• Title/Summary/Keyword: Design Scenario

Search Result 1,033, Processing Time 0.028 seconds

A Study on Daily Water Storage Simulation of the Daecheong Dam by Operation Scenario of the Yongdam Dam (용담댐 운영 시나리오에 따른 대청댐 저수량 변화에 관한 연구)

  • Noh Jaekyoung;Kim Hyun-hoo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1403-1407
    • /
    • 2005
  • In order to analyze the water storage of the Daecheong dam after constructing the Yongdam dam situated in upstream, a daily cascaded simulation model for analyzing water storages in the Yongdam-Daecheong dams was developed. Operation scenarios of the Yongdam dam were selected to 8 cases with the combinations of downstream outflows and water supplies to the Jeonju region. Daily water storages in the Daecheong dam was analyzed daily by simulating from 1983 to 2004. The results are summarized as follows. Firstly, water supplies from the Daecheong dam were analyzed to amount $1,964.2Mm^3$ on a yearly average in case without the Yongdam dam. In case with the Yongdam dam, water supplies from the Daecheong dam were analyzed to amount $1,858.7\~1,927.3Mm^3$ in case with downstream outflow of $5\;m^3$ is, and were analyzed to amount $1,994.9\~2,017.8Mm^3$ in case with downstream outflow of $10\;m^3/s $. These values are compared to $1,649Mm^3$ applied in design. Secondly, reservoir use rate which was defined rate of water supply to effective water storage reached $241.3\% in case without the Yongdam dam. In case with the Yongdam dam, reservoir use rate reached $228.3\~236.8\% In case with downstream outflow of $5\;m^3/s$, and reached $245.1\~247.9\% in case with downstream outflow of $10\;m^3/s$. Thirdly, runoff rate which is defined rate of dam inflow to areal rainfall reached $57.3\% in case without the Yongdam dam. In case with the Yongdam dam, reservoir use rate reached $62.0\~68.4\% in case with downstream outflow of $5\;m^3/s$, and reached $64.1\~68.5\% in case with downstream outflow of $10\;m^3/s$. Fourth, in case with downstream outflow of $10\;m^3/s$ is from the Yongdam dam, appropriate water supply amounts to the Jeonju region were analyzed to only $0.50Mm^3/day$ from the daily simulation of water storages in the Yongdam dam. Comprehensively, water supply capacity of the Daecheong dam was analyzed to affect in small amounts in spite of the construction of the Yonsdam dam. It is effected to achieve the effective water management of the Yongdam dam and the Daecheong dam by using the developed cascaded model.

  • PDF

Safety Assessment of Near Surface Disposal Facility for Low- and Intermediate-Level Radioactive Waste (LILW) through Multiphase-Fluid Simulations Based on Various Scenarios (다양한 시나리오 기반 유체거동 수치모사를 통한 중·저준위 방사성 폐기물 표층처분시설 안전성 평가)

  • Jeong, Jina;Kown, Mijin;Park, Eungyu
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.131-147
    • /
    • 2018
  • In the present study, the safety of the near surface disposal facility for low- and intermediate-level radioactive waste (LILW) is examined based on the fluid-flow simulation model. The effects of the structural design and hydrological properties of the disposal system are quantitatively evaluated by estimating the flux of infiltrated water at the boundary of the structure. Additionally, the safety margins of the disposal system, especially for the cover layer and vault, are determined by applying the various scenarios with consideration of possible facility designs and precipitation conditions. The overall results suggest that the disposal system used in this study is sufficiently suitable for the safe operation of the facility. In addition, it is confirmed that the soundness of both the cover layer and the vault have great impact on the safety of the facility. Especially, as shown in the vault degradation scenario, capability of the concrete barrier of the vault make more positive contribution on the safe operation of the facility compared to that of the cover layer.

A Study on Establishment of Buffer Zone of Radioactive Waste Repository (방사성패기물 처분시설에서의 완충공간 설정에 대한 고찰)

  • Yoon, Jeong-Hyoun;Park, Joo-Wan;Ju, Min-Su;Kim, Chang-Lak;Park, Jin-Baek
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.1
    • /
    • pp.45-54
    • /
    • 2008
  • A new proposed repository has a final capacity of 800,000 drums radioactive waste. Most of foreign repositories have a general practice of segregating control zones which mainly contributes to classification of degree of control, whether it is called buffer zone or not. Domestic regulatory requirements of establishment of buffer zone in a repository are not much different from those of nuclear power plants for operation period, in which satisfactory design objective or performance objective is the most important factor in determination of the buffer zone. The meaning of buffer zone after closure is a minimum requested area which can prevent inadvertant intruders from leading to non-allowable exposure during institutional control period. Safety assessment with drinking well scenario giving rise to the highest probability of exposure among the intruder's actions can verify fulfillment of the buffer zone which is determined by operational safety of the repository. At present. for the repository to be constructed in a few years, the same procedure and concept as described in this paper are applied that can satisfy regulatory requirements and radiological safety as well. However, the capacity of the repository will be stepwise extended upto 800,000 drums, consequently its layout will be varied too. Timely considerations will be necessary for current boundary of the buffer zone which has been established on the basis of 100,000 drums disposal.

