• Title/Summary/Keyword: Design Test Evaluation

Search Result 2,817, Processing Time 0.03 seconds

Design of Degradation Test without Replacement Based on Tightened Critical Value (엄격한 고장판정기준을 적용한 비복원 열화시험 설계에 관한 연구)

  • Park Boo Hee;Lim Ho Kyung;Jang Joong Soon
    • Journal of Applied Reliability
    • /
    • v.5 no.1
    • /
    • pp.167-180
    • /
    • 2005
  • Design of a degradation test without replacement is considered based on tightened critical value to reduce the evaluation testing time. The sample size, number of inspections, and the critical values are determined to assure the same probability of acceptance when the testing time is reduced to some degree. Photo-diode balance of an optical pickup is analyzed as a case study.

  • PDF

Design Method and Evaluation of the Applicability of the Complex AAM Permanent Anchor (복합 AAM 영구 앵커의 설계법 및 적용성 평가)

  • Lee, Hyuk-Jin;Jung, Dae-Hoon;Kim, Jin-Hong;Lee, Chong-Ha;Kim, Hong-Taek
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.538-541
    • /
    • 2007
  • In this study, the complex AAM permanent anchor was introduced and the design method for the complex AAM permanent anchor was showed by examining the relationship of the forces applied to the anchor, the ground failure, the loads inducing the tensile failure between the anchors, etc. In order to understand the behavioral characteristics of the complex AAM permanent anchor, the field pullout test was carried out, and the results obtained with the design method were compared with those of the field pullout test.

  • PDF

Design and Integrity Evaluation of High-temperature Piping Systems in the STELLA-2 Sodium Test Facility (STELLA-2 소듐 시험 시설 고온 배관 계통의 설계 및 건전성 평가)

  • Son, Seok-Kwon;Lee, Hyeong-Yeon;Ju, Yong-Sun;Eoh, JaeHyuk;Kim, Jong-Bum;Jeong, Ji-Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.9
    • /
    • pp.775-782
    • /
    • 2016
  • In this study, elevated temperature design and integrity evaluation have been conducted using two different piping design codes for the high-temperature piping systems of sodium integral effect test loop for safety simulation and assessment(STELLA-2) being developed by KAERI(Korea Atomic Energy Research Institute). The design code of ASME B31.1 for power piping and French nuclear grade piping design guideline, RCC-MRx RD-3600 were applied, and conservatism of those codes was quantified based on the piping integrity evaluation results. The piping system of Model DHRS, Model IHTS and PSLS are to be installed in STELLA-2. The integrity evaluation results for the three piping systems according to the two design codes showed that integrity of the piping system was confirmed. As a code comparison result, ASME B31.1 was shown to be more conservative for sustained loads while RD-3600 was more conservative for thermal loads compared to B31.1.

Design Evaluation System with Visualization and Interaction of Mobile Devices Based on Virtual Reality Prototypes

  • Jo, Dong-Sik;Yang, Ung-Yeon;Son, Wook-Ho
    • ETRI Journal
    • /
    • v.30 no.6
    • /
    • pp.757-764
    • /
    • 2008
  • In this paper, we present a design evaluation system with visualization and interaction of mobile devices using virtual-reality-based prototypes which can be used to easily change design parameters and simulate embedded software. To evaluate and predict affective-engineering-based design preferences for mobile devices under a virtual environment, we have developed a high quality visualization platform which creates images that look similar to real mobile devices in addition to real-time simulation of realistic motions and functions of mobile devices. To support a quantitative usability test scenario for external design shape, we also have built a system which consists of a mixed-reality-based testing platform for measuring hand load.

  • PDF

Java programming lecture design considering NCS-based SW Qualification Design (NCS 기반 SW 신자격 설계를 고려한 자바프로그래밍 강의 설계)

  • You, EungGu
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.15 no.4
    • /
    • pp.131-136
    • /
    • 2019
  • As the NCS(National Competency Standards) classification system continued to be developed and supplemented, NCS became widespread. Qualifications were redesigned to actively reflect industry demands, reduce the burden of redundant acquisition of unnecessary qualifications, and to evaluate objective capacities of the workforce. In addition to the learning modules to be developed in the future, previously developed NCS-based learning modules and lectures should be reorganized based on the new qualification design. In this paper, the Java programming subject designed based on NCS was redesigned according to SW new qualification design. Since the redesigned Java programming subjects consider the qualification design direction or qualification roadmap, not only can they be recognized as a test subject in qualification assessment through course evaluation, but also can be used as individual qualification data.

Usability Test Guidelines for Speech-Oriented Multimodal User Interface (음성기반 멀티모달 사용자 인터페이스의 사용성 평가 방법론)

  • Hong, Ki-Hyung
    • MALSORI
    • /
    • no.67
    • /
    • pp.103-120
    • /
    • 2008
  • Basic components for multimodal interface, such as speech recognition, speech synthesis, gesture recognition, and multimodal fusion, have their own technological limitations. For example, the accuracy of speech recognition decreases for large vocabulary and in noisy environments. In spite of those technological limitations, there are lots of applications in which speech-oriented multimodal user interfaces are very helpful to users. However, in order to expand application areas for speech-oriented multimodal interfaces, we have to develop the interfaces focused on usability. In this paper, we introduce usability and user-centered design methodology in general. There has been much work for evaluating spoken dialogue systems. We give a summary for PARADISE (PARAdigm for Dialogue System Evaluation) and PROMISE (PROcedure for Multimodal Interactive System Evaluation) that are the generalized evaluation frameworks for voice and multimodal user interfaces. Then, we present usability components for speech-oriented multimodal user interfaces and usability testing guidelines that can be used in a user-centered multimodal interface design process.

