• Title/Summary/Keyword: Design perfomance

Search Result 32, Processing Time 0.023 seconds

Sensitivity Analysis of Shape Design Parameters of a Toque Converter Using Potential Flow (포텐셜 유동 해석을 이용한 토크 컨버터의 형상설계 파라미터들의 민감도 해석)

  • 김준양;이장무;박찬일;임원식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.924-929
    • /
    • 1994
  • In using a performance model of a torque converter determined by its gemetric condition, it is possible that the analysis of two arbitrary converters produces the the same results because of the same value of equivalent parameters despite their different shapes. Therefore, it is necessary to understand the effect of shape factor on dynamic perfomance, and equivalent parameters reoresenting a performace model of a converter should into its defined by the behavior of flow field. In this study, torus flow of a torque converter is changed into its equivalent system defined by the behavior of flow, and govering equations for the system are presented and used for analysis. Equivalent parameters are obtained from the results of flow analysis and are compared with parameters of one dimensional performance model. The influence that shape change of a converter has on the behavior of flow and the equivalent parameters is studied qualitatively.

  • PDF

An Experimental Study on Thermal and Environmental Characteristics of Various Heating Systems in the Residential House (주거용 건물의 난방 방식별 열적성능 및 실내환경 특성 평가를 위한 실험적 연구)

  • Lee, Choong-Kook;Cho, Sung-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.121-128
    • /
    • 2005
  • This is about experimental comparison study between convective heating and radiation heating system to use the design criteria for residential house. Experiment was done in EC(environment chamber) under simultaneous outdoor condition for 4 kinds of heating system such as CRHP(Ceiling Radiant Heating Panel), BEHC( Bottom Electric Heating Coil Mat), EFCU( Electric Fan Coil Unit) and CEHU( Convective Electric Heating Unit). Result show that CRHP ,which is radiation heating system, can consume more 23% energy than convective heating system when it is operated by dry bulb temperature but can save 1 ${\sim}$ 10% when operated by glove temperature and 27% when operated by MRT.

  • PDF

Design and Application of Gradient-descent-based Self-organizing Fuzzy Logic Controller (그래디언트 감소를 기반으로하는 자기구성 퍼지 제어기의 설계 및 응용)

  • 소상호;박동조
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.10a
    • /
    • pp.191-196
    • /
    • 1998
  • A new Fuzzy Logic Controller(FLC) called a Gradient-Descent Based Self-Organizing Controller is presented. The Self-Organizing Controller(SOC) has two inputs such as error and change of error, and updates control rules with monitoring a performance measure. There are many works in the SOC which concentrate on the self-organizing ability in control rule base, but have a few research on the performance measure which is akin to sliding mode control. With this procedure, we can get a robust performance measure on the SOC. To verify the perfomance of proposed controller, we have performed for the cart-pole system which is one of the well-known benchmark problem in the control literature.

  • PDF

Performance Management of Communication Networks for Computer Intergrated Manufacturing (컴퓨터 통합 생산을 위한 통신망의 성능 관리)

  • Lee, S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.4
    • /
    • pp.126-137
    • /
    • 1994
  • Performance management of computer networks is intended to improve a given network performance in order for more efficient information exchange between subsystems of an integrated large-scale system. Importance of perfomance management is growing as many functions of the large- scale system depend on the quality of communication services provided by the network. The role of performance management is to manipulate the adjustable protocol parameters on line so that the network can adapt itself to a dynamic environment. This can be divided into two subtasks : performance evaluation to find how changes in protocol parameters affect the network performance and decision making to determine the magnitude and direction of parameter adjustment. This paper is the first part of the two papers focusing on conceptual design, development, and evaluation of performance management for token bus networks. This paper specifically deals with the task of performance evaluation which utilizes the principle of perturbation analysis of discrete event dynamic systems. The developed algorithm can estimate the network performance under a perturbed protocol parameter setting from observations of the network operations under a nominal parameter setting.

  • PDF

Application of Performance Based Mixture Design (PBMD) for High Strength Concrete (고강도 콘크리트의 성능기반형 배합설계방법)

  • Kim, Jang-Ho Jay;Oh, Il Sun;Phan, Duc Hung;Lee, Keun Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6A
    • /
    • pp.561-572
    • /
    • 2010
  • This paper is a study about application of recently proposed Performance Based Mixture Design (PBMD) for design of high strength concrete (HSC) to obtain HSC mix proportion that satisfies required performances. The PBMD method which uses Satisfaction curve based on a Bayesian method is a performance oriented concrete mix proportion design procedure easily applicable to any condition and environment for a possible replacement to the current prescriptive design standards. Based on extensive experimental results obtained for various materials and performance parameters of HSC, the application feasibility of the developed PBMD procedure for HSC has been verified. Also, the proposed PBMD procedure has been used to perform application examples to obtain desired target performances of HSC with optimum concrete mixture proportions using locally available materials, local environmental conditions, and available concrete production technologies. The validity and precision of HSC mix proportion design obtained using the PBMD method is verified with the experimental and ACI presented results to check the feasibility for actual design usage.

