• Title/Summary/Keyword: Dental prosthesis failure

Search Result 63, Processing Time 0.025 seconds

A study on the difference of movement between Semi adjustable articulator and Oral in vivo (반조절성교합기와 구강에서의 운동 오차에 대한 비교 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.1
    • /
    • pp.53-59
    • /
    • 2006
  • The movement range on the semi adjustable articulator and the movement range in an oral were measured. And then I studied to analyze the gap. I got wax records by the movement on the semi adjustable articulator, the movement in an oral. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the semi adjustable articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the semi adjustable articulator although it did not finish in an oral. When the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the semi adjustable articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are appeared to be straight. Therefore dental prosthesisses were made by the semi adjustable articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the semi adjustable articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the semi adjustable articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The difference in the range of movement is considered as the gap that is made because the movement only can be occurred as straight in the semi adjustable articulator. 3. When the dental technician understand mandibular movement and articulator deficiencies, they can attain proficiency in use of the articulator and reduce the gap.

  • PDF

A 10-year retrospective study on the risk factors affecting the success rate of internal connection implants after prosthetic restoration (내부연결 임플란트의 보철 수복 후 성공률에 미치는 위험요소에 관한 10년간의 후향적 연구)

  • Seoin Lee;Min-Jeong Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.113-124
    • /
    • 2023
  • Purpose. The purpose of this study is to help increase the success rate by analyzing the types and characteristics of implant prosthesis and the survival rate. Materials and methods. Among implants placed between 2011 and 2020 at Sanbon Dental Hospital, College of Dentistry, Wonkwang University, a case restored by a prosthetic surgeon was investigated for the characteristics and correlation of failure. The causes of failure were classified as failure of osseointegration, peri-implantitis, fixture fracture, abutment fracture, screw fracture, screw loosening, prosthesis fracture, and loss of prosthesis retention. Prosthetic method, cantilever presence, placement location, etc. were analyzed for their correlation with implant failure. Results analysis was derived through Chi-square test and Kaplan-Meier survival analysis using SPSS ver 25.0 (IBM, Chicago, IL, USA). Results. A total of 2587 implants were placed, of which 1141 implants were restored with Single Crown and 1446 implants with Fixed Partial Denture, and the cumulative survival rate was 88.1%. The success rate of SC was 86.2% (984) and the success rate of FPD was 89.6% (1295), showing statistically significant differences, among which factors that had significant differences were abutment fracture, screw fracture, and screw loosening (P < .05). Conclusion. As a result of the 10-year follow-up, more failures occurred due to biomechanical factors than biological factors. Further studies on the success of implants will be needed in the future.

An Experimental study on the gap of movement by the hinge articulator (단순교합기에 의한 하악운동의 오차에 대한 실험적 연구)

  • Moon, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.111-118
    • /
    • 2003
  • I measured the movement range on the hinge articulator and the movement range in an oral. And then I studied to analyze the gap. I got wax records by the movement on the hinge articulator, the movement in an oral and the movement on the hand articulating. I measured the distance of the cusp tips that are close to the mesial direction and the distal direction, the buccal direction and the lingual direction then I compared gaps. As I saw results on data, I knew that the hinge articulator represented the range of mandibular movement restrictively. I could find the decisive contradiction that the sliding movement finished on the hinge articulator although it did not finish in an oral. If the sliding movement does not reappear exactly, it brings a fatal failure to the dental prosthesis. In addition it is impossible that the hinge articulator restores the movement in an oral because the lateral condyle inclination and the horizontal condyle inclination are fixed previously. Therefore dental prosthesisses were made by the hinge articulator, they will interfere with a mastication. I have obtained the following results; 1. The distance of sliding movement on the hinge articulator showed shorter than the distance of sliding movement in oral. This means the increase of cusp inclination of the dental prosthesis that was made on the hinge articulator. Therefore, when the lateral movement occurs in oral, there is a possibility to become the premature as the increase of cusp inclination. 2. The results that were impressed records in oral and impressed records on the hand articulating have many congruities. I think that the simple crown etc. that were made by the hand articulating method except the long span bridge and the free end case that can not measure the vertical dimension exactly can represent similarly the mandibular movement. 3. If we want to represent the mandibular movement similarly, we have to use the articulator that can adjust the horizontal condyle inclination and the lateral condyle inclination at least.

