• 제목/요약/키워드: Dental unit water

검색결과 43건 처리시간 0.033초

Fatigue resistance, debonding force, and failure type of fiber-reinforced composite, polyethylene ribbon-reinforced, and braided stainless steel wire lingual retainers in vitro

  • Foek, Dave Lie Sam;Yetkiner, Enver;Ozcan, Mutlu
    • 대한치과교정학회지
    • /
    • 제43권4호
    • /
    • pp.186-192
    • /
    • 2013
  • Objective: To analyze the fatigue resistance, debonding force, and failure type of fiber-reinforced composite, polyethylene ribbon-reinforced, and braided stainless steel wire lingual retainers in vitro. Methods: Roots of human mandibular central incisors were covered with silicone, mimicking the periodontal ligament, and embedded in polymethylmethacrylate. The specimens (N = 50), with two teeth each, were randomly divided into five groups (n = 10/group) according to the retainer materials: (1) Interlig (E-glass), (2) everStick Ortho (E-glass), (3) DentaPreg Splint (S2-glass), (4) Ribbond (polyethylene), and (5) Quad Cat wire (stainless steel). After the recommended adhesive procedures, the retainers were bonded to the teeth by using flowable composite resin (Tetric Flow). The teeth were subjected to 10,00,000 cyclic loads (8 Hz, 3 - 100 N, $45^{\circ}$ angle, under $37{\pm}3^{\circ}C$ water) at their incisoproximal contact, and debonding forces were measured with a universal testing machine (1 mm/min crosshead speed). Failure sites were examined under a stereomicroscope (${\times}40$ magnification). Data were analyzed by one-way analysis of variance. Results: All the specimens survived the cyclic loading. Their mean debonding forces were not significantly different (p > 0.05). The DentaPreg Splint group (80%) showed the highest incidence of complete adhesive debonding, followed by the Interlig group (60%). The everStick Ortho group (80%) presented predominantly partial adhesive debonding. The Quad Cat wire group (50%) presented overlying composite detachment. Conclusions: Cyclic loading did not cause debonding. The retainers presented similar debonding forces but different failure types. Braided stainless steel wire retainers presented the most repairable failure type.

도재 수리 시스템의 전단결합강도에 관한 연구 (Shear Bond Strength of Porcelain Repair Systems)

  • 우수;신수연;조인호
    • 구강회복응용과학지
    • /
    • 제22권3호
    • /
    • pp.211-220
    • /
    • 2006
  • Need of porcelain-repair system is largely demanding as dental porcelain restorations are increased in clinical dentistry. This study investigated shear bond strength of commercial porcelain-repair systems on dental porcelain and their reliability. Experimental groups were as follows; Group A Super Bond C&B, Group B Porcelain repair kit, Group C Ceramic repair, and Group D Spectrum system as a control. Porcelain disks were fired and embedded in epoxy resin. Porcelain surface were ground using 220 grit SiC disk, then cleaned in ultrasonic bath. Then porcelain specimens were treated with each repair system. A clear polystyrene cylinder 3.5 mm in internal diameter was filled with composite resin. Then the resin cylinder was polymerized with a visible light curing unit. Thirty one specimens at each group were prepared and stored at $37^{\circ}C$ distilled water for 48 h. Specimens were tested in an Instron testing machine according to ISO TR 11405. Mean shear bond strength and standard deviation of each group was $15.7{\pm}4.1MPa$ (Group A), $12.8{\pm}4.9MPa$ (Group B), $7.2{\pm}3.0MPa$ (Group C) and $9.6{\pm}2.2MPa$ (Group D). ANOVA and Tukey HSD post-hoc test showed that there were significant differences between groups (p<0.05). Data of bond strength were analyzed with two-parameter Weibull distribution. Confidence interval of Weibull modulus (m-parameter) at 95% of Group A (3.5-6.3) and Group D (3.6-6.0) were significantly higher than Group B (2.2-3.7) and Group C (2.0-3.4). There was little correlation between mean shear bond strength and Weibull modulus. Results indicated that acid-etching of porcelain surface increased porcelain-resin shear bonding strength.

