• Title/Summary/Keyword: Design pattern

Search Result 5,533, Processing Time 0.037 seconds

Base isolation performance of a cone-type friction pendulum bearing system

  • Jeon, Bub-Gyu;Chang, Sung-Jin;Kim, Sung-Wan;Kim, Nam-Sik
    • Structural Engineering and Mechanics
    • /
    • v.53 no.2
    • /
    • pp.227-248
    • /
    • 2015
  • A CFPBS (Cone-type Friction Pendulum Bearing System) was developed to control the acceleration delivered to a structure to prevent the damage and degradation of critical communication equipment during earthquakes. This study evaluated the isolation performance of the CFPBS by numerical analysis. The CFPBS was manufactured in the shape of a cone differenced with the existing FPS (Friction Pendulum System), and a pattern was engraved on the friction surface. The natural frequencies of the CFPBS were evaluated from a free-vibration test with a seismic isolator system consisting of 4 CFPBS. To confirm the earthquake-resistant performance, a numerical analysis program was prepared using the equation of the CFPBS induced from the equations of motion. The equation reported by Tsai for the rolling-type seismic isolation bearings was proposed to design the equation of the CFPBS. Artificial seismic waves that satisfy the maximum earthquake scale of the Korean Building Code-Structural (KBC-2005) were created and verified to review the earthquake-resistant performance of the CFPBS by numerical analysis. The superstructural mass of the CFPBS and the skew angle of friction surface were considered for numerical analysis with El Centro NS, Kobe NS and artificial seismic waves. The CFPBS isolation performance evaluation was based on the numerical analysis results, and comparative analysis was performed between the results from numerical analysis and simplified theoretical equation under the same conditions. The validity of numerical analysis was verified from the shaking table test.

Open-jet boundary-layer processes for aerodynamic testing of low-rise buildings

  • Gol-Zaroudi, Hamzeh;Aly, Aly-Mousaad
    • Wind and Structures
    • /
    • v.25 no.3
    • /
    • pp.233-259
    • /
    • 2017
  • Investigations on simulated near-surface atmospheric boundary layer (ABL) in an open-jet facility are carried out by conducting experimental tests on small-scale models of low-rise buildings. The objectives of the current study are: (1) to determine the optimal location of test buildings from the exit of the open-jet facility, and (2) to investigate the scale effect on the aerodynamic pressure characteristics. Based on the results, the newly built open-jet facility is well capable of producing mean wind speed and turbulence profiles representing open-terrain conditions. The results show that the proximity of the test model to the open-jet governs the length of the separation bubble as well as the peak roof pressures. However, test models placed at a horizontal distance of 2.5H (H is height of the wind field) from the exit of the open-jet, with a width that is half the width of the wind field and a length of 1H, have consistent mean and peak pressure coefficients when compared with available results from wind tunnel testing. In addition, testing models with as large as 16% blockage ratio is feasible within the open-jet facility. This reveals the importance of open-jet facilities as a robust tool to alleviate the scale restrictions involved in physical investigations of flow pattern around civil engineering structures. The results and findings of this study are useful for putting forward recommendations and guidelines for testing protocols at open-jet facilities, eventually helping the progress of enhanced standard provisions on the design of low-rise buildings for wind.

Temperature Evaluation on Long-term Storage of Radioactive Waste Produced in the Process of Isotope Production (동위원소 생산공정에서 발생한 방사성 폐기물 장기저장소 온도평가)

  • Jeong, Namgyun;Jo, Daeseong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.7
    • /
    • pp.471-475
    • /
    • 2016
  • In the present study, temperature evaluations on long-term storage of radioactive waste produced in the process of isotope production were performed using two different methods. Three-dimensional analysis was carried out assuming a volumetric heat source, while two-dimensional studies were performed assuming a point source. The maximum temperature difference between the predictions of the volumetric and point source models was approximately $5^{\circ}C$. For the conceptual design level, a point source model may be suitable to obtain the overall temperature characteristics of different loading locations. For more detailed analysis, the model with the volumetric source may be applicable to optimize the loading pattern in order to obtain minimum temperatures.

Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System (중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석)

  • Kim, Kyu-Saeng;Lee, Sang-Hyeok;Hong, Kyung-Pyo;Won, Young-Jae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

Comparison of Sleep Patterns between Home and Institute Elderly People (재가노인과 시설노인의 수면양상에 대한 비교연구)

  • Kim, Kwuy-Bun;Sok, So-Hyune;Kim, In-Sook
    • Journal of East-West Nursing Research
    • /
    • v.5 no.1
    • /
    • pp.65-74
    • /
    • 2000
  • This study was attempted to show basic data for search of nursing intervention about sleep improving in home and institute elderly peoples. Research design was cross-sectional survey method for comparison of sleep patterns and another variables between home and institute elderly peoples. Subjects were sampled by purpose as home and institute elderly peoples at age of 65 or older in Seoul or nearly. The survey questionnaire was used by modification of sleep questionnaire which Kim, O, Song & Bak(1997) developed. Data were collected between December, 1999 and April, 2000. And data were analyzed by SPSS PC+ for purpose of research. Results are as follows: 1. Home and institute elderly peoples, all were change of sleep patterns and sleep pattern was showed early sleeping down. But institute elderly peoples slept earlier than home elderly peoples. 2. As rest of morning, difficulty of falling asleep and disturbance of re-asleep, subjective thinking and feeling were showed more negative thing home elderly peoples than institute elderly peoples. As frequency of falling asleep within 5 min in 1 week, frequency of falling asleep over 30 min in 1 week and frequency of awakening in a day, objective frequency were showed more insomnia institute elderly peoples than home elderly peoples. Home elderly peoples didn't nap most and institute elderly peoples napped on very short time. 3. Regarding sleep-disturbing factors, physical factor was popularly joint-disturbance in all, home and institute elderly peoples. Environmental factor was popularly noise, particularly institute elderly peoples. Emotional factor wasn't all. 4. Practiced strategies for better sleep was popularly TV/Radio in home elderly peoples and were popularly regular sleep and religious action in institute elderly peoples. From the results of this study, home elderly peoples need nursing intervention of improving self-satisfaction on sleep and institute elderly peoples need nursing intervention of decreasing falling asleep-disturbing and decreasing frequency of awakening in sleep.

  • PDF

Design and Fabrication of a Wide Band and Multi-Resonation Planar Antenna (광대역 다중공진 평판 안테나 설계 및 구현)

  • Lee, Hyeon-Jin;Park, Seong-Il;Lim, Yeong-Seog
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.12
    • /
    • pp.171-176
    • /
    • 2005
  • This study designed and fabricated a multi-purpose planar antenna for base stations that are accessible to DCS, WiBro, and ISM. The proposed antenna was designed into an open loop form from the existing monopole structure. The capacitance of the multi-purpose antenna was increased by the coupling of open parts. This makes the use of MMIC and LTCC convenient and the antenna is smaller and has a larger gain than existing antennas. The resonance distance and bandwidth can be adjusted by changing the open gap and the height of the loop of the antenna. The bandwidth of the designed antenna satisfies DCS, IMT-2000, WiBro, Bluetooth, wireless LAN and ISM bands based on VSWR 2. The entire frequency bandwidth is $58.75\%$ of $1.575GHz\~2.985GHz(1.41GHz)$. Also, the radiation pattern of the antenna displayed co-polarization and cross-polarization characteristics at 1.6GHz, 2.3GHz and 2.8GHz.

Effects of Body Position and Time after Feeding on Gastric Residuals in LBW Infants

  • Hwang, Sun-Kyung;Ju, Hyun-Ok;Kim, Young-Soon;Lee, Hwa-Za;Kim, Young-Hae
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.4
    • /
    • pp.488-494
    • /
    • 2003
  • Purpose. To examine the effects of body position and time after feeding on gastric residuals in low birth weight infants(LBW). Methods. A repeated measures design was conducted. Twenty LBW infants being fed via indwelling nasogastric tubes were randomly assigned to one of 5 different position orderings. In each position, gastric residuals were measured at 30, 60, 90, 120, 150, and 180 minutes after feeding. Results. In comparisons of gastric residuals with position and time, the main effects of position and time were statistically significant (F=5.038, p=0.001; F=429.763, p < 0.001, respectively), but the interaction between position and time was found not to be significant. In pairwise comparisons, the gastric residuals were more reduced in the right anterior oblique and prone positions compared with the left lateral position (p < 0.05) and the differences across time periods were significant (p < 0.001). Conclusions. The body position after feeding has a significant affect on gastric residuals over time in LBW infants. The right anterior oblique or prone position is recommended rather than left lateral position after feeding. Knowledge of the proper position and the pattern of gastric emptying over time after feeding may lead to the development of evidence-based nursing care.

