• Title/Summary/Keyword: Dentinal penetration

Search Result 47, Processing Time 0.019 seconds

COMPARISON OF THE MARGINAL LEAKAGE OF SEVERAL FILLING MATERIALS ON CLASS V CAVITIES (제오급와동(第五級窩洞) 수복(修復)에 사용(使用)되는 수종(數種) 충전재(充塡材)의 변연누출(邊緣漏出) 비교(比較))

  • Kim, Mi-Ok;Cho, Kyew-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.20-29
    • /
    • 1989
  • The purpose of the study is to evaluate the degree of the marginal leakage of class V cavities with 4 brands of esthetic filling materials by means of the dye penetration at the enamel & dentinal margins. 160 cavities of class V were prepared on the buccal & lingual surfaces of 80 extracted premolar teeth, which divided into 4 groups. The four groups of cavities were filled with Durafill$^{(R)}$-Durafill bond$^{(R)}$(KuIzer & Co GmbH), Bisfil M$^{(R)}$-Resin bond$^{(R)}$(BISCO Inc.), Silux$^{(R)}$-Scotchbond$^{(R)}$(3M Co.) and Fuji ionomer$^{(R)}$(type II, G-C Co.) each. All specimens were immersed in 2% methylene blue dye solution for 24 hours at $37^{\circ}C$ after a 30-second thermocycling at $4^{\circ}C$ and $60^{\circ}C$ and longitudinally sectioned with diamond disk into two parts. The results were as follows : 1. At enamel margins, the group filled with Durafill$^{(R)}$-Durafill bond$^{(R)}$, Bisfil M$^{(R)}$-Resin bond$^{(R)}$ and Silux$^{(R)}$-Scotchbond$^{(R)}$ show no significant difference each other(p>0.05), and the above groups show less marginal leakage comparing with the group filled with Fuji ionomer$^{(R)}$(p<0.01). 2. At dentinal margins, the group filled with Silux$^{(R)}$-Scotchbond$^{(R)}$ or Fuji ionomer$^{(R)}$ show less marginal leakage than that with Durafill$^{(R)}$-Durafill bond$^{(R)}$ or Bisfil M$^{(R)}$-Resin bond$^{(R)}$(p<0.01). 3. The enamel margins show less marginal leakage than dentinal margins in all the class V cavities(p<0.01).

  • PDF

Quantitative Micro-CT Evaluation of Microleakage in Composite Resin Restorations (Micro-CT를 이용한 복합 레진 수복물 미세 누출도의 정량 분석)

  • Lee, Sang-Ik;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.222-233
    • /
    • 2007
  • One of the most important and basic test of dental restorative materials is the evaluation of microleakage into the tooth-restorative interface. There are many techniques to test microleakage, but most of them have several disadvantages. Recently developed microtomography(micro-CT) can provide the three dimensional image and information about the internal component in non-destructive way, therefore using micro-CT, it is possible to evaluate microleakage exactly in quantitative manner. The purpose of this study is to find a new method for quantitative and non-destructive evaluation of microleakage in composite resin restorations using micro-CT and to compare the new method with conventional dye penetration method. Thus, microleakages of two kinds of dentin bonding systems were evaluated with above two methods. 40 extracted sound human premolars were randomly divided into two groups consisting of 20 samples and restored accordingly. Group 1 : Class V resin restorations with $Adper^{TM}$ Singe Bond Group, 2 : Class V resin restorations with $Adper^{TM}\;Promp^{TM}$ L-pop. The $Filtek^{TM}$ Supreme was applied to the Class V cavities of all teeth. After that, 10 teeth from each group were applied to evaluation of microleakage using micro-CT, and other 10 teeth from each group were using conventional dye penetration method. The conclusions of this study were as follow : 1 Using micro-CT, Group 1 showed significantly less microleakage than Group 2 and there was statistically significant difference(p<0.01) between two groups. 2. Using conventional dye penetration method, Group 1 leaked less than Group 2 and there was statistically significant difference(p<0.01) between two groups 3. The difference between two groups is more evident in the method using micro-CT. 4. In all two methods, microleakage appeared more into the cavities to dentinal margins than enamel margins.

