• Title/Summary/Keyword: Dental prosthesis failure

Search Result 63, Processing Time 0.023 seconds

Retrospective study on survival, success rate and complication of implant-supported fixed prosthesis according to the materials in the posterior area (구치부 임플란트 지지 고정성 보철물의 재료에 따른 생존율, 성공률 및 합병증에 대한 후향적 연구)

  • Chae, Hyun-Seok;Wang, Yuan-Kun;Lee, Jung-Jin;Song, Kwang-Yeob;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.342-349
    • /
    • 2019
  • Purpose: The purpose of this study was to retrospectively investigate the survival and success rate of implant-supported fixed prosthesis according to the materials in the posterior area. Other purposes were to observe the complications and evaluate the factors affecting failure. Materials and methods: Patients who had been restored implant prosthesis in the posterior area by the same prosthodontist in the department of prosthodontics, dental hospital, Chonbuk National University, in the period from January 2011 to June 2018 were selected for the study. The patient's sex, age, material, location, type of prosthesis and complications were examined using medical records. The KaplanMeier method was used to analyze the survival and success rate. The Log-rank test was conducted to compare the differences between the groups. Cox proportional hazards model was used to assess the association between potential risk factors and success rate. Results: A total of 364 implants were observed in 245 patients, with an average follow-up of 17.1 months. A total of 5 implant prostheses failed and were removed, and the 3 and 5 year cumulative survival rate of all implant prostheses were 97.5 and 91.0, respectively. The 3 and 5 year cumulative success rate of all implant prostheses were 61.1% and 32.9%, respectively. Material, sex, age, location and type of prosthesis did not affect success rate (P>.05). Complications occurred in the order of proximal contact loss (53 cases), retention loss (17 cases), peri-implant mucositis (12 cases), infraocclusion (4 cases) and so on. Conclusion: Considering a high cumulative survival rate of implant-supported fixed prostheses, regardless of the materials, implant restored in posterior area can be considered as a reliable treatment to tooth replacement. However, regular inspections and, if necessary, repairs and adjustments are very important because of the frequent occurrence of complications.

Multilateral analysis of $Renova^{(R)}$ implant placement and its Survival rate ($Renova^{(R)}$ 임플란트 식립 후 단기간의 생존율에 대한 다각적 분석)

  • Yang, Jin-Hyuk;Kim, Sung-Tae;Jung, Ui-Won;Nam, Woong;Jung, Young-Soo;Shim, June-Sung;Moon, Hong-Seok;Lee, Keun-Woo;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.3
    • /
    • pp.413-428
    • /
    • 2008
  • Purpose: Given the predictability of dental implant procedure from the studies of successful osseointegration, implant dentistry is often the treatment of choice to replace missing teeth in edentulous patient instead of the fixed prosthesis or removable denture. The $Renova^{(R)}$ dental implant has a RBM(Resorbable Blast Media) surface, internal hex prosthetic connection and a tapered design. At this study gives the analysis of the implant and the short term survival rate of the implant. Material and Methods: In this study, a multilateral analysis was performed on the subjects undergoing placement with $Renova^{(R)}$ implant between August 2006 and February 2008 in Yonsei University dental hospital. 96 implants were placed in 56 patients and they were surveyed for cumulative survival rate. Among them 78 implants in 44 patients were surveyed for the rest analyses. Result: 1. The cumulative survival rate was 96.88% of 96 implants in 56 patients. 2. The mean marginal bone loss was 0.803mm and the marginal bone loss in augmentation group has higher value than the marginal bone loss in non augmentation group. 3. The health scale for the implants were 87% in success group, 9% in satisfactory survival group, 1% in compromised survival group, and 3% in failure group. 4. Two implants placed in poor bone posterior area by 2-stage failed during prosthetic procedure. Conclusion: $Renova^{(R)}$ dental implant showed high cumulative survival rate in installation on partial edentulous ridge and could be a predictable implant system.

