• 제목/요약/키워드: Dental implant system

검색결과 333건 처리시간 0.03초

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS: HISTOMORPHOMETRIC AND RESONANCE FREQUENCY ANALYSIS IN DOGS

  • Song Woo-Seok;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.671-678
    • /
    • 2004
  • Statement of problem. Reducing treatment time in implant dentistry is a matter of main concern. There are so many factors affecting the success rate of immediate or early loaded implant for the initial bone response. The especially microscopic properties of implant surfaces playa major role in the osseous healing of dental implant. Purpose. The aims of this study were to perform a histologic and histomorphometric comparison of the healing characteristics anodically roughened surface, HA coated surface and RBM surface implant, and to compare of ISQ values measured by $Osstell^{TM}$ for resonance frequency analysis in dogs mandible during 2 weeks. Material and method. Bone blocks from 2 dogs were caught after covered healing for 0 day(2 h); Group I, 1 week; Group II and 2 weeks; Group III. One longitudinal section was obtained for each implant and stained with hematoxylin and eosin. Histomorphometric analysis was done with Kappa Imagebase system to calculate bone-to-implant contact and bone volumes inside the threads. ISQ values were measured in every time of surgery schedule. Conclusion. The experiment revealed that: 1. The percentages of bone-to-implant contact on the fixture in each group were not significantly different(P > 0.05). 2. The percentages of bone area inside the threads on the fixture in each group were not significantly different(P > 0.05). 3. The ISQ level showed clinical stability of each fixture during 2 weeks(all ISQ level ${\geq}71$ ).

골유도재생술과 동시에 식립한 임플란트의 변연골 흡수량에 대한 후향적 고찰 (Retrospective Clinical Study on Marginal Bone Loss of Implants with Guided Bone Regeneration)

  • 박슬지;선화경;고세욱;지영덕
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권6호
    • /
    • pp.440-448
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate marginal bone loss of the alveolar crest on implants with or without guided bone regeneration and variables that have influenced. Methods: The clinical evaluation were performed for survival rate and marginal bone loss of 161 endosseous implants installed with guided bone regeneration (GBR) in 83 patients from September 2009 to October 2010 in relation to sex and age of patients, position of implant, implant system, length and diameter of implant. Study group (n=42) implant with GBR procedure, control group (n=41) implant without GBR technique. Simultaneous GBR approach using resorbable membranes combined with autogenous bone graft or freeze-dried bone allograft or combination. Radiographic examinations were conducted at healing abutment connection and latest visit. Marginal bone level was measured. Results: Mean marginal bone loss was 0.73 mm in study group, 0.63 mm in control group. Implants in maxillary anterior area (1.21 mm) were statistically significant in study group (P<0.05), maxillary posterior area (0.81 mm) in control group (P<0.05). Mean marginal bone loss 1.47 mm for implants with diameter 3.4 mm, 0.83 mm for implants of control group with diameter 4.0 mm (P<0.05). Some graft materials showed an increased marginal bone loss but no statistically significant influence of sex, implant type or length. Conclusion: According to these findings, this study demonstrated the amount of marginal bone loss around implant has maintained a relative stable during follow-up periods. We conclude that implants with GBR had similar survival rate and crestal bone level compared with implants in native bone.

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF

성견에서 국산 임시 임플란트의 골 유착반응에 관한 연구 (Study on osseointegration of a Korean Transitional implant system in beagle dog)

  • 이욱재;정종원;김윤상;피성희;유형근;신형식
    • Journal of Periodontal and Implant Science
    • /
    • 제36권1호
    • /
    • pp.253-263
    • /
    • 2006
  • Purpose: Recently, dental implant systems have been widely used for the treatment of the extraction site, but we have been confronted with many limitations in esthetics, phonetics and function. Transitional implants(TI) were developed as a method of providing fixed provisional restorations during conventional implant healing. Until now, little data have been provided on korean transitional implants. The purpose of this study is to evaluate the implant placement site histologically after 4 weeks and 8 weeks. Materials and Methods : Test group( IntermetzzoTM MEGAGEN, KOREA) and control group(Mini Drive Lock, Intra Rock, U.S.A.) were immediately placed in interseptal or interproximal bone of beagle dog after mandibular premolars extraction, and had a healing period with non-submerged state but without loading, Both TI surfaces were composed of rough surfaces. Results: In the test group, the average percentage of BIC were respectively 39.40%(SD7.35) after 4 weeks and 44.05%(16.76) after 8 weeks, and In the control group were 50.75%(1.48) and 59.40%(0.00). Discussion: We evaluated the initial ability of the osseointegration of TI through this study. Because TI is placed with a conventional implant simultaneously and loaded immediately, the ability of osseointegration is a very important factor for the success of TI during the initial healing phase. Conclusion: The results of the histological evaluation of these two groups were similar to those mentioned in other studies for osseointegration of implant.

