• Title/Summary/Keyword: Design Generator

Search Result 2,019, Processing Time 0.028 seconds

Rotordynamic Design and Analysis of the Rotor-Bearing System of a 500Wh Flywheel Energy Storage Device (플라이휠 에너지 저장장치 회전체계의 동역학적 설계및 해석)

  • 최상규;김영철;경진호
    • Journal of KSNVE
    • /
    • v.8 no.1
    • /
    • pp.81-86
    • /
    • 1998
  • A 500Wh class high-speed Flywheel Energy Storage System (FESS) driven by a built-in BLDC motor/generator has been designed, which runs from 30000 to 60000rpm nominally. Due to the motor/generator inside, the flywheel rotor made of composites supported by PM/EM hybrid bearing system has a shape of bell or pendulum and thus requires accurate rotordynamic analysis and prediction of its dynamic behavior to secure the operating reliability. Rotordynamic analyses of the flywheel rotor-bearing system revealed that the bell shaped rotor has two conical rigid-body modes in the system operating range and the first conical mode, of which nodal point lies in the radial EM bearing position, can adversely affect the dynamic response of the rotor at the corresponding critical speed. To eliminate the possibility of wild behavior of the rotor, two guide bearings are adopted at the upper end of the rotor and motor/generator. It was also revealed that the EM bearing stiffness if 0.5~1.0E+6 N/m and damping of 2000 Ns/m are favirable for smooth operation of the system around the 2nd critical speed.

  • PDF

Research on SPMS for Pulsating Load based on Communication Network (통신 네트워크 기반의 맥동 부하용 SPMS에 관한 연구)

  • Oh, Jin Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.4
    • /
    • pp.927-933
    • /
    • 2014
  • Ship Power Management System(SPMS) based on Communication Network(CN) is one of the most significant factor for a safe voyage. Therefore, most of the vessels are using greater capacity generator than necessary to prevent pulsating load for safety purposes. However, It provokes low-load damage and reduces generator efficiency that using large capacity generator. Accordingly, in this paper propose hybrid power system for prevent damage of pulse load. Simulation using NI's LabVIEW was conducted for the design of the power system based on actual navigation data of the ship. Also, propose applying methods for hybrid power system in connection with the auxiliary power system for safe navigation.

Design and Implementation of the frequency Monitoring System for the Small AC Generator (소형 AC 발전기의 주파수 모니터링 시스템 설계 및 구현)

  • Park, Ji-sang;Jeon, Min-ho;Lee, Myung-eui
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.997-999
    • /
    • 2013
  • In this paper, the frequency monitoring system for the small AC generator having two or more generator is designed and implemented to synchronize a voltage, phase and frequency for stable power supply. CT sensor is used to measure the amount of current flowing in the power line, and PT sensor is used to measure the amount of voltage across the power line. The experimental results show that the power frequency can be measured using the power frequency monitoring system developed in this paper. The frequency monitoring system proposed in this paper will be able to control the power generation system using two or more small generator efficiently.

  • PDF

Development of Digital Chirp Pulse Generator for Fine Resolution Image Radar (고해상도 레이더용 광대역 디지털 첩 펄스 발생기 실험모델 개발)

  • 강경인;임종태;신희섭;전재한
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.8
    • /
    • pp.104-108
    • /
    • 2006
  • There are range and azimuth direction resolution of synthetic aperture radar on the aircraft or satellite. Wide bandwidth chirp pulse generation technology is prerequisite for SAR image with fine resolution. There are two kinds of digital chirp pulse generation technology as arbitrary waveform generator(AWG) and direct digital synthesizer(DDS). In this paper, we design and implement a digital chirp pulse generator to generate 300MHz wide bandwidth linear FM chirp pulse for the fine resolution image with direct digital synthesizer. Implemented chirp pulse generator can be useful for the SAR sensors to make 50cm range resolution image.

Study for generation of standard EM field using 8 ports-variable wave impedance generator (8단자 가변 임피던스 전자파 발생 장치를 이용한 표준 복사 전자기장 조성 연구)

  • 윤재훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.3
    • /
    • pp.771-783
    • /
    • 1996
  • A desing technique of 8 ports variable wave impedance generator (8P-VWIG) is described. The design technique employs not only a numerical algorithm to find the structure with arbitrary characteristic impedance, but also a numerical solution to analyze the uniform elementrognentic fields established inside the generator. The 8P-VWIG so obtained is shown to have good performance with the VSWR of less than 1.4 at any frequency of interest below which higher order mode begin to propagate. The measured first resonant frequency is 152.1 MHz. The 8P-VWIG is designed based on the concept of an expanded multi-transmission line(8 channel). It is especially useful for the electronmagnetic interference(EMI) and electronmagnetic susceptibility(EMS) testing since it maximizes usable test crosssectional area, and its is easy change the polarization, vertical or horizontal, of field.

