• Title/Summary/Keyword: Dental ceramics

Search Result 202, Processing Time 0.026 seconds

THE EFFECT OF SURFACE TREATMENT ON FRACTURE STRENGTH OF DENTAL CERAMICS (도재와 상아질의 표면 처리가 도재의 파절 강도에 미치는 영향)

  • Lee, Shin-Won;Lee, Sun-Hyung;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.5
    • /
    • pp.658-671
    • /
    • 1999
  • The major influencing factors on the strength of all-ceramic crowns are types of dental ceramics, fabrication techniques, methods of abutment preparation and cementation modes of all-ceramic restorations. Zinc phosphate cement and glass-ionomer cement were used as an early lot-ing media for all-ceramic crowns. Recently many studies have reported that resin cements have more advantages in increasing the fracture strength of restorations comparing with zincphosphate cement and glass-ionomer cement. The purpose of this study is to investigate the effect of etching, silane treatment, sandblasting and dentin bonding agents on fracture strengths of dental ceramics. 40 flat dentin specimens and 40 ceramic discs of 1.5mm thickness and 8mm diameter were fabricated, and divided into 4 groups according to surface treatments. Surface treatments before cementation were as follows Group I : (ceramic) : HF etching - silane treatment - application of bonding resin (dentin) : application of dentin bonding agent Group II : (ceramic) : sandblasting - application of bonding resin (dentin) : application of dentin bonding agent Group III : (ceramic) : application of bonding resin (dentin) : application of dentin bonding agent Group IV : (ceramic) : HF etching - silane treatment - application of bonding resin (dentin) : no dentin bonding procedure Dentin specimens and ceramic discs were cemented with dual cure resin cement, and went through thermocycling. Compressive stress es were loaded on the centers of ceramic discs with Instron test-ing machine, and fracture strengths resistance for catastrophic fracture were measured The results were as follows. 1. The group I showed the highest fracture resistance. The next was group II And group III, IV followed. 2. There was a significant difference in the mean value of fracture strengths between group I and group III (p<0.05), but no significant differences between group I and group II, and group II and group III (p>0.05). 3. There was a significant difference in the mean value of fracture strengths between group I and group IV (p<0.05).

  • PDF

Bending strength of alumina coated with bioglass and soda lime glass and the precipitation on the surface of coated alumina in PBS (생체 유리와 소다 유리침투에 따른 알루미나 세라믹의 굴곡 강도 및 PBS에서의 표면 생성물 연구)

  • Yuu, Jae-Yang
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.39-45
    • /
    • 2008
  • Titanium and its alloys are widely used as dental implants materials because of their excellent mechanical properties. However, the alumina and zirconia ceramics are preferred to use as the substitute of Ti implants because there is a problems in esthetics and biocompatibility in Ti implant. The the glass infiltrated alumina ceramics are studied to increase the toughness and biocompatibility. The 45S5 and soda-lime glass powder was mixed with ethanol at ratio of 1:1 and brushed on the surface of alumina. Then it was heat treated in the electric furnace at $1400^{\circ}C$ from 30 min. to 5 hours. The glass powder was controlled from 200 to $350{\mu}m$ using ball milling. After heat treatment, the glass infiltrated specimen was tested in universal testing machine to measure the bending strength. The surface microstructure of each specimen was observed with SEM. The biocompatibility of 45S5 and soda-lime glass coated alumina was investigated using PBS at $36.5^{\circ}C$ incubator. The specimen was immersed in PBS for 3, 5, 7, 10 days. After that, the surface morphology was investigated with SEM. As the results of experiment, the 45S5 bioglass infiltrated alumina show the increase of bending strength according to the increasing of heat treatment time from 30 min. to 5 hours at $1400^{\circ}C$ Finally the 1370N bending strength of alumina increased to 1958N at 5 hours heat treatment, which shows 1.4 times higher. In contrast to this, the soda lime glass infiltrated alumina ceramics shows the convex curve according to heat treatment time. Thus it shows maximum bending strength of 1820N at 1 hour heat treatment of $1400^{\circ}C$ It gives 1.3 times higher. However, the bending strength of soda lime glass infiltrated alumina is decreasing with increasing heat treatment time after 1 hour. The precipitation on the surface of 45S5 glass infiltrated alumina was revealed as a sodium phosphate ($Na_{6}P_{6}O_{24}6H_{2}O$) and the amount of precipitation is increasing with increasing of immersion time in PBS. In contrast to this, there is no precipitation are observed on the surface of soda lime glass infiltrated alumina. This implies that 45S5 glass infiltrated alumina brings more biocompatible when it is implanted in human body.

