• 제목/요약/키워드: Dental noise reduction

검색결과 21건 처리시간 0.023초

치과위생사의 치과 내 소음인식도와 청력관련 특성 및 업무와의 관련성 (The relationship between noise awareness, hearing ability, and dental hygiene performance in dental hygienists)

  • 박경화;김효진
    • 한국치위생학회지
    • /
    • 제15권1호
    • /
    • pp.11-17
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate the relationship between noise awareness, hearing ability, and dental hygiene performance in dental hygienists. Methods: The subjects were 234 dental hygienists in Seoul, Gyeonggi-do, and Incheon. The questionnaire consisted of 3 questions of general characteristics of the subjects, 1 question of noise awareness, 3 questions of hearing ability, 5 questions of dental hygiene performance, 1 question of noise reduction necessity, and 2 questions of noise control. Noise awareness, dental hygiene performance, and noise reduction necessity were measured by Likert 5 scale. Cronbach's alpha was 0.825 in dental hygiene performance reliability. Results: There was a significant difference in noise recognition by age(p<0.01) and working career(p<0.05). Those who pumped up the higher TV volume accounted for 31.6% and 3.0% had hearing impairment in the regular health checkup. 3.4% of the respondents complained of hearing loss, ear fluid, and equilibrium problem diagnosed by the doctors. The relationship between the type of workplace environment and task performance showed a significant difference. Those who work in the dental hospitals had high score of 3.43, while those who work in dental clinics had 3.20(p<0.05). The increased level of noise recognition affected the task performance and it is necessary to reduce the noise level. More try must be focused on the noise exposure prevention. Conclusions: In order to reduce the problems due to noise and improve their quality of life, it is necessary to change the noise recognition in the work place.

치과 의료장비의 소음 수준 평가 (The Noise Level Assessment of Dental Equipment)

  • 이정숙;한예슬;조영식
    • 치위생과학회지
    • /
    • 제15권5호
    • /
    • pp.603-611
    • /
    • 2015
  • 치과 진료실에서 발생하는 소음원에 대한 소음의 특성을 파악하고 그에 따른 피해 가능성을 알아보기 위해 휴대용 소음기로 측정하여 검토한 결과 다음과 같은 결론을 얻었다. 치과용 의료기기 소음측정 결과 단독측정에서는 고속 핸드피스가 가장 높았으며, 초음파 스케일러, 저속 핸드피스 순서로 낮게 나타났다. 단독측정 시 평균 소음도는 58~66 dB(A)를 보였으며, 복합측정 시 평균 소음도는 62~71 dB(A)를 보였다. 진료실 형태에 따른 개방형과 개실형의 소음측정 결과 개방형 진료실에서의 소음이 평균 1.9~3.2 dB(A) 더 높게 나타났다. 비진료 시와 진료 시의 소음측정 결과 초음파 스케일러와 고속 핸드피스의 소음에서 통계적으로 유의한 차이가 있었다. 초음파 스케일러와 high volume aspirator을 함께 사용하였을 때 가장 높은 소음도를 보였으며, 진료 시 75.5 dB(A)로 비진료 시와 3.5 dB(A)의 소음차를 보이며 더 높게 나타났다. NR 곡선으로 진료 시 가장 높은 소음도를 보인 치석제거를 평가해본 결과 치석제거 시 NR-73~78로 ISO 소음기준중 일반작업장의 소음기준을 초과하는 수준이며 8 kHz의 고주파에서 피크치를 나타냈다. 진료 시 거리에 따른 소음을 측정한 결과 작업자와 가까운 30 cm 거리에서의 소음이 100 cm 거리에서의 소음보다 높은 패턴을 보였으며, 30 cm 거리에서 대상 치과 의료기기에서 발생하는 소음레벨은 79.8~80.6 dB(A)으로 장시간 폭로 시 청력 손실을 초래할 수 있는 수준이다. 두 거리의 차이로 5 dB(A) 이상의 소음 감쇠 효과를 확인하였다. 이상의 결과를 종합하여 볼 때 치과 치료 시 진료실 소음은 치과 의료기관 종사자에게 정신적, 육체적 피해를 줄 수 있는 정도이며, 본 연구결과를 통하여 얻어진 자료들이 기초가 되어 더 많은 치과 진료 시의 소음에 대한 특성이 파악된다면 직장환경의 질을 높이기 위한 체계적인 소음 감소 대책 수립이 가능할 것으로 생각된다.