Fracture Resistance of Low Invasive Fixed Partial Dentures (수종 저 침습 고정성 국소의치의 수직하중에 대한 저항)

  • Choi, Jong-In;Kim, Yu-Lee;Shin, Chang-Yong;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.241-251
    • /
    • 2010
  • This study aims at contributing to the restorative dentistry by examining results in the vertical load test of four different low invasive fixed partial dentures. Based on a hypothesis on the right upper first molar is missing, three units of FPDs were made for the second premolar and the second molar abutment. that is, twelve metal dies and FPDs were made for resin bonded FPD and Two Key Bridges and Human Bridge without occlusal rest and Human Bridge with occlusal rest. By using universal test machine, the numerical maximum value were recorded during the vertical load test of each FPDs after the bonding process treated by Maxcem which is resin cement. The failure process and its result of prosthesis were also observed. The maximum load was 7,295 N, 4,729 N, 2,190 N, 3,073 N from groups of resin bonded FPD, Two Key Bridge, Human Bridge without occlusal rest and Human Bridge with occlusal rest respectively. There was a statistical significance among the groups of resin bonded FPD, Two Key Bridge and Human Brides. However, there was no significant difference between Human Bridge without occlusal rest and Human Bridge with occlusal rest. Regarding the failure of prosthesis, the groups of Resin Bonded FPD and Two Key Bridge showed that one of the abutment teeth in the both side of retention part was highly failed earlier than the other one (83.2% and 66.6% respectively). While, Human Bridge without occlusal rest and Human Bridge with occlusal rest showed high percentage of failure in the abutment teeth in the both side of retention part at the same time (91.6% and 58.3% respectively). This study demonstrates that the group of Human Bridges has low resistance to the vertical loads of low invasive FPDs in comparison with the groups of resin bonded FPD and Two Key Bridge. Nevertheless, the maximum occlusal load of the restorative position, resistance to diverse restoration failure, amount of tooth reduction and patients' cooperation should be considered when they are applied in the clinic in order to choose an appropriate restoration for each patient.

Orthodontic protraction of the third molars to the posterior teeth missing area (구치 결손 환자에서 제3대구치의 교정적 활용)

  • Lee, Kang-gyu;Park, Je-Hyeok;Jeon, Jin;Kang, Jae-yoen;Kim, Jong Ghee;Jeon, Young-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.260-269
    • /
    • 2019
  • The prolonged neglect of the posterior teeth missing area may cause mesial drift, extrusion, unexpected movement of the adjacent teeth and alveolar bone loss with occlusion collapse. Therefore it is recommended to treat that area by the prosthesis as soon as possible after tooth missing. However, if orthodontic treatment is applied to move the remained teeth, it can create improved biomechanical dentoalveolar environment. The use of the third molars in teeth missing area provides advantages as optimizing of prosthesis size. However, crown shape, location, soundness of the third molar and possible of eruption failure should be considered. In this case report, two patients closed a second teeth missing site and reduced the size of the first and second teeth missing area for an implant by protraction of impacted third molars. This case reports the considerations for closing or reducing the posterior teeth space with protracting the third molars by comparing two patients.

Mandibular Implant-Supported Telescopic Overdenture using Gold Electroforming System : A Case Report (Gold Electroforming System을 이용한 하악 임플란트 지지 텔레스코프 피개의치)

  • Choi, Jee-Ha;Kim, Seung-Kyun;Yu, Byoung-Il;Ahn, Seung-Geun;Park, Ju-Mi;Song, Kwang-Yeob;Park, Charn-Woon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.193-201
    • /
    • 2008
  • In edentulous mandible, implant supported overdenture was considered as a first treatment option. In case of a implant supported telescopic overdenture, sufficient inter-arch space needs for arrangement of artificial teeth and attachment. Passive fit of the implant prosthesis is important factor for preventing mechanical failure. Gold Electroforming System is particularly useful to achieve a passive fit of telescopic attachment and results in precision marginal fit and the small thickness of the coping provides optimal space for narrow inter-arch space. This article presents that application of Gold Electroforming System can provide excellent esthetics and function on four-implant supported telescopic overdenture.

