A RADIOGRAPHIC STUDY OF THE EXPERIMENTAL LESIONS IN THE MAXILLARY SINUS (상악동의 실험병소에 관한 X선학적 연구)

  • Lee Joo Hyun;Hwang Eui Hwan;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.115-124
    • /
    • 1994
  • The purpose of this study was to examine the differences in representation of a globular radiopaque mass on the pantomograms and Waters' views and to compare the efficacy of periapical radiograms, pantomograms and Waters' views in detection of defects on the internal walls of the maxillary sinus. This study was performed with dried human skull. For the study of difference of radiopaque mass shadow in the two views, rubber ball with a diameter of 10㎜ was used as the experimental lesion. It was placed successively on the internal wall of the anterior, posterior, medial, lateral walls and floor of the maxillary sinus. To examine the detectability of defects for radiographic techniques, defects were formed in the anterior, posterior, medial, lateral walls, and floor of the maxillary sinus. They were formed with 0.5㎜, 0.75㎜, 1.0㎜, 2.0㎜ and 3.0㎜ sized steel round burs with a slow speed dental handpiece. By subsequently plugging the holes with zinc oxide eugenol paste, radiopaque defects were produced. After that the periapical radiograms, the pantomograms and the Waters' views were taken each and every defect. The obtained results were as follows: 1. Rubber balls placed on each internal wall of the maxillary sinus were correctly depicted on the posterior wall and the floor in case of the pantomogram, and on the anterior wall and the medial wall in case of the Waters' view. 2. On the detectability of defects for each radiographic technique, radiolucent defects were detected in different places for each technique. Periapical radiogram could detect 1.0㎜ defect on the floor of the maxillary sinus, pantomogram could detect 2.0㎜ defect on every internal wall of the maxillary sinus, and Waters' view could detect 3.0㎜ defect on the anterior wall of the maxillary sinus. 3. On the detectability of defects for each radiographic technique, radiopaque defects were detected in different places for each technique. Periapical radiogram could clearly detect 0.5㎜ defect on the floor of the maxillary sinus, pantomogram could detect 0.5㎜ defect on every internal wall of the maxillary sinus, and finally Waters' view could detect 0.5㎜defect on the anterior wall of the maxillary sinus but 0.75㎜ defect on the anterior wall, lateral wall and floor of the maxillary sinus. As the result, the periapical radiogram is the most simple and satisfactory method for investigating in the maxillary sinus. The pantomogram is suitable method for screening of changes in the maxillary sinus. And the Waters' view is available for detect of lesion in the anterior wall of the maxillary sinus. For the purpose of accurate diagnosis and evaluation of lesion in the maxillary sinus, these techniques supplement each other.

  • PDF

THE EFFECT OF SMEAR LAYER REMOVAL AND POSITION OF DENTIN ON SHEAR BOND PROPERTIES OF DENTIN BONDING SYSTEMS TO INTERNAL CERVICAL DENTIN (도말층 제거와 상아질의 부위가 치수강 내부 상아질에 대한 수종 상아질 결합제의 전단결합성질에 미치는 영향)

  • Lim, Yoen-Ah;You, Young-Dae;Lee, Yong-Keun;Lee, Su-Jong;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.3
    • /
    • pp.465-472
    • /
    • 1999
  • The aim of this study was to determine the shear bond properties of four dentin bonding systems to internal cervical dentin, and to investigate the effect of the pretreatment for removing smear layer and position of dentin on shear bond strength of dentin bonding agents. The materials tested in this study were consisted of four commercially available dentin bonding systems[Allbond 2(AB), Clearfil Linerbond 2(CL), Optibond FL(OP), Scotchbond Multi-purpose(SB)], a restorative light-cured composite resin[Z100]J and a chelating agent[RC-prep(RC)]. Fifty-six freshly extracted human molars were used in this study. Dentin specimens were prepared by first cutting the root of the tooth 1mm below the cementoenamel junction with a diamond bur in a high speed handpiece under air-water coolant, and then removing occlusal part at pulp horn level by means of a second parallel section, The root canal areas were exposed by means of cutting the dent in specimens perpendicular to the root axis. Dentin specimens were randomly assigned to two groups(pretreated group, not-pretreated group) based on the pretreatment method of dentin surface. In pretreated group, RC was applied to dentin surface for 1minute and then rinsed with NaOCl. In not-pretreated group, dentin surface was rinsed with saline Each groups were subdevided into four groups according to dentin bonding systems. Four dentin bonding systems and a restorative resin were applied according to the directions of manufacturer. The dentin-resin specimens were embedded in a cold cure acrylic resin, and were cut with a low speed diamond saw to the dimension of $1{\times}1mm$. The cut specimens were divided into three groups according to the position of internal cervical dentin. The shear bond properties of dentin-resin specimens were measured with Universal testing machine (Zwick, 020, Germany) with the cross head speed of 0.5mm/min. From this experiment. the following results were obtained : 1. In case of shear bond strength, there was no significant difference among dentin bonding systems in not-pretreated groups, whereas in pretreated groups, the shear bond strengths of AB and of SB were statistically significantly higher than those of CL and of OP. 2. The shear bond strengths of AB and of SB in pretreated groups were significantly higher than those in not-pretreated groups. 3. The shear bond strengths of radicular layer of OP were higher than those of occlusal layer of OP in not-pretreated groups, and of AB in pretreated groups. The shear bond strengths of radicular layer of AB and of CL in not-pretreated groups were higher than those in pretreated group.