  • PDF

A Design of Analog Front-End for Noncoherent UWB Communication System

  • Yong Moon Kwan-Ho;Choi Sungsoo;Oh Hui Myong;Kim Kwan-Ho;Lee Won Cheol;Shin Yoan
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.77-81
    • /
    • 2004
  • In this paper, we propose a analog front-end (AFE) for noncoherent On-Off Keying (OOK) Ultra Wide Band (UWB) system based on power detection. The proposed AFE are designed using 0.18 micron CMOS technology and verified by simulation using SPICE. The proposed AFE consist of Sample-and-Hold block, Analog-to-Digital converter, synchronizer, delayed clock generator and impulse generator. The time resolution of 1ns is obtained with 100MHz system clocks and the synchronized 10-bit digital outputs are delivered to the baseband. The impulse generator produces 1ns width pulse using digital CMOS gates. The simulation results show the feasibility of the proposed UWB AFE systems.

  • PDF

A Study on Design of the Compensation System for Wind Energy Generation by Power Storage Apparatus (동력저장장치를 이용한 풍력발전 보상 시스템 설계에 관한 연구)

  • 윤석암;차인수;백행래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.43-48
    • /
    • 2001
  • In conventional wind generation systems, since the blade rotates at low speed when the velocity of wind decreases their operations are possible only under limited conditions. Therefore they are in trouble of self-generation without the help of auxiliary generation devices outside. In addition, most of them have very low usage efficiency because of the characteristic changes of wind. For the solution of these problems and for enough generation regardless of districts and geographical features the rotation energy stored in a spring drives a compact generator and then electric power is stored at battery and supplied to the load continuously according to the lack of wind force. In this paper, the fabricated system consisting of a wind generator and power storage apparatus was introduced and its operation characteristics were analyzed.

  • PDF

Characteristics of electric power for thermoelectric generating module (열전발전용 소자를 이용한 열전발전기의 발전 특성)

  • Woo, B.C.;Lee, H.W.;Lee, D.Y.;Kim, B.S.;Kim, B.G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1614-1616
    • /
    • 2000
  • The purpose of this study is to manufacture and test a thermoelectric generator which converts unused energy from close-at-hand sources, such as garbage incineration heat and industrial exhaust, to electricity. A manufacturing process and the properties of a thermoelectric generator are discussed before simulating the thermal stress and thermal properties of a thermoelectric module located between an aluminum tube and alumina plate. We can design the thermoelectric modules having the good properties of thermoelectric generation. Resistivity of thermoelectric module for thermoelectric generation consisting of 62 cells was $0.15{\sim}0.4{\Omega}$. The maximum power of thermoelectric generator using thermoelectric generating modules can be defined as temperature function, and in this case it can be analogized the linear relation between current and voltage characteristics as function of temperature. The thermoelectric generator using 128 generating modules was assembled with 4 parallel connected modules sets composed with 32 directly connected modules.

  • PDF

Hot-firing Test Results of Subscale Gas Generator for 75 ton-class Liquid Rocket Engine (75톤급 액체로켓엔진 축소형 가스발생기 연소시험 결과)

  • Kim, Mun-Ki;Ahn, Kyu-Bok;Lim, Byoung-Jik;Kim, Jong-Gyu;Seo, Seong-Hyeon;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.726-728
    • /
    • 2010
  • A subscale gas generator was designed and manufactured to investigate the effect of design parameters on discharge coefficients of injectors for a 75 ton-class gas generator and hot-firing tests were successfully performed. The test results showed that discharge coefficients of fuel and liquid oxygen injectors remained nearly constant irrespective of variations of a mixture ratio and a chamber pressure. When the post diameter of the liquid oxygen injector was reduced, the discharge coefficient was increased as the pressure drop of the injector was decreased.

  • PDF

Control law design of gas generator for secondary combustion (이차 연소를 위한 가스발생기의 압력 제어기법 연구)

  • Park, Ik-Soo;Lee, Jae-Yoon;Choi, Ho-Jin;Yoon, Hyun-Gull;Lim, Jin-Shik
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.565-568
    • /
    • 2010
  • A pressure control law to regulate mass flow rate of gas generator is suggested. The governing equation is modeled by considering the burning rate of solid propellant and the conservation equation of gas generator. And then, a classical control law is applied after verifying the accuracy of dynamic model through comparing with ground test and internal ballistic results. The results show degradation of performance as shown in typical time varying system. To overcome this problem, an adaptive scheme is suggested and the performance is verified through numerical simulation.

  • PDF