Influence of the implant abutment types and the dynamic loading on initial screw loosening

  • Kim, Eun-Sook;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.1
    • /
    • pp.21-28
    • /
    • 2013
  • PURPOSE. This study examined the effects of the abutment types and dynamic loading on the stability of implant prostheses with three types of implant abutments prepared using different fabrication methods by measuring removal torque both before and after dynamic loading. MATERIALS AND METHODS. Three groups of abutments were produced using different types of fabrication methods; stock abutment, gold cast abutment, and CAD/CAM custom abutment. A customized jig was fabricated to apply the load at $30^{\circ}$ to the long axis. The implant fixtures were fixed to the jig, and connected to the abutments with a 30 Ncm tightening torque. A sine curved dynamic load was applied for $10^5$ cycles between 25 and 250 N at 14 Hz. Removal torque before loading and after loading were evaluated. The SPSS was used for statistical analysis of the results. A Kruskal-Wallis test was performed to compare screw loosening between the abutment systems. A Wilcoxon signed-rank test was performed to compare screw loosening between before and after loading in each group (${\alpha}$=0.05). RESULTS. Removal torque value before loading and after loading was the highest in stock abutment, which was then followed by gold cast abutment and CAD/CAM custom abutment, but there were no significant differences. CONCLUSION. The abutment types did not have a significant influence on short term screw loosening. On the other hand, after $10^5$ cycles dynamic loading, CAD/CAM custom abutment affected the initial screw loosening, but stock abutment and gold cast abutment did not.

Evaluation of clinical status of fixed prosthesis (고정성 보철물의 임상적 상태에 대한 평가)

  • Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.99-107
    • /
    • 2009
  • Statement of problem: Restoring and replacing teeth with fixed prostheses commonly used in dental practice. Because of improper oral hygiene care and inaccurate laboratory procedure, complications of fixed prostheses were found in the mouth of patients. Although many efforts have been continually made to obtain the data of long term prognosis of fixed prostheses, it was difficult to do it. Purpose: The purpose of this study was to evaluate the clinical status of fixed prostheses. Material and methods: In order to assess the clinical status of fixed prostheses, a total of 161 individuals(aged 17-85, 99 women and 62 men with 1596 unit of fixed prostheses, and 1169 abutments) who first visited the Department of Prosthodontics, Pusan National University Hospital, between April to September, in 2007 were examined. Results and conclusion: The results of this study were as follows: 1. Length of service of fixed prostheses was $8.6{\pm}0.6$ years(mean), 10.0 years(median). 2. Location of fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in posterior region and in mandible where the failure rate was high in combination(P<.05). 3. Longevity of fixed prostheses made of metal was longest(mean: $13.0{\pm}9.3$, median: 14.0), gold, precious ceramic, non-precious ceramic trailing behind(P<.05). 4. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in Single-unit and the failure rate was high in over 3-unit(P<.05). 5. Condition of opposing dentition was found to have no statistically significant influence on longevity of fixed prostheses(P>.05). But, the success rate was high in natural dentition(P<.05). 6. Defective margin(28.2%), dental caries(23.0%), periodontal disease(19.3%), periapical disease(16.9%) were frequent complications. In 30.1% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

Complication and Failure Analysis of Fixed Restorations (고정성 보철물과 연관된 합병증과 실패에 관한 조사)

  • Yun, Mi-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.149-159
    • /
    • 2011
  • Restoring and replacing teeth with fixed prostheses commonly used in dental practice. Because of improper oral hygiene care and inaccurate laboratory procedure, complication of fixed prostheses was found in the mouth of patient. Although many efforts have been continually made to obtain the data of long term prognosis of fixed prostheses, it was difficult to do it. The purpose of this study was to evaluate the clinical status of fixed prostheses to improve the quality of dental care. In order to assess the clinical status of fixed prostheses, a total of 154 individuals (aged 22-82, 88 women and 66 men loaded with 578 unit of fixed prostheses, and 423 abutments) who visited the Department of Prosthodontics, Pusan National University Hospital, between January 2009 to December 2009 and removed old fixed prostheses were examined. The results of this study were as follows: 1. Length of service of fixed prostheses was $10.3{\pm}05.5$ years (mean), 10.0 years (median). 2. Location of fixed prostheses was found to have statistically significant influence on longevity of fixed prostheses (P<.05). The longevity of fixed prostheses was high in anterior-posterior combination region (mean:13.1, median:13.5) than anterior and posterior region. 3. Longevity of fixed prostheses made of metal was longest (mean:13.3, median:12.3). 4. Number of units in fixed prostheses was found to have no statistically significant influence on longevity of fixed prostheses (P>.05). 5. Condition of opposing dentition was found to have statistically significant influence on longevity of fixed prostheses (P>.05). The fixed prostheses lasted longest when opposed by complete denture (mean:17.1, median:19.7), removable partial denture, fixed prosthesis and natural dentition trailing behind (P<.05) 6. Periodontal disease (37.5%), dental caries (19.0%), defective margin (18.4%) were frequent complications. In 33.1% of the cases, abutment state after removing fixed prostheses was needed to be extracted.

