• Title/Summary/Keyword: Design and Fabrication

Search Result 2,714, Processing Time 0.028 seconds

IGRINS Design and Performance Report

  • Park, Chan;Jaffe, Daniel T.;Yuk, In-Soo;Chun, Moo-Young;Pak, Soojong;Kim, Kang-Min;Pavel, Michael;Lee, Hanshin;Oh, Heeyoung;Jeong, Ueejeong;Sim, Chae Kyung;Lee, Hye-In;Le, Huynh Anh Nguyen;Strubhar, Joseph;Gully-Santiago, Michael;Oh, Jae Sok;Cha, Sang-Mok;Moon, Bongkon;Park, Kwijong;Brooks, Cynthia;Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyuong;Hill, Peter C.;Lee, Sungho;Barnes, Stuart;Yu, Young Sam;Kaplan, Kyle;Mace, Gregory;Kim, Hwihyun;Lee, Jae-Joon;Hwang, Narae;Kang, Wonseok;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.90-90
    • /
    • 2014
  • The Immersion Grating Infrared Spectrometer (IGRINS) is the first astronomical spectrograph that uses a silicon immersion grating as its dispersive element. IGRINS fully covers the H and K band atmospheric transmission windows in a single exposure. It is a compact high-resolution cross-dispersion spectrometer whose resolving power R is 40,000. An individual volume phase holographic grating serves as a secondary dispersing element for each of the H and K spectrograph arms. On the 2.7m Harlan J. Smith telescope at the McDonald Observatory, the slit size is $1^{{\prime}{\prime}}{\times}15^{{\prime}{\prime}}$. IGRINS has a plate scale of 0.27" pixel-1 on a $2048{\times}2048$ pixel Teledyne Scientific & Imaging HAWAII-2RG detector with a SIDECAR ASIC cryogenic controller. The instrument includes four subsystems; a calibration unit, an input relay optics module, a slit-viewing camera, and nearly identical H and K spectrograph modules. The use of a silicon immersion grating and a compact white pupil design allows the spectrograph collimated beam size to be 25mm, which permits the entire cryogenic system to be contained in a moderately sized ($0.96m{\times}0.6m{\times}0.38m$) rectangular Dewar. The fabrication and assembly of the optical and mechanical components were completed in 2013. From January to July of this year, we completed the system optical alignment and carried out commissioning observations on three runs to improve the efficiency of the instrument software and hardware. We describe the major design characteristics of the instrument including the system requirements and the technical strategy to meet them. We also present the instrumental performance test results derived from the commissioning runs at the McDonald Observatory.

  • PDF

Cases of Ethical Violation in Research Publications: Through Editorial Decision Making Process (편집심사업무 관점에서 학술지 윤리강화를 위한 표절 검증사례)

  • Hwang, Hee-Joong;Lee, Jung-Wan;Kim, Dong-Ho;Shin, Dong-Jin;Kim, Byoung-Goo;Kim, Tae-Joong;Lee, Yong-Ki;Kim, Wan-Ki;Youn, Myoung-Kil
    • Journal of Distribution Science
    • /
    • v.15 no.5
    • /
    • pp.49-52
    • /
    • 2017
  • Purpose - To improve and strengthen existing publication and research ethics, KODISA has identified and presented various cases which have violated publication and research ethics and principles in recent years. The editorial office of KODISA has been providing and continues to provide advice and feedback on publication ethics to researchers during peer review and editorial decision making process. Providing advice and feedback on publication ethics will ensure researchers to have an opportunity to correct their mistakes or make appropriate decisions and avoid any violations in research ethics. The purpose of this paper is to identify different cases of ethical violation in research and inform and educate researchers to avoid any violations in publication and research ethics. Furthermore, this article will demonstrate how KODISA journals identify and penalize ethical violations and strengthens its publication ethics and practices. Research design, data and methodology - This paper examines different types of ethical violation in publication and research ethics. The paper identifies and analyzes all ethical violations in research and combines them into five general categories. Those five general types of ethical violations are thoroughly examined and discussed. Results - Ethical violations of research occur in various forms at regular intervals; in other words, unethical researchers tend to commit different types of ethical violations repeatedly at same time. The five categories of ethical violation in research are as follows: (1) Arbitrary changes or additions in author(s) happen frequently in thesis/dissertation related publications. (2) Self plagiarism, submitting same work or mixture of previous works with or without using proper citations, also occurs frequently, but the most common type of plagiarism is changing the statistical results and using them to present as the results of the empirical analysis; (3) Translation plagiarism, another ethical violation in publication, is difficult to detect but occurs frequently; (4) Fabrication of data or statistical analysis also occurs frequently. KODISA requires authors to submit the results of the empirical analysis of the paper (the output of the statistical program) to prevent this type of ethical violation; (5) Mashup or aggregator plagiarism, submitting a mix of several different works with or without proper citations without alterations, is very difficult to detect, and KODISA journals consider this type of plagiarism as the worst ethical violation. Conclusions - There are some individual cases of ethical violation in research and publication that could not be included in the five categories presented throughout the paper. KODISA and its editorial office should continue to develop, revise, and strengthen their publication ethics, to learn and share different ways to detect any ethical violations in research and publication, to train and educate its editorial members and researchers, and to analyze and share different cases of ethical violations with the scholarly community.

