• 제목/요약/키워드: Design Interaction

Search Result 4,325, Processing Time 0.035 seconds

A Study on the Expansion Joint of Concrete Lining and Duct in a Tunnel (터널 콘크리트 라이닝 및 공동구 신축이음 설치방안에 관한 연구)

  • Son, Moorak;Park, Yangheum;Park, Yunjae;Kim, Jaegyoun;Yoon, Jongcheol
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.3
    • /
    • pp.39-50
    • /
    • 2015
  • The installation of the expansion joints in a tunnel concrete lining and duct would minimize the cracking at the location of structural shape and stiffness change, differential settlement, big temperature change, and so on. However, it is difficult to determine the required spacing of the expansion joint in a tunnel concrete lining and duct quantitatively because the spacing is influenced by temperature change, structure construction condition, ground-structure interaction, and etc. Nevertheless, a highway specification (Korea Expressway Corporation, 2012) or a road design manual (Ministry of Land, Transport and Maritime Affairs, 2010) specifies that the expansion joint spacing in a tunnel concrete lining should be installed uniformly smaller than 25 m from the tunnel portals to 50 m inside of a tunnel and elsewhre 20-60 m in a tunnel (because there is no specifcation for a duct it is assumed that a duct follows the specfication of lining). This specification results in several construction and economic problems in relation with a tunnel construction. Accordingly, in order to minimize the problems, this study analyzed both domestic and foreign design standards and specifications. In addition, field test, theoretical and numerical analyses were carried out in relation to the expansion joint in a tunnel lining and duct. The purpose of this study is to reestabilish a criterion for installing the expansion joint in a tunnel concrete lining and duct.

A Study on the MDAS-DR Antenna for Shaping Flat-Topped Radiation Pattern (구형 빔 패턴 형성을 위한 MDAS-DR 안테나에 대한 연구)

  • Eom, Soon-Young;Yun, Je-Hoon;Jeon, Soon-Ick;Kim, Chang-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.3 s.118
    • /
    • pp.323-333
    • /
    • 2007
  • In this paper, a new MDAS-DR antenna structure designed to efficiently shape a flat-topped radiation pattern is proposed. The antenna structure is composed of a stacked micro-strip patch exciter and a multi-layered disk array structure(MDAS) surrounded by a dielectric ring. The MDAS, which was supplied by a stacked microstrip patch exciter with radiating power, can form a flat-topped radiation pattern in a far field by a mutual interaction with the surrounding dielectric ring. Therefore, the design parameters of the dielectric ring and the MDAS structure are important design parameters for shaping a flat-topped radiation pattern. The proposed antenna used twelve multi-layered disk array elements and a Teflon material with a dielectric constant of 2.05. An antenna operated at 10 GHz$(9.6\sim10.4\;GHz)$ was designed in order to verify the effectiveness of the proposed antenna structure. The commercial simulator of CST Microwave $Studio^{TM}$, which was adapted to a 3-D antenna structure analysis, was used for the simulation. The antenna breadboard was also fabricated and its electrical performance was measured in an anechoic antenna chamber. The measured results of the antenna breadboard with a flat-topped radiation pattern were found to be in good agreement with the simulated one. The MDAS-DR antenna gain measured at 10 GHz was 11.18 dBi, and the MDAS-DR antenna was capable of shaping a good flat-topped radiation pattern with a beam-width of about $40^{\circ}$, at least within a fractional bandwidth of 8.0 %.

