• Title/Summary/Keyword: Dental characteristics

Search Result 2,154, Processing Time 0.033 seconds

Clinical Characteristics of Headaches in Temporomandibular Disorder Patients : Primary Headache vs Headache Attributed to TMD (측두하악장애 환자의 두통 양상의 분류 : 일차성 두통 vs 측두하악장애로 인한 두통)

  • Ryu, Ji-Won;Bae, Kook-Jin;Hong, Seong-Ju;Yoon, Chang-Lyuk;Ahn, Jong-Mo
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.3
    • /
    • pp.325-331
    • /
    • 2009
  • The objective of this study was to describe the prevalence of the headache attributed to Temporomandibular disorder(TMD) symptoms and to investigate the relationships of headache and TMD. 66 patients seeking care for signs and symptoms of Temporomandibular disorders(TMD) and Orofacial pain in the department of oral medicine, Dental Hospital, Chosun University, from January, 2008 to June, 2008, were recruited. The obtained results were as follows : 1. A muscle and TMJ origin combined was the most common in study populations(54.55%), grouped as TMD classification. 2. Tension type headache was the most common in study population(89.39%), grouped as headache classification. 3. 36 patients out of 66(54.55%) had headaches which related to TMD. 4. Out of 36 patients who had suffered the headache which were attributed to TMD, 19 patients(52.78%) described that their headache related to TMD was different from their own primary headaches. In conclusion, headache attributed to TMD is relatively common in the patients who had headaches and TMD symptoms together. And the new headache patterns may related to headache and TMD chronification. Larger-scale studies and more specified and controlled comparison study is needed to confirm the relationship between the headache and TMD.

Screening of genes differentially expressed in cultured human periodontal ligament cells and human gingival fibroblasts (배양된 치주인대세포와 치은섬유아세포에서 상이하게 발현된 유전자들의 검토 양상)

  • Yoon, Hye-Jeong;Choi, Mi-Hye;Yeo, Shin-II;Park, Jin-Woo;Choi, Byung-Ju;Kim, Moon-Kyu;Kim, Jung-Chul;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.3
    • /
    • pp.613-625
    • /
    • 2006
  • Periodontal ligament(PDL) cells and human gingival fibroblasts(HGFs) play important roles in development, regeneration, normal function, and pathologic alteration. PDL cells and HGFs have the similarity related with general characteristics of fibroblast such as spindle shaped morphology, the presence of vimentin intermediate filament and the synthesis of interstitial collagens and fibronectin. There were many studies about the differences between PDL cells and HGFs, but they were not about whole gene level. In this study, we tried to explain the differences of gene expression profiles between PDL cells and HGFs, and the differences among three individuals by screening gene expression patterns of PDL cells and HGFs, using cDNA microarray. Although there were some variants among three experiments, a set of genes were consistentely and differentially expressed in one cell type. Among 3,063 genes, 49 genes were more highly expressed in PDL cells and 12 genes were more highly expressed in HGFs. The genes related with cell structure and motility were expressed more highly in PDL cells. These are cofilin 1, proteoglycan 1 secretory granule, collagen type I(${\alpha}$ 1), adducin gamma subunit, collagen type III(${\alpha}$ 1), fibronectin, lumican(keratan sulfate proteoglycan), and ${\alpha}$ -smooth muscle actin. Tissue inhibitor of metalloproteinase known as the enzyme controlling extracellular matrix with matrix metalloproteinase is more highly expressed in PDL cells, osteoprotegerin known as osteoclastogenesis inhibitory factor is more highly expressed in HGFs. We performed northern blot to verify cDNA microarray results on selected genes such as tissue inhibitor of metalloproteinase, fibronectin, osteoprogeterin. The result of northern blot analysis showed that each cell expressed the genes in similar pattern with cDNA microarray result. This result indicates that cDNA microarray is a reliable method in screening of gene expression profiles.