  • PDF

A SCANNING ELECTRON MICROSCOPIC STUDY ON THE MARGINAL ADAPTIBILITY IN APPLYING THE CAVITY VARNISH AND DENTIN BONDING AGENT IN AMALGAM RESTORATIONS (아말감 수복시(修復時) Cavity varnish와 Bonding agent 도포(塗布)에 따른 접합성(接合性)에 관(關)한 주사전자현미경적(走査電子顯微鏡的) 연구(硏究))

  • Kim, Seok-Hoon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.107-119
    • /
    • 1990
  • The purpose of this study was to evaluate the marginal adaptability of the amalgam restorations in applying the cavity varnish (Copalite$^{(R)}$) and dentin bonding agent (Scotchbond 2$^{(R)}$) under the scanning electron microscope. For this study, eighteen sound extracted human molars were selected. Class I cavities in 12 teeth and class V cavities in 6 teeth were prepared using an air turbine with No. 701 tungsten carbide bur and finished using a low speed handpiece with No. 557 fissure bur. The prepared specimens were then divided into three groups including 4 class I cavities and 2 class V cavities in each group and restored as follows ; Group I. All the prepared cavities were restored with amalgam only (Control). Group II. Two layers of Copalite$^{(R)}$ cavity varnish were applied to the cavities with a gentle stream of air after each application and cavities were restored with amalgam. Group III. The enamel cavity margins were etched with 37% phosphoric acid gel for 60 sec., rinsed for 30 sec. and dried. One layer of visible lightcured Scotchbond Dental Adhesive$^{(R)}$ was applied and immediately cured for 20 seconds with visible light-cure unit and cavities were restored with amalgam. All the specimens were cut at the neck of the teeth and the occlusal halves of specimens were sectioned buccolingually in the longitudinal axis centering the amalgam restorations, using the disk. The cut specimens were ground with sandpapers (400, 600, 800, 1000 grit), and cleaned for 5 minutes in the ultrasonic cleaner (Brason Co. U.S.A.). In the cut surfaces, the amalgam - tooth interfaces were examined under the scanning electron microscope (JSM, 35C type, JEOL). The obtained results were as follows ; 1. The amalgam-tooth interfaces were reduced more significantly in the Copalite$^{(R)}$ and Scotchbond 2$^{(R)}$ application group than in the control group. 2. In the class I cavities, the Scotchbond 2$^{(R)}$ application group showed the findings similar to the Copalite$^{(R)}$ application group in the cavity floor, and the marginal adaptability was better in the side wall than in the cavity floor. 3. In the class I cavities, the Scotchbond 2$^{(R)}$ application group showed better marginal adaptability in the occlusal margin than in the gingival margin. 4. The marginal adaptability was in the order of the Scothbond 2$^{(R)}$ application group, the Copalite$^{(R)}$ application group and the control group.

  • PDF

COMPARISON OF MONOMER RELEASE FROM PIT AND FISSURE SEALANT FOLLOWING VARIOUS SURFACE TREATMENT (치면열구전색제의 광중합 후 표면 처리 방법에 따른 미반응 모노머 용리 비교)

