• 제목/요약/키워드: Dental computer aided design-computer aided manufacturing

검색결과 154건 처리시간 0.026초

치과용 스케일러 금형의 분말사출성형 CAE 해석설계 (CAE Analysis of Powder Injection Molding Process for Dental Scaler Mold)

  • 고영배;박형필;정성택;이병옥;황철진
    • 소성∙가공
    • /
    • 제14권6호
    • /
    • pp.570-576
    • /
    • 2005
  • Powder Injection Molding(PIM) has recently been recognized as an advanced manufacturing technology for low-cost mass production of metal or ceramic parts of complicated geometry With this regards, design technology of dental scaler tip PIM mold, which has complex shape and small core pin (diameter=0.6mm), with the help of computer-aided analysis of powder injection molding process was developed. Computer-aided analysis for dental scaler tip mold was implemented by finite element method with non-Newtonian fluid, modified Cross model viscosity, PvT data of powder/binder mixture. Compter-aided analysis results, such as filling pattern, weldline formation, air vent position prediction were compared with experimental result, and eventually have been shown good agreement. The core pin (diameter=0.6mm) deflection analysis of dental scaler tip PIM mold during PIM filling process was also investigated before mold fabrication.

Computer Aided Engineering Design of Power Injection Molding Process for Dental Scaler Top Mold Design

  • Hwang, C.J.;Ko, Y.B.;Park, H.P.;Chung, S.T.;Rhee, B.O.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.497-498
    • /
    • 2006
  • Powder Injection Molding (PIM) has recently been recognized as an advanced manufacturing technology for low-cost mass production of metal or ceramic parts of complicated geometry. With this regards, design technology of dental scaler tip PIM mold, which has complex shape, with the help of computer-aided analysis for powder injection molding process was developed. Compter aided analysis results, such as filling pattern, weldline formation, and air vent position prediction were investigated and eventually showed good agreements with experimental results.

  • PDF

Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards

  • Jeon, Jin-Hun;Hwang, Seong-Sig;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.335-339
    • /
    • 2018
  • PURPOSE. The purpose of the present study was to compare scanning trueness and precision between an abutment impression and a stone model according to dental computer-aided design/computer-aided manufacturing (CAD/CAM) evaluation standards. MATERIALS AND METHODS. To evaluate trueness, the abutment impression and stone model were scanned to obtain the first 3-dimensional (3-D) stereolithography (STL) file. Next, the abutment impression or stone model was removed from the scanner and re-fixed on the table; scanning was then repeated so that 11 files were obtained for each scan type. To evaluate precision, the abutment impression or stone model was scanned to obtain the first 3-D STL file. Without moving it, scanning was performed 10 more times, so that 11 files were obtained for each scan type. By superimposing the first scanned STL file onto the other STL files one by one, 10 color-difference maps and reports were obtained; i.e., 10 experimental scans per type. The independent t-test was used to compare root mean square (RMS) data between the groups (${\alpha}=.05$). RESULTS. The $RMS{\pm}SD$ values of scanning trueness of the abutment impression and stone model were $22.4{\pm}4.4$ and $17.4{\pm}3.5{\mu}m$, respectively (P<.012). The $RMS{\pm}SD$ values of scanning precision of the abutment impression and stone model were $16.4{\pm}2.9$ and $14.6{\pm}1.6{\mu}m$, respectively (P=.108). CONCLUSION. There was a significant difference in scanning trueness between the abutment impression and stone model, as evaluated according to dental CAD/CAM standards. However, all scans showed high trueness and precision.

Accuracy of lingual fixed retainers fabricated using a CAD/CAM bending machine

  • Fu Ping Cui;Jung-Jin Park;Seong-Hun Kim
    • 대한치과교정학회지
    • /
    • 제54권4호
    • /
    • pp.257-263
    • /
    • 2024
  • Objective: Lingual fixed retainers, made from 0.0175-inch 3-strand twisted stainless steel wire (TW) and 0.016 × 0.022-inch straight rectangular wire (RW), are generally used in clinical practice. This study aimed to calculate their accuracy by comparing the discrepancy between computer-aided customized retainers made from these two types of wires. Methods: Eleven orthodontic patients were selected, resulting in 22 maxillary and mandibular three-dimensional printing dental models. Two types of lingual fixed retainers were bonded from canine to canine. To determine the accuracy, five points were chosen for each model, resulting in 110 selected points. The absolute values of the distances on the x-, y-, and z-axes were measured to compare the accuracy of the two types of computer-aided retainers. Results: The accuracy of the two types of retainers did not differ significantly in the x- and z-axes, but only in the y-axis (P < 0.01), where RW-fixed retainers exhibited a slightly but significantly increased distance compared to the TW. Conclusions: Both types of retainers showed high accuracy; however, RW had a slight but statistically significant difference along the y-axis compared with TW. This type of computer-aided design/computer-aided manufacturing bending machine is limited to two dimensions, and the dental arch is curved. Therefore, RW may require slight manual adjustment by the practitioner after manufacturing.

