• Title/Summary/Keyword: Department of Radiological Science

Search Result 2,510, Processing Time 0.031 seconds

Review Study on the Measurement Tools of Scoliosis: Mainly on Non-radiological Methods (척추측만증 평가 척도에 관한 문헌 고찰: 비방사선 방법을 중심으로)

  • Kim, Dong-Joo;Choi, Seong-Kyeong;Jo, Hyo-Rim;Ha, Yu-bin;Choi, Sung-Hwan;Park, Seo-Hyun;Lee, Seung Deok;Keum, Dong-Ho;Sung, Won-Suk;Kim, Eun-Jung
    • The Journal of Korean Medicine
    • /
    • v.42 no.1
    • /
    • pp.75-98
    • /
    • 2021
  • Objectives: The purpose of this study is to investigate the characteristics, validity, and reliability of non-radiological assessment tools of scoliosis that have been studied so far. Methods: Electronic databases including Pubmed, Cochrane Library, CNKI, Science On, RISS, OASIS were searched by keywords including 'scoliosis assessment', 'scoliosis screening', 'physical examination', 'functional measurement', 'photography', and 'smartphone'. Results: 32 articles using radiation-free assessments were identified from 1,011 records. The mostly used non-radiological methods were Surface topography, Scoliometer, Ultrasound, Digital Infrared Thermal Imaging, and Photography. The other methods were Gait analysis, 3D depth sensor imaging, and Low intensity electromagnetic scan. Conclusions: It was found that non-radiological assessment tools might reduce the number of radiographs taken in scoliosis patients. To increase the reliability and validity, further research on the measurement tools of scoliosis will be needed.

A feasibility study of using a 3D-printed tumor model scintillator to verify the energy absorbed to a tumor

  • Kim, Tae Hoon;Lee, Sangmin;Kim, Dong Geon;Jeong, Jae Young;Yang, Hye Jeong;Schaarschmidt, Thomas;Choi, Sang Hyoun;Cho, Gyu-Seok;Kim, Yong Kyun;Chung, Hyun-Tai
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3018-3025
    • /
    • 2021
  • The authors developed a volumetric dosimetry detector system using in-house 3D-printable plastic scintillator resins. Three tumor model scintillators (TMSs) were developed using magnetic resonance images of a tumor. The detector system consisted of a TMS, an optical fiber, a photomultiplier tube, and an electrometer. The background signal, including the Cherenkov lights generated in the optical fiber, was subtracted from the output signal. The system showed 2.1% instability when the TMS was reassembled. The system efficiencies in collecting lights for a given absorbed energy were determined by calibration at a secondary standard dosimetry laboratory (kSSDL) or by calibration using Monte Carlo simulations (ksim). The TMSs were irradiated in a Gamma Knife® IconTM (Elekta AB, Stockholm, Sweden) following a treatment plan. The energies absorbed to the TMSs were measured and compared with a calculated value. While the measured energy determined with kSSDL was (5.84 ± 3.56) % lower than the calculated value, the energy with ksim was (2.00 ± 0.76) % higher. Although the TMS detector system worked reasonably well in measuring the absorbed energy to a tumor, further improvements in the calibration procedure and system stability are needed for the system to be accepted as a quality assurance tool.

Radioprotection of Alliin in Oogenesis Cells of a White Rat (흰쥐 난자형성 세포의 알리인 방어효과)

  • JI, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.471-478
    • /
    • 2018
  • Oogenesis process of ovary produces a lot of undifferentiated cells. Especially, the radiation exposure of early immature cells in the process of growth to oocyte causes serious disabilities. This study examined the radiation damage mechanism of undifferentiated cells and organelles in oogenesis process, and the radioprotection after injection of alliin. The ultrastructure after 7Gy X-ray irradiation on the white rat was observed in the experiment. The results is as follows. It was observed that the nucleus membrane of an oogonium was damaged and vacuolated in the several parts after 15 days of irradiation. The damage of mitochondria membrane and flow in cytoplasm after 20 and 30 days was found in the oogonium. After 40 days observation, peroxidation of fat droplets was found and organelles were tangled each other in ovary tissue. The partial damage of nuclear membrane in oogonium past 15 days after injection of alliin was found, but decreased remarkably. Mitochondria, Golgi body, and rough endoplasmic reticulum were also clearly observed, therefore, radioprotection effects in alliin was confirmed partially.

Similarity analysis of pixelated CdTe semiconductor gamma camera image using a quadrant bar phantom for nuclear medicine: Monte Carlo simulation study

  • Park, Chan Rok;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1947-1954
    • /
    • 2021
  • In the nuclear medicine imaging, quality control (QC) process using quadrant bar phantom is fundamental aspect of evaluating the spatial resolution. In addition, QC process of gamma camera is performed by daily or weekly. Recently, Monte Carlo simulation using the Geant4 application for tomographic emission (GATE) is widely applied in the pre-clinical nuclear medicine field for modeling gamma cameras with pixelated cadmium telluride (CdTe) semiconductor detector. In this study, we modeled a pixelated CdTe semiconductor detector and quadrant bar phantom (0.5, 1.0, 1.5, and 2.0 mm bar thicknesses) using the GATE tool. Similarity analysis based on correlation coefficients and peak signal-to-noise ratios was performed to compare image qualities for various source to collimator distances (0, 2, 4, 6, and 8 cm) and collimator lengths (0.2, 0.4, 0.6, 0.8, and 1.0 cm). To this end, we selected reference images based on collimator length and source to collimator distance settings. The results demonstrate that as the collimator length increases and the source to collimator distance decreases, the similarity to reference images improves. Therefore, our simulation results represent valuable information for the modeling of CdTe-based semiconductor gamma imaging systems and QC phantoms in the field of nuclear medicine.

