• 제목/요약/키워드: Detail point

검색결과 566건 처리시간 0.027초

IEEE 802.11 무선랜 시스템에서 PCF 프로토콜의 성능을 향상시키기 위한 최적의 폴링 방식 (Optimal Polling Method for Improving PCF MAC Performance in IEEE 802.11 Wireless LANs)

  • 최우용;이상완
    • 대한산업공학회지
    • /
    • 제32권1호
    • /
    • pp.1-8
    • /
    • 2006
  • A modified PCF(Point Coordination Function) protocol with the optimal polling sequence is defined in detail and shown to improve the efficiency of the conventional PCF protocol in IEEE 802.11 wireless LAN standard. The problem for the optimal polling sequence is formulated as TSP(Travelling Salesman Problem) with the distance values of 1's or 0's. Numerical examples show that the optimal polling sequence increases the capacity of the real-time service such as VoIP(Voice over Internet Protocol).

대형 Ingot의 Upset 단조기술에 관한 연구 (A Parametric Study for the Upset Forging of Large Ingot)

  • 박승희;유성만;신상엽
    • 소성∙가공
    • /
    • 제8권1호
    • /
    • pp.101-107
    • /
    • 1999
  • The upset forging stage is the initial work in the forging process. It is used to remove the segregation and cavities of the ingot. Specially in handling large sized ingot, an improper upset forging can cause serious surface tearing. However, there is no detail reference for stable upset forging work. To resolve this difficulty, we studied several factors such as upset forging time, temperature varation of ingot, damage, load and stain rate etc., by using the rigid-plastic finite element approach available in the DEFORM code. Numerical simulation results indicated that: the load value of upset forging works shows severe decreasing trend at a certain point, same as strain rate. Also defects were found to be concentrated around the upper and lower portions of the ingot. With these results, we can estimate a guideline for stable upset forging work.

  • PDF

에폭시 연면거리에 따른 파괴전압 분석 (Analysis of Surface flashover Depending on Gap Distance in Epoxy Region)

  • 윤재훈;이승수;임기조;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.400-400
    • /
    • 2009
  • In a wide variety of high-voltage applications surface flashover plays major role in the system's performance and yet has not been studied in great detail for atmospheric conditions with modem diagnostic tools. surface flashover for both direct current and pulsed voltages in considered. within the setup, parameters such as geometry, material characteristics of the applied voltage can be altered. This paper review surface flashover of insulator, primarily in atmosphere. It discusses theories and models relating to surface flashover and experimental results. surface flashover of insulators in atmosphere generally is initiated by the emission of electrons from the cathode triple junction point (the region where the electrode, insulator, air). the electrode material was copper, and a AC voltage was applied between the electrodes. these results were compared with the surface flashover characteristic of epoxy.

  • PDF

단상 PWM 컨버터의 역률 및 고조파 보상을 위한 교류전압 검출기가 없는 새로운 제어기 (New Controller for Power Factor and Harmonics Compensation of Single-Phase PWM Converter without AC Voltage Sensor)

  • 전영수;백승택;김희중;한병문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.161-165
    • /
    • 2003
  • In this paper, A new controller for power factor and harmonics compensation of a single-phase PWM converter is described. The proposed controller requires only the dc voltage sensor and the at current sensor to compensate the power factor and harmonics. Detail simulation model with EMTBC (Electro-Magnetic Transient program for DC transmission) including power circuit and controller was developed to verify the operation of proposed controller. The application feasibility of the proposed controller was verified through experimental works with a prototype. The proposed controller has a simple structure in the point of hardware implementation, and shows excellent performance in normal operation as well as in sudden load change.

  • PDF

주거공간 분석도구의 개발에 관한 기초적 연구 - 공간구문론을 중심으로 - (A Basic Study on the Development of Logical Tool for Analyzing Spatial Organization of Housing)

  • 이현정;박선경;하재명
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2000년도 학술발표대회논문집
    • /
    • pp.97-102
    • /
    • 2000
  • The final purpose of this study is to develop the synthetic and logical analytical tool for analyzing spatial organization of housing. For this purpose, this study made the starting-point by proposing some alternatives to improve one of the quantitative analytical tools of spatial organizations, Space Syntax. These propositions were intended to consider human behavior as well as physical structure in analyzing spatial organization. The propositions were as follow; 1) Classify the private outdoor space in detail, 2) Consider that the spatial organization which visitors cognize can differ from which residents do, and 3) Use distinctive spatial depth according to the states of connection.

