• Title/Summary/Keyword: Department of Radiological Science

Search Result 2,510, Processing Time 0.027 seconds

Evaluation of Radiation Doses of Dental Portable Equipment (치과용 이동형 방사선장치의 선량평가)

  • Park, Hoon-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.445-450
    • /
    • 2018
  • We aim to evaluate safety of radiation by measuring leakage dose and patient(phantom) incident dose of ZEN-PX II dental portable equipment developed by G company. Measurement for leakage dose of equipment is conducted on the top, at the bottom, on the left, on the right and at the back. Dose measurement incident on the subject with the area dosimeter when using the phantom and measurement the leakage dose of equipment when using the phantom are evaluated. Comparing the right with the highest leakage dose as a 0 cm, 25 cm, 50 cm, 75 cm and 100 cm dose measurement at the measurement height of 100 cm, 64.2 uR was reduced to 47.3 uR in the senser mode 0.32sec. Even in film mode it was measured at 414.4 uR and about 27% lower at 162.6 uR. As the result of this study, when the irradiation time is 2 sec the right side dose is 290.5 uR and sensor mode is 0.32 sec the right side dose is 64.2 uR.

Predictive of Osteoporosis by Tree-based Machine Learning Model in Post-menopause Woman (폐경 여성에서 트리기반 머신러닝 모델로부터 골다공증 예측)

  • Lee, In-Ja;Lee, Junho
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.495-502
    • /
    • 2020
  • In this study, the prevalence of osteoporosis was predicted based on 10 independent variables such as age, weight, and alcohol consumption and 4 tree-based machine-learning models, and the performance of each model was compared. Also the model with the highest performance was used to check the performance by clearing the independent variable, and Area Under Curve(ACU) was utilized to evaluate the performance of the model. The ACU for each model was Decision tree 0.663, Random forest 0.704, GBM 0.702, and XGBoost 0.710 and the importance of the variable was shown in the order of age, weight, and family history. As a result of using XGBoost, the highest performance model and clearing independent variables, the ACU shows the best performance of 0.750 with 7 independent variables. This data suggests that this method be applied to predict osteoporosis, but also other various diseases. In addition, it is expected to be used as basic data for big data research in the health care field.

Evaluation and Comparison of Signal to Noise Ratio According to Histogram Equalization of Heart Shadow on Chest Image (흉부영상에서 평활화 시 심장저부 음영의 신호 대 잡음비 비교평가)

  • Kim, Ki-Won;Lee, Eul-Kyu;Jeong, Hoi-Woun;Son, Jin-Hyun;Kang, Byung-Sam;Kim, Hyun-Soo;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.197-203
    • /
    • 2017
  • The purpose of this study was to measure signal to noise ratio (SNR) according to change of equalization from region of interest (ROI) of heart shadow in chest image. We examined images of chest image of 87 patients in a University-affiliated hospital, Seoul, Korea. Chest images of each patient were calculated by using ImageJ. We have analysis socio-demographical variables, SNR according to images, 95% confidence according to SNR of difference in a mean of SNR. Differences of SNR among change of equalization were tested by SPSS Statistics21 ANOVA test for there was statistical significance 95%(p < 0.05). In SNR results, with the quality of distributions in the order of original chest image, original chest image heart shadow and equalization chest image, equalization chest image heart shadow(p < 0.001). In conclusion, this study would be that quantitative evaluation of heart shadow on chest image can be used as an adjunct to the histogram equalization chest image.

A Survey Study on Face-to-face & Non-face-to-face Classes for Students Majoring in Radiology (방사선전공 학생들을 대상으로 면대면 & 비대면 수업에 관한 설문조사 연구)

  • Son, Jin-Hyun;Kim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.511-518
    • /
    • 2020
  • In the pandemic situation due to corona 19, we examined the satisfactory level of students' between non-face-to-face and online classes in the first year of radiology. In the case of online non-face classes related to radiation majors, it is considered better to conduct real-time lectures than recorded lectures, which allows students to understand difficult radiation majors throughout real-time questions and answers, and at the same time allows them to sympathize with difficult subjects such as intimacy and bonds between students. As a result of the analysis of the answers to questionnaires, the coefficient of answer correlation between first and second grade students is P>0.05, and there is no answer correlation between grades, and it can be seen that the higher the grade, the higher the demand for face-to-face classes was.

