• Title/Summary/Keyword: Dental composite resins

Search Result 166, Processing Time 0.022 seconds

Examples of clinical applications of flexible composite resin that is quite different from conventional composite resins (Conventional composite resin과 사뭇 다른 flexible composite resin의 여러 임상 활용 예)

  • Kim, Woohyun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.29 no.2
    • /
    • pp.92-102
    • /
    • 2020
  • Bond-Fill SB is made of powder/liquid, and the flowability can be controlled by adjusting the amount of liquid in the brush. Thanks to the strong catalyst called TBB, it has the advantage of being able to polymerize even in the presence of water and oxygen. Also, since it contains 4-META, it has the advantage of being able to adhere to metals and ceramics with appropriate surface treatment. If you fully understand these advantages, you can actively utilize them in cases where it is difficult to treat with conventional composite resin.

Discoloration of various CAD/CAM blocks after immersion in coffee

  • Lauvahutanon, Sasipin;Shiozawa, Maho;Takahashi, Hidekazu;Iwasaki, Naohiko;Oki, Meiko;Finger, Werner J.;Arksornnukit, Mansuang
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.1
    • /
    • pp.9-18
    • /
    • 2017
  • Objectives: This study evaluated color differences (${\Delta}Es$) and translucency parameter changes (${\Delta}TPs$) of various computer-aided design/computer-aided manufacturing (CAD/CAM) blocks after immersion in coffee. Materials and Methods: Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE $L^{\ast}a^{\ast}b^{\ast}$ values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6). The ${\Delta}Es$ and ${\Delta}TPs$ of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (${\alpha}=0.05$). The ${\Delta}Es$ after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results: After one month in coffee, ${\Delta}Es$ of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ${\Delta}TPs$ decreased. The ANOVA of ${\Delta}Es$ and ${\Delta}TPs$ revealed significant differences in two main factors, immersion periods and media, and their interaction except for ${\Delta}Es$ of TEL (Telio CAD, Ivoclar Vivadent). The ${\Delta}Es$ significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC). There was no significant correlation between ${\Delta}Es$ and water sorption or solubility in water. Conclusions: The ${\Delta}Es$ of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

Effects of surrounding and underlying shades on the color adjustment potential of a single-shade composite used in a thin layer

  • Mariana Silva Barros;Paula Fernanda Damasceno Silva;Marcia Luciana Carregosa Santana;Rafaella Mariana Fontes Braganca;Andre Luis Faria-e-Silva
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.7.1-7.10
    • /
    • 2023
  • Objectives: This study aimed to evaluate the surrounding and underlying shades' effect on the color adjustment potential (CAP) of a single-shade composite used in a thin layer. Materials and Methods: Cylinder specimens (1.0 mm thick) were built with the Vittra APS Unique composite, surrounded (dual specimens) or not (simple specimens) by a control composite (shade A1, A2, or A3). Simple specimens were also built only with the control composites. Each specimen's color was measured against white and black backgrounds or the simple control specimens with a spectrophotometer (CIELAB system). The whiteness index for dentistry (WID) and translucency parameters (TP00) were calculated for simple specimens. Differences (ΔE00) in color between the simple/dual specimens and the controls were calculated. The CAP was calculated based on the ratios between data from simple and dual specimens. Results: The Vittra APS Unique composite showed higher WID and TP00 values than the controls. The highest values of ΔE00 were observed among simple specimens. The color measurements of Vittra APS Unique (simple or dual) against the control specimens presented the lowest color differences. Only surrounding the single-shade composite with a shaded composite barely impacted the ΔE00. The highest CAP values were obtained using a shaded composite under simple or dual specimens. Conclusions: The CAP of Vittra APS Unique was strongly affected by the underlying shade, while surrounding this composite with a shaded one barely affected its color adjustment.