Design and Performance Prediction of Small Hydropower Plant Using Treated Effluent in Wastewater Treatment Plant (하수처리수를 이용한 소수력발전소 설계 및 성능예측)

  • Lee, Chul-Hyung;Park, Wan-Soon;Kim, Won-Kyoung;Kim, Jeong-Yeon;Chae, Kyu-Jung
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.78-83
    • /
    • 2013
  • A methodology to predict the output performance of small hydro power plant using treated effluent in waste water treatment plant has been studied. Existing waste water treatment plant located in Kyunggi-Do were selected and the output performance characteristics for these plants were analyzed. .Based on the models developed in this study, the hydrologic performance characteristics for SHP sites have been analyzed. The results show that the flow duration characteristics of small hydropower plant for waste water treatment plant have quite differences compared with small hydropower plant for the river. As a result, it was found that the developed model in this study can be used to analyze the output characteristics for small hydro power in waste water treatment plant. Additionally, primary design specifications such as design flowrate, capacity, operational rate and annual electricity production were estimated and discussed. It was found that the models developed in this study can be used to decide the design performance of small hydropower plant for waste water treatment plant effectively.

Design and Implementation of a Parallel Computer "KAPAC" (병렬 컴퓨터 “KAPAC”의 설계 및 구현)

  • 성동수;강휘삼;최승욱;박규호
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.29B no.4
    • /
    • pp.1-11
    • /
    • 1992
  • A parallel computer "KAPAC(KAIST Parallel Computer)" based on Transputer is designed and implemented. Its purpose is to support the real time processing and high perfomance computing through parallelizing the complex and heavy computation load. KAPAC has UNIX machine as host-computer and is implemented on VME bus as back-end machine. The parallel computer "KAPAC" is the message-passing loosely-coupled multiprocessor computer having thirty two processing elements, and the network topology between processing elements can be easily configured with the crossbar switchs using the control program. Various topologies are introduced and appoication programs are executed on the parallel computer "KAPAC" with eifferent interconnection topologies to show the reconfigurability.to show the reconfigurability.

  • PDF

Relationship of TQM on Managerial Perfomance: Evidence From Property Sector in Indonesia

  • FIRMAN, Ahmad;MUSTAPA, Zainuddin;ILYAS, Gunawan Bata;PUTRA, Aditya Halim Perdana Kusuma
    • Journal of Distribution Science
    • /
    • v.18 no.1
    • /
    • pp.47-57
    • /
    • 2020
  • Purpose: This study seeks to bridge between the research by Lawrence (1999) and Retegan (1992), where the focus of TQM on his studies rests on customer satisfaction. Whereas in this study trying to recompile TQM by involving the variables Innovation and competitive advantage to stimulate managerial performance improvement where performance measurements include various measurements such as financial performance, marketing performance, and production performance in the property industry. Research design, data, and methodology: Total sample are 105 respondents coming from middle to top level of management in the property sector in Indonesia. To empirically prove the results of this study using multiply regression analysis as a test tool for analysis. Results and Findings: The results of this study confirm that TQM has a positive effect on market competition, innovation, and company performance indirectly. However, it does not have a significant impact if it is directly related to TQM on company performance. In this case, TQM for property companies in Indonesia would not have been possible without the role of innovation and market competition. So that the managerial implications of this study also confirm that TQM is essential and feels obligatory to be implemented optimally.

Perfomance Evaluation of efficient group design Using Hierarchical MPLS (계층형MPLS를 이용한 계층간의 효율적인 구성에 관한 연구)

  • Kim, Ki-Yong;Jang, Jong-Wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.58-62
    • /
    • 2007
  • Recnetly, the demands of QoS(Quality of Service) and the traffic in network is increased. So, H-MPLS(Hierarchical MPLS) network research what guarantees the scalability is in progress. But, the H-MPLS has a problem of increasing of groups and the links of these group's nodes. It happens a problem that is increasing of H-MPLS setup cost. In this paper, We setup the H-MPLS groups. We use NS simulator in order to analyze the performance and traffic transfer times of each H-MPLS groups. In conclusion, we can find out the elevation of the traffic performance, by increasing a amount of links.

  • PDF

Performance Evaluation of the Cast-in-place Anchor Bolt in Non-cracked Concrete used in Power Plant Facilities (비균열 콘크리트에 매립된 발전설비 정착부 선 설치 앵커의 구조성능 평가)

  • Kim, Dong-Ik;Jong, Woo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.250-258
    • /
    • 2019
  • The seismic performance and stability of operating facilities installed in domestic power plants need to be verified because of the increased incidence of earthquakes resulting in power plant damage due to the overturning failure of electric operating facilities. In this study, a structural performance evaluation of the anchor bolts constructed to setup the operating facilities on concrete slabs was carried out through an on-site inspection of power plants, called Daechung-Dam. M10 J hook and M12 J hook anchor bolts were installed in the field unit. According to the ASTM E 488-96 specifications, anchor bolt pullout and shear tests were carried out and compared with the anchor-bolt design standards. The results from the tension and shear pullout tests showed that the M10 and M12 J hook anchor bolts had higher performance than the required design load. Thus, they were found to be safe enough. Nevertheless, more research in the field of analytical study will be needed in the near future.