• Title/Summary/Keyword: Design of Generator

Search Result 2,017, Processing Time 0.024 seconds

Sensorless Diagnosis Method and Characteristic Analysis of Short-Circuited Turn for Generator Rotor (발전기 회전자의 층간단락 센서리스 진단기법 및 특성 해석)

  • Kim Sun-Ja;Jeon Yoon-Seok;Lee Seung-Hak;Choe Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.210-213
    • /
    • 2003
  • Short-circuited can have significant effects on a generator and its performance. One of effective method detecting inter-turn short circuits on round rotor winding is a method using sensor detecting. But the method needs duplicate design of sensor for characteristic change according to types and forms of generator. Thus rotor shorted-turn diagnosis method without sensor is needed for detecting short turn when generator is driven. Diagnosis method without sensor depend on change of electric property in generator For the reason, this paper presents characteristic analysis of shorted-turns in generator by detecting the output voltage of generator.

  • PDF

Structural optimization for rotor frame of 750kW gearless type PMSG (750kW Gearless PM 동기발전기 로터프레임 경량화)

  • Hong, Hyeok-Soo;Park, Jin-Il;Ryu, Ji-Yune
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.286-289
    • /
    • 2008
  • Mass of generator is one of the most important characteristic value especially direct drive type wind turbine. This paper introduce how to decease mass of generator rotor frame without declining generator performance. To obtain optimal design of rotor frame, sensitivity analysis using Taguchi method and RSM(response surface method) are have been performed.

  • PDF

Development of a thermal-hydraulic analysis code for once-through steam generators using straight tubes for SMRs (일체형 원자로용 관류식 직관형 증기발생기 열수력 해석 코드 개발)

  • Park, Youngjae;Kim, Iljin;Kang, Kyungjun;Kang, Hanok;Kim, Youngin;Kim, Hyungdae
    • Journal of Energy Engineering
    • /
    • v.24 no.2
    • /
    • pp.91-102
    • /
    • 2015
  • A thermal-hydraulic design and performance analysis computer code for a once-through steam generator using straight tubes is developed. To benchmark the developed physical models and computer code, an once-through steam generator developed by other designer is simulated and the calculated results are compared with the design data. Also, the same steam generator is analyzed with the best-estimate thermal-hydraulic system code, MARS, for the code-to-code validation. The overall characteristics of heat transfer area, pressure and temperature distributions calculated by the developed code show general agreements with the published design data as well as the analysis results of MARS. It is demonstrated that the developed code can be utilized for diverse purposes, such as, sensitivity analyses and optimum thermal design of a once-through steam generator.

Design of Sludge Washing Apparatus in Steam Generator and Control Method (증기발생기의 슬러지 세척장치 설계 및 제어방법)

  • Kim, Joeng-Hoon;Bae, Yong-Han;Kwon, Soon-Ryang
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.10
    • /
    • pp.68-77
    • /
    • 2010
  • In the case of operating steam generators for long periods in nuclear power plants, sludge is accumulated inside the steam generator. This phenomenon could adversely affect the operation of the steam generator. This paper is about the design of a sludge washing apparatus which can remove the sludge efficiently and the control methods of the apparatus. In this paper, to design the sludge washing apparatus, firstly, we design nozzles for spraying high-pressure water through applying mathematical models and lab tests. Secondly, we establish the mathematical theory for performance parameters required to drive the sludge washing apparatus. Thirdly, we design physical structures of the apparatus based on the established performance parameters. Finally, we present the control methods of the apparatus. The sludge washing apparatus presented in this paper moves along the walls of the steam generator according to cracks in the tube array, and spray the high pressure water to remove the sludge. By this way, a relatively large amount of sludge formed in the inner surfaces can be washed very effectively.

Hydrogen Peroxide Gas Generator Design and Investigation of Power Measurement Method Utilizing Turbocharger (과산화수소 가스발생기 설계와 터보차저를 이용한 동력 측정 방법 검토)

  • Park, Dae-Jong;An, Sung-Yong;Kwon, Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.41-44
    • /
    • 2008
  • In this paper, the gas generator using hydrogen peroxide catalytic decomposition was designed for turbine generator operation. The gas generator used 90wt% rocket-grade of hydrogen peroxide and manganese dioxide as a catalyst. Turbine generators utilizing gas generators were investigated and the prestudy was prepared using automobile turbocharger instead of turbine generator.

