• Title/Summary/Keyword: Dental imaging

Search Result 939, Processing Time 0.028 seconds

Prediction of osteoporosis using fractal analysis on periapical radiographs (구내방사선사진의 프랙탈 분석을 이용한 골다공증 예측)

  • Park Gum-Mi;Jung Yun-Hoa;Nah Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.35 no.1
    • /
    • pp.41-46
    • /
    • 2005
  • Purpose : The purpose of this study was to investigate whether the fractal dimension and radiographic image brightness of periapical radiograph were useful in predicting osteoporosis. Materials and Methods : Ninety-two postmenopausal women were classified as normal, osteopenia and osteoporosis group according to the bone mineral density of lumbar vertebrae and periapical radiographs of both mandibular molar areas were taken. The ROIs of 358 areas were selected at periapical and interdental areas and fractal dimension and radiographic image brightness were measured. Results : The fractal dimension in normal group was significantly higher than that in osteoporosis group at periapical ROI (P < 0.05). The radiographic image brightness in normal group was higher than that in osteopenia and osteoporosis group. There was significant difference not only between normal and osteopenia group (P < 0.05) but also within osteopenia and osteoporosis group (P< 0.01) at periapical ROI. Significant difference was observed not only between normal and osteopenia group but also between normal and osteoporosis group at interdental ROI (P< 0.01). Positive linear relationship was weakly shown at Pearson correlation analysis between fractal dimension and radiographic image brightness. BMD significantly correlated with fractal dimension at periapical ROI (P< 0.01), and BMD and radiographic image brightness significantly correlated at both periapical and interdental ROIs (P< 0.01). Conclusion : This study suggests that the fractal dimension and radiographic image brightness of periapical ROI may predict BMD. (Korean J Oral Maxillofac Radiol 2005: 35 : 41-6)

  • PDF

Assessment of bifid and trifid mandibular canals using cone-beam computed tomography

  • Rashsuren, Oyuntugs;Choi, Jin-Woo;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.229-236
    • /
    • 2014
  • Purpose: To investigate the prevalence of bifid and trifid mandibular canals using cone-beam computed tomography (CBCT) images, and to measure their length, diameter, and angle. Materials and Methods: CBCT images of 500 patients, involving 755 hemi-mandibles, were used for this study. The presence and type of bifid mandibular canal was evaluated according to a modified classification of Naitoh et al. Prevalence rates were determined according to age group, gender, and type. Further, their diameter, length, and angles were measured using PACSPLUS Viewer and ImageJ 1.46r. Statistical analysis with chi-squared and analysis of variance (ANOVA) tests was performed. Results: Bifid and trifid mandibular canals were found in 22.6% of the 500 patients and 16.2% of the 755 sides. There was no significant difference between genders and among age groups. The retromolar canal type accounted for 71.3% of the identified canals; the dental canal type, 18.8%; the forward canal type, 4.1%; and the trifid canal type, 5.8%. Interestingly, seven cases of the trifid canal type, which has been rarely reported, were observed. The mean diameter of the bifid and trifid mandibular canals was 2.2 mm and that of the main mandibular canal was 4.3 mm. Their mean length was 16.9 mm; the mean superior angle was $149.2^{\circ}$, and the mean inferior angle was $37.7^{\circ}$. Conclusion: Bifid and trifid mandibular canals in the Korean population were observed at a relatively high rate through a CBCT evaluation, and the most common type was the retromolar canal. CBCT is suggested for a detailed evaluation of bifid and trifid mandibular canals before mandibular surgery.

Intra-articular calcifications of the temporomandibular joint and associations with degenerative bone alterations

  • de Almeida, Daniela;de Souza, Patricia Schmidt Araujo Passos;de Mendonca, Luana Pereira;Verner, Francielle Silvestre;Devito, Karina Lopes
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.99-104
    • /
    • 2020
  • Purpose: The purpose of this study was to use cone-beam computed tomography (CBCT) images to determine the prevalence of calcifications in the temporomandibular joint (TMJ) and to evaluate any associations between the presence of such calcifications and degenerative bone alterations of the TMJ, sex, or age. Materials and Methods: In this retrospective study, 1,058 CBCT exams were analyzed, and data regarding the presence and quantity of calcifications, the affected side, any degenerative alterations of the condyle, sex, and age were collected. To evaluate associations between the presence of calcifications and sex or age, the Fisher exact test or the Spearman correlation coefficient, respectively, was used. To assess the association between the presence of calcifications and joint bone alterations, the chi-square and Fisher exact tests were used. The significance level adopted was 5% (P<0.05). Results: Twenty-eight patients (2.7%) presented with TMJ calcifications, including 23 women (82.1%) and 5 men (17.9%). Significant correlations were found between the presence of calcifications and age (P<0.05) and between the presence of calcifications and the presence of condylar alterations (P<0.05), with 73.2% of patients with bone alterations having TMJ calcifications. Conclusion: It may be concluded that, although rare (with a prevalence of only 2.7%), intra-articular calcifications are associated with both degenerative bone alterations and age.

