• Title/Summary/Keyword: Design Window

Search Result 980, Processing Time 0.027 seconds

A Study on the Actual Conditions and Responses of New Han-ok Inhabitants through Questionnaire - Focused in Jeonnam Province - (신한옥 주거 만족도 실태조사 연구 - 전라남도를 중심으로 -)

  • Song, Min-Jeong;Jang, Hyeon-Chung;Lee, Tai-Gang;Lee, Ju-Yeob;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.3-12
    • /
    • 2013
  • Recently, New Han-ok is in prevail because it has many good qualities as a dwelling. But the New Han-ok dwellers' needs and satisfaction ratio on their houses are not investigated yet. So, surveys on satisfaction ratio for New Han-ok were carried out to know New Han-ok's existing conditions and inhabitant's responses on New Han-ok dwellings. Followings are results. 1) Dwellers response that it is cool in summer and it is cold in winter. So, design and construction method against cold is needed for New Han-ok. 2) Window is the most picking element of New Han-ok for house improvement. 3) Window opening is main control method for cooling in summer. Warming sources in winter are various such as electricity, gas, oil, wood, etc. 4) PVC window structure and glasses were used for New Han-ok's window system as well as wooden window structure and Han-gi. 5) Interviewees are generally satisfied with New Han-ok's exterior view and inner spaces. Almost no humidifier is used. These results could be used for improvement of Han-ok and basic material for New Han-ok design.

Comparative Analysis on the Heating and Cooling Loads Associated with U-value, SHGC and Orientation of the Windows in Different Regions (창호의 열관류율, 일사취득계수와 향의 배치가 건물의 냉난방 부하에 미치는 영향에 관한 지역별 비교연구)

  • Choi, Min-Seo;Chang, Seong-Ju
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.123-130
    • /
    • 2013
  • The primary goal of this research is to identify the impacts of window design on the energy use in buildings which takes up about 25% of the total energy consumption. Recently, efficient use of energy is gaining more importance in buildings. Window design, especially being dependent on glazing performance choices, is an important factor for reducing energy consumption in most of the buildings. It also is influenced by the latitude of the site and window orientation. This paper aims at identifying the influence of Window performance indicators(U-value, SHGC), orientation and latitude on the building energy consumption with systematically designed simulations. Comparative study has been performed for five different locations; Greenland, Korea, Singapore, Argentina and Chile along with the different window U-value and SHGC values. The results show that optimum window system with properly coordinated window performance indicators(U-value, SHGC), orientation achieves dramatic reduction of energy consumptions. Windows with low U-value could reduce heating loads and high SHGC could reduce cooling loads. The study also verifies that the windows installed at south facade is more energy efficient in the northern hemisphere while windows facing north is more energy efficient in the southern hemisphere.

The Effects of VM Components on Store Image and Purchasing Intention of Fashion Stores - Focused on Facade Color and Show Window Type - (의류매장의 VM 구성요소가 점포이미지와 구매의도에 미치는 영향 - 파사드 색상과 쇼 윈도우 유형을 중심으로 -)

  • Lee, Mi-Sook
    • The Research Journal of the Costume Culture
    • /
    • v.20 no.3
    • /
    • pp.416-429
    • /
    • 2012
  • The purpose of this study was to examine the effects of VM components(facade color and show window type) on store image and purchasing intention of fashion stores. The subjects were 428 male and female university students in Daejeon and Chungnam province. The measuring instruments were 6 stimuli manipulated by $3{\times}2$ factorial design of facade color and show window type, and a self-administrated questionnaire consisted of store image, purchasing intention, and subjects' demographic characteristics. The results were as follows. First, facade color mainly affected store image and purchasing intention. White color was preferred as more positive images(pleasurable, comfortable, neat, and modern), and showed higher purchasing intention than brown color. Second, show window type affected some store images. Semi-open type was perceived as more pleasurable image than enclosed type, whereas enclosed type was perceived as more luxurious, neat, and attractive image than semi-open type. However, show window type didn't affect purchasing intention. Third, subject' sex affected store image and purchasing intention. Male subjects perceived more positively on store image and had higher purchasing intention than females. This study suggested that facade color and show window type are important VM components affecting store image and purchasing intention.