  • PDF

THE EFFECT OF SMEAR LAYER TREATMENT ON THE MICROLEAKAGE (Smear layer 처리에 따른 미세누출에 대한 연구)

  • Lee, Jung-Min;Park, Sang-Hyuk;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.378-389
    • /
    • 2006
  • The purpose of this study was to compare the sealing ability of root canal obturation with or without the treatment of smear layer. Eighty extracted human teeth with one canal were selected Instrumentation was performed with crown-down technique. After instrumentation, root canals of the NaOCl group and NaOCl-6 group were irrigated with 3% NaOCl. EDTA group and EDTA-6 group were irrigated with 17% EDTA. Then all teeth were obturated using continuous wane obturation technique NaOCl group and EDTA group were immersed in methylene blue solution for 84hours. NaOCl-6 group and EDTA-6 group were immersed in methylene blue solution for 6months. The teeth were sectioned at 1.5 mn (Level 1), 3.0 mm (Level 2) and 4.5 mm (Level 3) from the root apex. The length of dye-penetrated inter-face and the circumferential length of canal at each level were measured using Sigma-Scan Pro 5.0. 1. The mean leakage ratio was decreased cervically. 2. NaOCl group showed higher mean leakage ratio than EDTA group at each level. But there was significant difference at level 1 only (p < 0.05). 3. NaOCl-6 group showed higher mean leakage ratio than EDTA-6 group at each level. But there was significant difference at level 1 only (p < 0.05). 4. NaOCl-6 group showed higher mean leakage ratio than NaOCl group at each level. But there was significant difference at level 1 only (p < 0.05). 5. EDTA-6 group showed higher mean leakage ratio than EDTA group at each level. But there was no significant difference. 6. In NaOCl group and NaOCl-6 group, scanning electron micrographs of tooth sections generally covered with smear layer. In EDTA group and EDTA-6 group, tooth sections showing the penetration of sealers to opened dentinal tubules. The results suggest that removal of smear layer was effective to reduce the apical microleakage of the root canal.

An Experimental Study on the Effect of Laser to Bond Strength between Composite Resin and Bovine Teeth (우치치질에 레이저조사시 레진과의 결합강도에 관한 연구)

  • Cho, Ju-On;Song, Kwang-Yeob;Park, Charn-Woon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.2
    • /
    • pp.155-172
    • /
    • 1989
  • The purpose of this study is to measure the bonding strength at the enamel and dentin of extracted bovine incisors when they are irradiated by W Nd: YAG, EoQ Nd: YAG, and CW $CO_2$ laser, etched and then attached by composite resin. The laser-irradiated surface, the etched surface after the laser-irradiation and the interface of the treated surface and resin are observed by using scanning electron microscope. The NP Nd:YAG laser is used at the peam power of 207 KW. The EOQ Nd: YAG laser is used at the peak power of 1.15Mk. The CW $CO_2$ laser is used at the energy output of 5W and 10W in enamel; in dentin, at the energy output of 2W. The obtained results were as follows: 1. The shear bond strength of enamel decreased in the following order: EOQ Nd:YAG laser group, NP Nd:YAG laser group, CW $CO_2$ laser groups, unlased group. The unlased group showed a significant difference from EOQ Nd:YAG laser group (P<0.01), NP Nd:YAG laser group (P<0.05), but no significant difference from CW $CO_2$ laser group (P>0.05). 2. The shear bond strength of dentin decreased in the following order: CW $CO_2$ laser group, NP Nd:YAG laser group, unlased group, EOQ Nd:YAG laser group. The unlased group showed a significant difference from CW $CO_2$ laser group (P<0.01), but no significant difference from Nd:YAG laser groups (P>0.05). 3. The scanning electron microscope of enamel revealed irregular microcrack and pore at the surface in the NP Nd:YAG laser group and CW $CO_2$ laser group, but the crackless flat surface in the EOQ Nd:YAG laser group. 4. The scanning electron microscope of dentin revealed obstruction of in most of dentinal tubule and decrease of diameter. 5. The scanning electron microscope of the interface of resin and enamel revealed prominent penetration of resin tag in the EOQ Nd:YAG laser group.

  • PDF

THE ADHESIVE PATTERNS OF COMPOMER TO SALIVA-CONTAMINATED DENTIN (타액에 오염된 상아질에 대한 콤포머의 접합양상)

