    • /
    • 2018
  • This study is intended to investigate that it is possible to analyze the public awareness and satisfaction of the weather forecast service provided by the Korea Meteorological Administration (KMA) through social media data as a way to overcome limitations of the questionnaire-based survey in the previous research. Sentiment analysis and association rule mining were used for Twitter data containing opinions about the weather forecast service. As a result of sentiment analysis, the frequency of negative opinions was very high, about 75%, relative to positive opinions because of the nature of public services. The detailed analysis shows that a large portion of users are dissatisfied with precipitation forecast and that it is needed to analyze the two kinds of error types of the precipitation forecast, namely, 'False alarm' and 'Miss' in more detail. Therefore, association rule mining was performed on negative tweets for each of these error types. As a result, it was found that a considerable number of complaints occurred when preventive actions were useless because the forecast predicting rain had a 'False alarm' error. In addition, this study found that people's dissatisfaction increased when they experienced inconveniences due to either unpredictable high winds and heavy rains in summer or severe cold in winter, which were missed by weather forecast. This study suggests that the analysis of social media data can provide detailed information about forecast users' opinion in almost real time, which is impossible through survey or interview.

Identifying torsional eccentricity in buildings without performing detailed structural analysis

  • Tamizharasi, G.;Murty, C.V.R.
    • Earthquakes and Structures
    • /
    • v.23 no.3
    • /
    • pp.283-295
    • /
    • 2022
  • Seismic design codes permit the use of Equivalent Static Analysis of buildings considering torsional eccentricity e with dynamic amplification factors on structural eccentricity and some accidental eccentricity. Estimation of e in buildings is not addressed in codes. This paper presents a simple approximate method to estimate e in RC Moment Frame and RC Structural Wall buildings, which required no detailed structural analysis. The method is validated by 3D analysis (using commercial structural analysis software) of a spectrum of building. Results show that dynamic amplification factor should be applied on torsional eccentricity when performing Response Spectrum Analysis also. Also, irregular or mixed modes of oscillation arise in torsionally unsymmetrical buildings owing to poor geometric distribution of mass and stiffness in plan, which is captured by the mass participation ratio. These irregular modes can be avoided in buildings of any plan geometry by limiting the two critical parameters (normalised torsional eccentricity e/B and Natural Period Ratio 𝜏 =T𝜃/T, where B is building lateral dimension, T𝜃 uncoupled torsional natural period and T uncoupled translational natural period). Suggestions are made for new building code provisions.

Realistic thermal analysis of the CANDU spent fuel dry storage canister

  • Tae Gang Lee;Taehyeon Kim;Taehyung Na;Byongjo Yun;Jae Jun Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4597-4606
    • /
    • 2023
  • Thermal analysis of the CANDU spent fuel dry storage canister is very important to ensure the integrity of the spent fuel. The analyses have been conducted using a conservative approach, with a particular focus on the peak cladding temperature (PCT) of the fuel rods in the canister. In this study, we have performed a realistic thermal analysis using a computational fluid dynamics (CFD) code. The canister contains 9 fuel bundle baskets. A detailed analysis of even a single basket requires significant computational resources. To overcome this challenge, we replaced each basket with an equivalent heat conductor (EHC), of which effective thermal conductivity (ETC) is developed from the results of detailed CFD calculations of a fuel bundle basket. Then, we investigated the effects of some conservative models, ultimately aiming at a realistic analysis. The results revealed: (i) The influence of convective heat transfer in the basket cannot be ignored, but it's less significant than expected. (ii) Modeling of the lifting rod is crucial, as it plays a decisive role in axial heat transfer at the center of the canister and significantly reduces the PCT. (iii) Convection within the canister is very important, as it not only reduces the PCT but also shifts its location upwards.

Importance Analysis for Improving the Quality of External Space in Urban Development Projects - Focusing on the Characteristics of Each Job Category - (도시개발사업 시 외부공간의 질적향상을 위한 중요도 분석 - 직군별 특성을 중심으로 -)

  • Lee, Lim-Jung;Kang, min-Sung;Lee, dong-gun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2024
  • This study was motivated by the need to identify the characteristics of professionals involved in planning exterior spaces in urban development projects and to provide guidelines for maintaining the identity of urban images. Urban development's impact on external spaces can alter the image of the urban structure, especially due to the many boundaries between urban and rural areas. Therefore, there is a need for public standards for external spaces in such projects. This study collects and analyzes experts' opinions to understand the characteristics of each professional, selects the relative importance of each, and uses this as a guideline for step-by-step deliberation in planning external spaces. The research scope includes analyzing each expert's characteristics based on the external space evaluation items from Lee Limjeong's 2023 study, which builds upon existing research, and presenting the importance and priority of each expert. As a methodology, a questionnaire was conducted for each expert group using the indicators established in Lee Lim Jung's 2023 study for external spaces in urban development projects. An in-depth analysis was performed using the Analytic Hierarchy Process (AHP) for each expert. Using AHP analysis, the composite weight for each of the 17 detailed items was first adjusted by the number of item weights to account for the classification level of the large and detailed items. Then, the composite importance was calculated by multiplying the importance of the large, medium, and detailed classifications. The calculated composite importance was finally adjusted by applying the number of item weights again, ensuring the sum of the 17 importance values equals 1. The final importance calculated through this process was then presented by occupation.

