• 제목/요약/키워드: Design Ultimate Load

검색결과 510건 처리시간 0.027초

Flexural strengthening of continuous unbonded post-tensioned concrete beams with end-anchored CFRP laminates

  • Ghasemi, Saeed;Maghsoudi, Ali A.;Bengar, Habib A.;Ronagh, Hamid R.
    • Structural Engineering and Mechanics
    • /
    • 제53권6호
    • /
    • pp.1083-1104
    • /
    • 2015
  • This paper provides the results of an experimental investigation into the flexural behavior of continuous two-span unbonded post-tensioned high strength concrete (HSC) beams, strengthened by end-anchored CFRP laminates of different configurations in the hogging region. Implementing two different configurations of end-anchorage systems consisting of steel plates and bolts and carefully monitoring the development of strains throughout the load history using sufficiently large number of strain gauges, the response of beams including the observed crack propagations, beam deflection, modes of failure, capacity enhancement at service and ultimate and the amount of moment redistribution are measured, presented and discussed. The study is appropriate in the sense that it covers the more commonly occurring two span beams instead of the simply supported beams investigated by others. The experiments reconfirmed the finding of others that proper installation of composite strengthening system is most important in the quality of the bond which is essential for the internal transfer of forces. It was also found that for the tested two span continuous beams, the capacity enhancement is more pronounced at the serviceability level than the ultimate. This is an important finding as the design of these beams is mostly governed by the serviceability limit state signifying the appropriateness of the suggested strengthening method. The paper provides quantitative data on the amount of this capacity enhancement.

충돌에 의한 소성변형을 갖는 보강판의 잉여강도 해석 (Redundancy Analysis of Stiffened Panel with Plastic Deformation due to Collision)

  • 염철웅;노인식
    • 대한조선학회논문집
    • /
    • 제52권2호
    • /
    • pp.161-169
    • /
    • 2015
  • According to SOLAS Regulation XII/6.5.3 and IMO GBS functional requirement(IMO, 2010), the structural redundancy of multi-bay stiffened panel in cargo area of bulk carrier should be provided enough in order to endure the initial design load though one bay of the stiffened panel is damaged due to plastic deformation or fatigue crack. To satisfy structural redundancy, Harmonized Common Structural Rules (hereinafter CSR-H, IACS, 2014) proposed to use 1.15 instead of 1.0 for buckling usage factor of stiffened panel in cargo area. This paper shows that buckling usage factor in CSR-H for structural redundancy is somewhat conservative considering the ultimate strength calculated by using nonlinear FEA for the damaged condition which is only one bay's plastic deformation due to colliding by weigh object like a bucket. Also, this paper presents that increasing of plate thickness only is more effective to get enough structural redundancy.

Behavior of steel-concrete jacketed corrosion-damaged RC columns subjected to eccentric load

  • Hu, Jiyue;Liang, Hongjun;Lu, Yiyan
    • Steel and Composite Structures
    • /
    • 제29권6호
    • /
    • pp.689-701
    • /
    • 2018
  • Corrosion of steel reinforcement is a principal cause of deterioration of RC columns. Making these corrosion-damaged columns conform to new safety regulations and functions is a tremendous technological challenge. This study presented an experimental investigation on steel-concrete jacketed corrosion-damaged RC columns. The influences of steel jacket thickness and concrete strength on the enhancement performance of the strengthened specimens were investigated. The results showed that the use of steel-concrete jacketing is efficient since the stub strengthened columns behaved in a more ductile manner. Moreover, the ultimate strength of the corrosion-damaged RC columns is increased by an average of 5.3 times, and the ductility is also significantly improved by the strengthening method. The bearing capacity of the strengthening columns increases with the steel tube thickness increasing, and the strengthening concrete strength has a positive impact on both bearing capacity, whereas a negative influence on the ductility. Subsequently, a numerical model was developed to predict the behavior of the retrofitted columns. The model takes into account corrosion-damage of steel rebar and confining enhancement supplied by the steel tube. Comparative results with the experimental results indicated that the developed numerical model is an effective simulation. Based on extensive verified numerical studies, a design equation was proposed and found to predict well the ultimate eccentric strength of the strengthened columns.