  • PDF

Prognosis following dental implant treatment under general anesthesia in patients with special needs

  • Kim, Il-hyung;Kuk, Tae Seong;Park, Sang Yoon;Choi, Yong-suk;Kim, Hyun Jeong;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.17 no.3
    • /
    • pp.205-213
    • /
    • 2017
  • Background: This study retrospectively investigated outcomes following dental implantation in patients with special needs who required general anesthesia to enable treatment. Method: Patients underwent implant treatment under general anesthesia at the Clinic for the Disabled in Seoul National University Dental Hospital between January 2004 and June 2017. The study analyzed medical records and radiographs. Implant survival rates were calculated by applying criteria for success or failure. Results: Of 19 patients in the study, 8 were males and 11 were females, with a mean age of 32.9 years. The patients included 11 with mental retardation, 3 with autism, 2 with cerebral palsy, 2 with schizophrenia, and 1 with a brain disorder; 2 patients also had seizure disorders. All were incapable of oral self-care due to serious cognitive impairment and could not cooperate with normal dental treatment. A total of 27 rounds of general anesthesia and 1 round of intravenous sedation were performed for implant surgery. Implant placement was performed in 3 patients whose prosthesis records could not be found, while 3 other patients had less than 1 year of follow-up after prosthetic treatment. When the criteria for implant success or failure were applied in 13 remaining patients, 3 implant failures occurred in 59 total treatments. The cumulative survival rate of implants over an average of 43.3 months (15-116 months) was 94.9%. Conclusion: For patients with severe cognitive impairment who are incapable of oral self-care, implant treatment under general anesthesia showed a favorable prognosis.

Effects of implant alignment and load direction on mandibular bone and implant: finite element analysis (임플란트 배열과 하중 방향이 임플란트와 치조골에 미치는 유한요소 응력분석)

  • Chung, Hyunju;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sang-Won;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.176-182
    • /
    • 2020
  • Purpose: To evaluate the effects of load direction, number of implants, and alignment of implant position on stress distribution in implant, prosthesis, and bone tissue. Materials and Methods: Four 3D models were made to simulate posterior mandible bone block: two implants and 3-unit fixed dental prosthesis (FDP) with a pontic in the center (model M1), two implants and 3-unit FDP with a cantilever pontic at one end (model M2), FDP supported by three implants with straight line placement (model M3) and FDP supported by three implants with staggered implant configuration (model M4). The applied force was 120 N axially or 120 N obliquely. Results: Peak von Mises stresses caused by oblique occlusal force were 3.4 to 5.1 times higher in the implant and 3.5 to 8.3 times higher in the alveolar bone than those stresses caused by axial occlusal force. In model M2, the connector area of the distal cantilever in the prosthesis generated the highest von Mises stresses among all models. With the design of a large number of implants, low stresses were generated. When three implants were placed, there were no significant differences in the magnitude of stress between staggered arrangement and straight arrangement. Conclusion: The effect of staggering alignment on implant stress was negligible. However, the number of implants had a significant effect on stress magnitude.

The fabrication of abutment crowns for existing removable partial denture using CAD/CAM: A clinical report (CAD/CAM을 이용하여 기존 국소의치에 맞는 지대치 보철물 제작 증례)

  • Chae, Min-Jeong;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.490-494
    • /
    • 2019
  • Abutment teeth supporting removable partial denture could be faced a number of problems including development of dental caries. If the existing removable partial denture is in clinically acceptable state and the patient does not want to replace the existing removable partial denture, then a new prosthesis for abutment teeth need to be made. The procedure of fabricating a new prosthesis of abutment teeth for existing removable partial denture is complicate and technically challenging. To fabricate the abutment crown, the original cast of patient obtained before any complication to the abutment teeth is required. The original cast should also contain teeth other than the abutment teeth as a reference point. Once the cast is prepared, CAD/CAM could be used to produce retrofitting prosthesis effortlessly and efficiently. This clinical report presents fabricating a crown to fit existing removable partial denture using CAD/CAM for a patient with post and core failure and dislodged prosthesis. The prosthesis had high stability with minimum adjustment yielding satisfying result.