The Wide-band and High-gain Strip Patch Antenna coupled with a H-shaped Aperture (H모양 개구면에 스트립 급전된 광대역 및 고이득 패치 안테나)

  • Shin, Ho-Sub;Kim, Nam
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.4
    • /
    • pp.27-37
    • /
    • 2001
  • The design, fabrication, and an experimental implementation of the strip patch antenna coupled with a H-shaped aperture arc presented in this paper. The proposed antenna has the wide bandwidth, high gain, and low cross-polarization levels. We measured the VSWR, smith chart impedance characteristic, co/cross polarization pattern, gain, and so on. The measured bandwidth of this antenna is 47.1 %. To reduce the back lobe and increase the gain, when the reflector is used, cross polarization level is below -18.2dB at E-plane and below 25.7 dB at H -plane. The maximum gain at 2.05 GHz is also 10.4 dBi and the 3 dB gain bandwidth with center frequency at 2.17 GHz is 24 %, which is the wide bandwidth. This antenna can find applications in mobile communication, wireless LAN, RF communication system, and so on.

  • PDF

Effects of Windbreak Planting on Crop Productivity for Agroforestry Practices in a Semi-Arid Region

  • Jo, Hyun-Kil;Park, Hye-Mi
    • Journal of Forest and Environmental Science
    • /
    • v.33 no.4
    • /
    • pp.348-354
    • /
    • 2017
  • Agroforestry has been practiced in arid and semi-arid regions for the purposes of preventing desertification and to increase income for locals. However, the intended effects of such practices have been limited due to strong winds and aridity. This study undertook multi-year monitoring of the productivity of income crops associated with windbreak planting in a semi-arid region of Mongolia, and explored strategies of windbreak planning to enhance the multi-purpose effects of agroforestry practices. The tree crown density of windbreak planting was on average 40% in one year after planting and 65% 2-3 years after, and thereby windspeeds were reduced by about 30% and 54%, respectively. Average windspeed reductions at leeward distances from the windbreak planting were approximately 60% within 3H (H=tree height), 50% at 5H, and 42% at 7-9H, presenting a pattern in which the farther the distance the less the reduction in windspeeds. The windbreak planting increased crop productivity by up to 6.8 times, compared to the productivity absent of windbreaks. Increases in the crown density as stated above resulted in increases of crop productivity by up to 3.6 times. Based on such results, this study proposed a model of windbreak planning as a typical land-use system of border windbreak planting or alternate windbreak planting of combining trees and income crops. The model also included tree planting with a crown density of 60% and allocation of income crops within a leeward distance of 5 times the height of the trees to reduce windspeeds by about 50%. The results from this study are applicable to practicing agroforestry not only at the study site but also in other regions worldwide where strong winds and aridity are problematic.

Analysis of Low Frequency Noise Variation in Temperature Sensor With Bi2Mg2/3Nb4/3O7 (Bi2Mg2/3Nb4/3O7을 사용한 온도센서의 저주파 잡음 특성)

  • Cho, Il Hwan;Seo, Dongsun
    • Journal of IKEEE
    • /
    • v.19 no.4
    • /
    • pp.486-490
    • /
    • 2015
  • Sensitivity characteristics of temperature sensor with $Bi_2Mg_{2/3}Nb_{4/3}O_7$ (BMNO) layer were investigated with low frequency noise measurement. Temperature sensor with BMNO layer had high reliability and high sensitivity comparing with conventional MOS type temperature sensor. Annealing temperature variation effects with $600^{\circ}C$, $700^{\circ}C$ and $800^{\circ}C$ were measured and analyzed. Annealing temperature determines trap distribution and $700^{\circ}C$ annealing sample has different pattern comparing with other samples. Results of low frequency noise can offer the design guide of temperature sensor performance.