  • PDF

Design of High Efficiency Permanent Magnet Synchronous Generator for Application of Waste Heat Generation ORC System (폐열발전 ORC 시스템 적용을 위한 고효율 영구자석형 동기발전기 설계)

  • Yeong-Jung Kim;Seung-Jin Yang;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2023
  • The power generation method using expensive diesel has operation problems such as high cost diesel generator and a lack of reserved power due to increase of power demand in some islands, requiring expansion of power generation facilities. To solve this problems, it is necessary to improve the efficiency of power generation facilities through an ORC(Organic Rankin Cycle) system application that uses waste heat as a heat source. Therefore, localized application technology of price competitive and highly reliable ORC power generation system is needed, and optimization technology of generators is having great effect, so this study performed two generator designs to get a high-efficiency generator with an optimized 30kW output. The comparison of simulation data for two designed models showed that a generator with SPM factor of 46.2% had an efficiency of 92.1% and a power ouput of about 23.2kW based on 12,000rpm, a generator with SPM factor of 44.46%, had a power output of 27.9kW and efficiency of 93.6% based on above rpm. For the verification of improved design model with SPM factor of 44.46%, the prototype test system with 110kW motor dynamometer was installed and got to the efficiency of 92.08% with conditions of the rated capacity 25kW at 12,000rpm, the test results of prototype generator showed the validity of generator design.

Analysis and Design of Resonant Inverter for Reactive Gas Generator Considering Characteristics of Plasma Load

  • Ahn, Hyo Min;Sung, Won-Yong;Lee, Byoung Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.345-351
    • /
    • 2018
  • This paper analyzes a resonant inverter to generate plasma. The resonant inverter consists of a full bridge converter, resonant network and reactor to generate a magnetic field for plasma generation. A plasma load has very distinct characteristics compared to conventional loads. The characteristics of plasma load are analyzed through experimental results. This paper presents the study on the resonant network, which was performed in order to determine how to achieve a constant current gain. Another important contribution of this study is the analysis of drop-out phenomenon observed in plasma loads which is responsible for unpredictable shutdown of the plasma generator that requires stable operation. In addition, the design process for the resonant network of a plasma generator is proposed. The validity of this study is verified through simulations and experimental results.

Reliability Evaluation of Torque Generator (토크 발생기의 신뢰성 향상)

  • Jung, D.S.;Lee, Y.B.;Park, J.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.6
    • /
    • pp.59-65
    • /
    • 2012
  • Torque Generator is a product which has function to transform hydraulic energy to mechanical energy of torque and rotating speed, and be used for direction change device of agricultural machines. This study proposes failure analysis and test analysis on torque generator and introduces a process that reliability of a product is enhanced by design improvement. And also it presents improvements of maximum output torque by modifying design and surface treatment. Lastly it verifies reliability improvement by analyzing test results of before and after life test.

Calculation of the generator cost functions using the utilization factor of generators and the mixed fuel burning ratio of the generators (이용율과 혼소율을 이용한 발전기의 입출력 특성식 산정)

  • Song, Kyung-Bin;Nam, Jae-Hyun;Park, Si-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1270-1272
    • /
    • 1999
  • The generator cost function is one of the basic data for the generation scheduling. Generally the cost functions are obtained form design calculations or from heat rate tests. The real operating condition may be different from the condition of design or the tests. Some of the conditions may not be tested during the periodical maintenance. In order to improve the calculation of the generator cost function, this paper presents a new calculation method of the generator cost functions using the utilization factors of generators and the mixed fuel burning ratio of the generators.

  • PDF

Design of Control System for 1kW Grid-connected Permanent Magnet Synchronous Generator (가스 엔진용 1kW급 계통 연계 영구자석형 동기발전기 구동 시스템 설계)

  • Lee, Taeyeong;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.69-70
    • /
    • 2017
  • This paper presents design of control system for permanent magnet synchronous generator(PMSG). The gas engine make rotating mechanical energy from gas fuel energy. The rotor of synchronous generator is connected to axis of engine. And it converts the mechanical energy to the electrical energy. The control system of PMSG helps the electrical energy to flow to grid. the single phase pfc rectifier controls the DC-link voltage by controlling the current of filter inductor. If the DC-link voltage is higher than the voltage reference, the filter current could be controlled to flow to grid. The three phase inverter controls the stator current of generator. The direction of the current is controlled depends on motoring or generating mode. The feasibility of the grid-connected PMSG is verified by the experimental results with 1kW prototype.

  • PDF