Surface characteristics and bonding performance of polymer restorative materials for dental CAD/CAM systems (치과 캐드캠 시스템에서 사용되는 고분자 수복재료들의 표면특성과 접착양상)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.203-209
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the mechanical properties of polymer prosthetic and restorative materials for dental CAD/CAM using two test method; surface characteristics and shear bond strength. Methods: Commercialized CAD/CAM polymer blanks were investigated; One kinds of PMMA, and one PEKK blanks. A total of 20 PMMA and PEKK specimens were prepared, and each group was divided into 10 specimens. Average surface roughness was observed under surface profilometer. The contact angle was measured with a surface electrooptics. The bond strength was evaluated by a universal testing machine at a crosshead speed of 5mm/min. The data were statistically analyzed using independent t-test and Fisher's exact test(P<0.05). Results: The PMMA and PEKK group showed a significant difference in the shear bond strength with the composite resin(P<0.05). The surface roughness of the PEKK group was higher than that of the PMMA group. The fracture mode were observed in PEKK groups with 50% showing adhesive remnant index score. Conclusion: PEEK is used as substructure material and composite veneering material is applied. PEKK resins will contribute to the development of successful products that will provide structural and aesthetic satisfaction.

Thickness and translucency of opaque shade composite resin for masking effect (배경 색조 차단 목적의 불투명 복합 레진의 두께와 반투명도)

  • Baek, Kyung-Won;Kim, Sung-Joon
    • The Journal of the Korean dental association
    • /
    • v.49 no.4
    • /
    • pp.203-210
    • /
    • 2011
  • The aims of this study were to evaluate the adequate thickness of opaque resins for situations such as an oral black cavity and discolored tooth structure, as well as the translucency of each opaque material at various thicknesses. Six opaque-shade composite resins (Z-350 OA3, Amelogen Universal A2O, Esthet-X A2O, Esthet-X A4O, Charmfil UO and Aelite Universal OA3) were prepared in metal molds with a hole of 8 mm in diameter and various thicknesses (0.5mm, 1.0mm, 1.5mm, 2.0mm, 2.5mm, 3.0 mm and 4.0mm). Four backgrounds (white tile, black tile, C4 shade porcelain and opaque resin itself) were used to determine the translucency parameter (between black and white backgrounds). and to mimic a black oral cavity (between black and opaque resin backgrounds) and a discolored tooth structure (between C4 and opaque resin backgrounds). Color measurements were made by a colorimeter to determine the CIELAB values of each specimen with each background and to calculate the translucency parameter and ${\Delta}E^*$ value difference among the specimens on the backgrounds. The translucency parameter and ${\Delta}E^*$ obtained between black and opaque resin backgrounds decreased in similar pattern as thickness increased. A C4 background was masked by resin thicknesses of 0.5-1.0mm, while a black background required thicknesses of 1.0-2.0mm. Adequate knowledge about differences in the optical character like translucency of the materials used is essential, together with the accumulated experience of the individual clinician.

Influence of mechanical properties with gingival shade composites resin according to the thermocycling treatment (열 순환 처리가 Gingival shade 복합레진의 기계적 특성에 미치는 영향)

  • Im, Yong-Woon;Hwang, Seong-Sig
    • Journal of Technologic Dentistry
    • /
    • v.39 no.2
    • /
    • pp.83-91
    • /
    • 2017
  • Purpose: The objective of this study was to evaluate influence of mechanical properties of gingival shade composite resins(GSCRs) according to thermocycling treatment. Methods: The material utilized in this study was Crea.lign(CGR), Twiny flow(TGF) and Twiny(TGP). Total sixty specimens were fabricated with a dimension of $25{\times}2{\times}2mm$ according to the ISO 4049. After fabrications, specimens of before and after thermocycling(to $55^{\circ}C$ from $5^{\circ}C$) were stored in the distilled water for 24 hours at the $37^{\circ}C$. Three-point flexural test was performed in universal testing machine(Instron 5966, USA) at a crosshead speed of 1 mm/min. Flexural strength, flexural modulus and work of fracture according to the thermocycling were analyzed using a one-way ANOVA analysis. Surface analysis of GSCRs after thermocycling evaluated using the scanning electron microscope. Results: : The highest FS was measured in TGP group of NTC group and lowest in CGR group after TC. After TC, FS and FM decreased in CGR and TGP groups, but TGF increased. There was a statistically significant difference between FS and WOF in GSCRs(p<0.05). But FM did not show any significant difference after TC (p>0.05). The strength of the characteristic exceeded the flexural strength required by ISO 4049(> 80 MPa). Weibull modulus(m) showed the highest reliability in the TGP group (m = 14.22), and the reliability of the TGF and TGP groups after TC decreased. Conclusion: Thermocycling treatment is important factor influence of mechanical properties with gingival shade composite resins. Therefore, we recommended that mechanical properties need to get useful information and accuracy for life-span expectancy according to the thermocycling treatment.