Clinical Study on the Survival Rate and Marginal Bone Resorption of Short Implants (짧은 임플란트의 생존율과 변연골 흡수량에 관한 임상적 연구)

  • Myung, Tae-Soo;Jung, Seung-Hyun;Kim, Tae-Young;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.1
    • /
    • pp.1-13
    • /
    • 2012
  • Short implants are used in parts which have anatomical structures like maxillary sinus, inferior alveolar nerve and limited alveolar height due to severe alveolar bone resorption. In these case, there are no need of additional bone augmentation so there are advantages like reduced entire treatment time, reduced patient's discomfort and protection of important anatomical structures. The aim of this study is, in implants whose length is less than 10mm, to analyze the impact of implant length, diameter, location of implant placement, presence of bone graft, presence of prosthesis splinting on survival rates and marginal bone resorption. The samples used in this study were 227 implants, less than 10mm, placed in 137 patients in Wonkwang university dental hospital implant center. From dental charts the information about implant length, diameter, location of implant placement, presence of bone graft, presence of prosthesis splinting were obtained. Emago advanced v5.6(Oral diagnostic systems, Amsterdam, The Netherlands)program was used to measure the amount of marginal bone resorption. Out of total 227 implants, resulting in 96.5 % of survival rate. There was a tendency toward higher failure rates for the maxilla and bone graft site. No significant difference in marginal bone resorption was found associated with length of implants(p>0.05) and neither with the diameter of implants. Among the risk factors examined, more failure rates of short implants can be attributed to poor bone quality in the maxilla and presence of bone graft. At implants under 10mm, length, diameter, location of implant placement, bone graft and splinting of prosthesis didn't affect marginal bone loss.

Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

  • Lanata-Flores, Antonio Gabriel;Sigua-Rodriguez, Eder Alberto;Goulart, Douglas Rangel;Bomfim-Azevedo, Veber Luiz;Olate, Sergio;de Albergaria-Barbosa, Jose Ricardo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.6
    • /
    • pp.352-357
    • /
    • 2016
  • Objectives: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. Materials and Methods: Twelve models of acrylic resin were used with implants placed 20 mm from each other and separated into three groups: (1) bar-clip (Sistema INP, São Paulo, Brazil), (2) ball/O-ring (Sistema INP), and (3) magnet (Metalmag, São Paulo, Brazil), with four samples in each group. Each sample underwent a mechanical cycling removal and insertion test (f=0.5 Hz) to determine the torque and the detorque values of the retention screws. A servo-hydraulic MTS machine (810-Flextest 40; MTS Systems, Eden Prairie, MN, USA) was used to perform the cycling with 2.5 mm and a displacement of 10 mm/s. The screws of the retention systems received an initial torque of 30 Ncm and the torque values required for loosening the screw values were obtained in three cycles (1,080, 2,160, and 3,240). The screws were retorqued to 30 Ncm before each new cycle. Results: The sample was composed of 24 screws grouped as follows: bar-clip (n=8), ball/O-ring (n=8), and magnet (n=8). There were significant differences between the groups, with greater detorque values observed in the ball/O-ring group when compared to the bar-clip and magnet groups for the first cycle. However, the detorque value was greater in the bar-clip group for the second cycle. Conclusion: The results of this study indicate that all prosthetic screws will loosen slightly after an initial tightening torque, also the bar-clip retention system demonstrated greater loosening of the screws when compared with ball/O-ring and magnet retention systems.

