• Title/Summary/Keyword: Desalination process

Search Result 182, Processing Time 0.023 seconds

A Study of Extracting Appropriate Conditions for Efficient Desalination for the Underwater Archaeological Ceramics from Ma Island in Taean (태안 마도출토 도자기의 효율적 탈염처리를 위한 조건도출 연구)

  • Nam, Byeong-Jik;Park, Dae-Woo;Kang, Hyun-Mi;Jang, Sung-Yoon;Jung, Yong-Hwa
    • Journal of Conservation Science
    • /
    • v.26 no.2
    • /
    • pp.133-142
    • /
    • 2010
  • This paper focused on desalination method for the underwater archaeological ceramics. The desalination method applied in this study takes additional conditions such as the amount of desalting water, temperature, and agitation conditions and compares the effects of desalt process. The result of efficiency rate appears that the twenty-times of the object weight of desalting water is more effective than that of ten-times one, but shows less economic compared to the cost. In addition, the research shows that the efficiency rate has been improved around 20 to 30 %, yet such improvement is not taken into account as an effective result considering the risk of damage from the physical and chemical impact and the consumption of energy in applying additional method.

Preparation and Properties of Cellulose Triacetate Membranes for Reverse Osmosis (역삼투용 Cellulose Triacetate 막의 제조와 특성)

  • Nam, Sang-Yong;Hwang, Hae-Young;Koh, Hyung-Chul
    • Membrane Journal
    • /
    • v.17 no.4
    • /
    • pp.277-286
    • /
    • 2007
  • The technology of seawater desalination has been received much attentions to solve the problem of water shortage through all over the world. In this study, it attempts to confirm the use-possibility of cellulose triacetate (CTA) for preparation of reverse osmosis membranes which have been highlighted as high efficiency and low energy consumption process for seawater desalination. The effects of casting dope parameters like an acetyl content, solvent, additives on the membrane performance were investigated. It was possible to produce the membranes which have high water flow rate and salt rejection with the increase of acetyl content and dioxane content among various dioxane/acetone ratios. Acetic acid and maleic acid were preferred for additives to produce high performance membranes. It was verified that $HOLLOSEP^{(R)}$ module which is commercialized CTA membrane by TOYOBO Co. can produce stable water production and high-quality water for long-term operation in the practice plants without any chemical treatments.

Effect of Current Density and Electroosmotic Phenomena on the Desalination Performance of the Electrodialysis Process (전류밀도와 전기삼투 현상이 전기투석 공정의 탈염성능에 미치는 영향)

  • Eun-Seo Cheon;Jae-Hwan Choi
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.272-278
    • /
    • 2023
  • In this study, we analyzed the effects of current density and electroosmotic phenomena on the desalination performance of electrodialysis (ED). We conducted ED experiments under constant voltage conditions, changing the concentration of the concentrate solution from 10 to 200 g/L. During the ED operation, we measured the current density and charge supplied to the stack, the concentration of the diluted and concentrated solutions, and the amount of water transported by electroosmosis to analyze desalination performance. As the concentration of the concentrated solution increased, the selectivity of the ion exchange membrane decreased, resulting in a decrease in current efficiency. Moreover, the current efficiency was found to be influenced by the current density supplied. When the current density exceeded 15 mA/cm2, back diffusion of ions was suppressed, leading to an increase in current efficiency. We also investigated the specific water transport by electroosmosis during the ED operation. We found that the amount of water transported increased proportionally to the concentration ratio of the concentrated and diluted solutions. When the concentration ratio exceeded 100, the specific water transport rapidly increased due to osmotic pressure, making it challenging to obtain a concentrated solution greater than 200 g/L.

Scale Formation in the Concentrate Compartment of an Electrodialysis Stack During Desalination of Brackish Water (염수의 탈염을 위한 전기투석 농축실에서의 스케일 형성)

  • Moon Seung-Hyeon;Yang Jung-Hoon;Yeon Kyeong-Ho
    • Membrane Journal
    • /
    • v.15 no.2
    • /
    • pp.175-186
    • /
    • 2005
  • An electrodialysis process was operated for a long period to investigate the scale formation on the membrane surface. During the desalination process, concentration of $Ca^{2+}$ and $SO_4^{2-}$ ions increased continuously in the concentrate compartment and eventually caused precipitation on the cation exchange membrane (Neosepta CMX) surface. During the initial scale formation, the performance of the process and membrane characteristics did not show significant changes, except the decrease in limiting current density of the CMX membrane occurring due to increase in the salt concentration in the concentrate compartment. Eventually, the limiting current density of the fouled CMX membrane dropped significantly to $300\;A/m^2$ as water dissociation occurred in the CMX membrane. It was concluded that the fouling was caused mainly by the scale formation on the cation exchange membrane surface in the concentrate and consequent water dissociation. Also the scale formation was reasonably predicted by the solubility of $CaSO_4$.

