• 제목/요약/키워드: Dental inlay

검색결과 63건 처리시간 0.029초

성별과 연령에 따른 치과보철물 양상에 대한 조사연구 - 전자북도의 중소도시를 중심으로- (The Study on Patterns of Prosthetic Restoration, by Age and Sex - Centering the medium and small city around Chollabuk-do -)

  • 김연수;전주연
    • 대한치과기공학회지
    • /
    • 제12권1호
    • /
    • pp.5-14
    • /
    • 1990
  • The purpose of this study were to investigate the patterns of prosthetic restorations according to sex and age. We had surveyed the out-patents of dental clinics it Jeon-Ju, Iri and Gun roan area. The abtained result were as follow ; 1. The patterns of prosthetic restoration in female was higher than male and 20$\sim$30 age groups was higher than others. 2. The crown was higher in prosthetic restoration. 3. The procelain appliance area was high in male and female on 20$\sim$29 age. 4. The partial denture was higher than full denture in both sex. 5. The crown appliance area was not different in both sex. 6. The 3 unit bridge was higher than other bridge in both sex. 7. The porcelain appliance area was high in male and female on upper anterior. 8. The inlay appliance area of lower posterior was higher than upper posterior. 9. The upper posterior was high in male, and the lower posterior was high in female in partial denture. 10. The full dentur was high in old age group.

  • PDF

10년 간격으로 관찰한 여대생의 구강보건 상태 변화에 대한 연구 (A STUDY ON DENTAL HEALTH STATUS AND THEIR DECENNIAL COMPARISONS OF KOREAN COLLEGE GIRL STUDENTS)

  • 강충규;이정석;이찬영;이승종;박동수
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.57-66
    • /
    • 1990
  • The author conducted a dental survey of college girl students and compared with that of college students 20 years and 10 years ago which based on the same criteria. The items of this survey included the prevalence of dental caries, DMFT and the kinds of restored materials. College girl students 2,294 were examined in May 1988, with the recommended criteria and method of W.H.O.. Among them, the data of 2,243 were analyzed and compared with the data of 1968 and 1978. The following results were obtained : 1. The average number of present teeth was $28.86{\pm}1.65$, which does not show much difference when compared to $29.00{\pm}1.94$ of 1968 and $28.97{\pm}1.64$ of 1978. 2. The prevalence of dental caries was 86.22%, which increased in comparison to 83.25% of 1968 and 84.92% of 1978. 3. DMF index was 19.98, which considerably increased in comparison to 14.56 of 1968 and 15.51 of 1978. 4. The number of DMFT was $5.75{\pm}5.04$ per student. Compared to $4.23{\pm}3.88$ of 1968 and $4.49{\pm}3.69$ of 1978, there is a considerable increase. I) The average number of decayed(D) teeth was $1.14{\pm}1.63$, which decreased from $1.16{\pm}1.57$ of 1968 and $2.09{\pm}2.16$ of 1978. II) The average number of missing(M) teeth was $0.23{\pm}0.73$, which also decreased from $0.69{\pm}1.11$ of 1968 and $0.32{\pm}0.79$ of 1978. III) The average number of filled(F) teeth was $4.39{\pm}4.91$, which increased from $2.38{\pm}3.33$ of 1968 and $2.09{\pm}3.17$ of 1978. 5. According to the analysis of filling material, filling baby including amalgam, gold inlay, resin, silicate cement and paladium inlay was 90.5%, which increased in comparison to 72.8% of 1968 and 83.6% of 1978. Among them, amalgam occupied 62.93%, which showed the most increase. On the other hand, crown and bridge was 6.5%, 3.0%, respectively, which showed continuous decrease from 12.1%, 15.1% of 1968 and 8.7%, 7.7% of 1978. Therefore, the prosthodontic treatment reduced due to the decrease of tooth extraction. In contrast, there is continuous increase of conservative treatment which maintaining natural tooth.

