• Title/Summary/Keyword: Dental prosthesis failure

Search Result 63, Processing Time 0.021 seconds

A method of contouring occlusal surface for reduction of implant overload (Implant overload 감소를 위한 교합면 형성 방법)

  • Lee, Byung-Woo;Park, Chan-Jin;Cho, Lee-Ra;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.19 no.2
    • /
    • pp.105-108
    • /
    • 2003
  • After stage-two surgery, the highest incidence of failure has been attributed to implant overload. However, the biomechanical factors cited inthe literature that contribute to implant overload, such as bone type, cuspal inclination, horizontal offset, maxillary compared to mandibular arch, the inclusion of natural teeth within the prosthesis, and occlusal harmony are superimposed on physiologic variations. Following two cases, including reduction of cuspal inclination and usage of modified incisal pin, showed a method of contouring occlusal surface for reduction of unpreditable implant overload.

Speech treatment of velopharyngeal insufficiency using biofeedback technique with NM II; A case report (Nasometer 활용 바이오피드백 기법을 이용한 비인강폐쇄전환자의 치험 사례)

  • Yang Ji-Hyung;Choi Jin-Young
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.8 no.1
    • /
    • pp.45-52
    • /
    • 2005
  • Velopharyngeal Insufficiency(VPI); the failure of velum, the lateral wall and the posterior pharyngeal wall to separate the nasal cavity from pharyngeal cavity during speech, can be caused by congenital conditions include cleft palate, submucous cleft palate and congenital palatal insufficiency. Speech problems of VPI are characterized by hypernasality, nasal air emission, increased nasal air flow and decreased intelligibility. These speech problems of VPI can be treated with the surgical procedure, the application of temporary prosthesis and speech therapy. Biofeedback technique with Nasometer is a speech treatment method of VPI that commonly used as one component of a comprehensive procedure for improvement of speech in patients with VPI. In this article describes a case of VPI treated by biofeedback technique with Nasometer; which showed satisfactory result in nasalance and formant analysis after the speech therapy during 9 months.

  • PDF

Clinical considerations for appropriate occlusion of implant restorations (임플란트 보철 교합의 임상적 고려 사항)

  • Park, Young-Bum
    • The Journal of the Korean dental association
    • /
    • v.53 no.6
    • /
    • pp.418-426
    • /
    • 2015
  • The appropriate occlusion is one of the most important factors for the long-term success of implant and its restorations. The purpose of this review is to investigate and define occlusal considerations to reduce failure of implant prostheses. The physiological movement of implants is markedly lower than that of natural teeth and they also lack in occlusal sensitivity. Proper occlusal pattern may be assigned to compensate for the biological disadvantages and occlusal contacts must be formed where the cantilever effect is minimized. Moreover, the long-term success of implants after osseointegration can be assured by reducing early occlusal loading to avoid implant overloading and selecting appropriate occlusion material. Occlusal overload was brought by the number and location of occlusal contacts, which are under the clinician's control. The concept of implant occlusion is based on the concepts derived from traditional prosthetics. Moreover, there are few evidence on the concept or design of implant occlusion. Several occlusal design was recommended for implant prosthesis. Mutually protected occlusion, group function occlusion and bilateral balance occlusion was recommended for the specific types of implant restorations. This article reviews proper design of occlusion for implant restoration and offers occlusion strategy clinically.

A retrospective randomized study of success rates according to abutment selection in DENTIS submerged implant with an internal hex connection (DENTIS 내부연결형 서브머지드 임플란트에서 지대주 선택에 따른 성공률의 후향적 연구)