The development of high-performance PRO module and effects of operating condition on the performance of PRO module (고성능 PRO 모듈 개발 및 운전조건이 모듈 성능에 미치는 영향)

  • Han, Man Jae;Sim, Yeonju;Lee, Jong Hwa
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.303-310
    • /
    • 2017
  • Pressure retarded osmosis(PRO) has attracted much attention as potential technology to reduce the overall energy consumption for reverse osmosis(RO) desalination. The RO/PRO hybrid process is considered as the most logical next step for future desalination. The PRO process aims to harness the osmotic energy difference of two aqueous solutions separated by a semipermeable membrane. By using the concentrated water(RO brine) discharged from existing RO plants, the PRO process can effectively exploit a greater salinity gradient to reduce the energy cost of processing concentrated water. However, in order to use RO brine as the draw solution, PRO membrane must have high water flux and enough mechanical strength to withstand the high operational pressure. This study investigates the development of a thin film composite PRO membrane and spiral wound module for high power density. Also, the influence of membrane backing layer on the overall power density was studied using the characteristic factors of PRO membranes. Finally, the performance test of an 8-inch spiral wound module was carried out under various operating conditions(i.e. hydraulic pressure, flow rate, temperature). As the flow rate and temperature increased under the same hydraulic pressure, the PRO performance increased due to the growth of water permeability coefficient and osmotic pressure. For a high performance PRO system, in order to optimize the operating conditions, it is highly recommended that the flow pressure be minimized while the flow rate is maintained at a high level.

Development of the Pilot System for Radioactive Laundry Waste Treatment Using UV Photo-Oxidation Process and Reverse Osmosis Membrane

  • Park, Se-Moon;Park, Jong-Kil;Kim, Jong-Bin;Shin, Sang-Woon;Lee, Myung-Chan
    • Nuclear Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.506-511
    • /
    • 1999
  • The pilot system for radioactive liquid laundry waste was developed with treatment capacity, 1ton/hr and set up in the Yong Kwang unit #4. The system is composed of tank module, RO systems and a UV/$H_2O$$_2$photo-oxidation unit. The RO system consists of the BW unit (low-pressure RO for brackish water desalination) and the SW unit (high-pressure RO for seawater desalination). The BW unit possesses 4 RO membranes and it can reduce the feed water volume down to 1/10. This concentrated feed water can be reduced again up to 1/10 in its volume in the SW unit composed of 4 RO membranes. The UV/$H_2O$$_2$ photo-oxidation process unit was used for the detergent degradation. The operation of the pilot system was carried out and verified in its capability through the continuous operation and concentration operation using the actual liquid waste from the power plant. The design criteria and data for industrialization were yielded. The efficiency of the UV/$H_2O$$_2$ photo-oxidation process and the optimum operational procedure were evaluated. The decontamination factors for radioactive cobalt and cesium were measured. This on-site test showed the experimental result in the DF$\geq$300 and volume reduction factor$\geq$100.

  • PDF

Removal Characteristics of Boron and Humic Acid by Pre-blending Seawater and Brackish Water Using UF-SWRO Hybrid Process in Pilot-scale Plant for Desalination (UF-SWRO 혼합공정을 이용한 해수담수화 파일럿 플랜트에서의 해수와 기수의 블렌딩을 통한 보론 및 휴믹산 제거 특성)