Development and Usefulness Evaluation of Virtual Reality Simulator for Education of Spatial Dose Rate in Radiation Controlled Area (방사선관리구역의 공간선량률 교육을 위한 가상현실 시뮬레이터의 개발과 유용성 평가)

  • Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.493-499
    • /
    • 2023
  • This study developed education contents of measuring spatial dose with virtual reality simulation and applied to students majoring radiological science. The virtual reality(VR) contents with measuring spatial dose rate in the radiation controlled area was developed based on the simulation from pilot study. In this simulation, the tube voltage and tube current can be set from 60 to 120 kVp in 10 kVp steps and 10 to 40 mAs in 10 mAs increments, and the distance from source can be set from 30 to 400 cm continuously. Iron and lead shields can be placed between the source and the detector, and shielding thickness can be set by 1 mm increments ranging from 1 to 20 mm. We surveyed to students for evaluating improvement of understanding spatial dose rate between before and after education by VR simulation. The survey was conducted with 5 questions(X-ray exposure factors, effects by distance from the source, effects from using shield, depending on material and thickness of shield, concept and measuring of spatial dose rate) and all answers showed significant improvement. Therefore, this VR simulation content will be well used in education for spatial dose rate and radiation safety environments.

Craniopharyngiomas : Radiological Differentiation of Two Types

  • Lee, In Ho;Zan, Elcin;Bell, W. Robert;Burger, Peter C.;Sung, Heejong;Yousem, David M.
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.5
    • /
    • pp.466-470
    • /
    • 2016
  • Objective : To determine imaging features that may separate adamantinomatous and papillary variants of craniopharyngiomas given that tumors with adamantinomatous signature features are associated with higher recurrence rates, morbidity, and mortality. We specifically reviewed calcification on CT, T1 bright signal intensity, and cystic change on T2 weighted images for differentiating these two types. Methods : We retrospectively reviewed the MRI and CT studies in 38 consecutive patients with pathologically proven craniopharyngiomas between January 2004 and February 2014 for the presence of calcification on CT scans, bright signal intensity on T1 weighted images, and cystic change on T2 weighted images. Results : Of the 38 craniopharyngiomas, 30 were adamantinomatous type and 8 were papillary type. On CT scans, calcification was present in 25 of 38 tumors. All calcified tumors were adamantinomatous type. Twenty four of 38 tumors had bright signal intensity on T1 weighted images. Of these 24 tumors, 22 (91.7%) were adamantinomatous and 2 were papillary type. Cystic change on T2 weighted images was noted in 37 of 38 tumors; only 1 tumor with papillary type did not show cystic change. Conclusion : T1 bright signal intensity and calcification on CT scans uniformly favor the adamantinomatous type over papillary type of craniopharyngioma in children. However, these findings are more variable in adults where calcification and T1 bright signal intensity occur in 70.6% and 58.8% respectively of adult adamantinomatous types of craniopharyngiomas.

Evaluation of the Resolution Characteristics by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 해상력 특성 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Han, Ji-Hyun;Lee, Si-Nae;Kim, Min-Ji;Kim, Seung-Chul
    • Journal of radiological science and technology
    • /
    • v.45 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • This study was purpose to quantitative assessment of the resolution characteristics by using American college of radiology(ACR) phantom for magnetic resonance imaging (MRI). The MRI equipment was used (Achiva 3.0T MRI, Philips system, Netherlands) and the head/neck matrix shim SENSE head coil were 32 channels(elements) receive MR coil. And the MRI equipment was used (Discovery MR 750, 3.0T MRI, GE medical system, America) and the head/neck matrix shim MC 3003G-32R 32-CH head coil were receive MR coil. As for the modulation transfer function(MTF) comparison result by using ACR magnetic resonance imaging phantom, the MTF value of the ACR standard T2 image in GE equipment is 0.199 when the frequency is 1.0 mm-1 and the MTF value of the hospital T2 image in Philips equipment is 0.528. It was used efficiently by using a general sequence more than the standard sequence method using the ACR phantom. In addition it is significant that the quantitative quality assurance evaluation method for resolution characteristics was applied mutatis mutandis, and the result values of the physical image characteristics of the 3.0T MRI device were presented.

Experimental Study with Respect to Dose Characteristic of Glass Dosimeter for Low-Energy by Using Internal Detector of Piranha 657 (Piranha 657의 Internal Detector를 이용한 저에너지에서 유리선량계의 선량 특성에 관한 연구)

  • Son, Jin-Hyun;Min, Jung-Whan;Kim, Hyun-Soo;Lyu, Kwang-Yeul;Lim, Hyun-Soo;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.119-124
    • /
    • 2012
  • Recently, Glass Dosimeter (GD) with thermoluminescent Dosimeter (TLD) are comprehensively used to measure absorbed dose from diagnostic field to therapy field that means from low energy field to high energy field. However, such studies about dose characteristics of GD, such as reproducibility and energy dependency, are mostly results in high energy field. Because characteristic study for measurement devices of radiation dose and radiation detector is performed using 137Cs and 60Co which emit high energy radiations. Thus, this study was evaluated the linearity according to Piranha dose which measured by changing tube voltage (50kV, 80kV and 100kV which are low energy radiations), reproducibility and reproducibility according to delay time using GD. Measurement of radiation dose is performed using internal detector of Piranha 657 which is multi-function QA device (RTI Electronic, Sweden). Condition of measurement was 25mA, 0.02sec, 2.5mAs, SSD of 100 cm and exposure area with $10{\times}10cm^2$. As above method, GD was exposed to radiation. Sixty GDs were divided into three groups (50kV, 80kV, 100kV), then measured. In this study, GD was indicated the linearity in low energy field as high energy existing reported results. The reproducibility and reproducibility according to delay time were acceptable. In this study, we could know that GD can be used to not only measure the high energy field but also low energy field.