The treatment of an edentulous patient with DENTCA$^{TM}$ CAD/CAM Denture (CAD/CAM Denture를 이용한 완전 무치악 환자 수복 증례)

  • Park, Joon-Ho;Cho, In-Ho;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease chair time and the number of visits, thus decreasing total fabrication time, expenses and errors caused during fabrication processes. One of the systems using CAD/CAM, DENTCA$^{TM}$ CAD/CAM denture (DENTCA Inc. Los Angeles, USA) scans edentulous impressions, designs dentures digitally, fabricates try-in dentures by 3D printing and converts them into final dentures. Patients can wear final dentures after only 2 - 3 visits with satisfying adaptation. This case report introduces a 71-year-old male patient who visited to consult remaking of existing old dentures. Residual teeth with bad prognosis and root remnants were extracted and the patient used reformed existing mandibular denture for 2 months. And then DENTCA system started. One-step border molding was done using conventional tray of adequate size provided by DENTCA system and wash impression was taken. Gothic arch tracing was completed based on the vertical dimension of existing dentures. Both maxillary and mandibular trays were placed to the resultant centric relation and bite registration was taken. Then DENTCA scanned the bite registration, arranged the teeth, completed the festooning and fabricated the try-in dentures by 3D printing. The try-in dentures were positioned, occlusal plane and occlusal relations were evaluated. The try-in dentures were converted to final dentures. To create bilateral balanced occlusion, occlusal adjustment was done after clinical remounting using facebow transfer. The result was satisfactory and it was confirmed by patient and operator.

Electrooptic Modulator with InAs Quantum Dots (InAs/InGaAs 양자점을 이용한 전계광학변조기)

  • Ok, Seong-Hae;Moon, Yon-Tae;Choi, Young-Wan;Son, Chang-Wan;Lee, Seok;Woo, Deok-Ha;Byun, Young-Tae;Jhon, Young-Min;Kim, Sun-Ho;Yi, Jong-Chang;Oh, Jae-Eung
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.278-284
    • /
    • 2006
  • We have fabricated and measured electrooptic modulator using coupled stack InAs/InGaAs quantum dots. The height of the quantum dot is 16 nm and quantum dots are stacked including an InGaAs capping layer. The peak wavelength of photoluminescence is 1260 nm at room temperature and 1158 nm at 12 K. The operation characteristics of the quantum dots show high modulation efficiency of electrooptic modulator at 1550 nm compared to that of existing III-V bulk and MQW type semiconductor. The measured switching voltage ($V\pi$) is 540 and 600 mV, for TE mode and TM mode, respectively. From the results, the modulation efficiency can be determined as 333.3 and $300^{\circ}/V{\cdot}mm$ for TE and TM modes. The results reported here may lead to the design and fabrication of a novel electrooptic modulator with low switching voltage and high efficiency.

Design and Fabrication of K Band Push-Push Dielectric Resonator Oscillator (K 대역 Push-Push 유전체 공진기 발진기 설계 및 제작)

  • 정재권;박승욱;김인석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.7
    • /
    • pp.613-624
    • /
    • 2002
  • Electrical characteristics of two types of 20 GHz Push-Push GaAs MESFET dielectric resonator oscillators having Wilkinson and T-junction power combiners for the output stage have been investigated and compared. So we have explained that the output power and phase noise properties of the Push-push FET DRO are depending on return loss and isolation characteristics of power combiner at the fundamental and the second harmonic frequencies. A Push-push oscillator for suppressing the fundamental frequency of 10 GHz and enhancing the second harmonic of 20 GHz has been designed and fabricated in microstrip configuration on 20 mil thick RT-Duroid($\varepsilon$$_{r}$ = 2.52) Teflon substrate. Return loss and isolation characteristics of T-junction and Wilkinson have been measured at the fundamental frequency of 10.2 GHz and the second harmonic frequency of 20.5 GHz. At the fundamental frequency, -12 dB return loss and -3.7 dB isolation have been measured for the T-junction power combiner, and -14 dB return loss and -11 dB isolation fur the Wilkinson power combiner. At the second harmonic frequency, -10 dB return loss and -7.5 dB isolation have been obtained for the T-junction power combiner, and -23 dB return loss and -22 dB isolation for the Wilkinson power combiner. As a result, we have confirmed that the oscillator based on the Wilkinson power combiner with better retrun loss and isolation characteristics produces more output power and better phase noise characteristics..