A short-term clinical study of marginal bone level change around microthreaded and platform-switched implants

  • Yun, Hee-Jung;Park, Jung-Chul;Yun, Jeong-Ho;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • 제41권5호
    • /
    • pp.211-217
    • /
    • 2011
  • Purpose: The marginal bone levels around implants following restoration are used as a reference for evaluating implant success and survival. Two design concepts that can reduce crestal bone resorption are the microthread and platform-switching concepts. The aims of this study were to analyze the placement of microthreaded and platform-switched implants and their short-term survival rate, as well as the level of bone around the implants. Methods: The subjects of this study were 27 patients (79 implants) undergoing treatment with microthreaded and platform-switched implants between October 2008 and July 2009 in the Dental Hospital of Yonsei University Department of Periodon-tology. The patients received follow-up care more than 6 months after the final setting of the prosthesis, at which time periapical radiographs were taken. The marginal bone level was measured from the reference point to the lowest observed point of contact between the marginal bone and the fixture. Comparisons were made between radiographs taken at the time of fixture installation and those taken at the follow-up visit. Results: During the study period (average of 11.8 months after fixture installation and 7.4 months after the prosthesis delivery), the short-term survival rate of microthreaded and platform-switched implants was 100% and the marginal bone loss around implants was $0.16{\pm}0.08$ mm, the latter of which is lower than the previously reported values. Conclusions: This short-term clinical study has demonstrated the successful survival rates of a microthread and platform-switched implant system, and that this system is associated with reduced marginal bone loss.

Implants and all-ceramic restorations in a patient treated for aggressive periodontitis: a case report

  • Hong, Jin-Sun;Yeo, In-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권3호
    • /
    • pp.97-101
    • /
    • 2010
  • A 23-year-old female with aggressive periodontitis was treated using dental implants and LAVA system. The severely compromised teeth were extracted irrespective of initial conservative periodontal treatment. An implant-supported overdenture with 4 implants was fabricated for the maxilla and all-ceramic restorations for the mandible. Esthetic and functional goals were achieved with team approach involving periodontists and prosthodontists. This case report describes a treatment procedure for a generalized aggressive periodontitis patient with severe bone resorption.

CAD/CAM으로 제작한 점막하 지르코니아 임플란트 보철 수복 증례 (Submucosal zirconia implant prosthesis fabricated with CAD/CAM)

  • 장재승;김선재
    • 대한치과보철학회지
    • /
    • 제52권4호
    • /
    • pp.352-358
    • /
    • 2014
  • 최근 지르코니아와 CAD/CAM을 이용하는 심미적인 임플란트 보철치료 방법들이 많이 소개되고 있다. 그러나 이러한 방법들은 치은부위와 교합면부위에서 한계점들을 가지고 있다. 이에 본 증례에서는 지르코니아와 CAD/CAM 시스템을 이용하여 고정체 1 mm 상부에서부터 형성되는 점막하지르코니아 임플란트 보철물을 제작하고 이를 타이타늄 지대주와 접착하여 시멘트 나사 유지형 보철물을 제작하였다. 임상적으로 심미적이고 기능적면에서 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

Evaluation of dental panoramic radiographic findings in edentulous jaws: A retrospective study of 743 patients "Radiographic features in edentulous jaws"

  • Kose, Taha Emre;Demirtas, Nihat;Karabas, Hulya Cakir;Ozcan, Ilknur
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권5호
    • /
    • pp.380-385
    • /
    • 2015
  • PURPOSE. The aim of this study was to determine the frequency of significant panoramic radiographic findings and eventual treatment requirements before conventional or implant supported prosthetic treatment in asymptomatic edentulous patients. MATERIALS AND METHODS. A total of 743 asymptomatic edentulous patients were retrospectively evaluated using a digital panoramic system. We analyzed the radiographic findings, including impacted teeth, retained root fragments, foreign bodies, severe atrophy of the posterior maxillary alveolar bone, mucous retention cysts, soft tissue calcifications and radiopaque-radiolucent conditions. RESULTS. Four-hundred-eighty-seven (65.6%) patients had no radiographic finding. A total of 331 radiographic findings were detected in 256 (34%) patients. In 52.9% (n=175) of these conditions, surgical treatment was required before application of implant-supported fixed prosthesis. However, before application of conventional removable prosthesis surgical treatment was required for 6% (n=20) of these conditions. CONCLUSION. The edentulous patients who will have implant placement for implant-supported fixed prosthesis can frequently require additional surgical procedures to eliminate pathological conditions.

Abrasion of abutment screw coated with TiN

  • Jung, Seok-Won;Son, Mee-Kyoung;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권2호
    • /
    • pp.102-106
    • /
    • 2009
  • STATEMENT OF PROBLEM. Screw loosening has been a common complication and still reported frequently. PURPOSE. The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS. Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated poly-esther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS. TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION. Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.

하악 무치악 환자에서 Locator$^{(R)}$를 이용한 임플란트 피개의치 수복 증례 (Implant Supported Overdenture using Locator$^{(R)}$ System on Mandibular Edentulous Patient)

  • 유정현;신수연
    • 구강회복응용과학지
    • /
    • 제28권4호
    • /
    • pp.397-406
    • /
    • 2012
  • 치아가 상실되면 주위 치조골의 개조와 흡수가 일어나면서 위축성 무치악을 초래하게 되고, 치은부착은 점차적으로 감소된다. 이에 따라 총의치의 지지력 감소, 저작 효율의 저하와 통증으로 인해 무치악 환자들은 의치 사용의 어려움을 경험한다. 이를 개선하기 위해 하악에 2개의 임플란트를 식립하고 어태치먼트를 장착하는 피개의치의 형태가 유지력 측면에서 바람직한 치료 방법으로 우선적으로 고려되고 있다. 본 증례는 오래된 상, 하악 무치악을 가진 환자로 하악에 2개의 임플란트를 식립하고, 상악은 총의치, 하악은 Locator$^{(R)}$ attachment를 이용한 임플란트 피개의치로 제작하였다. 본 증례에서 기능적, 심미적으로 만족스러운 결과를 얻었기에 수복 과정과 결과에 대하여 보고하고자 한다.