LRFD 설계법에 의한 부마찰력이 작용하는 말뚝의 안정성 평가 (Stability Evaluation of Piles under Negative Skin Friction by the LRFD Approach)

  • 조천환;김웅규;이우철;강인철;김영식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.17-24
    • /
    • 2005
  • Recently construction activities increase in reclaimed onshore areas. It is therefore considered an important factor for the design of pile foundation with problems in terms of settlements due to soft grounds. Nevertheless the design of piles for negative skin friction(or downdrag forces) is probably poorly understood by many engineers. It is mainly because the most of design specification give a way to design pile foundation in bearing capacity aspect although the negative skin friction is related to settlement(downdrag). Under LRFD(load resistance factor design) approach it is to separately consider ultimate limit state and serviceability limit state. This paper discusses LRFD approach to the design of piles for negative skin friction and compares this approach to traditional design approach. And also a case history is analyzed in that point of view.

  • PDF

Direct displacement based design of hybrid passive resistive truss girder frames

  • Shaghaghian, Amir Hamzeh;Dehkordi, Morteza Raissi;Eghbali, Mahdi
    • Steel and Composite Structures
    • /
    • 제28권6호
    • /
    • pp.691-708
    • /
    • 2018
  • An innovative Hybrid Passive Resistive configuration for Truss Girder Frames (HPR-TGFs) is introduced in the present study. The proposed system is principally consisting of Fluid Viscous Dampers (FVDs) and Buckling Restrained Braces (BRBs) as its seismic resistive components. Concurrent utilization of these devices will develop an efficient energy dissipating mechanism which is able to mitigate lateral displacements as well as the base shear, simultaneously. However, under certain circumstances which the presence of FVDs might not be essential, the proposed configuration has the potential to incorporate double BRBs in order to achieve the redundancy of alternative load bearing paths. This study is extending the modern Direct Displacement Based Design (DDBD) procedure as the design methodology for HPR-TGF systems. Based on a series of nonlinear time history analysis, it is demonstrated that the design outcomes are almost identical to the pre-assumed design criteria. This implies that the ultimate characteristics of HPR-TGFs such as lateral stiffness and inter-story drifts are well-proportioned through the proposed design procedure.

Seismic design of irregular space steel frames using advanced methods of analysis

  • Vasilopoulos, A.A.;Bazeos, N.;Beskos, D.E.
    • Steel and Composite Structures
    • /
    • 제8권1호
    • /
    • pp.53-83
    • /
    • 2008
  • A rational and efficient seismic design methodology for irregular space steel frames using advanced methods of analysis in the framework of Eurocodes 8 and 3 is presented. This design methodology employs an advanced static or dynamic finite element method of analysis that takes into account geometrical and material non-linearities and member and frame imperfections. The inelastic static analysis (pushover) is employed with multimodal load along the height of the building combining the first few modes. The inelastic dynamic method in the time domain is employed with accelerograms taken from real earthquakes scaled so as to be compatible with the elastic design spectrum of Eurocode 8. The design procedure starts with assumed member sections, continues with the checking of the damage and ultimate limit states requirements, the serviceability requirements and ends with the adjustment of member sizes. Thus it can sufficiently capture the limit states of displacements, rotations, strength, stability and damage of the structure and its individual members so that separate member capacity checks through the interaction equations of Eurocode 3 or the usage of the conservative and crude q-factor suggested in Eurocode 8 are not required. Two numerical examples dealing with the seismic design of irregular space steel moment resisting frames are presented to illustrate the proposed method and demonstrate its advantages. The first considers a seven storey geometrically regular frame with in-plan eccentricities, while the second a six storey frame with a setback.

Behaviour and design of Grade 10.9 high-strength bolts under combined actions

  • Li, Dongxu;Uy, Brian;Wang, Jia;Song, Yuchen
    • Steel and Composite Structures
    • /
    • 제35권3호
    • /
    • pp.327-341
    • /
    • 2020
  • The use of high-strength steel and concrete in the construction industry has been gaining increasing attention over the past few decades. With it comes the need to utilise high-strength structural bolts to ensure the design load to be transferred safely through joint regions, where the space is limited due to the reduced structural dimensions. However, research on the behaviour of high-strength structural bolts under various loading combinations is still insufficient. Most of the current design specifications concerning high-strength structural bolts were established based on a very limited set of experimental results. Moreover, as experimental programs normally include limited design parameters for investigation, finite element analysis has become one of the effective methods to assist the understanding of the behaviour of structural components. An accurate and simple full-range stress-strain model for high-strength structural bolts under different loading combinations was therefore developed, where the effects of bolt fracture was included. The ultimate strength capacities of various structural bolts obtained from the present experimental program were compared with the existing design provisions. Furthermore, design recommendations concerning the pure shear and tension, as well as combined shear and tension resistance of Grade 10.9 high-strength structural bolts were provided.