Effects of 3 different light-curing units on the physico-mechanical properties of bleach-shade resin composites

  • Azin Farzad;Shahin Kasraei;Sahebeh Haghi;Mahboubeh Masoumbeigi;Hassan Torabzadeh;Narges Panahandeh
    • Restorative Dentistry and Endodontics
    • /
    • 제47권1호
    • /
    • pp.9.1-9.11
    • /
    • 2022
  • Objectives: This study investigated the microhardness, flexural strength, and color stability of bleach-shade resin composites cured with 3 different light-curing units. Materials and Methods: In this in vitro experimental study, 270 samples were fabricated of bleach and A2 shades of 3 commercial resin composites (Point 4, G-aenial Anterior, and Estelite Sigma Quick). Samples (n = 5 for each trial) were cured with Bluephase N, Woodpecker LED.D, and Optilux 501 units and underwent Vickers microhardness and flexural strength tests. The samples were tested after 24 hours of storage in distilled water. Color was assessed using a spectrophotometer immediately after preparation and 24 hours after curing. Data were analyzed using 3-way analysis of variance and the Tukey test (p ≤ 0.001). Results: Samples cured with Optilux exhibited the highest and those cured with LED.D exhibited the lowest microhardness (p = 0.023). The bleach shade of Point 4 composite cured with Optilux displayed the highest flexural strength, while the same composite and shade cured with Sigma Quick exhibited the lowest (p ≤ 0.001). The color change after 24 hours was greatest for the bleach shade of G-aenial cured with Bluephase N and least for the A2 shade of Sigma Quick cured with Optilux (p ≤ 0.001). Conclusions: Light curing with polywave light-emitting diode (LED) yielded results between or statistically similar to those of quartz-tungsten-halogen and monowave LED in the microhardness and flexural strength of both A2 and bleach shades of resin composites. However, the brands of light-curing devices showed significant differences in color stability.

고분자 기반 코팅형 상아질 지각 과민 처치제의 효과에 대한 비교 연구 (Comparison of high molecular coating type dentine hypersensitivity desensitizers)

  • 노영훈;이주연;박현정;최차남;박윤정;구기태;김태일;설양조;이용무;구영;류인철;정종평
    • 대한치과의사협회지
    • /
    • 제46권11호
    • /
    • pp.683-688
    • /
    • 2008
  • Purpose : The aim of this study was to evaluate the clinical efficacy of two commercially available desensitizing agents over 3 weeks on patients with dentin hypersensitivity. Materials and Methods : An oxalate-based solution, Sensblok (NIBEC Inc. Seoul, Korea) & Superseal (Pheonix Inc. Michigan, USA), and a distilled water placebo were compared in a clinical setting. Seven volunteers exhibiting three or more teeth that were sensitive to tactile & air were enrolled in the study (35 teeth total). A visual analog scale (VAS) was used for recording each patient s level of sensitivity to tactile & air stimuli. A Florida probe was rubbed across the exposed dentin three times with a constant pressure 20 grams to measure the tactile stimulus. The air stimulus was generated by dental unit air syringe for 1-second blast from 1/2 inch distance. The desensitizing agents were applied according manufacture s guideline. VAS scores were recorded at baseline, 1 minute after treatment, at 1 week, 2weeks, 3weeks. VAS score were analyzed using a repeated measures ANOVA ( =0.05). Results : The Sensblok, Superseal, and distilled water placebo all decreased dentin sensitivity. A statistically significant difference existed between Sensblok and placebo when tactile stimulus was applied (P<0.05), but no significant difference was found among other desensitizing agents and tactile and air stimuli.

  • PDF

Inhibitory effect on Streptococcus mutans and mechanical properties of the chitosan containing composite resin

  • Kim, Ji-Sun;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • 제38권1호
    • /
    • pp.36-42
    • /
    • 2013
  • Objectives: This study evaluated the antibacterial effect and mechanical properties of composite resins ($L_{CR}$, $M_{CR}$, $H_{CR}$) incorporating chitosan with three different molecular weights (L, Low; M, Medium; H, High). Materials and Methods: Streptococcus (S). mutans 100 mL and each chitosan powder were inoculated in sterilized 10 mL Brain-Heart Infusion (BHI) solution, and was centrifuged for 12 hr. Absorbance of the supernatent was measured at $OD_{660}$ to estimate the antibacterial activities of chitosan. After S. mutans was inoculated in the disc shaped chitosan-containing composite resins, the disc was cleansed with BHI and diluted with serial dilution method. S. mutans was spread on Mitis-salivarius bacitracin agar. After then, colony forming unit (CFU) was measured to verify the inhibitory effect on S. mutans biofilm. To ascertain the effect on the mechanical properties of composite resin, 3-point bending and Vickers hardness tests were done after 1 and 3 wk water storage, respectively. Using 2-way analysis of variance (ANOVA) and Scheffe test, statistical analysis was done with 95% significance level. Results: All chitosan powder showed inhibition effect against S. mutans. CFU number in chitosan-containing composite resins was smaller than that of control resin without chitosan. The chitosan containing composite resins did not show any significant difference in flexural strength and Vickers hardness in comparison with the control resin. However, the composite resin, $M_{CR}$ showed a slightly decreased flexural strength and the maximum load than those of control and the other composite resins $H_{CR}$ and $L_{CR}$. Conclusions: $L_{CR}$ and $H_{CR}$ would be recommended as a feasible antibacterial restorative due to its antibacterial nature and mechanical properties.