A Study on the Noise Characteristics of noise occurred when medical examination in dental clinic

  • Ji, Dong-Ha;Lee, Yong-Gyoo
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권12호
    • /
    • pp.163-170
    • /
    • 2018
  • This study was conducted to investigate the effects of noise from dental clinics on workers and to establish a reduction plan. The noise generated by the treatment instrument(Ultrasonic scaler, Hand piece, 3-way syringe, Suction, Compressor) was measured in order to determine the characteristics(level, frequency) of the noise during medical treatment(Oral prophylaxis, Conservation treatment, Prosthesis treatment, Implant Scaling, Tooth eliminating). We also assessed the noise levels in dental clinic using evaluation indicators such as NR-curves and NRN. The results of the analysis showed that the noise generated during the treatment was 85dB(A) ~ 70dB(A) and that the high frequency component was dominant, which would affect the workers working at the dental clinic. The NR-curve analysis showed NR-67 to NR-83 and the high frequency components of 4kHz to 8kHz were predominant and far exceeded noise levels in the workplace. To minimize the noise damage of workers and to provide high quality medical service, it is necessary to establish countermeasures such as wearing a soundproof and periodic hearing tests.

Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide

  • Matheus Barros-Costa;Julia Ramos Barros-Candido;Matheus Sampaio-Oliveira;Deborah Queiroz Freitas;Alexander Tadeu Sverzut;Matheus L Oliveira
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.191-199
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods: One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test(α=0.05). Results: Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion: Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

Efficacy of active noise-canceling headphones in patients undergoing ultrasonic scaling

  • Jeong-Woong Kim;Bo-Ah Lee;Yu-Seon Park;Jinho Chung;Seong-Ho Choi;Young-Taek Kim
    • Journal of Periodontal and Implant Science
    • /
    • 제53권4호
    • /
    • pp.269-282
    • /
    • 2023
  • Purpose: Dental fear hinders patients from receiving appropriate dental treatment. In particular, the noise generated by high-speed air turbines and ultrasonic scalers can adversely affect patients. Many efforts have been made to reduce the discomfort caused by noise, but no methods are definitively recommended. The purpose of this study was to determine the efficacy of active noise-canceling (ANC) headphones in reducing the pain and discomfort associated with dental scaling. Methods: Fifty-five patients requiring scaling and root planing, aged ≥19 years and showing no auditory problems, were included. Scaling was performed for the bilateral maxillary molars and premolars while patients wore headphones, with ANC turned either on or off. The degree of noise and pain reduction in the on and off conditions were surveyed using a visual analog scale (VAS). The Wilcoxon signed-rank test was performed to compare noise-and pain-related discomfort with ANC turned on and off. Results: The sample included 28 men and 27 women with a mean age of 45.45±13.12 years. The average noise-related discomfort score was 3.84±2.12 and 2.95±1.99 when noise-canceling was turned off and on, respectively, with a statistically significant difference (P<0.05). Similarly, the average pain-related discomfort score was 3.78h±2.00 and 3.09±1.96 when noise-canceling was turned off and on, respectively, which was a statistically significant difference (P<0.05). Conclusions: The use of ANC headphones seems to reduce the discomfort caused by noise and pain in patients undergoing scaling.

안전하고 효과적인 광대축소술 (Safe and Effective Reduction Malarplasty)

  • 강영호
    • 대한치과의사협회지
    • /
    • 제58권2호
    • /
    • pp.103-113
    • /
    • 2020
  • Background: Reduction malarplasty is one of the most popular facial contouring surgeries in east Asia for making patients' faces smaller. Currently in Korea, reduction malarplasty surgeries are performed mostly at plastic surgery clinics, but few cases are done at oral and maxillofacial surgery clinics. The reason might be because of post-operative complications after reduction malarplasty, such as undercorrection, overcorrection, asymmetry, cheek drooping, malunion, pain and noise. Those complications should be uneasy to be handled by oral and maxillofacial surgeons, however, they can be prevented by knowing the effective and safe reduction malarplasty techniques. Therefore, in this article the author as an oral and maxillofacial surgeon, would like to suggest safe and effective surgical methods for reduction malarplasty customized for Korean patients. Method: L- shape osteotomy of zygomatic body was performed with intraoral approach via vestibular incision, and the zygomatic arch was osteotomized with extraoral approach via sideburn incision. Then zygomatic complex was separated and rotated mesio-superiorly without removal of a bony strip and fixed with miniplates and microplates without making a bony gap. Conclusion: Surgical results were favorable and satisfied by the patients without cheek drooping, malunion, undercorrection and asymmetry.