  • Kim, Won-Kyu;Shin, Sung-Hoon;Lee, Haksu;Woo, Dal-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2016
  • Using UF-SWRO hybrid process, pre-blending tests of seawater and brackish water were performed to investigate the effects on removal of boron and humic acid (HA). Feedwater pre-blending was set based on TDS concentration from 15,000 mg/L to 27,000 mg/L and analyzed for boron removal characteristics. Also organics rejection at same TDS concentration range was investigated by injecting HA. Boron concentration appeared to be high as TDS concentration was high ranging from 76.60% to 83.27%, but boron concentration in final produced water was increased up to 0.69 mg/L from 0.48 mg/L. In cases of HA tests at 10 mg/L, 22,500 mg/L TDS appeared to be higher removal rate of 17.59% than a very poor result of 8.43% in 27,000 mg/L. But high HA removal rate of 57.14% was obtained in produced water with 22,500 mg/L TDS containing 10 mg/L of HA and 27,000 mg/L TDS yielded lower boron removal rate of 54.49%. Meanwhile it was found that a relatively high flux and recovery rate were obtained following process when feedwater was injected with HA. It is considered that most of fouling substances were eliminated by binding between HA and $Ca^{2+}$. Thus, when desalination using UF-SWRO with respect to boron and HA, TDS concentration is determined to be advantageous as lower.

Evaluation of FO membrane performance for each type of pre-treatment from WWTP secondary effluents (하수방류수의 전처리 조건별 FO막의 운전성능평가)

  • Jeong, Junwon;Kim, Jihoon;Kim, Geonyoub;Park, Junyoung;Kim, Hyungsoo;Kim, Hyungsook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.131-137
    • /
    • 2016
  • The development of alternative water resources has emerged as an effective method for solving drought of water resources due to extreme weather and increase in water consumption. Recently, in Korea, there has been active research on reverse osmosis desalination technology, wastewater reuse using forward osmosis membranes, and the forward osmosis(FO)-reverse osmosis(RO) hybrid process combining these two technologies. In this study, the basic performance of FO membranes manufactured by three domestic and international manufactures such as Microfilter Co., Ltd., Toray Chemical Korea Inc., and Hydration Technologies Inc., were investigated for wastewater reuse. In addition, as an experiment to select feed solution, the selected membranes were operated 48 consecutive hours using three secondary effluents pretreated by the UF membrane with a pore size of $0.1{\mu}m$ and auto strainer with pore sizes of $1{\mu}m$ and $100{\mu}m$ as feed solution. Although there was not much difference in the operating performance. Thus, the treated water using the $100{\mu}m$ auto strainer was selected as feed solution applied to the assessment.

Advanced Membrane Systems for Seawater Desalination. Kinetics of Salts Crystallization from RO Brines Promoted by Polymeric Membranes

  • Curcio, Efrem;Obaidani, Sulaiman Al;Macedonio, Francesca;Profio, Gianluca Di;Gualtieri, Silvia;Drioli, Enrico
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.93-98
    • /
    • 2007
  • The reliability of innovative membrane contactors technology (i.e. Gas/Liquid Membrane Contactors, Membrane Distillation/Crystallization) is today increasing for seawater desalination processes, where traditional pressure-driven membrane separation units are routinely operated. Furthermore, conventional membrane operations can be integrated with membrane contactors in order to promote possible improvements in process efficiency, operational stability, environmental impact, water quality and cost. Seawater is the most abundant aqueous solution on the earth: the amount of dissolved salts covers about 3% of its composition, and six elements (Na, Mg, Ca, K, Cl, S) account for more than 90% of ionic species. Recent investigations on Membrane Distillation-Crystallization have shown the possibility to achieve significant overall water recovery factors, to limit the brine disposal problem, and to recover valuable salts (i.e. calcium sulphate, sodium chloride, magnesium sulphate) by combining this technology with conventional RO trains. In this work, the kinetics of $CaSO_4{\cdot}2H_2O,\;NaCl\;and\;MgSO_4{\cdot}7H_2O$ crystallization is experimentally investigated in order to improve the design of the membrane-based crystallization unit.

Dynamic Economic Dispatch and Control of a Stand-alone Microgrid in DongAo Island

  • Ma, Yiwei;Yang, Ping;Guo, Hongxia;Wang, Yuewu
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1432-1440
    • /
    • 2015
  • A dynamic economic dispatch and control method is proposed to minimize the overall generating cost for a stand-alone microgrid in DongAo Island, which is integrated with wind turbine generator, solar PV, diesel generator, battery storage, the seawater desalination system and the conventional loads. A new dispatching strategy is presented based on the ranking of component generation costs and two different control modes, in which diesel generator and battery storage alternate to act as the master power source to follow system power fluctuation. The optimal models and GA-based optimization process are given to minimize the overall system generating cost subject to the corresponding constraints and the proposed dispatch strategy. The effectiveness of the proposed method is verified in the stand-alone microgrid in DongAo Island, and the results provide a feasible theoretical and technical basis for optimal energy management and operation control of stand-alone microgrid.