Implant-Guided Surgery를 이용한 고정성 임플란트 보철물의 전악 수복 증례 (Full mouth rehabilitation with Implant-Guided Surgery and Fixed prosthesis)

  • 김성모;박진홍;류재준;신상완;이정열
    • 대한치과보철학회지
    • /
    • 제56권2호
    • /
    • pp.126-133
    • /
    • 2018
  • Cone beam computerized tomography (CBCT)의 발전은 환자의 해부학적 구조를 3차원적으로 분석할 수 있게 하였다. Surgical guide는 CBCT와 CAD/CAM, 임플란트 진단 소프트웨어의 접목을 통해 미래의 보철물을 계획하고 적합한 위치에 임플란트를 식립할 수 있게 한다. Guided surgery를 통해 해부학적 구조물에 대한 침범을 최소한으로 줄일 수 있고 보다 재현성 있는 치료계획의 설정이 가능하다. 본 증례는 전악 무치악 환자에게 surgical guide를 이용하여 다수의 임플란트를 식립한 증례로 수술시간을 단축시킬 수 있었으며 임시 보철물을 미리 제작함으로써 보다 쉽게 immediate loading을 시행할 수 있었다. 환자는 개선된 안모와 저작기능에 만족하였다.

Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study

  • Hyunsuk Choi;Jae-Young Jo;Min-Ho Hong
    • Journal of Yeungnam Medical Science
    • /
    • 제41권2호
    • /
    • pp.80-85
    • /
    • 2024
  • Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.

구치부 지지 소실 및 무너진 교합관계를 보이는 환자에서 Dental CAD-CAM system을 활용한 완전 구강 회복 증례 (Full-mouth rehabilitation of a patient with loss of posterior support and collapsed occlusion utilizing dental CAD-CAM system)

  • 정지원;허성주;김성균;곽재영
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.44-54
    • /
    • 2022
  • 다수 치아의 상실 상태로 장시간 지속시 구치부 지지의 부족 및 치아들의 과정출이 발생되어 교합 부조화, 수직고경 상실 및 기능 장애 등의 심각한 문제가 초래된다. 본 증례는 장기간 다수치아 결손으로 인하여 대합치가 정출하면서 교합평면의 붕괴가 일어난 환자의 완전 구강 회복에 관한 증례이다. 상기 환자는 서울대학교 치과병원 치과보철과로 내원한 68세 남환으로 오래된 상악 의치를 빼다가 치아가 함께 발거되었으며, 하악 전치부가 상악 전치부와 강하게 닿아서 불편함을 호소하며 내원하였다. 여러가지 평가를 통해 수직고경을 4 mm 거상하였으며, 무치악부는 진단 및 치료계획시 설계한 최종 보철 수복물 제작을 고려하여 정확한 임플란트 식립을 위해 CAD-CAM (Computer-aided design-computer-aided manufacturing) 기술을 이용한 Computer guided implant surgery를 시행하고, 임플란트 고정성 보철 수복으로 진행하였고, 환자는 저작, 기능 및 심미 모두 큰 개선에 만족하였다.

Fabrication of a CAD/CAM monolithic zirconia crown to fit an existing partial removable dental prosthesis

  • Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Lee, Hyeonjong;Kim, Hyeong-Seob
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.329-332
    • /
    • 2016
  • Fabricating a surveyed prosthesis beneath an existing partial removable dental prosthesis (PRDP) is a challenging and time-consuming procedure. The computer-aided design/computer-assisted manufacturing (CAD/CAM) technology was applied to fabricate a retrofitted, surveyed zirconia prosthesis to an existing PRDP. CAD/CAM technology enabled precise and easy replication of the contour of the planned surveyed crown on the existing abutment tooth. This technology ensured excellent adaptation and fit of newly fabricated crown to the existing PRDP with minimal adjustments. In this case report, a seventy-year-old male patient presented with fractured existing surveyed crown. Because the existing PRDP was serviceable, new crown was fabricated to the existing PRDP.

CAD/CAM으로 제작된 지르코니아 코어의 지대치 형태에 따른 변연 및 내면 적합도에 관한 연구 (Marginal and internal fit according to the shape of the abutment of a zirconia core manufactured by computer-aided design/computer-aided manufacturing)

  • 김지수;류재경
    • 대한치위생과학회지
    • /
    • 제5권1호
    • /
    • pp.13-19
    • /
    • 2022
  • Background: In this study, zirconia copings were fabricated by setting clinically acceptable inner values for prostheses using computer-aided design/computer-aided manufacturing (CAD/CAM). The processed copings were evaluated for the marginal and internal fit of each abutment shape with a CAD program using the silicone replica technique. Methods A total of 20 copings was produced by selecting models commonly used in clinical practice. After injecting the sample, the minimum thickness, internal adhesion interval, and distance to the margin line were set to 0.5, 0.05, and 1.00 mm using a dental CAD program, respectively. It was measured using a 2D section function in a three-way program of the silicon replication technology. Although the positions and number of measurements of the anterior and posterior regions differed, nine parts of each pre-tube were designated and measured by referring to a previous study to compare the two samples. Results As a result, the average margin of the mesial, distal, and buccal (labial) surfaces was 59.90 ㎛ in the anterior region and 60.40 ㎛ in the posterior region. The mean axial wall margin was 67.25 ㎛ in the anterior region and 69.25 ㎛ in the posterior region. In occlusion, the anterior teeth (77.70 ㎛), posterior teeth (77.60 ㎛), and both anterior and posterior regions were within the clinically acceptable range. Conclusion The edge and inner fit of zirconia coping manufactured using the CAD/CAM system showed clinically applicable results. To reduce errors and increase accuracy, materials and machine errors that affect the manufacture of prosthetics should be investigated. Based on our results, the completeness of prosthetics could increase if the inner value and characteristics of the material are adjusted when applied in clinical practice.

Recent advances in dental implants

  • Hong, Do Gia Khang;Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제39권
    • /
    • pp.33.1-33.10
    • /
    • 2017
  • Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.