  • Cho, Young-Gon;Kim, Byung-Tae;Lee, Suk-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.575-586
    • /
    • 2000
  • In this study, adaptation of compomer to saliva contaminated dentin was evaluated with scanning electron microscope(SEM) and confocal laser scanning microscope(CLSM). For the SEM study, the occulusal surfaces of thirty two molar teeth were grounded to exposure dentin surfaces. The specimen were randomly assigned to control and three experimental groups with four samples in each group. In control group, Dyract and F-2000 compomer were bonded on the specimens according to the manufactures direction. Experimental groups were subdivided into three groups. They were contaminated with saliva on dentin surfaces ; Experimental group 1 : Saliva was dried with compressed air. Experimental group 2 : Saliva was rinsed with air-water spray and dried. Experimental group 3 : After polymerization of an adhesive, they were contaminated with saliva, and then saliva was rinsed with air-water spray and dried. Dyract and F-2000 compomer were bonded on saliva-treated dentin surfaces. The interfaces between dentin and compomer were observed with SEM. For the CLSM study, Class V cavities were prepared in buccal and ligual surfacess of thirty two molars. The specimens were divided into control and experimental groups. Class V cavities in experimental group were contaminated with saliva and those surfaces in each experimental groups received the same treatments as for the SEM study. Cavities were applied Prime & Bond 2.1 and F-2000 compomer primer/adhesive that were mixed with fluorescein, and then were filled with Dyract and F-2000 compomer. Specimens were embedded in transparent acrylic resin and sectioned buccolingual1y with diamond wheel saw, and then mounted on cover slide for CLSM study. The interface between cavity and compomer was observed by fluoresence imaging with a CLSM. The results were as follows : 1. In SEM exammination of Dyract group, control group, experimental group 2, 3 showed close adaptation to dentin and hybrid layer of $3{\sim}4{\mu}m$ diameter. Interfacial gap between compomer and dentin in experimental group 1 was wider than in control group. 2. In SEM examination of F-2000 group, adaptation to dentin of control group was closer than Dytact control group, but hybrid-like layer was not observed. Interfacial gap between compomer and dentin in experimental group 1 was wider than in Dyract experimental group 1. 3. In dissolution specimens of Dyract and F-2000 group, resin tags penetrated through dentinal tubules in control group and experimental group 1 and 3, but the penetration of resin tag was irregular and partial in experimental group 1. 4. In CLSM exammination of Dyract and F-2000 group, adhesive patterns of control and experimental groups showed same as in SEM. This result suggests the treatment methods, rinsing & drying, repeating all adhesive procedures, will produce good effect on adaptation of compomer to dentin if the dentin surface or polymerized adhesive is contaminated by saliva.

  • PDF

A STUDY ON THE BONDING OF COMPOMER TO DECIDUOUS DENTIN (컴포머와 유치 상아질의 결합에 관한 연구)

  • Kim, Jee-Tae;Kim, Yong-Kee;Kim, Jong-Soo;Kwon, Soon-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.509-518
    • /
    • 2002
  • The purpose of this study was to evaluate the bonding of compomer to deciduous dentin which is known to have been developed to improve the weak properties of glass ionomer cement and composite resin. 120 sound primary molars were used for the shear bond strength test and another 24 for the scanning electron microscopic evaluation. Each material was ailed into polyethylene mold attached to exposed dentinal surface($3{\times}4mm$ in diameter) of sample blocks. Shearbond strength was measured using Universal testing machine and data were analyzed statistically with Oneway-ANOVA and Scheffe test. Scanning electron microscopic observation was performed in order to evaluate the pattern of distribution and penetration of resin tags and hybrid layer. Compomer groups(II-V) showed significantly higher bond strength values than glass ionomer group(I)(p<.05). Etching-compomer groups(III, V) showed the significantly higher bond strength than non-etching compomer groups(II, IV)(p<.05), but slightly lower values than composite resin group(VI) with no statistically significant difference(p>.05). No significantly different bond strength was found between compomer groups of different bonding system(p>.05). Scanning electron micrographs showed more irregular distribution of short and thin resin tags in non-etching compomer groups(II, IV) whereas the more regular and intimate distribution of long and thick tags in etching compomer groups(III, V) and composite resin group(VI). The evaluation of hybrid layer also showed more regular formation of thicker layer in etching compomer groups(III, V). Based on the results of present study, the use of compomer as an esthetic restorative material for primary molars might be justified.

  • PDF

A STUDY OF ADDITIONAL VIBRATION EFFECT ON DENTIN BOND STRENGTH (진동이 상아질 결합력에 미치는 영향에 관한 연구)

  • Lee, Jin;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.4
    • /
    • pp.632-640
    • /
    • 2002
  • The objective of the study was to apply the vibration technique to reduce the viscosity of bonding adhesives and thereby compare the bond strength and resin penetration into dentinal tubules achieved with those gained using the conventional technique. Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel and were embedded in 1-inch PVC pipe with acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form one flat surface, and the samples were subsequently polished with silicon carbide abrasive papers. The samples were randomly assigned to 4 groups(n=22). On Group 1 and 2, Single Bond(3M-ESPE, St. Paul, USA) was used, and on Group 3 and 4, One-Step(Bisco Inc., Schaumburg, USA) was used, and each was applied according to its manufacturer's instructions. For Group 2 and Group 4, vibration was applied with ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. Resin composite was condensed on to the prepared surface in two increments using a mold kit(Ultradent Products Inc., USA) and each was light-cured for 40 seconds. After 24 hours in tap water at room temperature the specimens were thermocycled, and shear bond strengths were measured with a universal testing machine(Instron 4465, Canton, USA). To investigate infiltration patterns of the adhesive materials, the surface of specimen was examined with scanning electron microscope. The results were as follows. 1. The shear bond strengths of vibration groups(Group 2, Group 4) were significantly greater than those of the non-vibration groups(Group 1, Group 3)(p<0.05). 2. The shear bond strengths of Single Bond and One-Step were not significantly different (p>0.05). 3. The vibration groups showed greater number of resin tags in tubules and lateral branches under SEM.

  • PDF