Effects of various cone-beam computed tomography settings on the detection of recurrent caries under restorations in extracted primary teeth

  • Kamburoglu, Kivanc;Sonmez, Gul;Berktas, Zeynep Serap;Kurt, Hakan;Ozen, Dogukan
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.109-115
    • /
    • 2017
  • Purpose: The aim of this study was to assess the ex vivo diagnostic ability of 9 different cone-beam computed tomography (CBCT) settings in the detection of recurrent caries under amalgam restorations in primary teeth. Materials and Methods: Fifty-two primary teeth were used. Twenty-six teeth had dentine caries and 26 teeth did not have dentine caries. Black class II cavities were prepared and restored with amalgam. In the 26 carious teeth, recurrent caries were left under restorations. The other 26 intact teeth that did not have caries served as controls. Teeth were imaged using a $100{\times}90-mm$ field of view and a 0.2-mm voxel size with 9 different CBCT settings. Four observers assessed the images using a 5-point scale. Kappa values were calculated to assess observer agreement. CBCT settings were compared with the gold standard using a receiver operating characteristic analysis. The area under the curve (AUC) values for each setting were compared using the chi-square test, with a significance level of ${\alpha}=.05$. Results: Intraobserver kappa values ranged from 0.366 to 0.664 for observer 1, from 0.311 to 0.447 for observer 2, from 0.597 to 1.000 for observer 3, and from 0.869 to 1 for observer 4. Furthermore, interobserver kappa values among the observers ranged from 0.133 to 0.814 for the first reading and from 0.197 to 0.805 for the second reading. The highest AUC values were found for setting 5 (0.5916) and setting 3 (0.5886), and were not found to be statistically significant(P>.05). Conclusion: Variations in tube voltage and tube current did not affect the detection of recurrent caries under amalgam restorations in primary teeth.

Reactive oxygen species increase neuronal excitability via activation of nonspecific cation channel in rat medullary dorsal horn neurons

  • Lee, Hae In;Park, Byung Rim;Chun, Sang Woo
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.21 no.4
    • /
    • pp.371-376
    • /
    • 2017
  • The caudal subnucleus of the spinal trigeminal nucleus (medullary dorsal horn; MDH) receives direct inputs from small diameter primary afferent fibers that predominantly transmit nociceptive information in the orofacial region. Recent studies indicate that reactive oxygen species (ROS) is involved in persistent pain, primarily through spinal mechanisms. In this study, we aimed to investigate the role of xanthine/xanthine oxidase (X/XO) system, a known generator of superoxide anion ($O_2{^-}$), on membrane excitability in the rat MDH neurons. For this, we used patch clamp recording and confocal imaging. An application of X/XO ($300{\mu}M/30mU$) induced membrane depolarization and inward currents. When slices were pretreated with ROS scavengers, such as phenyl N-tert-butylnitrone (PBN), superoxide dismutase (SOD), and catalase, X/XO-induced responses decreased. Fluorescence intensity in the DCF-DA and DHE-loaded MDH cells increased on the application of X/XO. An anion channel blocker, 4,4-diisothiocyanatostilbene-2,2-disulfonic acid (DIDS), significantly decreased X/XO-induced depolarization. X/XO elicited an inward current associated with a linear current-voltage relationship that reversed near -40 mV. X/XO-induced depolarization reduced in the presence of $La^{3+}$, a nonselective cation channel (NSCC) blocker, and by lowering the external sodium concentration, indicating that membrane depolarization and inward current are induced by influx of $Na^+$ ions. In conclusion, X/XO-induced ROS modulate the membrane excitability of MDH neurons, which was related to the activation of NSCC.

