• 제목/요약/키워드: Denture adhesive

검색결과 33건 처리시간 0.025초

수분함량에 따른 의치접착제의 확장성 관찰 (Spreadability observation of the denture adhesive by the amount of the water)

  • 김종문;최성민
    • 대한치과기공학회지
    • /
    • 제37권1호
    • /
    • pp.17-21
    • /
    • 2015
  • Purpose: In this study, Spreadability of denture adhesive in accordance with the saturation level of saliva, respectively, by using the resin plate and the glass was measured thickness and Spreadability. Methods: Examine the spreadability of denture adhesive in accordance with the saturation level of saliva, respectively, by using the resin plate and the glass was measured thickness and Spreadability. Also, by measuring the adhesive strength according to the amount of saliva, and the edentulous patients using denture adhesive and dry mouth patients attempt to provide clinical information of the denture adhesive. Therefore, by using the relatively low shrinkage cold curing resin, after fabricating specimen of plate form, for 7 days, it was immersed in water. Results: For the control group only denture adhesive, an artificial saliva for the experimental group were injected in $0.1m{\ell}$, $0.2m{\ell}$ and $0.3m{\ell}$ of the denture adhesive on the surface, experimental results of the investigation of the 10 times the tensile bond strength of the specimens in each group was obtained the following results. Conclusion: As the time to pressure increase in the same amount of saliva was found that the amount coming out of the denture adhesive, as the amount of saliva in the same pressure increase coming out of many denture adhesives. And the greater the pressure came out a lot of denture adhesives. Spreadability in measuring saliva contact with $0.1m{\ell}$ and $2m{\ell}$ and $3m{\ell}$ group pressured the diameter of the circular was the denture adhesive is small when compared to the group without adding the pressure of 2kg and 3kg put the saliva. The size of the circle is the same amount of saliva denture adhesive spread more pressure showed a greater increase.

An investigation into the effect of denture adhesives on incisal bite force of complete denture wearers using pressure transducers - a clinical study

  • Kalra, Pawan;Nadiger, Ramesh;Shah, Farhan Khalid
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권2호
    • /
    • pp.97-102
    • /
    • 2012
  • Study was conducted to determine and assess the effect of different type of denture adhesives on the incisal bite force of complete denture wearers until the dislodgement of upper denture, using pressure transducer. MATERIALS AND METHODS. 30 patients out of 100 were included in the study. Based on the Kapur's method of scoring denture retention and stability, these patients were divided into 3 groups-Group A - Clinically good dentures; Group B - Clinically fair dentures; and Group C - Clinically poor dentures. A custom made occlusal force meter was constructed based on the load cell type of pressure transducers. Different adhesives (powder, paste and adhesive strips) were used in the study. Complete denture wearers were asked to bite on the load cell and the readings of incisal bite force were recorded. The readings of incisal bite force were subjected to statistical analysis using Repeated measures ANOVA followed by post-hoc bonferroni test. RESULTS. The result suggests that denture adhesives improved the incisal bite force of complete denture wearers significantly The incisal bite force (in kg) in Group A without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 2.48 (${\pm}0.16$), 3.43 (${\pm}0.11$), 6.01 (${\pm}0.11$), 3.22 (${\pm}0.09$) respectively. The incisal bite force (in kg) in Group B without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.87 (${\pm}0.18$), 3.35 (${\pm}0.14$), 5.34 (${\pm}0.18$), 3.21 (${\pm}0.12$) respectively. The incisal bite force (in kg) in Group C without using adhesives, with powder adhesive, with paste adhesive and with adhesive strips was found to be 1.00 (${\pm}0.17$), 3.07 (${\pm}0.14$), 4.37 (${\pm}0.26$), 2.99 (${\pm}0.14$) respectively. CONCLUSION. Within the limitations of the study, it was concluded that the use of denture adhesive was found to be significantly effective in improving the incisal bite force of complete dentures until the dislodgement of upper denture. Fittydent paste adhesive was found to be more effective than the powder and strips adhesives. The improvement in incisal bite force was found to be higher in Group C in comparison to that of Group A and Group B.