Production of Window Motor Assembly Parts in Automotive Body (자동차 전장에서 윈도우 모터 조립 부품의 생산)

  • Lee, Jeong-Ick
    • Journal of the Korea Convergence Society
    • /
    • v.3 no.4
    • /
    • pp.29-34
    • /
    • 2012
  • Power window motor assembly including ECU system is important to doors of automobile. This study is done for own development instead of importing of power window motor assembly. This paper is written under five specific subjects. The first, making of prototype sample and analysis of mass-production problem using CAE, the second, design of mass-production mold(2D and 3D), the third, manufacturing of sample mold, the fourth, tryout and measuring of 3 dimensions, the fifth, data analysis and mold modify. In the among them, product sample and analysis of mass-production using CAE, design and manufacture of mass-production mold, and production of sample mold are successfully done. In the results, it is made clear that two cavity and one gate are proper to make a mold of power window motor assembly housing. Besides, it is acquired own technology for mass-production of power window motor.

Balcony window style photo-voltaic(PV) system design by considering resident's residential time rate - Focus on the design of apartment building balcony window PV system and it's performance - (거주자 주택 점유율을 고려한 공동주택 발코니 PV시스템 디자인 - 공동주택의 발코니 PV시스템 디자인과 성능검증 중심으로 -)

  • Chin, Kyung-Il
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.5
    • /
    • pp.101-110
    • /
    • 2009
  • In case of general residential house, photovoltaic can be installed at roof, wall, and any other places. But, in case of apartment building, there has not enough roof space to install photovoltaic panels to supply enough electricity. Actually, apartment building roof and facade wall (exclude the balcony window space) is not enough space to produce and supply the electricity to residents by installing PV panel. Generally, the space of facade balcony with windows in facade wall at apartment building occupied about $70{\sim}80%$, in all facade space. So, if we could use the balcony and windows space in facade as PV to generating electricity, there could contribute the energy saying. But, PV cell is opacify. So if it installed at front window area in apartment building, residents may have displeasure for that opacity character. But the other hand, residents are not always in house especially in day time that is exactly good time for generating electricity by PV. If we can use PV at the facade balcony with window without collusion of resident's displeasure, there have good attraction to using sustainable energy. Hence, this study suggests the design of facade balcony window style PV by considering resident's living pattern in apartment building. The methods of this study are as follows. At first, this study surveyed to the residents about residential time in their home and asked user demand by Delphi survey. At second, this study designed balcony open style PV system which oriented to the user demand. At third, this study tests designed result performance by computer simulation that compared design result with old design. As a result, For the purpose of satisfying the resident demand, there designed sliding window style which slide the several door systems to the one side. That would be make balcony absolute open scenery to the residents. Hence, the designed system performance results were as follows. When we compare the small apartment and large apartment, smaller one has good performance than larger one. Because resident's residential time characteristic. And that has more good electronic performance than vertical style that is similar to roof style.

Optimization of an Electron Microwave Oven Window Injection Mold Using Kriging Based Approximation Model (크리깅을 이용한 전자 오븐 윈도우 부품용 사출금형의 최적설계)

  • Ryu M. R.;Lee K. H.;Kim Y. H.;Park H. S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.7 s.172
    • /
    • pp.177-184
    • /
    • 2005
  • Recently, the engineering designer of injection mould has become more and more dependent on the CAE. In the design factors of injection mould, the shrinkage rate should be considered as one of the important performances to produce the reliable products. therefore the shrinkage rate can be mostly calculated by the MoldFlow and Pro-engineering. in the design process. However it is not easy to predict the shrinkage rate of a plastic injection mold in its design process because the analysis can take minutes to hours, the high computational costs of performing the analysis limit their use in design optimization. In this study, the surrogate models, DACE model, based on the Kriging in order to optimize the shrinkage rate of electric microwave oven window is used in lieu of the original models, facilitating design optimization.