Spiral scanning imaging and quantitative calculation of the 3-dimensional screw-shaped bone-implant interface on micro-computed tomography

  • Choi, Jung-Yoo Chesaria;Choi, Cham Albert;Yeo, In-Sung Luke
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.4
    • /
    • pp.202-212
    • /
    • 2018
  • Purpose: Bone-to-implant contact (BIC) is difficult to measure on micro-computed tomography (CT) because of artifacts that hinder accurate differentiation of the bone and implant. This study presents an advanced algorithm for measuring BIC in micro-CT acquisitions using a spiral scanning technique, with improved differentiation of bone and implant materials. Methods: Five sandblasted, large-grit, acid-etched implants were used. Three implants were subjected to surface analysis, and 2 were inserted into a New Zealand white rabbit, with each tibia receiving 1 implant. The rabbit was sacrificed after 28 days. The en bloc specimens were subjected to spiral (SkyScan 1275, Bruker) and round (SkyScan 1172, SkyScan 1275) micro-CT scanning to evaluate differences in the images resulting from the different scanning techniques. The partial volume effect (PVE) was optimized as much as possible. BIC was measured with both round and spiral scanning on the SkyScan 1275, and the results were compared. Results: Compared with the round micro-CT scanning, the spiral scanning showed much clearer images. In addition, the PVE was optimized, which allowed accurate BIC measurements to be made. Round scanning on the SkyScan 1275 resulted in higher BIC measurements than spiral scanning on the same machine; however, the higher measurements on round scanning were confirmed to be false, and were found to be the result of artifacts in the void, rather than bone. Conclusions: The results of this study indicate that spiral scanning can reduce metal artifacts, thereby allowing clear differentiation of bone and implant. Moreover, the PVE, which is a factor that inevitably hinders accurate BIC measurements, was optimized through an advanced algorithm.

Accuracy and reproducibility of landmark of cone beam computed tomography (CT) synthesized cephalograms (Cone beam computed tomography로 합성된 두부규격 방사선사진에서의 각 계측점의 정확도와 재현성에 관한 연구)

  • Kwon, Dae-Keun;Min, Seung-Ki;Jun, In-Chul;Paeng, Jun-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.78-86
    • /
    • 2010
  • Introduction: Cone beam computed tomography (CBCT) has various advantages and is used favorably in many fields in dentistry. Especially, CBCT is being used as basic diagnostic tool for 3-dimensional analysis in orthognathic patient. Two-dimensional cephalograms can be synthesized from CBCT digital imaging and communications in medicine (DICOM) data. In this study, conventional cephalograms and CBCT were taken simultaneously, and representative landmarks were located and analyzed in its accuracy and reproducibility. Materials and Methods: Ten patients who had orthognathic surgery in Wonkwang University Daejeon Dental Hospital participated in this study. For each patient, CBCT and conventional cephalogram was taken. By using Ondemand (Cybermad, Korea), 2-dimensional cephalograms was established on CBCT. In addition, 19 landmarks were designated and measured by 3 orthodontists twice a week. After these landmarks were transferred to a coordinate, distance of landmark and axis, standard error, distribution degree were measured, compared and analyzed. Results: Comparing the CT ceph group and conventional cephalogram group, CT ceph group had shown shorter distance of landmark and axis in S, Hinge axis, Bpt, Ba, Or, Corpus left. Standard error of the mean shows that CT ceph group has better reproducibility in Or, Corpus left, Hinge axis at X axis and Na, U1R, U1T, Bpt, PNS, Ba Corpus left, Hinge axis at Y axis. In both groups, mean error was less than 1.00 mm, no significant difference were found between CT ceph group and conventional cephalogram group in all measurements. Furthermore, comparing two groups, each 17 landmarks out of 19 had its characteristic in distribution degree. Conclusion: No significant difference were found between CBCT composed cephalographic radiograph and conventional cephalograghic radiograph, clinical application may be possible if improved.

Risk factors of osteonecrosis of the jaw after tooth extraction in osteoporotic patients on oral bisphosphonates