  • PDF

Comparative Study of Properties of Dental Zirconia According to Microwave Sintering Method (마이크로웨이브 소결방법에 따른 치과용 지르코니아의 물리적 특성)

  • Kim, Tae-Suk;Yu, Chin-Ho;Kim, Gi-Chul;Park, Won-Uk;Seo, Jung-Il;Hwang, Kyu-Hong
    • Journal of Technologic Dentistry
    • /
    • v.34 no.1
    • /
    • pp.11-21
    • /
    • 2012
  • Purpose: Densification and mechanical properties of dental zirconia ceramics were evaluated by different sintering methods. Materials and Methods: Y-TZP zirconia block(Kavo $Everest^{(R)}$ ZS blank, Kavo dental GmbH, Bismarckring, Germany) was used in this study. Sintering were performed in heat sintering furnace and microwave sintering furnace, and then experimented and analyzed on a change in densification according to the sintering time, a change in densification according to thickness, flexural strength and micro-structure in zirconia specimens. Results: Microwave sintering was very effective in considerable mechanical properties such as flexural strength and bulk density was drastically increased than conventional electric heating method. It is also shown that microwave sintering time was faster and more economical than common method to be present in qualities which equal or exceed. Conclusion: It will be important to seek the accurate sintering condition of dental zirconia by microwave sintering method and the continuous research is necessary for the study of relationship between sintering methods and mechanical properties.

Osseointegration of Ceramics & Zirconia : A Review of Literature (세라믹과 지르코니아의 골유착에 관한 고찰)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.319-326
    • /
    • 2012
  • For many years, ceramics have been used in fixed prosthodontics for achieving optimal esthetics. but, they have another use as well. Many studies today show ceramics can be used for biomaterials. In the beginning researchers made a start in the study of aluminium oxide and sapphire for biomaterial. The appearance of Zirconia began a new phase of research. Zirconia was introduced into implantology as an alternative to titanium, because of its white color, good mechanical properties and superior biocompatibility. But it is not easy to surface treatment in comparison with titanium. To overcome the limitation, interconnected porous bodies of zirconia were fabricated by sintering technique. And the technique of coating was developed. Therefore, some zirconia implants are currently available. It is thought that Research of biomaterials as a variety of puposes for the use of zirconia is looking very promising. The purpose of this paper reviews are to evaluation of zirconia as biomaterials.

Reconstruction of upper anterior by implant using customized zirconia abutment and all ceramics: a clinical report (맞춤형 지르코니아 지대주와 완전도재관을 이용한 상악 전치부 임플란트 보철 수복)

  • Kim, Ja-Yeong;Seo, Jae-Min
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.81-92
    • /
    • 2014
  • It is so hard to obtain optimal anterior esthetics in the implant prosthesis. This is not only because of hard and soft tissue problem such as alveolar bone resorption and interdental papilla loss but also because of prosthetic limitation related to marginal exposure of metal abutment and metal ceramics and low transillumination. In this case, guided soft tissue healing is obtained using a long term provisional restoration with soft and hard tissue augmentation or immediate implantation. Then, this healed tissue is transferred to final master model using a customized impression coping and the implant is restored with a customized zirconia abutment and a all ceramics. This case presents satisfying result esthetically and functionally.