복합레진의 초기 동적 체적 중합수축의 실시간 측정 -새로운 측정장치의 개발에 대한 소고- (A NEW METHOD - REAL TIME MEASUREMENT OF THE INITIAL DYNAMIC VOLUMETRIC SHRINKAGE OF COMPOSITE RESINS DURING POLYMERIZATION)

  • 이인복
    • Restorative Dentistry and Endodontics
    • /
    • 제26권2호
    • /
    • pp.134-140
    • /
    • 2001
  • The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.

  • PDF

상아질 지각과민 처치제의 임상적 효과에 대한 연구 (CLINICAL STUDY OF DESENSITIZER FOR TREATMENT OF DENTINAL HYPERSENSITIVITY)

  • 조경모;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.219-224
    • /
    • 2000
  • The purpose of this study is for evaluating the effect of MS Coat desensitizing agent in clinical situation. In this study total 60 teeth of 30 patients who is feeling hypersensitivity after periodontal surgery were treated with MS Coat desensitizing agent, and 20 teeth with saline solution for placebo effects and evaluated. All teeth were cleaned with rubber cup and pumice, after then the antibacterial agent was applied for 20 seconds and simply isolated using cotton roll Desensitizing agent was applied with a specific instrument in the manufacturers package by abrading motion for 10 seconds and re-done 8 times. Tactile stimulus with sharp explorer, air stimulus with syringe of dental unit, $7^{\circ}C$ cold water stimulus using micropipette applicator was done to evaluate hypersensitivity before apply test agent, immediate after application, 1 week after, and 3 month after application. The degree of hypersensitivity was recorded using 100mm Visual Analogue Scale and compared between group and evaluation times. From this clinical study sensitivity to the stimulus was significantly induced in both groups and MS Coat made a significant reduction in VAS score than placebo group did(p<.01). The results of this study could demonstrate that MS Coat desensitizing agent can use effectively to heat dentinal hypersensitivity.

  • PDF

크기가 제어된 실리카 나노입자 합성과 제조된 입자의 고분자계 복합재 응용 (Synthesis of Silica Nanoparticles Having the Controlled Size and their Application for the Preparation of Polymeric Composites)

  • 김종웅;김창근
    • 폴리머
    • /
    • 제30권1호
    • /
    • pp.75-79
    • /
    • 2006
  • 고분자계 치아수복용 복합재료에 사용되는 다양한 크기의 나노실리카 입자를 Stober method를 이용하여 제조하고, 3-methacrylofpropyltrimethoxysilane $(\gamma-MPS)$로 제조된 입자 표면 처리 여부에 따른 유기 수지 내에서의 실리카 입자의 분산도 변화를 조사하였다 반응에 사용된 반응물인 tetraethylorthosilicate(TEOS)와 물의 양, 촉매인 암모니아의 양, 용매의 종류와 양을 조절하여 다양한 크기의 나노실리카 입자를 제조하였다. 용매로 에탄올보다 메탄올을 사용할 경우 더 작은 입자가 생성되었다. 또, 물의 함량이 증가할수록 작은 입자가 형성되는 반면, 촉매와 전구체의 경우는 함량이 증가함에 따라 형성된 입자의 크기도 증가하였다. 유기 소재들과의 혼합시 계면 특성 향상을 위해 제조된 친수성의 나노실리카를 $\gamma-MPS$와 반응시켜 소수성의 나노실리카 입자를 제조하였다 실리카 입자 크기가 작을수록 단위 질량당 존재하는 $\gamma-MPS$의 함량은 많았지만, 단위 표면적당 존재하는 $\gamma-MPS$의 양은 실리카 입자의 크기에 영향을 받지 않았다. $\gamma-MPS$로 표면 처리된 실리카 입자의 고분자계 치아수복용 레진 내에서의 분산성은 표면 처리되지 않은 실리카에 비해 크게 향상되었다.