  • PDF

치과용 왁스의 변형측정에 관한 연구 (STUDIES ON THE DISTORTION OF SOME DENTAL WAXES)

  • 김철위
    • 대한치과보철학회지
    • /
    • 제16권1호
    • /
    • pp.17-21
    • /
    • 1978
  • The object of this study was to measure of the distortion of various dental waxes under condition simulating clinical usage. Eleven commercial product (table) including the inlay and baseplate waxes were tested, and compared in the study. Test specimens were prepared $5{\times}5{\times}65mm$. split brass mold. Placed this rod wax specimens and the brass wax distortion test mold into the water bath and tested the distortion values for waxes at $35^{\circ}C,\;40^{\cric}C,\;45^{\circ}C\;and\;50^{\circ}C$. Measured the distortion as the difference between the final (Df) and original (Do) distance between the ends of the specimen. Recorded Df, Do and Df-Do (Distortion) to the nearest 0.5mm. A minimum of five specimens were tested for each material. The following conclusions may be drawn from this study. 1) It can be seen that, a significant wax distortion was obtained with the temperature of forming the pattern, and the length of time and the temperature at which it was stored. 2) It was found that, when the storage time was increased, the wax distortion was correspondingly increased. At the sametime, the higher the storage time was employed, the distortion was obviously much greater. 3) It can be observed that the higher the temperature at which the wax was manipulated, the less was the resulting distortion upon storage.

  • PDF

Mechanical Properties and Microstructure of the Leucite-Reinforced Glass-Ceramics for Dental CAD/CAM

  • Byeon, Seon-Mi;Song, Jae-Joo
    • 치위생과학회지
    • /
    • 제18권1호
    • /
    • pp.42-49
    • /
    • 2018
  • The computer-aided design/computer-aided manufacturing (CAD/CAM) system was introduced to shorten the production time of all-ceramic restorations and the number of patient visits. Among these types of ceramic for dental CAD/CAM, they have been processed into inlay, onlay, and crown shapes using leucite-reinforced glass-ceramics to improve strength. The purpose of this study was to observe the mechanical properties and microstructure of leucite-reinforced glass-ceramics for dental CAD/CAM. Two types of leucite-reinforced glass-ceramic blocks (IPS Empress CAD, Rosetta BM) were prepared with diameter of 13 mm and thickness of 1 mm. Biaxial flexural testing was conducted using a piston-on-three-ball method at a crosshead speed of 0.5 mm/min. Weibull statistics were used for the analysis of biaxial flexural strength. Fracture toughness was obtained using an indentation fracture method. Specimens were observed by field emission scanning electron microscopy to examine the microstructure of the leucite crystalline phase after acid etching with 0.5% hydrofluoric acid aqueous solution for 1 minute. The results of strength testing showed that IPS Empress CAD had a mean value of $158.1{\pm}8.6MPa$ and Rosetta BM of $172.3{\pm}8.3MPa$. The fracture toughness results showed that IPS Empress CAD had a mean value of $1.28{\pm}0.19MPa{\cdot}m^{1/2}$ and Rosetta BM of $1.38{\pm}0.12MPa{\cdot}m^{1/2}$. The Rosetta BM sample exhibited higher strength and fracture toughness. Moreover, the crystalline phase size and ratio were increased in the Rosetta BM sample. The above results are expected to elucidate the basic mechanical properties and crystal structure characteristics of IPS Empress CAD and Rosetta BM. Additionally, they will help develop leucite-reinforced glass-ceramic materials for CAD/CAM.

The effect of hard-type crosslinked hyaluronic acid with particulate bone substitute on bone regeneration: positive or negative?

  • Yun, Junseob;Lee, Jungwon;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Lee, Yong-Moo
    • Journal of Periodontal and Implant Science
    • /
    • 제52권4호
    • /
    • pp.312-324
    • /
    • 2022
  • Purpose: The role of hard-type crosslinked hyaluronic acid (HA) with particulate bone substitutes in bone regeneration for combined inlay-onlay grafts has not been fully investigated. We aimed to evaluate the effect of hard-type crosslinked HA used with bone substitute in terms of new bone formation and space maintenance. Methods: A 15-mm-diameter round defect was formed in the calvaria of 30 New Zealand White rabbits. All animals were randomly assigned to 1 of 3 groups: the control group (spontaneous healing without material, n=10), the biphasic calcium phosphate (BCP) graft group (BCP, n=10), and the BCP graft with HA group (BCP/HA, n=10). The animals were evaluated 4 and 12 weeks after surgery. Half of the animals from each group were sacrificed at 4 and 12 weeks after surgery. Samples were evaluated using micro-computed tomography, histology, and histomorphometry. Results: The BCP group showed higher bone volume/tissue volume (BV/TV) values than the control and BCP/HA groups at both 4 and 12 weeks. The BCP and BCP/HA groups showed higher bone surface/tissue volume (BS/TV) values than the control group at both 4 and 12 weeks. The BCP group showed higher BS/TV values than the control and BCP/HA groups at both 4 and 12 weeks. No statistically significant difference in newly formed bone was found among the 3 groups at 4 weeks. The BCP group showed significantly higher new bone formation than the BCP/HA group at 12 weeks. Conclusions: Hard-type crosslinked HA did not show a positive effect on new bone formation and space maintenance. The negative effect of hard-type crosslinked HA may be due to the physical properties of HA that impede osteogenic potential.