  • Jeong, Ho-Gul;Hwang, Jae Joon;Lee, Jeong-Hee;Kim, Young Hyun;Na, Ji Yeon;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.45-50
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the incidence of bisphosphonate-related osteonecrosis of the jaw (BRONJ) after tooth extraction in patients with osteoporosis on oral bisphosphonates in Korea and to evaluate local factors affecting the development of BRONJ. Materials and Methods: The clinical records of 320 patients who underwent dental extraction while receiving oral bisphosphonates were reviewed. All patients had a healing period of more than 6 months following the extractions. Each patient's clinical record was used to assess the incidence of BRONJ; if BRONJ occurred, a further radiographic investigation was carried out to obtain a more definitive diagnosis. Various local factors including age, gender, extraction site, drug type, duration of administration, and C-terminal telopeptide (CTx) level were retrieved from the patients' clinical records for evaluating their effect on the incidence of BRONJ. Results: Among the 320 osteoporotic patients who underwent tooth extraction, 11 developed BRONJ, reflecting an incidence rate of 3.44%. Out of the local factors that may affect the incidence of BRONJ, gender, drug type, and CTx level showed no statistically significant effects, while statistically significant associations were found for age, extraction site, and duration of administration. The incidence of BRONJ increased with age, was greater in the mandible than the maxilla, and was associated with a duration of administration of more than 3 years. Conclusion: Tooth extraction in patients on oral bisphosphonates requires careful consideration of their age, the extraction site, and the duration of administration, and close postoperative follow-up should be carried out to facilitate effective early management.

Prevalence and location of the posterior superior alveolar artery using cone-beam computed tomography

  • Tehranchi, Maryam;Taleghani, Ferial;Shahab, Shahriar;Nouri, Arash
    • Imaging Science in Dentistry
    • /
    • v.47 no.1
    • /
    • pp.39-44
    • /
    • 2017
  • Purpose: Insufficient knowledge of the anatomy of the maxillary sinuses prior to sinus graft surgery may lead to perioperative or postoperative complications. This study sought to characterize the position of the posterior superior alveolar artery (PSAA) within the maxillary sinuses using cone-beam computed tomography (CBCT). Materials and Methods: A total of 300 patients with edentulous posterior maxillae, including 138 females and 162 males with an age range of 33-86 years, who presented to a radiology clinic between 2013 and 2015 were enrolled in this retrospective cross-sectional study. The distance from the inferior border of the PSAA to the alveolar crest according to the residual ridge classification by Lekholm and Zarb, the distance from the PSAA to the nasal septum and zygomatic arch, and the diameter and position of the PSAA were all assessed on patients' CBCT scans. The data were analyzed using the Mann-Whitney test and the t-test. Results: The PSAA was detected on the CBCT scans of 87% of the patients; it was located beneath the sinus membrane in 47% of cases and was intraosseous in 47% of cases. The diameter of the artery was between 1 and 2 mm in most patients (72%). The mean diameter of the artery was $1.29{\pm}0.39mm$, and the mean distances from the PSAA to the zygomatic arch, nasal septum, and alveolar crest were $22.59{\pm}4.89mm$, $26.51{\pm}3.52mm$, and $16.7{\pm}3.96mm$, respectively. Conclusion: The likelihood of detecting the PSAA on CBCT scans is high; its location is intraosseous or beneath the sinus membrane in most patients. Determining the exact location of the PSAA on CBCT scans preoperatively can help prevent it from being damaged during surgery.

Effect of different grinding burs on the physical properties of zirconia

  • Lee, Kyung-Rok;Choe, Han-Cheol;Heo, Yu-Ri;Lee, Jang-Jae;Son, Mee-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.137-143
    • /
    • 2016
  • PURPOSE. Grinding with less stress on 3Y-TZP through proper selection of methods and instruments can lead to a long-term success of prosthesis. The purpose of this study was to compare the phase transformation and physical properties after zirconia surface grinding with 3 different grinding burs. MATERIALS AND METHODS. Forty disc-shaped zirconia specimens were fabricated. Each Ten specimens were ground with AllCeramic SuperMax (NTI, Kahla, Germany), Dura-Green DIA (Shofu Inc., Kyoto, Japan), and Dura-Green (Shofu Inc., Kyoto, Japan). Ten specimens were not ground and used as a control group. After the specimen grinding, XRD analysis, surface roughness test, FE-SEM imaging, and biaxial flexural strength test were performed. RESULTS. After surface grinding, small amount of monoclinic phase in all experimental groups was observed. The phase change was higher in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs. The roughness of surfaces increased in specimens, which were ground with Dura-Green DIA and AllCeramic SuperMax burs than control groups and ground with Dura-Green. All experimental groups showed lower flexural strength than control group, but there was no statistically significant difference between control group and ground with Dura-Green DIA and AllCeramic SuperMax burs. The specimens, which were ground with Dura-Green showed the lowest strength. CONCLUSION. The use of dedicated zirconia-specific grinding burs such as Dura-Green DIA and AllCeramic SuperMax burs decreases the grinding time and did not significantly affect the flexural strength of zirconia, and therefore, they may be recommended. However, a fine polishing process should be accompanied to reduce the surface roughness after grinding.