  • Kim, Eun-Hee;Lee, Joeng-Eun;Hwang, Hee-Seong;Kim, Chul-Hoon;Kim, Jung-Han;Kim, Bok-Joo
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.605-614
    • /
    • 2018
  • PURPOSE. The purpose of this study is to determine the efficacy of the DENTIS submerged-type implant with an internal hex connection and to build corresponding abutment-selection criteria. MATERIAL AND METHODS. A total of 204 patients received submerged implant fixtures with an internal hex connection at the Dong-A University Hospital Dental clinic in Busan from January 2013 and May 2016. Three specific abutments, UCLA abutments, customized abutments, ready-made abutments, were randomly selected. Implant success was defined as the basis of the International Congress of Oral Implantologists(ICOI, 2007) criteria. The relationship between the implant success rate and the abutment factor was analyzed using the Kruskal-Wallis test(P<.05). RESULTS. A total of 508 implants were placed in 204 patients. After a mean observation period of 38.6 months, 493 out of 508 implants were in normal function, yielding an overall success rate of 97.05%. A total of 15 implants failed: 10 in the maxillary molar area, 4 in the mandibular molar area, and 1 in the mandibular incisal area. All of the implant failures occurred in a single-implant prosthesis, especially high in the maxillary molar area. The Kruskal-Wallis analysis showed that abutment selection has no significant correlation with implant failure(P>.05). CONCLUSION. DENTIS submerged implants with an internal hex connection showed predictable results with a success rate of 97.05%. It is no influence on the success rate in the selection of submerged implant abutment with an internal hex connection.

  • PDF

Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.5
    • /
    • pp.325-332
    • /
    • 2014
  • PURPOSE. The aim of this review was to analyze the evaluation criteria on mandibular implant overdentures through a systematic review and suggest standardized evaluation criteria. MATERIALS AND METHODS. A systematic literature search was conducted by PubMed search strategy and hand-searching of relevant journals from included studies considering inclusion and exclusion criteria. Randomized clinical trials (RCT) and clinical trial studies comparing attachment systems on mandibular implant overdentures until December, 2011 were selected. Twenty nine studies were finally selected and the data about evaluation methods were collected. RESULTS. Evaluation criteria could be classified into 4 groups (implant survival, peri-implant tissue evaluation, prosthetic evaluation, and patient satisfaction). Among 29 studies, 21 studies presented implant survival rate, while any studies reporting implant failure did not present cumulative implant survival rate. Seventeen studies evaluating peri-implant tissue status presented following items as evaluation criteria; marginal bone level (14), plaque Index (13), probing depth (8), bleeding index (8), attachment gingiva level (8), gingival index (6), amount of keratinized gingiva (1). Eighteen studies evaluating prosthetic maintenance and complication also presented following items as evaluation criteria; loose matrix (17), female detachment (15), denture fracture (15), denture relining (14), abutment fracture (14), abutment screw loosening (11), and occlusal adjustment (9). Atypical questionnaire (9), Visual analog scales (VAS) (4), and Oral Health Impact Profile (OHIP) (1) were used as the format of criteria to evaluate patients satisfaction in 14 studies. CONCLUSION. For evaluation of implant overdenture, it is necessary to include cumulative survival rate for implant evaluation. It is suggested that peri-implant tissue evaluation criteria include marginal bone level, plaque index, bleeding index, probing depth, and attached gingiva level. It is also suggested that prosthetic evaluation criteria include loose matrix, female detachment, denture fracture, denture relining, abutment fracture, abutment screw loosening, and occlusal adjustment. Finally standardized criteria like OHIP-EDENT or VAS are required for patient satisfaction.

Effect of connector configuration on the fracture load in conventional and translucent zirconia three-unit fixed dental prostheses