The Optimization of RF Atmospheric Pressure Plasma Treatment Process for Improving the Surface Free Energy of Polymethylmethacrylate (PMMA) (Polymethylmethacrylate (PMMA) 표면개질을 위한 RF 대기압 플라즈마 처리공정의 최적화)

  • Nam, Ki-Chun;Myung, Sung-Woon;Choi, Ho-Suk
    • Journal of Adhesion and Interface
    • /
    • v.6 no.3
    • /
    • pp.1-9
    • /
    • 2005
  • This study investigated the influence of atmospheric plasma factors such as RF power, treatment time, the gap distance between discharge and sample, and the gas flow rate of Ar on the surface property by using the design of experiment (DOE) method. The plasma treatment time (s), plasma power (W), gap distance (mm) between discharge and sample, and flow rate of Ar gas were in order of important factors for changing the surface free energy of PMMA plates. As a result, the most effective factor for improving the surface free energy of PMMA plates is the distance (mm) from discharge glow to sample plate. Because of the interaction between plasma power (W) and treatment time (s), the power dose (J) factor which multiply plasma power (W) by treatment time (s) should be significantly considered. The optimum condition for maximizing the surface free energy of PMMA plate was found at 1500J of power dose. Through XPS and AFM analysis, we also observed the change of chemical composition, surface morphology and roughness before and after plasma treatment. It is considered that the change of surface free energy of PMMA plate with plasma treatment is influenced by the introduction of polar functional group as well as the increase of surface roughness.

  • PDF

A Study on the Characteristics of Bonsai Industry in Korea, China and Japan (한·중·일 분재산업의 특성에 관한 연구)

  • Yoo, Su-Hyung;Jeong, Joon-Rae;Park, Yool-Jin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.119-126
    • /
    • 2019
  • For this purpose, research was made to look into the style, material, organization, and legal as well as institutional system of the bonsai industry in the three countries. In order to understand what significance it has and how it has changed historically, related literature was surveyed and questionnaires were distributed to the concerned people to collect the data needed for them to plan bonsai industry. The results of the survey are as follows. Analysis of awareness of bonsai culture, respondents replied that the motive and purpose of bonsai is because they like flower trees, and the technical information about bonsai is usually obtained by visits to bonsai gardens. The analysis revealed that respondents usually join more than one bonsai club and are active more than once a month, which means longer than 4 hours each month, and their activities are more frequently in the metropolitan area. From the analysis of preference for bonsai culture, it was made known that the favorite bonsai size is less than middle one(20~50cm), the characteristics of the favorite species are beauty. A research and analysis of bonsai-related technical education found that bonsai is trimmed manually in general, bonsai experts are usually kept in contact with, and the bonsai technique is learned through interaction with the experts.

3-D Simulation of Pyroelectric IR Sensor and Design of Optimized Peripheral Circuit (초전형 적외선 센서의 3차원 모델링과 최적화된 주변회로 설계)

  • Min, Kyung-Jin;Kang, Seong-Jun;Yoon, Yung-Sup
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.10
    • /
    • pp.33-41
    • /
    • 2000
  • Pyroelectric characteristics such as voltage responsivity, noise equivalent power and detectivity are modeled 3-dimensionaly considering th interaction of each parameters. Also, the circuit is designed to set up the frequency band width and the signal amplification of the pyroelectric IR sensor. The case of low frequency region shows that the voltage response increases with the independence of the sensor area as the thickness decreases. In the high frequency region, it is found that the voltage response with the load resistor of 20$G{\Omega}$ increases with the independence of the sensor thickness as the sensor area decreases. In the low frequency region, the detectivity becomes excellent at th load resistor of 20$G{\Omega}$, the sensor area larger than $4{\times}10^{-10}m^2$ and the sensor thickness thinner than $1{\times}10^{-5}m$, while, in the high frequency region, it shows high value at the sensor thickness thinner than $1{\times}10^{-5}m$ and the sensor area smaller than $2{\times}10^{-10}m^2$ with the independence of the load resistor. In the circuit design, quasi-boot-strap circuit is employed, in which a single op-amp is connected to the drain of JFFT. Desirable frequency band width, amplification rate and the remarkable drop of noise of about 56% from that of conventional circuits with double op-amps are obtained.