  • PDF

A STUDY ON THE DETERMINATION OF THE INSTANTANEOUS FIELD OF VIEW FOR I-M HIGH RESOLUTION SATELLITE IMAGE

  • Seo Doo-Chun;Park Su-Young;Lee Dong-Han;Lee Sun-Gu;Song Jeong Heon;Lim Hyo-Suk
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.649-652
    • /
    • 2005
  • In this paper we present a detail approach of the determination of IFOV (Instantaneous Field of View) of high-resolution (l m) panchromatic satellite image over test site. IFOV is the representative measurements as the determination of the spatial resolution in remote sensed imaging system. It can be defined as some area on the ground with the particular altitude when the satellite acquires the image at any given time. Especially, spatial resolution of passive sensors primarily depends on their IFOV. The determination of IFOV goes through simple steps of procedure as followings: Firstly, the GSD (Ground Sample Distance) should be computed at each point on the geometrically corrected image. Then, The GSD is converted into the IFOV. So we are going to explain our test procedures and results.

  • PDF

약계자 영역에서 PMSM 드라이브의 최대 토크제어 (Maximum Torque Control of PMSM Drive in Field weakening Region)

  • 이홍균;이정철;김종관;정동화
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.44-49
    • /
    • 2003
  • Permanent magnet synchronous motor(PMSM) is widely used in many applications such as an electric vehicle. compressor drives of air conditioner and machine tool spindle drives. PMSM drive system have become a popular choice in various application, due to their excellent power to weight ratio. This paper is proposed maximum torque control for field weakening operation of PMSM drive. At low speeds, the reluctance torque is used to maximize the output for a given current level. This is achieved maximum torque per ampere(MTPA) by selecting an optimal value of the direct stator current component. At high speeds, the system reaches a point at which the inverter will not be able to supply the desired voltage. In this case it is necessary to make use of an increased value the direct current component. The proposed control algorithm is applied to PMSM drive system, the operating characteristics controlled by maximum torque control are examined in detail by simulation.

A New Single-Phase Asymmetrical Cascaded Multilevel DC-Link Inverter

  • Ahmed, Mahrous;Hendawi, Essam
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1504-1512
    • /
    • 2016
  • This paper presents a new single-phase asymmetrical cascaded multilevel DC-link inverter. The proposed inverter comprises two stages. The main stage of the inverter consists of multiple similar cells, each of which is a half-bridge inverter consisting of two switches and a single DC source. All cells are connected in a cascaded manner with a fixed neutral point. The DC source values are not made equal to increase the performance of the inverter. The second circuit is a folded cascaded H-bridge circuit operating at a line frequency. One of the main advantages of this proposed topology is that it is a modular type and can thus be extended to high stages without changing the configuration of the main stage circuit. Two control schemes, namely, low switching with selective harmonic elimination and sinusoidal pulse width modulation, are employed to validate the proposed topology. The detailed approach of each control scheme and switching pulses are discussed in detail. A 150W prototype of the proposed system is implemented in the laboratory to verify the validity of the proposed topology.

진공에서 절연체의 연면거리에 따른 파괴전압 분석 (Analysis of Surface Flashover Depending on Insulator Gap Distance in Vacuum)

  • 윤재훈;임종남;임기조;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1471_1472
    • /
    • 2009
  • In a wide variety of high-voltage applications surface flashover plays major role in the system's performance and yet has not been studied in great detail for vacuum conditions with modern diagnostic tools. surface flashover for both direct current and pulsed voltages in considered. within the setup, parameters such as geometry, material characteristics of the applied voltage can be altered. This paper review surface flashover of insulator, primarily in vacuum. It discusses theories and models relating to surface flashover and experimental results. surface flashover of insulators in vacuum generally is initiated by the emission of electrons from the cathode triple junction point (the region where the electrode, insulator, vacuum). the electrode material was copper, and a AC voltage was applied between the electrodes. these results were compared with the surface flashover characteristic of insulator at results, surface flashover influenced only insulator surface condition. and increasing vacuum pressure was risen breakdown voltage.

  • PDF

Maximum Efficiency Operation of Three-Level T-type Inverter for Low-Voltage and Low-Power Home Appliances

  • Shin, Seung-Min;Ahn, Jung-Hoon;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.586-594
    • /
    • 2015
  • This paper proposes a maximum efficiency operation strategy for three-level T-type inverter in entire operation areas. The three-level T-type inverter has higher and lower efficiency areas compared with two-level inverter. The proposed strategy aims to operate in the maximum efficiency point for the low-voltage and low-power home appliances. The three-level T-type inverter is analyzed in detail, and the two operation mode selection strategy is developed. The proposed algorithm is verified by theoretical analysis and experimental results.