• Title/Summary/Keyword: Dental models

Search Result 595, Processing Time 0.03 seconds

Accuracy of dental model based on the state-of-the-art manufacturing technique (첨단 제조기술 기반으로 제작된 치과용 모형의 정확도에 관한 연구)

  • Kim, Jae-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.693-700
    • /
    • 2020
  • This study compared the accuracy and reliability of definitive casts fabricated from a digital impression and conventional impression technique. A master model with the prepared upper full-arch tooth was used. Samples of ten plaster models and ten polyurethane models were duplicated using a selected standard master model. Six linear measurements were recorded between the landmarks, directly on each of the stone models and the polyurethane models on two occasions by a double examiner. The Wilcoxon signed-rank test, interclass correlation coefficient (ICC), measurement error (MSE), and limit of agreement (LoA) were used for statistical analysis. The ICC ranged from 0.76 to 0.99 when comparing the stone models and polyurethane models. The mean difference between the stone models and polyurethane models ranged from 0.09mm to 0.20mm, suggesting that stone models might be slightly larger than polyurethane models. Based on this study, the accuracy of the polyurethane models in evaluating the performance of an oral scanner and subtractive technology was acceptable. Further studies will be needed on patient subjects under clinical conditions that may involve missing or malpositioned teeth and fixed dental prostheses because this study was limited to use a standard master model and duplicated sample models in a laboratory setting.

Influence of threshold value of computed tomography on the accuracy of 3-dimensional medical model (전산화단층 촬영상의 임계치가 3차원 의학모델 정확도에 미치는 영향에 대한 연구)

  • Lee Byeong-Do;Lee Wan
    • Imaging Science in Dentistry
    • /
    • v.32 no.1
    • /
    • pp.27-33
    • /
    • 2002
  • Purpose: To evaluate the influence of threshold value of computed tomography on the accuracy of rapid prototyping (RP) medical model Material and Methods : CT datas of a human dry skull were transferred from CT scanner via compact disk to a personal computer (PC). 3-dimensional image reconstruction on PC by V-works/sup TM/ 3.0 (CyberMed. Inc.) software and RP models fabrication were followed. 2-RP models were produced by threshold value of 500 and 800 selected in surface rendering process. Linear measurements between arbitrary 12 anatomical landmarks on dry skull, 3-D image model, and 2-RP models were done and compared. Thus, the accuracy of 500 RP and 800RP models was respectively evaluated. Results: There was mean difference (% difference) in absolute value of 2.27 mm (2.73%) between linear measurements of dry skull and 500 RP model. There was mean difference (% difference) in absolute value of 1.94 mm (2.52%) between linear measurements of dry skull and 800 RP model. Conclusion: Slight difference of threshold value in rendering process of 3-D modelling made a influence on the accuracy of RP medical model.

  • PDF

A ROENTGENOCEPHALOMETRIC STUDY FOR THE EVALUATION OF THE FACIAL ESTHETICS IN THE KOREAN ADULT FEMALES (성인 여자에 있어서의 안모심미성에 관한 방사선학적 연구)

  • Park Mi Yea;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.14 no.1
    • /
    • pp.39-50
    • /
    • 1984
  • The aim of this study was to evaluate the dentofacial relationship of the Korean adult females who had excellent profile using roentgenocephalometry. The subjects were 35 females from 19 to 24 years of age selected among the professional models, beauty contest winners and performing stars. And, as the control group, 37 females from 18 to 23 years of age with normal occlusion and acceptable profile were selected. In both groups, each variable was measured and evaluated statistically introducing 24 reference points, 22 reference lines and 17 reference angles respectively. Conclusions from this study were as follows; 1. There was no significant difference between the two groups. But SNA and convexity angle which had indicated the maxillary protrusion were lesser in the professional models, beauty contest winners and performing stars than in ~he control group. 2. In the professional models, beauty contest winners and performing stars, the maxillary and mandibular incisors were more upright than in the control group. 3. The protrusion of the upper and lower lip was lesser in the professional models, beauty contest winners and performing stars than in the control group. 4. Professional models, beauty contest winners and performing stars revealed more straight profile than the control group and were similar to that of the Caucasian. 5. Generally, it was the tendency that the straight profile was accepted as esthetics.

  • PDF

Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts

  • Yousefi, Faezeh;Shokri, Abbas;Zahedi, Foozie;Farhadian, Maryam
    • Imaging Science in Dentistry
    • /
    • v.51 no.4
    • /
    • pp.429-438
    • /
    • 2021
  • Purpose: This study investigated the accuracy of laser-scanned models and 3-dimensional(3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. Materials and Methods: CBCT scans and plaster models from 30 patients were retrieved. Plaster models were scanned by an Emerald laser scanner (Planmeca, Helsinki, Finland). Sixteen different measurements, encompassing the mesiodistal width of teeth and both arches' length and width, were calculated using various landmarks. Linear measurements were made on laser-scanned models using Autodesk Meshmixer software v. 3.0 (Autodesk, Mill Valley, CA, USA), on 3D-rendered CBCT models using OnDemand 3D v. 1.0 (Cybermed, Seoul, Korea) and on plaster casts by a digital caliper. Descriptive statistics, the paired t-test, and intra- and inter-class correlation coefficients were used to analyze the data. Results: There were statistically significant differences between some measurements on plaster casts and laser-scanned or 3D-rendered CBCT models (P<0.05). Molar mesiodistal width and mandibular anterior arch width deviated significantly different from the gold standard in both methods. The largest mean differences of laser-scanned and 3D-rendered CBCT models compared to the gold standard were 0.12±0.23 mm and 0.42±0.53 mm, respectively. Most of the mean differences were not clinically significant. The intra- and inter-class correlation results were acceptable for all measurements(>0.830) and between observers(>0.801). Conclusion: The 3D-rendered CBCT images and laser-scanned models were useful and accurate alternatives to conventional plaster models. They could be used for clinical purposes in orthodontics and prostheses.