Comparison of instrumental methods for color change assessment of Giomer resins

  • Luiza de Almeida Queiroz Ferreira;Rogeli Tiburcio Ribeiro da Cunha Peixoto ;Claudia Silami de Magalhaes;Tassiana Melo Sa;Monica Yamauti ;Francisca Daniele Moreira Jardilino
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.8.1-8.9
    • /
    • 2022
  • Objectives: The aim of this study was to compare the color change of the Giomer resin composite (Beautifil-Bulk) by using photographs obtained with a smartphone (iPhone 6S) associated with Adobe Photoshop software (digital method), with the spectrophotometric method (Vita Easyshade) after immersion in different pigment solutions. Materials and Methods: Twenty resin composite samples with a diameter of 15.0 mm and thickness of 1.0 mm were confectioned in A2 color (n = 5). Photographs and initial color readings were performed with a smartphone and spectrophotometer, respectively. Then, samples were randomly divided and subjected to cycles of immersion in distilled water (control), açai, Coke, and tomato sauce, 3 times a day, 20 minutes for 7 days. Later, new photographs and color readings were taken. Results: The analysis (2-way analysis of variance, Holm-Sidak, p < 0.05) demonstrated no statistical difference (p < 0.005) between the methods in all groups. Similar color changes were observed for all pigment solutions when using the spectrophotometric method. For the digital method, all color changes were clinically unacceptable, with distilled water and tomato sauce similar to each other and with statistical differences (p < 0.005) for Coke and açai. Conclusions: Only the tomato sauce produced a color change above the acceptability threshold using both methods of color assessment. The spectrophotometric and digital methods produce different patterns of color change. According to our results, the spectrophotometric method is more recommended in color change assessment.

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

Physical Properties Effect of Dry-Heat and Microwave-Cured Acrylic Resins depending on the Irradiation-Induced Changes (유도광선변화에 따른 건식중합과 마이크로파중합 아크릴레진의 물리적 성질영향)

  • Kim, Gyu-Ri
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4388-4397
    • /
    • 2015
  • The purpose of this study was to research the property change of acrylic resins depending on the induced-beam change and research the improved physical property of dry-heat and microwave-cured dental place acrylic resin in order to develop the acrylic resins with the optimum characteristic. As a result of observing flexural rigidity, hardness and color difference, the dry-heat-cured specimens of Vertex RS and Paladent 20 showed ideal property at 5, 15, and 25 kGy irradiation. The microwave-cured specimens of Vertex RS and Paladent 20 showed ideal property at 5 kGy irradiation. The correlation analysis showed a positive correlation among ARD, flexural rigidity (0 418), E coefficient (0.675) and Barcol hardness (0 588). The radiation cure technology is helpful for relieving the contamination caused by the manufacture of polymer composite. It can significantly contribute to the fusion of ultra violet cure technology and nano technology and the improvement of mechanical property without giving effect to the workability of polymer.

Effect of immersion into solutions at various pH on the color stability of composite resins with different shades

  • Moon, Ji-Deok;Seon, Eun-Mi;Son, Sung-Ae;Jung, Kyoung-Hwa;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.4
    • /
    • pp.270-275
    • /
    • 2015
  • Objectives: This study examined the color changes of a resin composite with different shades upon exposure to water with different pH. Materials and Methods: Nanohybrid resin composites (Filtek Z350XT, 3M ESPE) with four different shades (A2, A3, B1, and B2) were immersed in water with three different pH (pH 3, 6, and 9) for 14 day. The CIE $L^*a^*b^*$ color coordinates of the specimens were evaluated before and after immersion in the solutions. The color difference (${\Delta}E^*$) and the translucency parameter (TP) were calculated using the color coordinates. Results: ${\Delta}E^*$ ranged from 0.33 to 1.58, and the values were affected significantly by the pH. The specimens immersed in a pH 6 solution showed the highest ${\Delta}E^*$ values (0.87 - 1.58). The specimens with a B1 shade showed the lowest ${\Delta}E^*$ change compared to the other shades. TP ranged from 7.01 to 9.46 depending on the pH and resin shade. The TP difference between before and after immersion in the pH solutions was less than 1.0. Conclusions: The resulting change of color of the tested specimens did not appear to be clinically problematic because the color difference was < 1.6 in the acidic, neutral, and alkaline solutions regardless of the resin shade, i.e., the color change was imperceptible.