• 제목/요약/키워드: Depressurization Method

검색결과 31건 처리시간 0.03초

기존 단독주택의 침기량 산정법에 관한 연구 (A Study on the Calculation Method of Infiltration for Detached Houses)

  • 김길태;유정현;황하진;김경식
    • 설비공학논문집
    • /
    • 제25권9호
    • /
    • pp.493-498
    • /
    • 2013
  • The purpose of this study is to find the infiltration of detached houses, for energy consumption analyses. The pressurization and depressurization method is used to determine infiltration. Blower door tests are expressed in terms of ACH 50, which stands for the hourly air change rate at 50 Pa of fan pressure. The ACH 50 of existing Detached Houses ranges from 5 to 50. Air infiltration is related to construction year and accuracy, maintenance conditions, and so on. When estimating the infiltration of random detached houses, the year used can be the base value of the infiltration rate from 0.25 to 2.0 times/h. The maintenance conditions, construction accuracy and repair affect the air infiltration 0 to 0.5 times/h, 0 to 0.3 times/h, 0 to 1 times/h, respectively.

원자로 사고 또는 과도상태시 공기방출현상에 대한 연구 (Study of Air Clearing during Severe Transient of Nuclear Reactor Coolant System)

  • 배윤영;김환열;송철화;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.835-838
    • /
    • 2002
  • An experiment has been performed using a facility, which simulates the safety depressurization system (SDS) and in-containment refueling water storage tank (IRWST) of APR1400, an advanced PWR being developed in Korea, to investigate the dynamic load resulting from the blowdown of steam from a steam generator through a sparser. The influence of the key parameters, such as air mass, steam pressure, submergence, valve opening time, and pool temperature, on frequency and peak toads was investigated. The blowdown phenomenon was analyzed to find out the real cause of the initiation of bubble oscillation and discrepancy in frequencies between the experiment and calculation by conventional equation for bubble oscillation. The cause of significant damping was discussed and is presumed to be the highly tortuous flow path around bubble. The Rayleigh-Plesset equation, which is modified by introducing method of image, reasonably reproduces the bubble oscillation in a confined tank. Right after the completion of air discharge the steam discharge immediately follows and it condenses abruptly to provide low-pressure pocket. It may contribute to the negative maximum being greater than positive maximum. The subsequently discharging steam does not play as at the driving force anymore.

  • PDF

공동주택의 기밀성능 평가 및 에너지 절감효과 분석 (An Evaluation of Airtightness Performance and Analysis of Energy Savings Potential in Apartment Housing)

  • 이승복
    • 태양에너지
    • /
    • 제15권3호
    • /
    • pp.119-125
    • /
    • 1995
  • 지금까지 우리는 건물분야에서의 합리적인 에너지 사용을 위하여 건물외피의 단열성능을 향상시킴으로써 열손실을 줄이려는 데에 주력하여 왔으며, 침기로 인한 열손실을 줄이려는 노력은 상대적으로 미흡하였다. 그러나, 침기로 인한 난방에너지의 소비가 상당량에 이르는 것으로 조사됨으로써 재실형태에 따라 최소환기기준을 만족시키면서 침기에 의한 불필요한 에너지의 손실을 줄이려는 노력이 매우 유효한 것으로 평가되고 있다. 실제로 침기에 의한 불필요한 에너지의 낭비가 얼마나 되는가를 평가하기 위해서는, 건물에서의 침기율을 정확하게 측정할 수 있는 방법이 전제되어야 한다. 본 연구에서는 감압/가압법의 일종인 Blower Door System을 사용하여 공동주택에서의 기밀성능을 측정, 평가함은 물론 측정결과를 토대로 합리적인 수준까지 기밀화할 경우 난방에너지의 절약가능성에 대하여 추정하였다.