의치접착제의 임상적 효용성 (Clinical Usefulness of Denture Adhesives)

  • 이진한;임영준;이석형;이준석
    • 구강회복응용과학지
    • /
    • 제28권2호
    • /
    • pp.163-169
    • /
    • 2012
  • 의치접착제는 의치의 유지와 기능을 향상시키기 위해 사용하는 재료이다. 오랜 기간동안 의치접착제는 치과의사들에게 거부감을 느끼는 재료로써 받아들여졌다. 그럼에도 불구하고 의치접착제의 수요는 늘어나는 것으로 보인다. 본 논문에서는 문헌고찰을 통하여 의치접착제의 종류와 작용 기전, 세균부착성, 유지력과 임상적 효과에 대하여 고찰해 보고, 적절한 임상에 적용과 효용성에 대하여 알아보고자 하였다.

시간에 따른 의치접착제의 인장 결합강도와 세포독성의 변화 (Evaluation of changes in adhesive strength and cytotoxicity of a denture adhesive according to time)

  • 정하윤;김지환;이근우;심준성;문홍석
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.232-239
    • /
    • 2009
  • 연구목적: 많은 의치 환자들은 의치의 유지력, 안정성 그리고 저작기능을 향상시키기 위해 의치접착제를 사용하고 있다. 이상적인 의치접착제는 독성이나 자극이 없고, 구강점막에 편안함을 제공하고, 나쁜 냄새나 맛이 없어야 한다. 의치접착 크림의 세포독성 여부를 확인하고, 의치접착제의 효과와 시간에 따른 유지력의 변화를 알아보고자 하였다. 연구재료 및 방법: 의치접착크림의 세포독성 여부를 알아보기 위해 mouse 섬유아세포를 이용한 MTT 시험을 통해 의치접착크림의 농도와 1일에서 4일까지의 시간에 따른 세포독성 여부를 평가하였다. 의치 접착제가 유지력 향상에 미치는 효과와 시간에 따른 유지력의 변화를 알아보기 위해 무치악 덴티폼과 이에 맞는 의치상을 제작하여 의치 접착제 적용 후 3일까지의 인장결합강도를 측정하였다. 결과: 1. 의치접착크림은 농도와 시간에 따라 세포독성이 관찰되는 것은 없었다. 2. 의치접착크림과 인공타액을 동시에 사용한 경우 통계학적으로 가장 높은 인장 결합강도를 나타내었고, 의치접착크림을 단독으로 사용한 경우보다 인장 결합강도가 통계학적으로 유의성 있게 높았다. 이는 인공타액과 의치접착크림의 인장 결합강도의 단순 합계보다 높았다. 3. 의치접착크림과 인공타액을 동시에 사용한 군에서 도포 후부터 1시간 후까지 인장 결합강도는 최대치를 기록하였고 3시간부터 인장 결합강도는 점차 감소하기 시작하여 12시간 후는 최대 인장 결합강도의 70%, 1일후에50%까지 감소하였다. 이상의 결과를 토대로 의치접착크림은 1일에서 4일까지 세포독성이 없었고 의치의 유지력을 향상시키는데 효과적이며, 타액과 같이 작용하여 효과를 더 발휘할 수 있었다. 향후 장기적인 사용에 따른 다양한 세포독성 실험과 접착력의 감소에 대한 연구가 필요하리라 사료된다.

Effect of adhesive primers on bonding strength of heat cure denture base resin to cast titanium and cobalt-chromium alloy

  • Kim, Su-Sung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.41-46
    • /
    • 2009
  • STATEMENT OF PROBLEM. The poor chemical bonding of a denture base resin to cast titanium framework often introduces adhesive failure and increases microleakage. PURPOSE. This study evaluated the shear bond strengths of a heat cure denture base resin to commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy using two adhesive primers. MATERIAL AND MATHODS. Disks of commercially pure titanium, Ti-6Al-4V alloy and a cobalt-chromium alloy were cast. Specimens without the primer were also prepared and used as the controls. The shear bond strengths were measured on a screw-driven universal testing machine. RESULTS. The primers significantly(P < .05) improved the shear bond strengths of the heat cure resin to all metals. However, the specimens primed with the Alloy $primer^{(R)}$(MDP monomer) showed higher bond strength than those primed with the MR $bond^{(R)}$(MAC-10 monomer) on titanium. Only adhesive failure was observed at the metal-resin interface in the non-primed specimens, while the primed specimens showed mixed failure of adhesive and cohesive failure. CONCLUSIONS. The use of appropriate adhesive metal primers makes it possible not only to eliminate the need for surface preparation of the metal framework before applying the heat cure resins, but also reduce the need for retentive devices on the metal substructure. In particular, the Alloy $primer^{(R)}$, which contains the phosphoric acid monomer, MDP, might be clinically more acceptable for bonding a heat cure resin to titanium than a MR $bond^{(R)}$, which contains the carboxylic acid monomer, MAC-10.