  • Chonticha Subsomboon;Somchai Urapepon
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.4
    • /
    • pp.171-178
    • /
    • 2023
  • PURPOSE. The purpose of this study was to determine the effect of the connector configuration on the fracture load in conventional and translucent zirconia of three-unit fixed dental prostheses (FDPs). MATERIALS AND METHODS. Six different three-unit FDPs were prepared (n = 6) from three types of zirconia (3Y-TZP (Katana ML®), 4Y-TZP (Katana STML®), and 5Y-TZP (Katana UTML®)) in combination with two connector configurations (4 × 2.25, 3 × 3 mm). The CoCr master models were scanned, and the FDPs were designed and fabricated using CAD-CAM. The FDPs were cemented on the metal model and then loaded with a UTM at a crosshead speed of 1 mm/min until failure. Two-way ANOVA and Tukey's test were used for statistical analysis (α = .05). RESULTS. Fracture loads of 3Y-TZP (2740.6 ± 469.2 and 2718.7 ± 339.0 N for size 4 × 2.25 mm and 3 × 3 mm, respectively) were significantly higher than those of 4Y-TZP (1868.3 ± 281.6 and 1663.6 ± 372.7 N, respectively) and 5Y-TZP (1588.0 ± 255.0 and 1559.1 ± 110.0 N, respectively) (P < .05). No significant difference was found between fracture loads of 4Y-TZP and 5Y-TZP (P > .05). The connector configuration within 9 mm2 was found to have no effect on the fracture loads on all three types of zirconia (P > .05). CONCLUSION. Fracture loads of three-unit FDPs were affected by the type of zirconia. The fracture loads of conventional zirconia were higher than those of translucent zirconia. However, it was not affected by the connector configuration when the connector had a cross-sectional area of 9 mm2.

The effects of local factors on the survival of dental implants: A 19 year retrospective study (임플란트의 생존율에 영향을 미치는 국소적 인자에 대한 19년간의 후향적 연구)

  • Kim, Sung-Hoi;Kim, Sun-Jai;Lee, Keun-Woo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.28-40
    • /
    • 2010
  • Purpose: The aim of this retrospective study was to provide long-term data about the correlation between multifactorial local factors and the survival of implants. Material and methods: During 19 years (1991 to 2009), 2796 implants were placed in 879 patients. From dental charts and radiographs, the following data were collected: patient's age at implant placement, gender, implant system, surface, length, diameter, location of implant placement, bone quality, primary stability, type of prosthesis. The correlations between these data and implant survival were analyzed. Statistical analysis was performed using Kaplan-Meier survival analysis, Chi-square test, odds ratio. Results: 1. Among the 2796 implants, 150 implants failed that resulted in a cumulative survival rate of 94.64%. The cumulative survival rate of smooth surface implants (91.76%) was lower than rough surface implants (96.02%). 2. Anatomic location, implant surface, diameter of smooth surface implant, primary stability, type of prosthesis, patient's age and gender were significantly associated with implant survival (P < .05). 3. No significant difference in implant survival was found in relation to the following factors: implant length, bone quality, diameter of rough surface implants and type of rough surface according to implant manufacturer (P < .05). Conclusions: Local factors such as anatomic location, implant surface, diameter of smooth surface implant, primary stability and type of prosthesis have a significant effect on implant survival.

An 8-year survival rate of immediate implants: retrospective study (발치후 즉시 임플란트의 8년 누적 생존율에 대한 후향적 연구)

  • Ko, Seung-Hee;Chang, Yun-Young;Um, Yoo-Jung;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • The Journal of the Korean dental association
    • /
    • v.47 no.11
    • /
    • pp.758-768
    • /
    • 2009
  • Purpose : Schulte introduced immediate implant cases in 1970s, since then many patients have been treated by immediate implants. The aim of this study was to evaluate the cumulative survival rate of immediate implant and to analyze various factors associated with survival of immediate implant in a 8-year period retrospectively. Materials and methods : From May, 2000 to October, 2007, 77 implants were placed in 63 patients immediately after tooth extraction at Department of Periodontology, Yonsei University Hospital. The implant survival rate was analyzed using a life-table analysis. After delivery of prosthesis, along 1 year of observation period, all implants were evaluated clinically and radiographically. Results : Among 77 implants, 59 were placed in maxilla and 18 in mandible. The most common site of the implantation was Mx anterior (65%). The overall survival rate was 94.8% over a mean follow-up period of $44.2{\pm}21$ months and the 8-year cumulative survival rate was 94.6%. Failure occurred in 4 implants, all of which were due to early failures. None of the following factors were significantly associated with the survival of immediate implants: advanced surgical technique including bone graft and guided bone regeneration, the types of implants, causes of tooth loss, and types of prosthesis. Conclusion : On the basis of 8-year life time analysis, immediate implant placement can be considered a safe and predictable treatment mordality.