  • PDF

국내 비주거용 건물의 기밀성능 측정 결과를 통한 기밀 시공 가이드라인 개발 (Developing the Construction Guideline for ZEB Based on Air-tightness of Public Buildings in Korea)

  • 배민정;최경석
    • 토지주택연구
    • /
    • 제11권3호
    • /
    • pp.69-74
    • /
    • 2020
  • Since the design Standard for Energy Conservation in Building was implemented in 2008 for the first time, building elements such as window and door should satisfy the minimum criteria to apply for a building. Though its regulation does not cover the whole building yet, recent demand to reduce energy consumption in building sector grows rapidly year by year and also draws a lot of interest to ensure the whole building level. For example, a Zero energy building, one of low-energy buildings, requires a customized solution to resolve the air leakage issue to meet the standards in achieving the high level of air tightness. In this study, six non-residential buildings were tested by fan pressurization method to observe the air tightness of whole building to suggest the construction guideline for air tightness of low-energy building. Five out of six tested buildings showed 0.27 to 1.16 h-1 of number of air changes except one community center. These buildings were carefully constructed not only for building planning but also for parts where there was a concern of air leakage, thereby securing high levels of air-tightness. The construction skills were developed as a checklist to manage and supervise the construction site. It is our suggestion to use this checklist at construction sites for ZEB with the high level of air-tightness.

신한옥 침실 공간의 기밀성능 평가 연구 (A Study on the Airtightness Performance of New Han-ok Bedrooms)

  • 이주엽;장현충;이태강;송민정;김선우
    • KIEAE Journal
    • /
    • 제13권3호
    • /
    • pp.79-89
    • /
    • 2013
  • The purpose of this study is to evaluate the airtightness performance of New Han-ok and to supply fundamental data for standards establishment. Air leakage testings were accomplished by means of blower door test in 26 bedrooms of 16 Han-oks located in Jeonnam happy villages. Followings are results. 1) Air change per hour at 50 Pa(ACH50) is located on 8.42~78.38. 2) No correlation between ACH50 and volumes, floor area, above grade surface area. 3) The more wood structural elements are exposed, attached spaces, wooden sliding and casement windows, the less airtightness performance. 4) An Airtightness with ACH50/20(NL, Normalized leakage) is located on 0.42~3.92 and building leakage class following F(4%), G(11%, sufficiently leaky, No need mechanical ventilation), H(4%, Need of cost-effective tightening), I(31%), J(50%) by a single-story house the normalized leakage of ASHRAE.

Vacuum Strand Burner를 이용한 혼합형 고체 추진제의 저압 연소특성 연구 (A Study on the Combustion Characteristics of Composite Solid Propellants at Low Pressure using Vacuum Strand Burner)

  • 박영규;유지창;김인철;이태호
    • 한국추진공학회지
    • /
    • 제3권1호
    • /
    • pp.95-103
    • /
    • 1999
  • 혼합형 고체추진제의 저압하에서의 연소특성을 연소속도측정, 점화 및 정상 연소현상 관찰, 그리고, 소화표면의 구조 관찰의 측면에서 연구하였다. 이를 위하여 OVSB 장치를 제작하였으며, 저압 연소속도 측정기법을 정립하여 혼합형 고체추진제의 저압 연소속도를 측정하였고, OVSB의 연소실에 장착된 창을 통하여 추진제의 점화 및 연소현상을 비디오 카메라를 사용하여 초당 30 장의 속도로 촬영하여 분석하였다. 또한, 급속감압법을 이용하여 얻은 추진제의 소화표면의 구조를 주사전자현미경으로 분석하였다. 시험 대상 추진제들은 대기압 이하(2.0∼15psia)의 저압하에서 압력 지수가 0.6∼0.88로 높은 압력의존성을 보였으며, 추진제에 포함된 금속입자(Al) 함량이 연소속도와 압력 지수에 크게 영향을 주는 것으로 나타났다. 금속함량이 클수록 연소속도가 빨랐으며, 압력 지수는 작았다. 시험대상 추진제들은 2.0psia 부근에서 자체 소화되는 특성을 보였다. 그리고, 연소표면에서의 AP 입자의 분해속도가 바인더의 분해속도 보다 느렸으며, 낮은 압력으로 인해 바인더가 쉽게 기체상태로 승화하는 것으로 판단되었다. Al이 다량 함유된(17.5%) 추진제가 점화성이 우수하였다.