Fabrication Technique and Structural Performance Verification of PSC U-Type Segment Girder Using On-Site Pretension Method (현장 프리텐션 긴장 방식 적용 PSC U형 분절 거더 제작 기술 및 구조 성능 검증)

  • Sangki Park;Jaehwan Kim;Dong-Woo Seo;Ki-Tae Park;Hyun-Ock Jang
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.3
    • /
    • pp.17-26
    • /
    • 2023
  • Prestressed Concrete (PSC) girders are divided into pre- and post-tension types as prestressing method, and I- and U-type as cross-sectional shape. There are both advantages and disadvantages depending on each prestressing method and cross-sectional shape, and each method is applied to bridge construction sites. In this study, a new girder design was attempted to develop that overcomes its shortcomings by using the pretension method and U-type cross sectional shape. Its structural performance was verified in this study. Pretension type girders are mainly manufactured in factories because they require a reaction arm and related facilities, and have the disadvantage of being limited in weight and span length for road transportation. In addition, in the case of the U-type cross-section, structural stability is very reliable during construction against overturning, but its own weight is relatively large comparing to I-type, and the post-tension method is mainly applied after on-site production. In this study, a PSC girder manufacturing method using the field pretension was proposed and a span length of 40 m real-scale test specimen was manufactured and verified its structural performance.

VLSI Design of DWT-based Image Processor for Real-Time Image Compression and Reconstruction System (실시간 영상압축과 복원시스템을 위한 DWT기반의 영상처리 프로세서의 VLSI 설계)

  • Seo, Young-Ho;Kim, Dong-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.1C
    • /
    • pp.102-110
    • /
    • 2004
  • In this paper, we propose a VLSI structure of real-time image compression and reconstruction processor using 2-D discrete wavelet transform and implement into a hardware which use minimal hardware resource using ASIC library. In the implemented hardware, Data path part consists of the DWT kernel for the wavelet transform and inverse transform, quantizer/dequantizer, the huffman encoder/huffman decoder, the adder/buffer for the inverse wavelet transform, and the interface modules for input/output. Control part consists of the programming register, the controller which decodes the instructions and generates the control signals, and the status register for indicating the internal state into the external of circuit. According to the programming condition, the designed circuit has the various selective output formats which are wavelet coefficient, quantization coefficient or index, and Huffman code in image compression mode, and Huffman decoding result, reconstructed quantization coefficient, and reconstructed wavelet coefficient in image reconstructed mode. The programming register has 16 stages and one instruction can be used for a horizontal(or vertical) filtering in a level. Since each register automatically operated in the right order, 4-level discrete wavelet transform can be executed by a programming. We synthesized the designed circuit with synthesis library of Hynix 0.35um CMOS fabrication using the synthesis tool, Synopsys and extracted the gate-level netlist. From the netlist, timing information was extracted using Vela tool. We executed the timing simulation with the extracted netlist and timing information using NC-Verilog tool. Also PNR and layout process was executed using Apollo tool. The Implemented hardware has about 50,000 gate sizes and stably operates in 80MHz clock frequency.

THE FIT OF ZIRCONIA FORE FABRICATED WITH CAD/CAM SYSTEM (CAD/CAM system으로 제작한 zirconia core의 적합도)

  • Seong Ji-Yun;Jeon Young-Chan;Jeong Chang-Mo;Lim Jang-Seop
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.5
    • /
    • pp.489-500
    • /
    • 2004
  • Statement of problem: The use of zirconia prostheses fabricated with CAD/CAM system is on an increasing trend in dentistry. However, evaluation of the fit related to internal relief and marginal reproducibility of zirconia has not been reported. Purpose : This study was to evaluate the fit related to internal relief and marginal reproducibility of zirconia core fabricated with CAD/CAM system. Materials and methods: The evaluation was based on 30 zirconia cores and 5 IPS-Empress2 cores. Zirconia cores were fabricated in different conditions of internal relief(0, 10, 20, 30, 40 and $50{\mu}m$), and IPS-Empress2 cores were fabricated in accordance with the manufacturer's instructions. Before cementation, the marginal discrepancies or cores were measured on metal die. And then, each core was cemented to stone die, embedded in an acrylic resin and sectioned in two planes(mesiodistally and labiopalatally). The internal gaps were measured at the margin and axial surface. Measurements for the marginal discrepancies, the internal marginal gaps and the internal axial gaps were performed under a measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of ${\times}100$. In addition, the marginal conagurations of metal die, zirconia core and IPS-Empress2 core were examined with SEM(S-2700, Hitachi, Japan). Results : Within the limits of this study the results were as follows. 1. Compared with IPS-Empress2 cores, the marginal discrepancies of zirconia cores had no significant differences. the internal marginal gaps were statistically smaller and the internal axial gaps were statistically larger in each condition of internal relief. 2. The marginal discrepancies and the internal marginal gaps of zirconia cores had no significant differences related to the conditions of internal relief(P>0.05). 3. The internal axial gaps of zirconia cores with $0{\sim}20{\mu}$m for internal relief were significantly larger than that with $50{\mu}m$ (P<(0.0001). 4. SEM micrographs showed favorable marginal reproducibility of zirconia core and smooth texture on the milling surface. Conclusion: The marginal discrepancy and the internal gaps of zirconia core were clinically acceptable and the milling surface was showed smooth texture. For fabrication of the durable esthetic restoration, further investigations on complex design of core, milling accuracy, compatability of enamel porcelain and porcelain firing seems to be needed.