Design of Automotive Anti-trap Power Window Lift Controller (자동차 Anti-trap Power Window Lift Controller 설계)

  • Cha, Min-Hyeok;Kim, Hak-Lyun;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.51-53
    • /
    • 2001
  • Permanent Magnet DC Motors are widely used in Automotive parts because they have cheap price, simple structure and high torque-speed ratio. But the motor in automotive parts is required high quality, complex function and lower price than before. This paper deals with design of controller for safety function that body trap on the automotive window. The algorithm of controller can adapt variety conditions with temperature, electrical, driving, etc.

  • PDF

Strength Analysis of Aluminum Alloy Window Wiper Manufactured by Die Casting (다이캐스팅용 알루미늄 합금으로 제작된 윈도우 와이퍼의 강도 해석)

  • Cho, Seunghyun;Lee, Jeungho;Kim, Hangoo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.3
    • /
    • pp.204-210
    • /
    • 2016
  • This study analyzed the amount of displacement of window wipers according to pressure by using finite element analysis (FEA) with KS standards for aluminum alloy window wipers manufactured by die-casting method. The product design was changed over four steps considering the die-casting process to achieve strength greater than that of the conventional steel window wiper. According to the FEA results, the strength of final aluminum alloy window wiper improved by 55% over that of a steel window wiper, and the weight of the former was less by approximately 45%. Therefore, there is the possibility of module downsizing for driving motor capacity. Further, the cost competitiveness improved, and the manufacturing process of aluminum alloy window wipers was simplified.

A Study on FIR Digital filter using Window Function (Window 함수를 이용한 FIR 디지털필터에 관한 연구)

  • 구본석;배상범;김남호
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.68-74
    • /
    • 2004
  • The use of digital filters in the signal processing field is increasing rapidly with development of the modem industrial society, and generally digital filter is classified into FIR (infinite impulse response) fillers and FIR (finite impulse response) filters. The FIR digital filter has the phase linearity and the easiness of creation. In the design of the FIR digital filter, the window function is used to alleviate ripples caused by Gibbs Phenomenon around the cut-off frequency of the passband. In this paper, we designed a new window function and compared with existing Manning, Hamming and Blackman window functions. And we used peak side-lobe and transient characteristics as standard of judgement.

  • PDF

Thermal Performance Evaluation of Junction Thermal Bridge according to Installation Position of Window

  • Lee, Soo-Man;Kim, Dong-Yun;Ahn, Jung-Hyuk;Eom, Jae-Yong;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: "Building energy design standard" is used to limit the thermal transmittance of building in Korea. However, it only covers the insulation standard for each appropriate elements of a building, not the thermal performance of Junction thermal bridge of windows and doors installed in wall. Therefore in this study, we have evaluated the thermal performance of Junction thermal bridge depending on installation method and position of windows and provide it as design data. Method: We analyzed heat transfer of 4-Track sliding window and tilt & turn triple glazed window that are placed in the first class category on window energy efficiency rating using Window 7.4 and Therm 7.4. Result : First, linear thermal transmittance of 4-Track sliding window differs by 2.2 times or more depending of installation method and location. It is higher than the linear thermal transmittance, 0.01W/mK, proposed by Passivhaus. Second, linear thermal transmittance of Tilt & turn triple glazed window differs by 7.7 times or more depending of installation method and location. The average linear thermal transmittance was less than 0.01W /mK when windows were installed on the internal wall insulation by the fixed hardware attachment method. Third, the thermal losses of a window caused by a junction thermal bridge are inversely proportional to the window area and converge gradually as the area increased.