  • PDF

회분식 반응기에서 반응폭주에 의한 2-Phase 흐름 파열판 설계 및 적용에 관한 연구 (A Study on the Rupture Disk Design and Application at the Two Phase Flow by Runaway Reaction at Batch Reactor)

  • 이형섭;윤희창
    • 한국가스학회지
    • /
    • 제21권3호
    • /
    • pp.1-8
    • /
    • 2017
  • 이 연구의 목적은 회분식 반응기에서 반응폭주에 의하여 2상(기상-액상)에서 적용가능한 파열판의 크기를 설계하는 방안을 제시하는 것이다. 반응폭주의 정의는 제어가 되지 않은 냉각수 투입불가 또는 운전조건의 이탈에 의한 비정상적으로 발열반응을 말한다. 이 결과로 반응기의 온도는 급격히 증가하게 된다. 반응폭주의 원인은 크게 자기과열반응과 지연반응으로 구분한다. 일반적인 안전밸브나 파열판의 내경 크기로는 폭주반응시에는 적절하게 압력을 해소할 수 없다. 폭주반응 시 반응온도 및 압력이 급격하게 증가하기 때문에 안전밸브로 분출되는 내용물은 2상이다. 이 연구에서는 최근 회분식 반응기의 폭주반응으로 인하여 사고사례의 원인을 분석하고, 2 상으로 분출현상 및 특징을 설정하고, 이에 적절한 파열판의 크기를 설계하여 적용하는 방안을 제시하고자 한다.

격납용기 성능해석을 위한 영향도에 관한 연구 (A Study on the Influence Diagrams for the Application to Containment Performance Analysis)

  • Park, Joon-Won;Jae, Moon-Sung;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.129-136
    • /
    • 1996
  • 영향도를 이용하여 영광 3, 4호기의 격납용기 성능해석을 수행하였다. 기존의 사상수목기법을 응용한 격납용기 성능해석은 사건들 사이의 의존 관계를 명확히 나타내기 어렵고, 사고진행사상수목(APET) 에서 알 수 있듯이, 격납용기와 같은 복잡한 계통에 적용할 경우 그 의존 관계를 그림으로조차 나타낼 수가 없으며, 또한, 의사결정문제를 다루는 데에도 많은 한계점을 지니고 있다. 이러한 문제점들을 해결하기 위하여 새로이 개발된 방법론인 영향도를 영광 3, 4호기 격납용기 성능해석과 사고관리방안을 평가하는 데에 적용하여 보았다. 본 연구에서 얻은 계산 결과와 기존의 사상수목 기법을 이용하여 계산한 결과와 비교한 결과, 거의 일치하는 계산 결과를 얻을 수 있으면서도 전체 격납용기 계통을 한 눈에 알기 쉽게 그림으로 나타낼 수 있었다. 또한, 향도가 의사결정문제를 일반적으로 다룰 수 있음을 보이기 위하여 본 방법론을 사고관리방안을 평가하는 데에 이용하여, 원자로 냉각계통 감압과 원자로공동 범람 방안, 두 가지 사고관리방안을 평가하여 보았다. 모두 초기 격납용기 파손에는 나쁜 영향을 주는 것으로 나 타났으나, 후기 격납용기 파손이나 중기발생기 세관파손에는 원자로공동범람과 일차계통 감압이 각각 어느 정도 긍정적인 영향을 미치는 것으로 나타났다. 본 연구를 통하여, 영향도를 이용한 격납응기 성능 해석은 사상수목기법을 이용한 분석에 비해, 진행되는 사건들 사이의 의존관계를 보다 명확히 나타낼 수 있고, 또한 영향도는 운전자의 의사결정을 잘 나타낼 수 있으므로 사고관리기법을 평가하는 데에도 쉽게 적용할 수 있음을 알 수 있다. 결론적으로, 본 연구에서는 영향도가 사상수목기법이 지니고 있는 여러 한계점들을 쉽게 극복하며 격납용기 성능해석에 적용할 수 있음을 보였다.