Evaluation of different approaches for using a laser scanner in digitization of dental impressions

  • Lee, Wan-Sun;Kim, Woong-Chul;Kim, Hae-Young;Kim, Wook-Tae;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2014
  • PURPOSE. This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS. Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test ($\alpha$=0.05), repeated measures ANOVA and two-way ANOVA (${\alpha}=0.05$). RESULTS. The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION. The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit ($120{\mu}m$).

교합형의 출현빈도에 대한 고찰

  • Chin, Yong-Whan
    • The Journal of the Korean dental association
    • /
    • v.12 no.6
    • /
    • pp.369-371
    • /
    • 1974
  • Using 316 plaster models of dental arches of Korean, (ages from 16 to 53) the auther observed the occlusion forms by the Welcker's classifying method. The results were as follows: Psalidontie type is most frequency seen, and its frequency is about 87% in male and about 91% in female. The frequency of occlusal form was decreased in the order of Stegodontie, Lalidodontie and Opisthodontie. Type. There were seldom appeared Progenie and Hiatodontie type.

  • PDF

The new approach to maxillary and mandibular anterior dental arch forms - In Korean normal occlusion models (상하악 전치부 치열궁 형태에 대한 새로운 접근 - 한국성인 정상교합자 모델에서)

  • Ha, Man-Hee;Son, Woo-Sung;Yang, Hoon-Chul
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.347-355
    • /
    • 2001
  • Maxillary and mandibular anterior dental arches often have the problems of occlusal relation and esthetics by malformations of teeth, congenital missing, et at. Though the clinician usually use the anterior ratio to overcome this problems, he has the limitation of a direct application this ratio to the prediction of anterior occlusal relationship by the change of anterior ratio as dental arch form, intercanine width, segment depth and arch perimeter. So this study examine maxillary and mandibular anterior dental arch forms by least square method using Korean normal occlusion models(man : 20 casts, woman : 20 casts). Maxillary and mandibular anterior dental arches of Korean normal occlusion models are curve fitted to polynomial function, beta function, hyperbolic cosine function in order. And this accuracy of curve fitting is constant regardless of man/woman and maxilla/mandible. The relationships between intercanine width, segment depth, and arch perimeter based on this owe fitted dental arch form are acquired. This relationships will give the prediction of anterior dental arch form and the information of more accurate anterior ratio according to intercanine width.

  • PDF

GROWTH CHANGES OF DENTAL ARCHES DURING THE DECIDUOUS DENTITION PERIOD (유치열기(乳齒列期) 아동(兒童)의 치궁발육(齒穹發育)에 관(關)한 연구(硏究))

  • Byun, In-Sook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.7 no.1
    • /
    • pp.63-74
    • /
    • 1980
  • The purpose of this study is to analyze the width and length changes of the dental arches during the deciduous dentition period. 600 stone models of maxillary and mandibular arches obtained from the children aged 3, 4, or 5 years were under measurement. The results were as follows ; Arch widths and lengths differed with age, sex and arch. 1. * Widths of dental archs increase with age both in males and in females. * Lengths of dental arches decrease with age in females, but remain somewhat stable in males. 2. * The dental arches of males were wider than those of females in both the ant. and the post. section. * The dental arches of males were longer than those of females: ant.arch lengths were almost same, but post. arch lengths were longer in males. 3. * Upper arches were definitely wider and longer than lower arches.

  • PDF

Evaluation of Appointment Policy and Scheduling Rule for a Dental Clinic Based on Computer Simulation (시뮬레이션을 이용한 치과의원의 예약정책과 스케줄링 규칙 평가)

  • Lee, Jong-Ki;Kim, Myeng-Ki;Ha, Byung-Hyun
    • Korea Journal of Hospital Management
    • /
    • v.16 no.4
    • /
    • pp.161-182
    • /
    • 2011
  • In today's competitive dental markets, it is of paramount importance to improve service quality and at the same time to use scarce resource efficiently. In this study, we present appointment policies and scheduling rules for private dental clinics to reduce the waiting time of patients and to increase the revenue by utilizing resource more effectively. This study validates the proposed appointment policies and scheduling rules based on simulation models. We show that the bottleneck-based appointment policy is the most effective among appointment policies, followed by the multiple-block appointment one. The shortest processing time among scheduling rules contributes most to the performance of the appointment system.

  • PDF

Deep Learning in Dental Radiographic Imaging

  • Hyuntae Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • Deep learning algorithms are becoming more prevalent in dental research because they are utilized in everyday activities. However, dental researchers and clinicians find it challenging to interpret deep learning studies. This review aimed to provide an overview of the general concept of deep learning and current deep learning research in dental radiographic image analysis. In addition, the process of implementing deep learning research is described. Deep-learning-based algorithmic models perform well in classification, object detection, and segmentation tasks, making it possible to automatically diagnose oral lesions and anatomical structures. The deep learning model can enhance the decision-making process for researchers and clinicians. This review may be useful to dental researchers who are currently evaluating and assessing deep learning studies in the field of dentistry.