The Study on the Attenuation of X-ray and Imaging Quality by Contents in Stomach (위장내 음식물에 따른 방사선 감약 및 화질에 관한 연구)

  • Dong, Kyung-Rae;Ji, Youn-Sang;Kim, Chang-Bok;Choi, Seong-Kwan;Moon, Sang-In;Dieter, Kevin
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.53-60
    • /
    • 2009
  • This study examined the change in the attenuation of X-rays with the ROI (Region of Interest) in DR (Digital Radiography) according to the stomach contents by manufacturing a tissue equivalent material phantom to simulate real stomach tissue based on the assumption that there is some attenuation of X-rays and a difference in imaging quality according to the stomach contents. The transit dosage by the attenuation of X-rays decreased with increasing protein thickness, which altered the average ROI values in the film and DR images. A comparison of the change in average ROI values of the film and DR image showed that the image in film caused larger density changes with varying thickness of protein than the image by DR. The results indicate that NPO (nothing by mouth) is more important in film system than in DR system.

  • PDF

Development and Usefulness Evaluation of Simulator for Educational Radiation Generator (방사선발생장치 교육을 위한 시뮬레이터의 개발과 유용성 평가)

  • Seo, Jeong-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.591-597
    • /
    • 2021
  • In the present study, we developed virtual reality education contents for radiation generator on radiation education field. The radiation generator was divided by module and even the X-ray exposure part was manufactured in detail for designing 3D models. The mechanical details of the X-ray exposure part, the function of adjusting field size of the X-ray, the function of moving the exposure part, and the demonstrating the principle of the X-ray tube were applied. For developing VR contents, the Unreal Engine was used. To evaluate the usefulness of virtual reality content, we used t-test by SPSS. The group used the simulator showed significantly higher levels of understanding of X-ray generation, X-ray irradiation unit composition, irradiation field size adjustment, irradiation unit position adjustment, and overall composition and function. We believe that this VR contents will be used well with radiation safe environment.

Reduction of Exposure Dose of Mammography by Comparison of Compression Paddle Material (압박대 재질 비교를 통한 유방촬영의 피폭선량 감소 방안)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.455-460
    • /
    • 2019
  • This study compared the radiation transmission and image quality of polymethylmethacrylate (PMMA), polycarbonate (PC), and carbon, which are common components of the compression plates currently used during breast imaging. In addition to measuring the transmitted dose and the intensity without the use of a compression paddle, the four different compression paddles were evaluated according to the material and thickness of each paddle. Radiation transmittance, maximum intensity, and plot profile type w ere all evaluated for each material, and for each factor evaluated the follow ing order w as noted, from best to w orst: carbon 4 mm, PMMA 3 mm, PMMA 4 mm, and PC 4 mm. It is necessary to study a variety of materials and thicknesses in order to find the optimal combination of material and thickness, because not only does the material have a large influence in reducing the radiation exposure during mammography, but the thickness of the compression plate also has a great influence.

Prediction of Delivery Quality Assurance Via Machine Learning in Helical Tomotherapy (방사선치료 시 다양한 기계학습을 이용한 선량품질관리 결과의 예측)

  • Kyung Hwan Chang
    • Journal of radiological science and technology
    • /
    • v.47 no.4
    • /
    • pp.263-270
    • /
    • 2024
  • The objective of this study was to evaluate the accuracy and impact of leaf open time (LOT) and pitch using various machine learning models on EBT film-based delivery quality assurance (DQA) performed on 211 patients of helical tomotherapy (HT). We randomly selected passed (n=191) and failed (n=20) DQA measurements to evaluate the accuracy of the k-nearest neighbor (KNN), support vector machine (SVM), naive Bayes (NB) and logistic regression (LR) models using scale-dependent metrics such as the coefficient of determination (R2), mean squared error (MSE), and root MSE (RMSE). We evaluated the performance of the four prediction models in terms of the accuracy, precision, sensitivity, and F1-score using a confusion matrix, finding the NB and LR models to achieve optimal results. The results of this study are expected to reduce the workload of medical physicists and dosimetrists by predicting DQA results according to LOT and pitch in advance.

A Study of Radiation Dose Evaluation and Optimization Methods for Intra Oral Dental X-ray in Pediatric Patient (소아 구내촬영 시 방사선량 평가 및 최적화 방안에 대한 연구)

  • Lee, Hyun-Yong;Cho, Yong-In
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.195-203
    • /
    • 2021
  • Although intra oral dental x-ray is a lower dose than other radiological examinations, pediatric patients are known to have a higher risk of radiation damage than adults. For this reason, pediatric dental x-ray requires management of dose evaluation and imaging conditions during the examination. In this study, the dose calculation program ALARA-Dental(child/adult) was used to evaluate the organ dose and effective dose exposed to each examination site during intra oral imaging of children during dental radiographic examination, and dose analysis according to the imaging conditions was performed. As a result, the highest organ dose distribution was shown at 0.044 ~ 0.097 mGy in all are as of the mucous membrane of oral cavity except for the maxillary incisors and canines. Also, in the case of the thyroid gland, the maxillary canine and maxillary premolar examination showed 0.027 and 0.020 mGy, respectively, and the dose distribution was 15.4% to 70.0% higher than that of the mandibular examination. As for the effective dose calculated during intra oral imaging, the maxillary anterior and canine examinations showed the highest effective doses of 0.005 and 0.004 mSv, respectively, and the maxillary area examination showed a higher dose distribution on average than the mandible.