Immediate Connection of Customized Zirconia Abutment Using Flapless Guided Surgery: A Clinical Report (무절개 수술을 이용한 맞춤형 지르코니아 지대주의 즉시 장착 증례)

  • Lee, Gyeong-Je;Choi, Byung-Ho;Kim, Hee-Jun;Jung, Seng-Mi
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.2
    • /
    • pp.201-212
    • /
    • 2012
  • There are some similar aspects at histological and morphological characteristics between the peri-implant tissue and periodontal tissue and the direct attachment between the titanium and soft tissue around the implant called as "Functional ankylosis" can prevent the apical infiltration of inflammatory and bone resorption around implant. But, the repeated connection and disconnection of the abutment can destroy the mucosal barrier of soft tissue around the implant and can cause the marginal bone resorption. The amount of marginal bone resorption may reduced if the prosthetic abutment is placed at that time of surgery. Connection of the prosthetic abutment at surgery was limited because the low accuracy of conventional method, but by using of Cone Beam Computed Tomography(CBCT) and guide surgery, the 3-dimensional accuracy of implant placement became much higher than before and it became possible. This is a clinical case of immediate connection of prosthetic abutment and provisional restoration by using of precise CBCT diagnosis and pre-fabricated zirconia customized abutment at surgery and the alternative method is described in this article because of the clinically contentable results.

Maturation of cervical vertebrae in relation to menarche (초경 전후 경추골 성숙도에 관한 연구)

  • Lee, Jin-Hwa;Kang, Yoon-Goo;Lee, Ki-Soo;Nam, Jong-Hyun
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.28-35
    • /
    • 2009
  • Objective: The purpose of this study was to investigate the relationship between menarche and cervical vertebral maturation. Methods: Lateral cephalograms of 67 young korean girls within the range of 1 year before or after their menarche were gathered. The concavity of the cervical vertebrae base and the ratio of the base length to the 3rd and 4th cervical vertebrae anterior height were measured and analyzed. Results: The mean measured values were as follows, concavity of the 3rd cervical vertebrae base: 1.27(${\pm}0.18$) mm, concavity of the 4th cervical vertebrae base: 1.06(${\pm}0.15$) mm, ratio of the base length to the 3rd cervical vertebrae anterior height: 0.73(${\pm}0.06$) and ratio of the base length to the 4th cervical vertebrae anterior height: 0.70(${\pm}0.05$). There was a significant increase in the ratio of the base length to the 3rd vertebrae anterior height and the base concavity of the 3rd and 4th cervical vertebrae during the period of 1 year before to 1 year after their menarche. Conclusions: These characteristics of the 3rd and 4th cervical vertebrae on the lateral cephalogram can provide useful clues on evaluating the growth stage.

Histochemical Analysis of the Cutaneous Wound Healing in the Amphibian (양서류 피부 상처회복과정에 대한 조직화학적 분석)

  • Lim, Do-Sun;Jeong, Soon-Jeong;Jeong, Je-O;Park, Joo-Cheol;Kim, Heung-Joong;Moon, Myung-Jin;Jeong, Moon-Jin
    • Applied Microscopy
    • /
    • v.34 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • The wound healing is very complex biological processing including inflammatory, reepithelialization and matrix construction. According to the biological systematic category, the ability of the healing is very different. Generally healing ability of the lower animal group has been known more excellent compared to its higher group. Therefore, lower animals have been used as the experimental model to explore the mechanism of the wound healing or repair. To verify histochemical characteristics of the wound healing, we have used skin of the frog (Bombina orientalis) as known common amphibian. At day 1, 10, and 16, the mucous substance was very actively synthesized and strong positive by PAS and Alcian blue (pH 2.5). Day 10 after wounding, margin of the wound was gradually strong positive by PTAH staining for detection of collagen synthesis. At 3 to 6 hour and day 23 to 27, we have found the cell division was active through the MG-P staining, in which the concentration and division of DNA in nucleus was green to deep blue color.