Three-dimensional finite element analysis according to the insertion depth of an immediately loaded implant in the anterior maxilla (상악 전치부 즉시하중 임플란트의 식립 깊이에 따른 삼차원 유한요소 분석)

  • Park, Cheol-Woo;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of the insertion depth of an immediately loaded implant on the stress distribution of the surrounding bone and the micromovement of the implant using the three-dimensional finite element analysis. Materials and methods: A total of five bone models were constructed such that the implant platform was positioned at the levels of 0.00 mm, 0.25 mm, 0.50 mm, 0.75 mm, and 1.00 mm depth from the crest of the cortical bone. A frictional coefficient of 0.3 and the insertion torque of 35 Ncm were simulated on the interface between the implant and surrounding bone. A static load of 178 N was applied to the provisional prosthesis with a vertical load in the axial direction and an oblique load at $30^{\circ}$ with respect to the central axis of the implant, then a finite element analysis was performed. Results: The implant insertion depth significantly affected the stress distribution on the surrounding bone. The largest micromovement value of the implant was $39.34{\mu}m$. The oblique load contributed significantly to the stress distribution and micromovement in comparison to the vertical load. Conclusion: Increasing the implant insertion depth was advantageous in dispersing the concentrated stress in the cortical bone and did not significantly affect the micromovement associated with early osseointegration failure.

A multicenter clinical study of installed US II Plus/GS II Osstem implants after bone graft (골 이식술 후 Osstem Implant (US II Plus/GS II)의 다기관 임상연구)

  • Chung, Kwang;Oh, Chul-Jung;Ha, Ji-Won;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun;Kim, Su-Gwan;Kim, Young-Kyun;Kim, Woo-Cheol
    • The Journal of the Korean dental association
    • /
    • v.50 no.12
    • /
    • pp.743-754
    • /
    • 2012
  • urpose : The purpose of this study was to evaluate the US II plus/GS II Osstem$^{(R)}$ implants through the study for the clinical success rate during the installation of the Osstem¢Á implants after bone graft. Materials and Methods : This study was researched in the 4 medical institutions: Chonnam National University, Chosun University, Bundang Seoul National University Hospital, and FM dental clinic from May, 2002 to September, 2009. Based on the total number of 60 patients whose treatment was the installation of the US II plus/GS II Osstem¢Á implants after bone graft, we evaluated success rate of implants. We analysis the distribution of patient's age and gender, edentulous area, bone type, fixture length and diameter, installation and loading time, donor site, bone graft material and method, antagonistic teeth, and survival and success rate. From these analyses we got the following results. Results : 1. In this study, the total number of patients who have been installed with US II plus implant was 27, and total of 52 implants were installed. The average age was 38.9, with 16 male, and 11 female patients. 2. The total number of patients who have been installed with GS II implant was 33, and total of 54 implants were installed. The average age was 49.7, with 24 male, and 9 female patients. 3. As for bone graft method, either autogenous bone or a mix of autogenous and heterogenous bone was used(88.4%) for US II plus. Chin, iliac, and Maxillary tuberosity were the donor sites for autogenous bone graft, and onlay method of bone graft was performed. 4. Allogenic bone or a mix of autogenous and heterogenous bone was used(77.8%) for GS II. Chin, ramus, and tibia were the donor sites for autogenous bone graft, and GBR method of bone graft was performed. 5. The duration from the installation of implants to setting of final prosthesis was average of 16 months and 10 months for US II plus and GS II respectively. Also, the final follow up period was average of 31 months and 28 months respectively. During this period, one GS II implant was removed from 1 patient due to failure of early osteointegration. 6. The survival rates were 100% and 98.1%, and success rates were 94.2% and 94.4% for US II plus and GS II implant respectively. Conclusion : On the evaluation of our clinical study, both US II plus and GS II Osstem¢Á implants showed the excellent clinical results after bone graft.