  • Lee, Sang-Woo;Lee, Ju-Hyun;Seo, Hyun-Woo;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.70-76
    • /
    • 2006
  • The aim of this study was comparison of effectiveness of surface treatment methods in reducing the oxygen-inhibited layer of a commercially available freshly polymerized, light cured dental sealant($concise^{TM}$, 3M, St Paul, USA). Surface treatment groups were consisted of no treatment(negative control group) and 3 experimental groups according to surface treatment of light-cured sealant. Experimental group I was 10 seconds' exposure to distilled water syringe, group II was 10 seconds' manual application using a cotton pellet wetted with 75% alcohol and group III was 10 seconds' prophylaxis with pumice/water slurry using rubber cup on a slow-speed handpiece. All specimens were immersed in 5ml distilled water and stored at 37c water bath for 10 minutes. All eluates were analyzed by HLPC for identification and quantitive analysis of monomers. The results of this study can be summarized as follows. 1. None of the chromatograms of the tested sealant displayed peaks with the same retention time as that of the standard solution, except for TEGDMA. 2. All surface treatment group had a statistically significant decrease of monomer release in comparison with no treatment group. 3. Removal effects of unreacted monomer in group III was statistically significant in comparison with group I and group II. These results revealed that mechanical method using pumice and rubber cup is the most effective in removing residual monomer and may be valuable to be used effectively in clinic.

  • PDF

Temperature change and performance of bur efficiency for two different drill combinations (두 가지 임플란트 드릴 조합에 따른 온도 변화 및 효율 비교)

  • Hwang-Bo, Heung;Park, Jae-Young;Lee, Sang-Youn;Son, Keunbada;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.143-151
    • /
    • 2022
  • Purpose. The purpose of this study was to evaluate the performance efficiency of two different drill combinations according to the heat generated and drilling time. Materials and methods. In this study, cow ribs were used as research materials. To test the specimen, cow bones were rid of fascia and muscles, and a temperature sensor was mounted around the drilling area. The experimental group was divided into a group using a guide drill and a group using a Lindmann drill according to the drill used before the initial drilling. The drilling sequence of the guide drilling group is as follows; guide drill (ø 2.25), initial drill (ø 2.25), twist drill (ø 2.80), and twist drill (ø 3.20). The drilling sequence of the Lindmann drilling group is as follows; Lindmann drill (ø 2.10), initial drill (ø 2.25), twist drill (ø 2.80), and twist drill (ø 3.20). The temperature was measured after drilling. For statistical analysis, the difference between the groups was analyzed using the Mann-Whitney U test and the Friedman test was used (α = .05). Results. The average performance efficiency for each specimen of guide drilling group ranged from 0.3861 to 1.1385 mm3/s and that of Lindmann drilling group ranged from 0.1700 to 0.4199 mm3/s. The two drill combinations contained a guide drill and Lindmann drill as their first drills. The combination using the guide drill demonstrated excellent performance efficiency when calculated using the drilling time (P < .001). Conclusion. Since the guide drill group showed better performance efficiency than the Lindmann drill group, the use of the guide drill was more suitable for the primary drilling process.

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

Pulp Response of Mineral Trioxide Aggregate, Calcium Sulfate or Calcium Hydroxide (Mineral trioxide aggregate, calcium sulfate와 calcium hydroxide의 치수에 대한 반응)

  • Yun, Young-ran;Yang, In-Seok;Hwang, Yun-Chan;Hwang, In-Nam;Choi, Hong-Ran;Yoon, Suk-Ja;Kim, Sun-Hun;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.95-101
    • /
    • 2007
  • This study was performed to verify the possibility of MTA and calcium sulfate as a pulp capping agent through comparing the dental pulp response in dogs after capping with MTA, calcium sulfate, and calcium hydroxide. 24 teeth of 2 dogs, 8 month old, were used in this study. Under general anesthesia, cervical cavities were prepared and pulp was exposed with sterilized #2 round bur in a high speed handpiece. MTA calcium hydroxide, and calcium sulfate were applied on the exposed pulp. Then the coronal openin,fs were sealed with IRM and light-cured composite. Two months after treatment, the animals were sacrificed. The extracted teeth were fixed in 10% neutral-buffered formalin solution and were decalcified in formic acid-sodium citrate. They were prepared for histological examination in the usual manner. The sections were stained with haematoxylin and eosin. In MTA group, a hard tissue bridges formation and newly formed odontoblasts layer was observed. There was no sign of pulp inflammatory reaction in pulp tissue. In calcium hydroxide group, there was no odontoblast layer below the dentin bridge. In pulpal tissue, chronic inflammatory reaction with variable intensity and extension occurred in all samples. In calcium sulfate group, newly formed odontoblast layer was observed below the bridge. Mild chronic inflammation with a few neutrophil infiltrations was observed on pulp tissue. These results suggest that MTA is more biocompatible on pulp tissue than calcium hydroxide or calcium sulfate.