Ultrastructure of the Submandibular Gland in the Big White-Toothed Shrew, Crocidura lasiura (우수리땃쥐 Crocidura lasiura 악하선의 미세구조)

  • Jeong, Soon-Jeong;Lim, Do-Seun;Park, Joo-Cheol;Kim, Heung-Joong;Jeong, Je-O;Choi, Baik-Dong;Yoon, Myung-Hee;Jeong, Moon-Jin
    • Applied Microscopy
    • /
    • v.35 no.2
    • /
    • pp.57-64
    • /
    • 2005
  • The ultrastructure and histochemical characteristics of the submandibular gland was examined in the big white-toothed shrew, Crocidura lasiura. A submandibular gland of Crocidura lasiura was a mixed gland composed of serous and mucous acinar cells. Secretory granules from the acini were discharged through the intercalated duct, the granular duct and the striated duct into the oral cavity. Serous and mucous acinar cells and granular duct cells had large amount of rough endoplasmic reticulum, free ribosome and prominent Golgi apparatus at the basal cytoplasm of the cell, and many granules at the apical cytoplasm. Oval type serous granules had a homogeneously pale round shape of bead at the center. Mucous granules were distinct from those of the other mammalian species having variety patterns with several dense bands into homogeneous pale matrix. A serous-like secretory granules and myelin-like body were observed in the cytoplasm and the lumen of granular duct cells. The myelin-like body is a characteristic structure only reported in the salivary glands of two shrews, Suncus murinus and C. dsinezumi. Striated duct cell had numerous well-developed mitochondria but secretory granule was not shown at all.

Surface Characteristics of Dental Casting Palladium Alloy for Replacement of Gold Alloy (금대체를 위한 치과주조용 파라듐 합금의 표면특성)

  • Park, Seon-Yeong;Hwang, In-Jo;Yu, Ji-Min;Park, Min-Gyu;Im, Sang-Gyu;Bae, Ho-Seong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.196-196
    • /
    • 2016
  • 치과나 기공소로부터 높은 원가로 인한 재료선택에 어려움을 겪고 있어 귀금속 금합금의 물성을 가질 수 있도록 하면서 가격급등으로 인한 문제 해결하기 위한 비귀금속 합금으로 대체가 필요하기에 이에 따른 연구가 이루어져 국산 제품의 상품화를 위해 파라듐을 이용하여 적합한 새로운 합금을 개발하는 것이 필요하다. 치과용 골드합금은 미국치과의사 협회의 구정에 의하면 1형부터 4형까지 분류하고 있으며 3형에 해당하는 강도와 기계적인 특성을 갖도록 파라듐으로 대체하는 연구가 진행중이거나 시판되고 있다. 따라서 본 연구에서는 2형, 3형 및 4형을 대체가능하도록 팔라듐을 기반으로 한 새로운 합금을 설계하고 합금의 성분원 소인 Au(1~5), Pd(20~25), Ag(70~75), In(1.5) 및 Zn(2)등으로 조성을 변화시켜 측량 후 합금을 제조하기 위하여 아르곤 분위기하의 진공아크용해로를 이용하여 용해하였다. 정량된 금속을 진공아크 용해로에 장입하고 용해는 균질한 합금이 되도록 최소한 6회 이상 용융을 실시하며 합금성분의 손실이 발행하지 않도록 보정을 하였다. 합금의 미세조직 관찰을 위하여 샘플을 고속 다이아몬드 정밀 절단기(Acculom-5, STRUERS, Denmark)를 이용하여 절단한 후 2000 grit의 Sic 연마지에서 단계적으로 $0.3{\mu}m$ 알루미나 분말까지 연마한 후 초음파 세척을 하였다. 준비한 시편은 KCN과 $(NH_4)_2S_2O_8$을 1:1로 혼합한 부식액으로 에칭한 후 OM과 SEM을 이용하여 조직을 관찰하였으며 각 샘플의 성분변화는 EDS 분석을 통해 확인하고 결정구조는 XRD를 사용하여 분석하였다. 경도시험은 비커스경도시험기를 이용하여 5kg의 하중을 30초간 작동시켜 압흔을 연결된 micron으로 평균값을 측정하였다. 각 시편의 부식거동은 POTENTIOSTAT(Model PARSTAT 2273, EG&G, USA)을 이용하여 구강 내환경화 유사한 $36.5{\pm}1^{\circ}C$의 0.9% NaCl에서 실시하였다. 인가전위는 -1500mV에서 1000mV까지 1.67 mV/min의 주사속도로 인가하여 시험을 수행하였으며 분극곡선으로부터 부식전위와 부식전류밀도 및 부동태영역의 전류밀도로 금속의 용출거동을 조사하였으며 부식이 끝난 시편은 FE-SEM과 EDS를 사용하여 조사하였다. 기계적인 특성은 Pd-Ag에 3wt%의 Au를 첨가한 합금이 Pd-Ag에 1.5wt%합금을 첨가한 경우에 비하여 기계적인 특성이 증가하고 내식성이 크게 증가하였다. 이들 합금에 Cu를 11wt%를 첨가한 경우는 비커스경도가 200이상으로 높게 나타났지만 내식성이 크게 감소하였다.