다양한 광원으로 중합한 치과용 접착제의 전단강도에 관한 비교 연구 (THE COMPARATIVE STUDY FOR THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES CURED WITH VARIOUS LIGHT SOURCES)

  • 최남기;조성훈;김선미
    • 대한소아치과학회지
    • /
    • 제38권1호
    • /
    • pp.33-41
    • /
    • 2011
  • 본 연구의 목적은 상업용으로 시판되고 있는 수종의 치과용 접착제를 세대별로 분류하여 서로 다른 광원에 노출 시켜 중합하고 접착면의 전단 강도 측정을 통해 결합강도를 비교함으로써 간접적으로 광원에 따른 접착제의 중합 양상을 알아보고 소아치과 영역에서 가장 권장할만한 치과용 접착제와 광원 종류의 조합을 알아보고자 함이다. 본 연구에서는 최근에 개발된 치과용접착제를 대상으로 다른 유형의 광원으로 중합하였을 때 영구치 상아질에 대한 결합력 비교 평가하여 임상에서 상아질결합제와 광중합 시스템의 적절한 조합을 선택하는데 도움을 주고자 시행하였으며, 실험재료로 Adper Scotchbond Multi-purpose Plus Adhesive (SM; 3M ESPE, USA), Adper Single bond 2 (SB; 3M ESPE, USA), Clearfil SE Bond (SE; Kuraray Medical Inc., Japan), Adper Prompt L-Pop (PL; 3M ESPE, USA), GBond (GB; GC Cooperation Toyko, Japan)을 이용하여 Elipar Free light 2(LED; 3M ESPE, USA), OptiLux 501 (Halogen, Kerr, USA), Flipo (PAC, LOKKI, FRA) 세 가지의 광원으로 중합하고 전단결합강도를 평가한 뒤 다음과 같은 결과를 얻었다. 1. Freelight 2로 중합하였을 때 전단결합강도는 SM이 가장 높았으며($28.22{\pm}5.56$), SB($21.68{\pm}7.44$), SE($20.13{\pm}9.88$), PL($14.18{\pm}5.88$), GB($14.30{\pm}6.81$) 순이었다. SM은 PL, GB와 유의한 차이가 있었으나 (p<0.05), SB, SE, PL, GB 간에는 차이가 없었다. 2. Optiux 501로 중합하였을 때 전단결합강도는 SM이 가장 높았으며 ($22.06{\pm}7.95$), PL($12.94{\pm}4.96$), SB($12.80{\pm}3.35$), SE($12.43{\pm}4.79$), GB($10.00{\pm}3.47$) 순이었고, SM만 유의한 차이가 있었으나 (p<0.05), 다른 군 간에는 차이가 없었다. 3. Flipo로 중합하였을 때 전단결합강도는 SM이 가장 높았으며 ($26.82{\pm}11.16$), PL($15.42{\pm}9.35$), SB($10.96{\pm}3.74$), SE($9.39{\pm}3.74$), GB($7.85{\pm}2.22$) 순이었다. SM은 SB, SE, GB 군과 유의한 차이가 있었으나 (p<0.05), 다른 군 간에는 차이가 없었다. 4. 광원에 따른 차이는 SB와 GB에서만 유의성이 있었고, 다른 결합제에서는 유의한 차이가 없었다. 광원에 따른 유의성을 나타낸 결합제 중 SB는 Freelight 2가 다른 광원에 비해 유의한 차이를 보였고 OptiLux 501과 Flipo간의 차이가 없었던 반면, GB는 Freelight 2와 Flipo 간에만 유의한 차이를 나타냈다.

음용수 불소가 흰쥐태아 법랑모세포의 미세구조에 미치는 영향 (The Effect of Drinking Water Fluoride on the Fine Structure of the Ameloblast in the Fetal Rat)

  • 임도선;정문진;여성문
    • Applied Microscopy
    • /
    • 제29권2호
    • /
    • pp.189-193
    • /
    • 1999
  • 장기간 투여된 불소가 흰쥐태아의 법랑모세포(ameloblast)에 미치는 영향을 알아보고자 임신한 흰쥐에 100ppm, 200ppm 및 300ppm의 불소가 함유된 음용수를 3주간 투여하였으며, 대조군에는 불소가 함유되지 않은 증류수를 섭취시켰다. 생후 11일이 경과된 어린 흰쥐를 희생하여 하악절치를 발치한 후, 법랑모세포의 미세구조적 변화를 관찰하였다. 법랑모세포의 생활주기인 전분비대, 분비대, 성숙대에서 법랑모세포를 광학 및 투과전자현미경으로 관찰한 결과, 실험군에서는 각 대의 법랑모세포에서 형태 및 구조적인 변형을 나타내었다. 즉, 미토콘드리아 기질 내에서 라멜라 형태의 동심원상의 구조가 평륜됨과 함께 조면소포체가 공포화되고 막성계의 유실로 붕괴가 관찰되었다. 특히 고농도 불소투여군에서는 법랑모세포사이에 세포막이 유실된 세포들이 관찰되었다. 따라서, 임신중인 흰쥐에 투여된 불소는 흰쥐태아의 치아발육과정에서 특히, 법랑질 형성에 관여하는 법랑모세포에 영향을 미쳐 전환주기에 변화를 주었고, 법랑모 세포의 미세구조적 및 형태적 변화를 야기하였다.

  • PDF