  • PDF

타원형 날개에 대한 공동소음 예측 연구 (Study on Cavitation Noise Predictions for an Elliptic Wing)

  • 정승진;홍석윤;송지훈;권현웅;박일룡;설한신;김민재
    • 해양환경안전학회지
    • /
    • 제25권6호
    • /
    • pp.757-764
    • /
    • 2019
  • 수중에서 빠른 속도로 운동하는 물체 주변에서 감압이 발생하며, 이로 인해 공동 핵이 팽창함으로써 캐비테이션이 발생한다. 캐비테이션이 발생하게 되면 소음 및 진동이 증가하며, 추진기의 경우 추진 성능이 저해되는 악영향을 초래하기 때문에 이에 대한 예측이 필요하다. 본 연구에서는, 캐비테이션 발생으로 인한 공동소음의 해석절차를 정립하고, 타원형 날개에 적용하였다. 먼저 전산유체역학해석을 수행하여, 날개 형상 주위 유동장 정보를 도출하였다. 공동 핵 밀도 함수를 활용하여, 핵의 초기 반경 별로 개수를 계산하였고 이들을 압력 강하가 큰 날개 끝 전류에 랜덤하게 배치하였다. 이후 공동소음 해석을 위해 각각의 핵에 대하여 Lagrangian 관점에서 버블 다이나믹스를 활용하였고, 계산된 공동의 거동으로부터 소음해석을 수행하였다. 공동소음은 광대역 소음의 특성을 가지는 것을 확인하였으며, 최종적으로 선박해양플랜트연구소(KRISO)의 대형캐비테이션터널(LCT)에서 수행된 실험 계측결과와의 비교를 통해 검증을 수행하였다.

혐기성 소화의 후처리로서 분리막의 여과특성 연구 (Characteristics of Membrane Filtration as a Post Treatment to Anaerobic Digestion)

  • 추광호;이정학;백운화;고의찬;김상원;고종호
    • 공업화학
    • /
    • 제3권4호
    • /
    • pp.730-738
    • /
    • 1992
  • 혐기성 소화액의 한외여과에 의한 후처리에서 분리막의 재질에 따른 여과특성을 연구하였다. 상이한 분리막의 여과특성을 정량적으로 평가하기 위해 저항 모델을 이용하였다. 소화액에 대한 플럭스의 양태는 초기의 물에 대한 분리막의 투과도에 무관하게 나타났다. 플루오로 폴리머 막의 경우에 유속의 증가에 따라 큰 플럭스의 향상을 보였는데 이것은 다른 분리막에 비해 막표면에 형성된 케이크층의부착성이 약해 쉽게 제거될 수 있음을 시사해준다. 장시간 운전에서 플럭스의 감소는 오염층 저항의 증가에서 뿐만아니라 분극층 저항의 증가에서도 기인되었는데, 이와같은 계속적인 분극층 저항의 증가는 미생물의 분해 및 성장에 따른 케이크층 내의 성상변화를 반영할 수 있다. 막표면이 친수성인 셀룰로오즈 막은 소수성인 폴리술폰 막에 비해 낮은 막오염도를 보여주었다. 감압을 통해 플럭스를 $5-10L/m^2/h$회복시킬 수 있었다. 세척단계에서 여과저항을 평가함으로써 15분의 단시간내에 세척이 완료됨을 알 수 있었다.

  • PDF