  • PDF

Comparative Study of the Early Loading of Resorbable Blasting Media and Sandblasting with Large-grit and Acid-etching Surface Implants: A Retrospective Cohort Study

  • Kim, Sung-Beom;Kim, Young-Kyun;Kim, Su-Gwan;Oh, Ji-Su;Kim, Byung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.6
    • /
    • pp.247-252
    • /
    • 2014
  • Purpose: This study compares the prognosis (the survival rate and marginal bone loss) of resorbable blasting media (RBM) surface implants and sandblasting with large-grit and acid-etching (SLA) surface implants in the early loading. Methods: This study targeted 123 patients treated by implants installation from January 2008 to March 2010. The loading was initiated in the maxilla within three to four months and in the mandible within one to two months. The types of restoration were single crown and fixed partial prosthesis. Those functioned over one year. The implants were classified by the surface of implants as Group 1: RBM surface (GS III; OSSTEM, Busan, Korea) and, Group 2: SLA surface (Superline; Dentium, Seoul, Korea). The groups were categorized by maxilla and mandible and compared by survival rate, marginal bone loss through clinical records evaluation, and radiographic measurements. Results: The marginal bone loss in the maxilla was $0.14{\pm}0.34mm$ (Group 1) and $0.30{\pm}0.37mm$ (Group 2), a statistically significant difference (P<0.05). In the mandible those were $0.28{\pm}0.54mm$ (Group 1) and $0.20{\pm}0.33mm$ (Group 2), not significant (P>0.05). There was no significant difference of marginal bone loss between maxilla and mandible by groups. During observation there was no implant failure, a survival rate of 100%. Conclusion: Both surfaces showed an excellent survival rate, and the marginal bone loss was not substantial.

The study on the survival rates and crestal bone changes around the implants (임플란트 주위 골변화와 생존율에 대한 연구)

  • Choi, Hyun-Suk;Chung, Hyun-Ju;Kim, Ok-Su;Kim, Young-Jun
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.2
    • /
    • pp.303-315
    • /
    • 2004
  • The success and failure of dental implants depends on various factors such as patient's systemic status, quantity and quality of surrounding bone, presence or absence of marginal infection and mechanical loading condition. The measurement of crestal bone changes around the implants is implemental to evaluate the success and long-term prognosis of the implant. This study was to evaluate the cumulative survival rate of the implants which had been placed in the Department of Periodontics, Chonnam National University Hospital between 1992 and 2003, and to observe the crestal bone loss around the implants which had at least 2 consecutive periapical radiographs after connecting the transmucosal abutment. The radiographs were scanned and digitalized, and the crestal bone levels on the mesial and distal surface of implants were measured using Image analyzer (Image Pro Plus, Media Cybernetics, USA), immediately after implant placement, at 2nd surgery, and 3 months, 6 months, 1 year, and every year thereafter. Any bone loss was not observed during the period between the 1stand 2nd surgery, and the bone loss was 0.86 ${\pm}$ 0.92 mm for the first year of loading after connecting the transmucosal abutment. After 1 year of loading, annual bone loss was 0.1 ${\pm}$ 0.27 mm, and total bone loss was 0.90 ${\pm}$ 0.80 mm (during the average follow-up periods of 22.5 ${\pm}$ 25.6 Mos), The implant, with smooth surface, in the mandible, and with the fixed bridge prosthesis showed greater bone loss, compared to those, with the rough surface, in the maxilla and with single crown. In systemically diseased patients (including DM or osteoporosis), the greater bone loss was observed. The cumulative survival rate among 432 implants was 94.10% for 7 years. Among 15 failed implants, 9 implants were removed due to mobility from disintegration of bone-implant interface. From this results, crestal bone loss around the implants were greatest during 1 year after transmucosal abutment connection, and various factors could affect peri-implant bone loss. To prevent and predict the bone loss around the implants and improve the prognosis, further comprehensive maintenance and follow-up schedules are required.