  • PDF

A Study on Systematic Risk Assessment Method for LNG Storage Facilities (LNG 저장설비에 대한 체계적인 위험성평가 방법에 관한 연구)

  • Kang, Mee-Jin;Lee, Young-Soon;Lee, Seung-Rim
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.14-20
    • /
    • 2009
  • As the consumption of LNG has increased, the capacity and number of LNG facilities are getting bigger and bigger. Such circumstances supports the need for a dedicated risk analysis model to help review and check major issues of the safer construction and operation of LNG storage facilities systematically. Therefore this study suggests an appropriate risk analysis model that enables us to evaluate hazards of LNG storage facilities more easily and systematically, and then to use its result in siting, design and construction stages of the facilities. ill order to develop the model, lots of existing studies and domestic and foreign codes and standards were fully reviewed and a series of case studies also were carried out. The suggested model consists of 4-stage evaluations: in selecting a site, in determining a layout, in designing and constructing the facilities, and in operating them. This model also suggests the weather condition necessary for estimating the consequence of accident-scenarios, and the easy, systematic approach to the analysis of their probability. We expect that the model may help secure LNG storage facilities' inherent safety in determining their site and layout.

  • PDF

A Study on the Quantitative Process Facility Standards that Require H2S Toxic Gas Detectors and Location Selection for Emergency Safety (H2S 독성가스감지기가 필요한 정량적 공정설비 기준 및 비상시 안전을 위한 위치선정 방안에 대한 연구)

  • Choi, Jae-Young;Kwon, Jung-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.2
    • /
    • pp.90-96
    • /
    • 2018
  • Design techniques for minimizing the damage caused by leakage of $H_2S$ gas, contained in natural gas and petroleum, have been widely studied abroad in chemical plants that purify and process natural gas and petroleum. However, there is no domestic engineering practice and regulation of $H_2S$. In accordance with the circumstances, this study proposes the quantitative criteria of process equipment to install $H_2S$ toxic gas detector as 500 ppm and explains the valid basis. The $H_2S$ gas dispersion radius up to IDLH 100 ppm is calculated by ALOHA under previous $H_2S$ gas leak accident scenario. The weather conditions of modeling include the conditions of Ulsan, Yeosu and Daesan, the three major petrochemical complexes in Korea. The long radius up to 100 ppm was derived in order of Ulsan, Daesan, Yeosu. For emergency safety the dispersion radius up to 100 ppm of the $H_2S$ gas obtained in this study should be extended to apply the additional $H_2S$ toxic gas detector, and local climate conditions should be considered.

Development of mobile-application based cognitive training for Menopausal Women with Cognitive Complaints (갱년기 여성을 위한 앱 기반의 인지기능훈련 프로그램 개발)

  • Kim, Ji-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.150-166
    • /
    • 2020
  • Based on the theory of cognitive reserve, we undertook this study to develop a cognitive function training program for woman in menopausal transition with complaints of declining in cognitive function. The program was established by applying the analysis, design, and development stages of the network-based instructional system designed by Jung. The cognitive function training program developed by us is an was an 8-week program composed of cognitive and video training using a mobile application. The program consists of 24 sessions, each with 20-30 minutes of duration, to be completed 3 sessions per week. The contents of the cognitive function training comprise of memory, attention, language function, and scenario-based problem-solving for executive functions, all of which are cognitive areas found to be the most vulnerable for menopausal women. The educational contents were developed for eight subject areas, one subject area per week, including the definition of menopause, its causes and symptoms, menopause and brain function, etc. During the pilot test, the cognitive function training program was applied to 10 menopausal women who complained of cognitive function decline. The results indicated that, after eight weeks of training, the overall cognitive function of participants increased, revealing statistically significant differences (t=-3.04, p=.014) after the program was completed. The mobile app-based cognitive function training program might not only improve patients' memory functions but also potentially reduce the incidence of dementia.

The Effects of Simulation-based Education on the Clinical Reasoning Competence, Clinical Competence, and Educational Satisfaction (시뮬레이션 교육이 간호학생의 임상추론역량과 임상수행능력 및 교육만족도에 미치는 효과)

  • Kang, Hee;Kang, Hee-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.107-114
    • /
    • 2020
  • This study was conducted to examine the effects of simulation-based education on the clinical reasoning competence, clinical competence, and satisfaction with simulation experience (SSE). The research design was one group pretest-posttest. Study participants were 89 third-year nursing students from C University in G city, who were engaged the simulation-based education for eight weeks from August to October 2019. Learning scenario titles were blood transfusion reaction patient care with postoperative total hip replacement, hypoglycemia patient care with diabetes mellitus, and hyperkalemia patient care with liver cirrhosis. The data were analyzed by paired t-test using SPSS Win 23.0 program. After applying simulation-based education, nursing students' clinical reasoning competence (t=-17.082, p<.001) and clinical competence(t=-18.40, p<.001) improved significantly. SSE score was 4.65 out of 5 points. The results indicate that the simulation-based education in this study gave the students the experience of providing qualified and secure nursing care under conditions similar to those in the real clinical field. To improve the clinical reasoning competence and clinical competence of nursing students, various cases scenarios are developed and simulation-based education should be applied to more subjects in the nursing curriculum.