  • PDF

A Study of the Effects of Health Contracting on Compliance with Health Behaviors in Clients with Hypertension (자가간호증진을 위한 건강계약이 고혈압자의 건강행위 이행에 미치는 영향)

  • 이향련
    • Journal of Korean Academy of Nursing
    • /
    • v.17 no.3
    • /
    • pp.204-217
    • /
    • 1987
  • It is generally accepted that the delivery of health care is undergoing many changes specially those related to acute, contagious disease care and to the increase of chronic illnesses which can not be cured but are controlable. The health care practitioner can not be soley responsible for the control of their clients' care. Because the clients will play a vital role in controlling their illnesses, long term participation by both the health care provider and the client is necessary. Since most individuals with hypertension do not experience signs or symptoms, the disease is difficult to detect and even when diagnosed, clients do not comply well with their hypertension regimens. The noncompliant client is at increased risk for compliants involving the heart, brain, kidney and other organs. In an effort to explore methods of increasing patient participation in and adherence to treatment programs for hypertension, the researcher used health contracting to promote self care. The research questions are; 1) Will the health contracting increase compliance in health behavior and reduce the blood pressure\ulcorner 2) If clients comply with their regimens will this reduce their blood pressure\ulcorner The research design utilized in this study was a quasi-experimental design. A purposive sample, was abtained from two churches in the 1. area, consisting of 64 clients with hypertension. The data was collected from the middle of January to the 1st of September 1985. Randomization was only of the two church groups into experimental and control groups. Compliance with health behavior related to the hypertensive regimen, blood pressure and body weight were measured, compared and analyzed. In the experimental group measurements were made 6 times; one month before the education program after education program when health contracting was done and 4 more times once a month for 4 months. In the control group measurements were made 3 times; one month before the education program after the education program, and once 4 months later. There was no health contracting. The data were analyzed by t-test, Pearson correlation and ANOVA according to purpose of the study. The result of this study may be summarized as follows: The result related to the hypothesis on the effect of health contracting are as follows: H$_1$; “The hypothesis that the experimental group, with a health contractual agreement will demonstrate increased compliance levels for health behavior than the control group” was supported(t=-5.29, df=62, p=.000). H$_2$; “The hypothesis that the experimental group, with a health contractual agreement, will demonstrate a greater reduction in blood pressure than the control group” was supported (for systolic blood pressure t=2.72, df=62, p=.009, for diastolic blood pressure t=1.95, df=62, p=.050). H$_3$; The hypothesis that the greater the compliance of the client with health behavior the lower the client's blood pressure will be was partially supported (for systolic pressure r=-.2981, p=.008, for diastolic pressure r=-.1720, p=.087). From the examination of the results of this study it can be concluded that the interaction between the nurse and the client, contracting to define goals and reinforcing compliant behavior, leads to improved compliance with health care behaviors and thus to an increase in the effectiveness of nursing care. Further consideration need to be given to the inclusion of the concept of health contracting in primary nursing and to further research in this area.

  • PDF

Required Strength Spectrum of Low-Rise Reinforced Concrete Shear Wall Buildings with Pilotis (필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 요구내력 스펙트럼)

  • Lee, Kang-Seok;Oh, Jae-Keun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.61-69
    • /
    • 2007
  • The main purpose of this study is to provide a basic information for the seismic capacity evaluation and the seismic design of low-rise reinforced concrete (RC) shear wall buildings, which are comprised of a pilotis in the first story. In this study, relationships between strengths and ductilities of each story of RC buildings with pilotis are investigated based on the nonlinear seismic response analysis. The characteristics of low-rise RC buildings with pilotis are assumed as the double degree of freedom structural systems. In order to simulate these systems, the pilotis is idealized as a degrading trilinear hysteretic model that fails in flexure and the upper story of shear wall system is idealized as a origin-oriented hysteretic model that fails in shear, respectively. Stiffness properties of both models are varied in terms of story shear coefficients and structures are subjected to various ground motion components. By analyzing these systems, interaction curves of required strengths for various levels of ductility factors are finally derived for practical purposes. The result indicates that the required strength levels derived can be used as a basic information for seismic evaluation and design criteria of low-rise reinforced concrete shear wall buildings having pilotis structure.