  • PDF

A Study on the Usability test and Space Syntax analysis in Web Museum (Museum Web 공간의 사용성 평가와 구조분석에 관한 연구)

  • 최성욱;황미영;임채진
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2002.04a
    • /
    • pp.99-104
    • /
    • 2002
  • The main concept of this thesis is to research about how to express the interface element of the virtual museum on tile cyber space and how to evaluate its organization. In addition, the basis of this thesis is to help people build their efficient spaces on the current virtual museum. My understanding about the interface element and its structural evaluation is grounded on Usability evaluation and Syntax thesis. For the survey, I utilize two different methods. One is regular questionnaire; the other is heuristic evaluation which is derived from empirical study and practical experience. The survey is mainly composed of contents, design, usability and overall impression. The main concept of this research is to establish the initial foundation of the virtual museum on cyber space by suggesting an objective evolutional norm including esthetic orientation.

  • PDF

A Study on the Safety Evaluation of Bridge Footings using GPR (GPR 시험을 이용한 교량기초의 안전성 조사방법에 관한 연구)

  • Kim, Yong-Gon;Paik, Shin-Won
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.105-113
    • /
    • 2006
  • The footing of a bridge is a very essential part that support the whole load induced by the bridge itself and the traffic as well. However, once a bridge is built, the footing is buried under soil so the footing is invisible from outside. Therefore, the safety or condition of the footing is very difficult to estimate. Not only the length of the imbedded part of the footings but also the type of footings are unknown once the design record is gone. Some nondestructive techniques can be used to evaluate invisible part of the footings but the results have not been successful yet. Using GPR (Ground Penetrating Radar), which has been used for the nondestructive evaluation in military purposes, the condition assessment of the footings have been successfully conducted in this research. The field evaluation and laboratory tests have been conducted to find effective factors in the condition assessment of the footings. The equipment and basic theory of the GPR has been presented. The field test results show that the GPR can be successfully used for the safety evaluation of the footings. More test results and field data are needed for more precise evaluation of the footings.

Performance Evaluation of Solar Water Heating System Using Proof Test (태양열 온수기 실증연구를 통한 성능 평가)

  • Kim, Jae-Yeol;Kwac, Lee-Ku;Yang, Dong-Jo;Choi, Choul-Jun;Kim, Hong-Gun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.597-601
    • /
    • 2006
  • The advantages of solar energy are that it is renewable, infinite supplied and environmentally safe energy source. However, solar energy related products have the problems such as the limitation for installation, problems in maintenance and insufficient reliability which have been the barrier to consumers to satisfy the purchase need for solar heat related products. In this regard, in order to support the solar energy related companies the necessity for various technical information required for the commercialization of new products such as various performance test necessary for the certification of solar energy system, standardization for facilities and products, performance evaluation method and the measurement of performance is suggested. The purpose of this paper is to design the monitoring system for positive tests of system linked household hot water system using solar heat out of various solar energy systems, to establish an analysis and monitoring system for performance maintenance and operation technique, and to configure the centralized detection network by utilizing remote monitoring system. This research also aims at conducting monitoring for operation and performance evaluation in relation to database establishment and analytical evaluation and at describing the method of enhancing the reliability of solar energy system through the development of performance evaluation program.

  • PDF

Limited Ductile Capacity of Reinforced Concrete Bridge Pier with Longitudinal Steel Lap-splicing by Pseudo Dynamic Test (유사동적 실험에 의한 철근콘크리트 교각의 주철근 겹이음에 따른 한정연성능력)

  • 박창규;박진영;조대연;이대형;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.885-890
    • /
    • 2002
  • Pseudo dynamic test is an on-line computer control method to achieve the realism of shaking table test with the economy and versatility of the conventional quasi-static approach. Pseudo dynamic tests of four full-size RC bridge piers have been carried out to investigate their seismic performance. For the purpose of precise evaluation, the experimental investigation was conducted to study the seismic performance of the real size specimen, which is constructed for highway bridge piers in Korean peninsula. Since it is believed that Korea belongs to the moderate seismicity region, three test specimens were designed in accordance with limited ductility design concept. Another one test specimen was nonseismically designed according to a conventional code. Important test parameters were transverse reinforcement and lap splicing. Lap splicing was frequently used in the plastic hinge region of many bridge columns. Furthermore, the seismic design code is not present about lap splice in Korean Roadway Bridge Design Code. The results show that specimens designed according to the limited ductility design concept exhibit higher seismic resistance. Specimens with longitudinal steel lap splice in the plastic hinge region appeared to significantly fail at low ductility level.

  • PDF