A Study of China's Condition as the Logistics Hub of Northeast Asia and a Development Strategy (중국의 동북아 물류중심화 현황과 발전전략에 관한 연구)

  • Oh, Moon-Kap
    • Journal of Distribution Science
    • /
    • v.12 no.2
    • /
    • pp.95-103
    • /
    • 2014
  • Purpose - Korea has a better geographical location than other nations in the Northeast Asian region. This means that Korea has an opportunity to become the center of international physical distribution in Northeast Asia. Korea should take advantage of this opportunity by exploring appropriate strategies to achieve this goal, assuming government willingness, with a view to capitalizing on the geographical advantage of the Korean peninsula and constructing a comprehensive physical distribution network system. If we prepare for this scenario, Korea could become the center of international physical distribution in Northeast Asia. Research design, data, and methodology - This study has the purpose of determining how shipping companies form partnerships with third-party logistics providers, and the relevant implications. The survey methods used were personal interview and a questionnaire distributed through e-mail, fax, mail, and telephone. A total of 600 questionnaires were distributed, out of which 285 were returned. Of the collected questionnaires, 10 were excluded because of insufficient content, leaving 275 to be used in the study as available valid samples. The data that was collected from these samples was analyzed using the data coating process and by employing a statistical package program. Results - Flexible policies, administration, and systems will be needed to create better business practices. In this dissertation, first and foremost, the results reveal that in order to become the center of Northeast Asian logistics, Korea must transition into a new paradigm based on the current economic and social systems that have stemmed from bureaucracy, inflexibility, chauvinism, and egalitarianism. Flexible policies, administration, and systems will be required to create better business practices. Domestic logistics corporations need to occupy a strategic logistics hub, create a logistics network, and activate value-added logistics business strategies by ensuring significant manpower and by building a logistics information system to strengthen their competitive edge, creating an improved system. Conclusions - In this dissertation, first and foremost, we point out that in order to become a center of North East Logistics, Korea should change to a new paradigm from the old one based on current economic and social systems that have stemmed from bureaucracy, inflexibility, chauvinism, and egalitarianism. More reasonable business laws, systems, and policies based on market-driven flexibility and transparency should be created. Moreover, social norms and rules should be reasonably established, to accomplish political and social security. Korea has to cultivate a culture of tolerance for foreign companies. This involves a change of paradigm for the development of the capital city and satellite cities. It will take a powerful task force or organization to plan and execute the vision that aims to meet these needs, accomplish the necessary goals, use the appropriate system effectively, and make Korea a key country in the field of Northeast Asian logistics.

Design of Serendipity Service Based on Near Field Communication Technology (NFC 기반 세렌디피티 시스템 설계)

  • Lee, Kyoung-Jun;Hong, Sung-Woo
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.4
    • /
    • pp.293-304
    • /
    • 2011
  • The world of ubiquitous computing is one in which we will be surrounded by an ever-richer set of networked devices and services. Especially, mobile phone now becomes one of the key issues in ubiquitous computing environments. Mobile phones have been infecting our normal lives more thoroughly, and are the fastest technology in human history that has been adapted to people. In Korea, the number of mobile phones registered to the telecom company, is more than the population of the country. Last year, the numbers of mobile phone sold are many times more than the number of personal computer sold. The new advanced technology of mobile phone is now becoming the most concern on every field of technologies. The mix of wireless communication technology (wifi) and mobile phone (smart phone) has made a new world of ubiquitous computing and people can always access to the network anywhere, in high speed, and easily. In such a world, people cannot expect to have available to us specific applications that allow them to accomplish every conceivable combination of information that they might wish. They are willing to have information they want at easy way, and fast way, compared to the world we had before, where we had to have a desktop, cable connection, limited application, and limited speed to achieve what they want. Instead, now people can believe that many of their interactions will be through highly generic tools that allow end-user discovery, configuration, interconnection, and control of the devices around them. Serendipity is an application of the architecture that will help people to solve a concern of achieving their information. The word 'serendipity', introduced to scientific fields in eighteenth century, is the meaning of making new discoveries by accidents and sagacity. By combining to the field of ubiquitous computing and smart phone, it will change the way of achieving the information. Serendipity may enable professional practitioners to function more effectively in the unpredictable, dynamic environment that informs the reality of information seeking. This paper designs the Serendipity Service based on NFC (Near Field Communication) technology. When users of NFC smart phone get information and services by touching the NFC tags, serendipity service will be core services which will give an unexpected but valuable finding. This paper proposes the architecture, scenario and the interface of serendipity service using tag touch data, serendipity cases, serendipity rule base and user profile.

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.