구순암 환자에서의 의치접착제를 이용한 상악 총의치와 심한 치주 상태에서의 하악 이중관의치를 이용한 수복 증례 (Prosthetic treatment for patient with upper lip cancer and severe periodontitis: Maxillary complete denture with denture adhesive and mandibular double crown-retained removable partial denture)

  • 최현석;이청희;조진현
    • 대한치과보철학회지
    • /
    • 제53권1호
    • /
    • pp.74-80
    • /
    • 2015
  • 구강암의 발생 시, 구순의 결손과 방사선치료에 의한 치주조직과 치경부우식증 등의 문제가 발생할 수 있다. ADI (Association of dental implantology)에 의하면 상 하악골에 대한 방사선치료가 최근에 시행되었을 경우 임플란트를 식립하는 것은 상대적 비적응증이 된다. 대부분의 경우 임플란트를 이용한 보철물의 제작이 어렵고 의치를 사용한 수복이 이루어지게 된다. 특히, 구강암 수술로 인한 구순결손은 의치의 유지에 심각한 영향을 주게 된다. 본 증례는 상순암을 가진 환자로 일차적으로 절제술을 시행하고, 이차적으로 방사선 치료가 정기적으로 이루어진 결과, 환자의 상악 치아들은 순차적으로 자연 발치되었고, 하악은 매우 불량한 치주상태를 나타내었다. 상악은 총의치에 의치접착제를 적용하여 구순결손에 의한 의치의 유지력 저하를 극복하였고, 하악에서는friction pin을 이용한 하악이중관의치가 2년 동안 성공적으로 사용되었다.

Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base

  • Park, Se-Jick;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.262-272
    • /
    • 2022
  • PURPOSE. This study aimed to analyze the shear bond strength between the 3D-printed denture base and the chairside relining material, according to the surface treatment. MATERIALS AND METHODS. Cylindrical specimens were prepared using DENTCA Denture Base II. The experimental groups were divided into 6 (n = 10): no surface treatment (C), Tokuyama Rebase II Normal adhesive (A), sandblasting (P), sandblasting and adhesive (PA), sandblasting and silane (PS), and the Rocatec system (PPS). After bonding the chairside relining material to the center of the specimens in a cylindrical shape, they were stored in distilled water for 24 hours. Shear bond strength was measured using a universal testing machine, and failure mode was analyzed with a scanning electron microscope. Shear bond strength values were analyzed using one-way analysis of variance, and Tukey's honest significant difference test was used for post-hoc analysis (P < .05). RESULTS. Group PPS exhibited significantly higher shear bond strength than all other groups. Groups P and PA displayed significantly higher bond strengths than the control group. There were no significant differences between groups PS and A compared to the control group. Regarding the failure mode, adhesive failure occurred primarily in groups C and A, and mixed failure mainly in groups P, PA, PS, and PPS. CONCLUSION. The shear bond strength between the 3D-printed denture base and the chairside relining material exhibited significant differences according to the surface treatment methods. It is believed that excellent adhesive strength will be obtained when the Rocatec system is applied to 3D-printed dentures in clinical practice.