Marginal and internal fit of nano-composite CAD/CAM restorations

  • Park, So-Hyun;Yoo, Yeon-Jee;Shin, Yoo-Jin;Cho, Byeong-Hoon;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.37-43
    • /
    • 2016
  • Objectives: The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods: A full veneer crown and an mesio-occluso-distal (MOD) inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU) and experimental nano-composite CAD/CAM blocks (EB) under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results: Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000). In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001). Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000). Conclusions: The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

치과용 접착제가 복합레진 인레이와 레진시멘트의 결합력에 미치는 영향 (INFLUENCE OF ADHESIVE APPLICATION ON SHEAR BOND STRENGTH OF THE RESIN CEMENT TO INDIRECT RESIN COMPOSITE)

  • 송미혜;박수정;조현구;황윤찬;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.419-427
    • /
    • 2008
  • 본 연구는 레진시멘트의 레진인레이에 대한 접착 시 접착제 혹은 primer의 사용이 결합력에 영향을 미치는지 평가하기 위해 시행하였다. 직경 5mm,높이 4.5mm의 원기둥 형태로 제작한 레진인레이 (Tescera, Bisco, USA)의 표면을 1000번, 1500번 그리고 2000번 사포로 주수 하에서 연마하여 평편한 면을 형성한 후 레진인레이의 표면에 sandblasting을 시행한 후 표면에 1분 동안 silane을 도포하였다. 2군으로 나누어 한 군은 대조군으로, 다른 한 군은 표면에 동일한 제조사의 접착제나 프라이머를 도포한 후 중합하였다. 레진인레이 상에 3mm 직경의 구멍이 형성된 아크릴판을 고정하고, 구멍에 레진 시멘트를 주입하여 경화시켰다. 레진 시멘트는 Panavia-F (Kurary), Varolink-II(Ivoclar-Vivadent), RelyX Unicem(3M ESPE), Duolink(Bisco)와 자가중합형인 Multilink (Ivoclar-Vivadent)를 사용하였다. 제작된 시편을 만능물성시험기에 위치시고 전단결합강도를 측정하였다. 측정 결과 접착제나 프라이머를 도포한 군은 대조군에 비해 전단결합강도가 증가하였다 (p<0.05). 하지만 Variolink-II와 Panavia-F는 전단결합강도의 차이를 보이지 않았다. 대조군에서는 각 레진 시멘트간에 전단결합강도의 유의한 차이를 보였으며 (p<0.01) Variolink-II가 가장 높은 결합강도를 보인 반면, 자가중합형인 Multilink가 가장 낮은 결합강도를 보였다. 하지만, 접착제나 프라이머를 도포한 군에서는 각 제품간에 전단결합강토의 차이를 보이지 않았다. 이상의 결과 이원중합형이나 자가중합형 레진시멘을 이용하여 레진인레이 부착 시 silane 처리 후 접착제나 프라이머의 도포가 결합 강도의 증가를 위해 필요하리라 사료된다.

CAD/CAM 세라믹 인레이에 대한 3종의 레진 시멘트의 전단결합강도에 관한 연구 (Shear bond strength of the three different kinds of resin cement on CAD/CAM ceramic inlay)