  • PDF

광학 현미경 영상 기반 시간 분해능이 향상된 비지역적 평균 노이즈 제거 알고리즘 가능성 연구 (Feasibility Study of Non Local Means Noise Reduction Algorithm with Improved Time Resolution in Light Microscopic Image)

  • 이영진;김지연
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.623-628
    • /
    • 2019
  • 본 연구의 목적은 시간 분해능이 향상된 비지역적 평균 (fast non local means, FNLM) 노이즈 제거 알고리즘을 모델링하여 광학 현미경 영상에서의 적용 가능성을 확인하는 것이다. 이를 위해 실제 흰쥐 (mouse)의 첫째어금니 치아를 사용하여 영상을 획득한 후 기존에 널리 사용되고 있는 노이즈 제거 알고리즘과 제안하는 FNLM 알고리즘을 각각 적용하여 비교하였다. 정량적 평가는 대조도 대 잡음비 (contrast to noise ratio, CNR), 변동계수 (coefficient of variation, COV), 그리고 최근에 개발된 no reference 기반의 방법인 natural image quality evaluator (NIQE)와 Blind/referenceless image spatial quality evaluator (BRISQUE)를 사용하였다. 결과적으로 모든 정량적 평가 인자에서 제안하는 FNLM 노이즈 제거 알고리즘이 가장 우수한 값을 나타내었다. 특히나 치아의 전체적인 형태학적 영상을 분석할 수 있는 NIQE와 BRISQUE 인자는 원본영상에 비하여 각각 1.14와 1.12배 향상됨을 확인할 수 있었다. 결론적으로 소동물 치아 광학 현미경 영상에서의 FNLM 노이즈 제거 알고리즘의 유용성 및 가능성을 증명하였다.

치과기공사의 근무 환경 및 업무특성 평가에 관한 연구 (A Study on Working conditions and Characteristics of Dental Technicians)

  • 송재상;홍영호;최상준
    • 대한치과기공학회지
    • /
    • 제33권4호
    • /
    • pp.379-390
    • /
    • 2011
  • Purpose: This study was conducted to improve the working conditions of dental technicians, through survey for working conditions related to perform one's duty, the extent of personal exposure to substances hazardous and complaint rate and factor of job stress and subjective symptom on musculoskeletal disorders. Methods: Using four types of structured questionnaires: social and demographic factor; the actual conditions of working space; working conditions; and characteristics of dental technicians, respondents filled in the questionnaires and the results were analyzed statistically. Results: The evaluation of comfort in working place found that satisfaction level on indoor noise was the lowest with 2.6 on a five-point scale and privacy space followed 2.8 point. In reasons for dissatisfaction with job, over workload ranked the highest by 25.4% and role overload had the highest by 39.5% in job stress factors. Based on the results, we could draw conclusion that dental technicians were unsatisfied with role overload and heavy workload a day. In reasons for musculoskeletal symptom prevalence, long-patient work was the highest by 24.1%. It was thought to cause dental technicians need deep procession and long-patient work due to the nature of their job. Conclusion: In conclusion, noise reduction and privacy space are required to improve job efficiency of dental technicians. In addition; we need to think of ways to increase the job satisfaction with adequate rest while deep procession and long-patient working.

The effects of noise reduction, sharpening, enhancement, and image magnification on diagnostic accuracy of a photostimulable phosphor system in the detection of non-cavitated approximal dental caries

  • Kajan, Zahra Dalili;Davalloo, Reza Tayefeh;Tavangar, Mayam;Valizade, Fatemeh
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.81-87
    • /
    • 2015
  • Purpose: Contrast, sharpness, enhancement, and density can be changed in digital systems. The important question is to what extent the changes in these variables affect the accuracy of caries detection. Materials and Methods: Forty eight extracted human posterior teeth with healthy or proximal caries surfaces were imaged using a photostimulable phosphor (PSP) sensor. All original images were processed using a six-step method: (1) applying "Sharpening 2" and "Noise Reduction" processing options to the original images; (2) applying the "Magnification 1:3" option to the image obtained in the first step; (3) enhancing the original images by using the "Diagonal/"option; (4) reviewing the changes brought about by the third step of image processing and then, applying "Magnification 1:3"; (5) applying "Sharpening UM" to the original images; and (6) analyzing the changes brought about by the fifth step of image processing, and finally, applying "Magnification 1:3." Three observers evaluated the images. The tooth sections were evaluated histologically as the gold standard. The diagnostic accuracy of the observers was compared using a chi-squared test. Results: The accuracy levels irrespective of the image processing method ranged from weak (18.8%) to intermediate (54.2%), but the highest accuracy was achieved at the sixth image processing step. The overall diagnostic accuracy level showed a statistically significant difference (p=0.0001). Conclusion: This study shows that the application of "Sharpening UM" along with the "Magnification 1:3" processing option improved the diagnostic accuracy and the observer agreement more effectively than the other processing procedures.