Analysis of Factors Hindering Learners' Participation in Cyber Home Study in Elementary Education (초등교육에서 사이버가정학습 참여 저해요인 분석)

  • Shin, Hyeon-Jeong;Kim, Sung-Wan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.18 no.2
    • /
    • pp.175-182
    • /
    • 2013
  • The purpose of this study was to investigate the factors that influence elementary school learners' participation in cyber home study, and to suggest possible solutions to problem of the participation rates. To identify the factors, we analyzed the literature and developed a questionnaire consisting of 8 possible factors and 33 items. Data gathered from 429 elementary school learners were analyzed in a logistic regression model, which was utilized to determine the probability of the learner's participation in cyber home study because of any of the identified variables. We studied the following variables: problem from learning motivation & attitude, burden from computer, difficulty of new learning method, problem from instructional design, difficulty of interaction, problem from screen design, and problem from learning environment. The results indicated that two factors were important: burden from computer, difficulty of new learning method. That is to say, having a low level of burden of computer and difficulty of new learning method helps improve the rate of elementary school learners' participation in cyber home study.

Secondary Buckling Behavior Analysis on the Ship's Plate under Combined Load(Lateral Pressure Load and Axial Compressive Load) (조합하중을 받는 선체판부재의 2차좌굴거동 해석)

  • Park Joo-Shin;Ko Jae-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.1 s.24
    • /
    • pp.67-74
    • /
    • 2006
  • The ship plating is generally subjected to combined in-plane load and lateral pressure loads. In-plane loads include axial load and edge shear, which are mainly induced by overall hull girder bending and torsion rf the vessel. Lateral pressure is due to water pressure and cargo. These load components are not always applied simultaneously, but more than one can normally exist and interact. Hence, for more rational and safe design rf ship structures, it is of crucial importance to better understand the interaction relationship of the buckling and ultimate strength for ship plating under combined loads. Actual ship plates are subjected to relatively small water pressure except for the impact load due to slamming and panting etc. The present paper describes an accurate and fast procedure for analyzing the elastic-plastic large deflection behavior up to the ultimate limit state of ship plates under combined loads. In this paper, the ultimate strength characteristics of plates under axial compressive loads and lateral pressure loads are investigated secondary buckling behavior through ANSYS elastic-plastic large deflection finite element analysis with varying lateral pressure load level.

  • PDF

Optimization of Ethanol Extraction Conditions for Antioxidants from Zizyphus jujuba Mill. Leaves Using Response Surface Methodology (반응표면분석법을 이용한 대추잎 항산화물질의 에탄올추출조건 최적화)

  • Min, Dul-Lae;Lim, Seok-Won;Ahn, Jun-Bae;Choi, Young-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.6
    • /
    • pp.733-738
    • /
    • 2010
  • The leaves of Zizyphus jujuba have been used for various purposes including medicine and nutrition. In this study, the conditions for the ethanol extraction of antioxidant from Zizyphus jujuba were optimized using response surface methodology (RSM). A Box-Behnken design containing 15 experimental runs with three replicates was employed to study the effects of solvent extraction conditions such as extraction temperature ($^{\circ}C$, $X_1$), extraction time (min, $X_2$), and ethanol concentration (%, $X_3$) on the extraction yield of antioxidants from Zizyphus jujuba. The yields of total polyphenols and total flavonoid, and electron donating activity (EDA) were considered as response variables. The second-order polynomial model gave a satisfactory description of the experimental results showing different patterns of extraction conditions with variation in the linear, quadratic, and interaction effects of the independent variables. Based on four-dimensional RSM, one of the optimized sets of conditions was 45% ethanol, $45^{\circ}C$, and an extraction time of 15 min. Under the optimal conditions, the predicted values were 177.64 mg/g dry basis, 35.99 mg/g dry basis, and 86.14% Vit.C equivalents for total polyphenols, total flavonoids, and EDA, respectively. The experimental values showed good agreements with the predicted values.