대심도 연약지반에 근입된 PHC말뚝기초의 하중전이특성 및 극한지지력 산정 (Load Transfer Characteristics and Ultimate Bearing Capacity of PHC Pile in Deep Soft Clay Layer)

  • 이용화;김명학
    • 한국지반환경공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.41-46
    • /
    • 2008
  • 본 연구에서는 대심도 연약지반에서 PHC말뚝을 항타관입한 후 일정기간 이후 정재하시험을 통한 하중전이분석을 실시하였다. 하중전이분석에서 단위주면마찰력은 상부의 사질토에서 $7.4t/m^2$, 심도 14m에서 33m의 점성토구간에서는 $6.4t/m^2$, 말뚝선단부가 근입된 사질토에서는 $23.3t/m^2$이 발휘되었으며, 단위선단지지력은 $955t/m^2$으로 실측되었다. 전이된 단위주면마찰력과 국내외에서 알려져 있는 정역학적 지지력산정식과의 비교를 해본 결과 토층별로 가장 적합한 공식을 선정한다면, 사질토의 단위주면마찰력의 경우 한국지반공학회의 구조물기초설계기준 및 해설이, 점성토의 단위주면마찰력의 경우 철도청의 철도설계기준이 가장 실측치에 근접한 값을 나타내었다.

  • PDF

2,400 MPa 강연선용 포스트텐션 정착구의 하중전달성능 (The Load Transfer Performance of Post-tension Anchorage with 2,400 MPa Strands)

  • 김선우;노병철;임정훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.63-71
    • /
    • 2018
  • 인장강도가 2,400 MPa인 강연선이 개발되어 콘크리트구조기준 및 KS 규격에 반영되었다. 고강도 프리스트레스트 강연선이 구조물에 적용되기 위해서는 그에 적합한 정착시스템이 함께 사용되어야 한다. 최근에 2,400 MPa 강연선 적용을 위한 포스트텐션 정착구의 개발이 진행되어왔으나, 성능평가에 대한 연구가 미비한 실정이다. 따라서 본 연구에서는 2,400 MPa 강연선을 적용한 포스트텐션 정착구 중 가장 활용도가 높은 9 가닥, 15 가닥, 19 가닥 정착구에 대하여 PTI의 Anchorage Design Zone에 의한 국소구역 구조검토를 실시하였고, ETAG013 및 KCI-PS101에 의한 하중전달성능평가를 수행하였다. 또한 비선형 수치해석을 통해 시험의 적절성을 분석하였다. 그 결과, 2,400 MPa 정착구는 국소구역의 구조성능을 만족하고, 하중전달성능 조건을 만족하는 것으로 나타났다.

AFP mandrel development for composite aircraft fuselage skin

  • Kumar, Deepak;Ko, Myung-Gyun;Roy, Rene;Kweon, Jin-Hwe;Choi, Jin-Ho;Jeong, Soon-Kwan;Jeon, Jin-Woo;Han, Jun-Su
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제15권1호
    • /
    • pp.32-43
    • /
    • 2014
  • Automatic fiber placement (AFP) has become a popular processing technique for composites in the aerospace industry, due to its ability to place prepregs or tapes precisely in the exact position when complex parts are being manufactured. This paper presents the design, analysis, and manufacture of an AFP mandrel for composite aircraft fuselage skin fabrication. According to the design requirements, an AFP mandrel was developed and a numerical study was performed through the finite element method. Linear static load analyses were performed considering the mandrel structure self-weight and a 2940 N load from the AFP machine head. Modal analysis was also performed to determine the mandrel's natural frequencies. These analyses confirmed that the proposed mandrel meets the design requirements. A prototype mandrel was then manufactured and used to fabricate a composite fuselage skin. Material load tests were conducted on the AFP fuselage skin curved laminates, equivalent flat AFP, and hand layup laminates. The flat AFP and hand layup laminates showed almost identical strength results in tension and compression. Compared to hand layup, the flat AFP laminate modulus was 5.2% higher in tension and 12.6% lower in compression. The AFP curved laminates had an ultimate compressive strength of 1.6% to 8.7% higher than flat laminates. The FEM simulation predicted strengths were 4% higher in tension and 11% higher in compression than the flat laminate test results.