Parametric Analysis and Design Optimization of a Pyrotechnically Actuated Device

  • Han, Doo-Hee;Sung, Hong-Gye;Jang, Seung-Gyo;Ryu, Byung-Tae
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.3
    • /
    • pp.409-422
    • /
    • 2016
  • A parametric study based on an unsteady mathematical model of a pyrotechnically actuated device was performed for design optimization. The model simulates time histories for the chamber pressure, temperature, mass transfer and pin motion. It is validated through a comparison with experimentally measured pressure and pin displacement. Parametric analyses were conducted to observe the detailed effects of the design parameters using a validated performance analysis code. The detailed effects of the design variables on the performance were evaluated using the one-at-a-time (OAT) method, while the scatter plot method was used to evaluate relative sensitivity. Finally, the design optimization was conducted by employing a genetic algorithm (GA). Six major design parameters for the GA were chosen based on the results of the sensitivity analysis. A fitness function was suggested, which included the following targets: minimum explosive mass for the uniform ignition (small deviation), light casing weight, short operational time, allowable pyrotechnic shock force and finally the designated pin kinetic energy. The propellant mass and cross-sectional area were the first and the second most sensitive parameters, which significantly affected the pin's kinetic energy. Even though the peak chamber pressure decreased, the pin kinetic energy maintained its designated value because the widened pin cross-sectional area induced enough force at low pressure.

Detailed Finite Element Analysis of Full-scale Four-story Steel Frame Structure subjected to Consecutive Ground Motions

  • Tagawa, Hiroyuki;Miyamura, Tomoshi;Yamashita, Takuzo;Kohiyama, Masayuki;Ohsaki, Makoto
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.1
    • /
    • pp.65-73
    • /
    • 2015
  • Detailed finite element (FE) analyses of a full-scale four-story steel frame structure, subjected to consecutive 60% and 100% excitations from the JR Takatori records during the 1995 Hyogoken-Nanbu earthquake, are conducted using E-Simulator. The four-story frame was tested at the largest shake-table facility in the world, E-Defense, in 2007. E-Simulator is a parallel FE analysis software package developed to accurately simulate structural behavior up to collapse by using a fine mesh of solid elements. To reduce computational time in consecutive dynamic time history analyses, static analysis with gravity force is introduced to terminate the vibration of the structure during the analysis of 60% excitation. An overall sway mechanism when subjected to 60% excitation and a story mechanism resulting from local buckling of the first-story columns when subjected to 100% excitation are simulated by using E-Simulator. The story drift response to the consecutive 60% and 100% excitations is slightly smaller than that for the single 100% excitation.

A Content Analysis on the Domestic Public Libraries' Use of Twitter (국내 공공도서관의 트위터 이용에 관한 내용분석)

  • Shim, Jiyoung
    • Journal of the Korean Society for information Management
    • /
    • v.34 no.1
    • /
    • pp.241-262
    • /
    • 2017
  • This study aims to identify and analyze the Twitter use of domestic public libraries. In order to identify the detailed patterns of Twitter use in library and information services, a content analysis was conducted for the 3,038 tweet data from the top 14 public libraries' accounts on Twitter use. Inductive approach was adopted to develop a coding scheme and open coding was conducted with the entire tweet. Additionally, correspondence analysis was conducted for the result of content analysis to identify how library accounts correspond to specific types. As a result, 3 main categories and 9 sub-categories of public libraries' Twitter use were developed. And the 37 detailed patterns of public libraries' use of Twitter were identified. The identified patterns can provide the libraries interested in Twitter use with guidelines.

Effects of Reclosing for Insulation Coordination in 345kV Combined Transmission Lines (345kV 혼합송전선로에서 재폐로가 절연설계에 미치는 영향)

  • Lee, Jong-Beom;Jung, Chae-Kyun;Lim, Kwang-Sik;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.847-853
    • /
    • 2010
  • This paper describes switching surge analysis for reclosing decision in 345kV combined transmission line with XLPE power cable. Reclosing operation should be decided based on the detailed technical analysis in combined transmission line because this line includes power cable section which is week on insulation. Insulation of power cable can be breakdown at the week point in case of reclosing moment. Therefore the detailed analysis has to be carried out by considering several conditions such as length ratio of power cable section, arrestor, inserting resistance, charging rate, grounding resistance, etc.. On the other hand sheath voltage on IJ(Insulated Joint) is analyzed to check dangerous condition on cable cover. Analysis is performed by EMTP/ATP. Analysis results show that reclosing can be operated as the single line-to-ground fault occurs on overhead line in 345kV combined transmission line, if the inserting resistance is considered before the operation of main circuit breaker.