Feasibility of the Threshold-Based Quantification of Myocardial Fibrosis on Cardiac CT as a Prognostic Marker in Nonischemic Dilated Cardiomyopathy

  • Na Young Kim;Dong Jin Im;Yoo Jin Hong;Byoung Wook Choi;Seok-Min Kang;Jong-Chan Youn;Hye-Jeong Lee
    • Korean Journal of Radiology
    • /
    • v.25 no.6
    • /
    • pp.540-549
    • /
    • 2024
  • Objective: This study investigated the feasibility and prognostic relevance of threshold-based quantification of myocardial delayed enhancement (MDE) on CT in patients with nonischemic dilated cardiomyopathy (NIDCM). Materials and Methods: Forty-three patients with NIDCM (59.3 ± 17.1 years; 21 male) were included in the study and underwent cardiac CT and MRI. MDE was quantified manually and with a threshold-based quantification method using cutoffs of 2, 3, and 4 standard deviations (SDs) on three sets of CT images (100 kVp, 120 kVp, and 70 keV). Interobserver agreement in MDE quantification was assessed using the intraclass correlation coefficient (ICC). Agreement between CT and MRI was evaluated using the Bland-Altman method and the concordance correlation coefficient (CCC). Patients were followed up for the subsequent occurrence of the primary composite outcome, including cardiac death, heart transplantation, heart failure hospitalization, or appropriate use of an implantable cardioverter-defibrillator. The Kaplan-Meier method was used to estimate event-free survival according to MDE levels. Results: Late gadolinium enhancement (LGE) was observed in 29 patients (67%, 29/43), and the mean LGE found with the 5-SD threshold was 4.1% ± 3.6%. The 4-SD threshold on 70-keV CT showed excellent interobserver agreement (ICC = 0.810) and the highest concordance with MRI (CCC = 0.803). This method also yielded the smallest bias with the narrowest range of 95% limits of agreement compared to MRI (bias, -0.119%; 95% limits of agreement, -4.216% to 3.978%). During a median follow-up of 1625 days (interquartile range, 712-1430 days), 10 patients (23%, 10/43) experienced the primary composite outcome. Event-free survival significantly differed between risk subgroups divided by the optimal MDE cutoff of 4.3% (log-rank P = 0.005). Conclusion: The 4-SD threshold on 70-keV monochromatic CT yielded results comparable to those of MRI for quantifying MDE as a marker of myocardial fibrosis, which showed prognostic value in patients with NIDCM.

The Analysis of Regional Stressor Level on Personal Factor and Reaction According of Radiological Technologist (방사선사의 개인요인과 반응에 따른 지역별 스트레스원 수준 분석)

  • Jung Hong-Ryang;Son Bu-Soon;Lim Cheong-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.266-279
    • /
    • 2005
  • The present study was conducted to analyze the causes of stress on the part of Korean radiological technologists depending on their working environments. For this purpose, 890 questionnaires were distributed to and collected from radiological technologists who were working at 44 general hospitals in 16 cities and provinces of Korea during the period from the mid July to the end of August 2003. The collected data were compared between regions, divided into the capital, metropolitan, medium and small cities, whose results are as follows: 1. As factors affecting working conditions, drinking was found to exert more influence on radiological technologists in small- and medium-sized cities, while loyalty to immediate seniors and organizations was the one producing greater influence on them in metropolitan cities than other cities. Overall, position, job satisfaction and physical condition seemed to have a great effect on them (p<0.001).2. In terms of factors related to their roles, job satisfaction and physical condition played in general a greater role for radiological technologists (p<0.001). Immediate seniors and behavioral conducts were also found to have a lot influence on them (p<0.01).3. As for job conflicts, the kind of medical institutions seemed to exercise a great deal of impact on radiological technologists (p<0.05), while colleagues, immediate seniors, job satisfaction and physical conditions also produced a lot of influence on them as a whole (p<0.001).4. Regarding job autonomy, radiological technologists were found to have been less influenced by position in metropolitan cities and by immediate seniors in the capital city (p<0.01). As a whole, however, age and job satisfaction acted as decisive factors of influence on them (p<0.001). 5. Among factors related to job burden, gender played a bigger role for radiological technologists in metropolitan cities as the kind of medical institutions did in small- and medium-sized cities. Centrally, job satisfaction and behavioral conducts exercised a great impact on them (p<0.001).6. Job stability seemed to be more immensely linked to gender and physical conditions in metropolitan cities whereas position did more in the capital city. In general, how ever, job satisfaction produced a far-reaching (p<0.001).