의치 접착제의 효과 및 임상적 적용 시 고려 사항 (Effects and clinical considerations of denture adhesives)

  • 박근택;조리라;박찬진;허윤혁;고경호
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.385-391
    • /
    • 2020
  • 의치 접착제는 의치의 유지와 안정을 향상시키기 위해 사용하는 재료로, 용해성과 비용해성으로 구분된다. 의치 접착제는 의치의 유지와 안정, 환자의 저작 기능 향상에 도움을 준다. 세정 등 위생관리가 잘 이루어져야 하며, 지지 조직 상태 및 의치의 적합을 평가하기 위한 주기적인 검진이 필수적이다. 수많은 치과의사들은 의치 접착제의 효과에 대해 막연히 알고만 있을 뿐, 사용 시 주의사항이나 관리 방법에 관해서는 제조사의 지시에 의존하는 경우가 많다. 본 논문에서는 의치 접착제의 성질, 효과, 사용 시 주의사항을 살펴보고, 환자와 전문가를 위한 임상적 지침을 제시하고자 하였다.

금속표면처리제에 따른 코발트-크롬 합금과 의치상용 레진의 결합강도 (BOND STRENGTH BETWEEN COBALT-CHROMIUM ALLOY AND DENTURE BASE RESIN ACCORDING TO ADHESIVE PRIMERS)

  • 박종일;권주홍;이해형;조혜원
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.160-168
    • /
    • 2000
  • This study evaluated the effects of four adhesive metal primers on the shear bond strength of a heat curing denture base resin(Lucitone 199) to cobalt-chromium alloy(Biosil-f). The adhesive metal primers were Cesead Opaque Primer, Metal Primer, MR Bond, and Super-Bond liquid. The metal surface primed or nonprimed was filled with the heat-curing methyl methacrylate resin. The specimens were stored in water at $37^{\circ}C$ for 24 hours and the alternately immersed in water bath at $5^{\circ}C\;and\;55^{\circ}C$ for up to 2,000 thermal cycles. Shear bond strengths were measured using UTM at a crosshead speed of 0.5mm/min. Failure surface were examined under magnifying glasses. All the primers examined improved the shear bond strength between denture base resin and cobalt-chromium alloy compared with nonprimed specimens before thermal cycling. The bond strength of Cesead Opaque Primer was greatest. And after 2,000 thermal cycles, the bond strengths between resin and cobalt-chromium alloy were decreased but the difference between thermal cycling 0 and 2,000 at Cesead Opaque primer and Metal Primer were not significant. This study indicated that Cesead Opaque Primer & Metal Primer is effective primers to obtain higher bond strength between heat cured denture base resin and cobalt-chromium alloy.

  • PDF

의치 세정제가 의치상 레진과 이장용 레진의 결합강도와 표면경도에 미치는 영향 (THE EFFECT OF DENTURE CLEANSERS ON THE BOND STRENGTH AND THE SURFACE HARDNESS OF RELINE RESIN TO DENTURE BASE RESIN)

  • 김계순;정회열;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.493-502
    • /
    • 2003
  • Statement of problem : Removable partial denture and complete denture often require denture base relines to improve the fittness against tissue-bearing mucosa because of the gradual change in edentulous ridge contour and resorption of underlyng bony structure. Self-curing hard reline resins offers the immediate and relatively inexpensive means to be recondition the surface of denture base directly However weak bond between denture base resin and reline material can harbor bacteria, promote staining, or result in complete separation of the two materials. Purpose : The purpose of this study was to evaluate the effect of denture cleansers on bond strength and surface hardness of reline resin to denture base resin Denture base resin beams($60.0{\times}15.0{\times}3.0mm$) were made with Lucitone 199. Material and methods : 10mm section was removed from the center of each specimen. The samples were replaced in the molds and the space of l0mm sections were packed with Tokuso Rebase reline material. The specimens were immersed in denture cleansers (Polident, Cleadent) and were evaluated after 1 week, 2 weeks, and 4 weeks. The bond strength and surface hardness of self-curing hard reline materials to heat-curing denture base resin were measured using an UTM (universal testing machine). Results and conclusion : 1) There was no significant difference of usage, kind, and denture cleaner by application time on the bonding strength of self-curing hard reline resin to denture base resin. 2) There was no significant difference of usage, kind, and denture cleaner by application time on the surface hardness, but the surface hardness showed decreasing tendency, as the time of immersion was extended. 3) The failure modes of the specimens was initially adhesive failure and finally cohesive failure of self-curing hard reline resin.