  • PDF

Insertion and removal torques according to orthodontic mini-screw design (교정용 미니스크류의 디자인에 따른 식립 및 제거 토오크)

  • Cha, Jung-Yul;Yoon, Tae-Min;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.5-12
    • /
    • 2008
  • Objective: This study was designed to analyze the primary and secondary stability characteristics of orthodontic mini-screws of tapered design when compared with the cylinder mini-screw. Methods: A total of 48 mini-screws were placed into the buccal alveolar bone of the mandible in 6 male beagle dogs. Comparison was made between tapered and cylinder type mini-screws (Biomaterials Korea, Seoul, Korea). Maximum insertion torque (MIT) was measured using a torque sensor (Mark-10, MGT 50, USA) during installation, and maximum removal torque (MRT) was recorded after 3 and 12 weeks of loading. Results: Taper mini-screws showed a higher MIT value of 22.3 Ncm compared with cylinder mini-screw showing 13.6 Ncm (p < 0.001). The MRT of the taper mini-screw showed a significantly higher value of 9.1 Ncm than those of cylinder mini-screw of 5.7 Ncm at 3-weeks after installation (p < 0.05). However, there was no difference in the MRT value between the taper and cylinder mini-screws at 12 weeks of loading. Conclusions: These results showed that the high insertion torque of the taper mini-screw design increases initial stability until 3 weeks of loading, but does not have any effect on the secondary stability at 12 weeks of loading.

Cervical design effect of dental implant on stress distribution in crestal cortical bone studied by finite element analysis (유한요소법을 이용한 임플란트 경부 디자인이 골응력에 미치는 영향 분석)

  • Kim, Kyung-Tak;Jo, Kwang-Heon;Lee, Cheong-Hee;Yu, Won-Jae;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.385-393
    • /
    • 2009
  • Statement of problem: High stress concentration on the crestal cortical bone has been regraded as a major etiologic factor jeopardizing long term stability of endosseous implants. Purpose: To investigate if the design characteristics of crestal module, i.e. internal type, external type, and submerged type, affect stress distribution on the crestal cortical bone. Material and methods: A cylindrical shaped implant, 4.3 mm in diameter and 10 mm in length, with 3 different crestal modules, i.e. internal type, external type, and submerged type, were analysed. An axisymmetric scheme was used for finite elment formulation. A vertical load of 50 N and an oblique load of 50N acting at $45^{\circ}$ with the implant's long axis was applied. The peak crestal bone stress acting at the intersection of implant and crestal bone was compared. Results: Under vertical load, the crestal bone stress was high in the order of internal, external, and submerged types. Under the oblique loading condition, it was in the order of internal, submerged, and external types. Conclusion: Crestal module design was found to affect the level of the crestal bone stresses although the actual amount was not significant.

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.