Study about shear bond strength of zirconia core used in dental prosthesis (치과 보철물에 사용되는 지르코니아 코어의 전단결합강도에 관한 연구)

  • Sim, Ji-Young;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.299-306
    • /
    • 2011
  • Purpose: This study aimed to investigate the shear bond strength by manufacturing the veneering porcelain on the IPS e.max $ZirCAD^{(R)}$ zirconia core, using the layering technique and heat-pressing technique, and to evaluate the clinical stability by comparing to the conventional metal ceramic system. Methods: The Schmitz-Schulmeyer test method was used to evaluate the core-veneer shear bond strength of zirconia core ceramic(IPS e.max $ZirCAD^{(R)}$) and their manufacture recommended two veneering ceramic systems(IPS e.max $ceram^{(R)}$, IPS e. max $ZirPress^{(R)}$). A metal ceramic system(Bellabond $plus^{(R)}$, VITA $VM13^{(R)}$) was used as a control group for the two all ceramic system test groups. The maximum loading and shear bond strength was measured. The average shear strength(MPa) was analyzed with the one-way ANOVA and the Tukey's test(${\alpha}$=.05). The fracture specimens were examined using Microscope to determine the failure pattern. Results: The mean shear bond strengths(SD) in MPa were MBSB control 43.62(2.13); ZBSB 18.65(1.76); ZPSB 18.89(1.54). The shear strengths of the zirconia cores were not significantly different(P>.05). Microscope examination showed that zirconia specimens presented mixed failure, and base metal alloy specimens showed adhesive failure. Conclusion: There was no siginificant different between the layering technique and the heat pressing technique in the veneering methods on the zirconia cores. None of the zirconia core and veneering ceramics could attain the high bond strength values of the metal ceramic combination.

APPLICATION OF CAD/CAM FOR ORAL REHABILITATION IN A PATIENT WITH DOWN SYNDROME (CAD/CAM을 이용한 다운 증후군 환자의 구강 재건)

  • Chung, Hyunjin;Shim, Joon-Sung;Choi, Byung-Jai;Lee, Jae-Ho
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.13 no.2
    • /
    • pp.95-98
    • /
    • 2017
  • Due to hypodontia, poor oral hygiene, and significantly more prevalent periodontal disease, patients with Down syndrome show higher incidence of edentulism. Oral rehabilitation of such patients is imperative but challenging as high rates of prosthesis failure are reported due to malocclusion, high masticatory force, and parafunctional habits. As CAD/CAM(Computer-Aided Design and Computer Aided Manufacturing) is the recent trend in prosthodontics, this report discusses the application of CAD/CAM in a Down syndrome patient. A 25-year-old patient with Down syndrome was presented to the Department of Pediatric Dentistry, Yonsei University Dental Hospital for oral examination. 5 maxillary teeth were missing, 3 were fully impacted, and 4 had grade III mobility. The patient underwent general anesthesia for extraction of impacted and mobile teeth, implant surgery, and final impression for prosthesis. Afterwards, CAD/CAM was used to design and manufacture a 10-unit zirconia bridge. However the bridge was fractured after 18 months due to the patient's bruxism and high masticatory force. Final impression taking, bite registration, cast fabrication, cast scanning, and prosthesis designing were not needed as CAD/CAM data remained. Previous CAD/CAM design was used to remanufacture the zirconia bridge. Down syndrome patients have malocclusion, high masticatory force, and parafunctional habits which increase the possibility of prosthesis fracture. CAD/CAM is beneficial for Down syndrome patients as previous digital records can be utilized for prosthesis repair or remake. In detail, application of CAD/CAM in remanufacturing decreases patient's discomfort of impression taking, shortens and simplifies dental laboratory procedures, and reduces clinician's effort of taking detailed final impressions or accurate bite registration. In conclusion, oral rehabilitation using CAD/CAM provides not only satisfactory levels of comfort, stability, and esthetics, but also easier repair or remake compared to conventional prostheses.