  • 백철우;박철우;박준섭;류재준
    • 대한치과보철학회지
    • /
    • 제51권1호
    • /
    • pp.20-26
    • /
    • 2013
  • 연구 목적: 본 연구는 최근 심미수복에 주로 사용되는 CAD/CAM 세라믹 인레이와 각종 레진 시멘트간의 결합강도를 알아보고자 하였다. 연구 재료 및 방법: 원기둥 모양의 세라믹 블록(높이: 5 mm, 직경: 3 mm)을 Cerec3로 제작하고, 총 90개의 우식이 없는 대구치의 상아질 표면에 세 종류의 레진 시멘트(Unicem$^{(R)}$, Biscem$^{(R)}$, Variolink II$^{(R)}$)를 사용하여 각각 제조업체의 지시에 따라 접착했다. 90개의 시편을 레진 시멘트의 종류에 따라 3개의 군으로 나누고, 각 군의 절반은 $5-55^{\circ}C$, 5,000 cycle 조건 하에서 thermocycling을 시행하였고, 다른 절반은 시행하지 않았다. 모든 시편은 결합강도를 측정하기 전에 $37^{\circ}C$ 생리 식염수에 24시간 동안 보관되었다. 전단결합강도는 만능시험기를 이용하여 0.5 mm/min의 cross head speed로 측정하였다. 결과 값은 t-test 및 one-way ANOVA를 사용하여 통계 분석하였다. 결과: Unicem$^{(R)}$ 군의 전단결합강도가 thermocycling 후에 약간 감소했으나 3 개의 군 중 가장 높은 결합 강도를 보였다. Unicem$^{(R)}$ 및 Valiolink II$^{(R)}$ 군의 전단결합강도가 thermocycling에 영향을 받았지만 Biscem$^{(R)}$은 영향을 받지 않았다(P<.05). Thermocyling 전에는 3개의 군 간의 결합강도에 유의한 차이가 없었지만, thermocyling 후에는 Unicem$^{(R)}$과 Valiolink II$^{(R)}$ 군 간에 유의한 차이가 있었다(P<.05). 결론:CAD/CAM 세라믹 인레이 수복물을 치아에 접착할 때, etch-and-rinse 레진 시멘트인 Valiolink II$^{(R)}$ 대신self-adhesive 레진 시멘트인 Unicem$^{(R)}$과 Biscem$^{(R)}$을 사용해도 임상적으로 유용하다.

구강 내 디지털 인상채득을 통한 맞춤형 지대주와 시멘트 합착 후 나사형 임플란트 보철 수복 증례 (Customized abutment and screw-type implant prostheses after cementation based on the digital intra-oral impression technique)

  • 홍용신;박은진;김선종;김명래;허성주;박지만
    • 대한치과보철학회지
    • /
    • 제50권1호
    • /
    • pp.67-73
    • /
    • 2012
  • 최근 디지털 인상채득 시스템이 개발되면서 이를 기존의 CAD/CAM 시스템과 접목한 인레이, 온레이, 크라운이나 간단한 계속가공의치 등의 고정성 보철물의 제작이 활발히 소개되고 있다. 그러나 임플란트 보철에서는 주로 기존의 아날로그식 인상채득 후 이를 스캔하여 제작하는 방법이 사용되어 왔으나, 구강 내 디지털 스캔한 데이터를 이용하여 나사형 보철물을 제작하는 술식은 아직 활발히 이루어지지 않았다. 이에 본 증례보고에서는 6명의 환자를 대상으로 구강 내 스캐너인 iTero를 사용하여 디지털 스캔을시행한후그중다섯명은맞춤형지대주와 시멘트 합착 후 나사형 임플란트 보철물(screw-retained implant prosthesis after cementation, or SCRP)을 제작하였고, 임상적으로 기능과 심미적인 측면으로 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

Comparative analysis on reproducibility among 5 intraoral scanners: sectional analysis according to restoration type and preparation outline form

  • Park, Ji-Man
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권5호
    • /
    • pp.354-362
    • /
    • 2016
  • PURPOSE. The trueness and precision of acquired images of intraoral digital scanners could be influenced by restoration type, preparation outline form, scanning technology and the application of power. The aim of this study is to perform the comparative evaluation of the 3-dimensional reproducibility of intraoral scanners (IOSs). MATERIALS AND METHODS. The phantom containing five prepared teeth was scanned by the reference scanner (Dental Wings) and 5 test IOSs (E4D dentist, Fastscan, iTero, Trios and Zfx Intrascan). The acquired images of the scanner groups were compared with the image from the reference scanner (trueness) and within each scanner groups (precision). Statistical analysis was performed using independent two-samples t-test and analysis of variance (${\alpha}=.05$). RESULTS. The average deviations of trueness and precision of Fastscan, iTero and Trios were significantly lower than the other scanners. According to the restoration type, significantly higher trueness was observed in crown and inlay than in bridge. However, no significant difference was observed among four sites of preparation outline form. If compared by the characteristics of IOS, high trueness was observed in the group adopting the active triangulation and using powder. However, there was no significant difference between the still image acquisition and video acquisition groups. CONCLUSION. Except for two intraoral scanners, Fastscan, iTero and Trios displayed comparable levels of trueness and precision values in tested phantom model. Difference in trueness was observed depending on the restoration type, the preparation outline form and characteristics of IOS, which should be taken into consideration when the intraoral scanning data are utilized.