Evaluation of the Usefulness of Patient Customized Shielding Block Made with 3D Printer in the Skin Cancer Electron Beam Therapy (전자선치료 시 3D 프린터로 제작한 환자 맞춤형 차폐체의 유용성 평가)

  • Ahn, Ki-Song;Jung, Woo-Chan;Kim, Dae-Hyun;Kim, Moo-Sub;Yoon, Do-Kun;Shim, Jae-Goo;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.447-454
    • /
    • 2019
  • In order to improve and supplement the shielding method for electron beam treatment, we designed a patient-specific shielding method using a 3D printer, and evaluated the usefulness by comparing and analyzing the distribution of electron beam doses to adjacent organs. In order to treat 5 cm sized superficial tumors around the lens, a CT Simulator was used to scan the Alderson Rando phantom and the DICOM file was converted into an STL file. The converted STL file was used to design a patient-specific shield and mold that matched the body surface contour of the treatment site. The thickness of the shield was 1 cm and 1.5 cm, and the mold was printed using a 3D printer, and the patient customized shielding block (PCSB) was fabricated with a cerrobend alloy with a thickness of 1 cm and 1.5 cm. The dosimetry was performed by attaching an EBT3 film on the surface of the Alderson Rando phantom eyelid and measuring the dose of 6, 9, and 12 MeV electron beams on the film using four shielding methods. Shielding rates were 83.89%, 87.14%, 87.39% at 6, 9, and 12 MeV without shielding, 1 cm (92.04%, 87.48%, 86.49%), 1.5 cm (91.13%, 91.88% with PSCB), 92.66%) The shielding rate was measured as 1 cm (90.7%, 92.23%, 88.08%) and 1.5 cm (88.31%, 90.66%, 91.81%) when the shielding block and the patient-specific shield were used together. PCSB fabrication improves shielding efficiency over conventional shielding methods. Therefore, PSCB may be useful for clinical application.

Comparison of marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures fabricated from solid working casts and working casts from a removable die system (가철성 다이 시스템으로 제작된 작업 모형과 솔리드 작업 모형 상에서 제작된 지르코니아 3본 고정성 치과 보철물의 변연 및 내면 적합도 비교)

  • Wan-Sun Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.72-81
    • /
    • 2024
  • Purpose: This study aimed to assess the marginal and internal fit of 3-unit monolithic zirconia fixed partial dentures (FPDs) fabricated via computer-aided design and computer-aided manufacturing (CAD/CAM) from solid working casts and removable die system. Materials and Methods: The tooth preparation protocol for a zirconia crown was executed on the mandibular right first premolar and mandibular right first molar, with the creation of a reference cast featuring an absent mandibular right second premolar. The reference cast was duplicated using polyvinyl siloxane impression, from which 20 working casts were fabricated following typical dental laboratory procedures. For comparative analysis, 10 FPDs were produced from a removable die system (RD group) and the remaining 10 FPDs from the solid working casts (S group). The casts were digitized using a dental desktop scanner to establish virtual casts and design the FPDs using CAD. The definitive 3-unit monolithic zirconia FPDs were fabricated via a CAM milling process. The seated FPDs on the reference cast underwent digital evaluation for marginal and internal fit. The Mann-Whitney U test was applied for statistical comparison between the two groups (α = 0.05). Results: The RD group showed significantly higher discrepancies in fit for both premolars and molars compared to the S group (P < 0.05), particularly in terms of marginal and occlusal gaps. Color mapping also highlighted more significant deviations in the RD group, especially in the marginal and occlusal regions. Conclusion: The study found that the discrepancies in marginal and occlusal fits of 3-unit monolithic zirconia FPDs were primarily associated with those fabricated using the removable die system. This indicates the significant impact of the fabrication method on the accuracy of FPDs.