Influences of luting cement shade on the color of various translucent monolithic zirconia and lithium disilicate ceramics for veneer restorations

  • Ghada Alrabeah;Nawaf Alamro;Atif Alghamdi;Ahmed Almslam;Meshari Azaaqi
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.5
    • /
    • pp.238-247
    • /
    • 2023
  • PURPOSE. The purpose of this study was to assess the effect of resin cement shade on the color of different novel ultratranslucent monolithic zirconia and lithium disilicate veneer materials. MATERIALS AND METHODS. For a total of 40 specimens, flat cylindrical discs with a 9-mm diameter and 0.5-mm thickness were created using CAD/CAM technology. The specimens were divided into five groups according to their material (n = 8) (e.max, Prettau, Aidite, Shofu and Dima) using A1 shade. Resin discs with the same diameter and shade as the specimens served as tooth-colored substructures. Three shades (neutral, light and warm) of resin cement try-in pastes (Variolink Esthetic LC) were used as the luting cement material. The color of each material group was measured before and after cementation using the three cement shades, and the CIE L*a*b* coordinates were obtained with a spectrophotometer. Values for the translucency parameter (TP) and color change delta E (E) before (baseline) and after cementation of each specimen were determined. To compare differences among the material groups within each shade of cement and among various shades of cement within each material, the data were analyzed using one-way ANOVA and post hoc testing. RESULTS. Color coordinates L*, a* and b* significantly changed after the application of try-in pastes relative to baseline values, with a noticeable decrease in lightness (L*) (P < .05). A significant color change (ΔE) was observed in all tested materials after cementation, with ΔE values exceeding 3.3 (P < .05). Although TP changed after cementation for most materials tested, these changes were not statistically significant (P > .05). Shofu and Dima ceramics showed the lowest TP values, while Aidite and Prettau showed the highest TP values. For e.max, translucency decreased after cementation with neutral and warm shades, and it significantly increased after cementation with a light shade. CONCLUSION. The shade of cement significantly altered the final color of the ceramic veneer material to a level above the threshold at which the clinical perception of color change occurred (> 3.3). The TP was not influenced by the cement shade. The translucency levels of the novel ultratranslucent multilayer monolithic zirconia ceramics Aidite and Prettau were higher than that of the lithium disilicate e.max material.

Shear bond strength in bilayer metal-heat pressed glass ceramic structure (열가압 방식의 금속-유리도재 이중 구조물의 전단결합강도에 대한 연구)

  • Lee, Kyungeun;Park, Jin-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.39 no.2
    • /
    • pp.101-107
    • /
    • 2017
  • Purpose: The purpose of this study was to compare the shear bond strength of the metal-heat pressed glass ceramic bilayer structure. Methods: Metal framework specimens were prepared and surface is spreaded opaque(IPS InLine system opaque, IvoclarVivadent, Liechtenstein). There were 10 specimens for each bilayer dental ceramic group. The first group was porcelain fused metal, Press on metal IPS Inline press group, and press on metal HASS prototype group. Specimens measured for the shear bond strength on Schwickerath test by Instron universal testing machine(Instron3345, Instron Corp., USA). Mean average bond strength values of each specimen group were analyzed using a one-way ANOVA analysis of variance Saphiro-wilk's test. Statistical analysis were performed using IBM SPSS 23.0(IBM Co., Armonk, USA) Results: $RMS{\pm}SD$ The highest mean average HASS POM showed a bond strength value ($47.55{\pm}12.80Mpa$). The lowest mean average values Porcelain fused metal ($33.30{\pm}2.00Mpa$). Independent t-test was conduct to analysis the significant difference (p<0.05) (Table 3). Conclusion: Three kinds of Metal/ glass bilayer dental ceramics bond strength were clinical acceptability. Especially, as lithium disilicate containing represents higher bond strength.

The effects of the number of times dipped in coloring liquid and final sintering temperature on flexural strength of zirconia ceramics: Zirconia ceramics having improved transparency (착색액 침지 횟수와 최종 소결 온도가 지르코니아 세라믹의 굴곡강도에 미치는 영향)

  • Kong, Moon-Chun;Kim, Kap-Jin;Kown, Tae-Yub;Hong, Min-Ho
    • Korean Journal of Dental Materials
    • /
    • v.44 no.2
    • /
    • pp.171-178
    • /
    • 2017
  • The purpose of this study is to investigate the effect of number of times dipped in coloring liquid and sintering temperature on the flexural strength of zirconia ceramic. In this study, using a zirconia block having improved transparency, specimens with size of $25mm{\times}2mm{\times}1.5mm$ were fabricated. The zirconia ceramic specimens were divided into three groups according to the number of times dipped in coloring liquid by 0, 2 and 4 times, and dyed in the coloring liquid to give color to each specimen. Then, after sintering them at the final temperature of $1,450^{\circ}C$ and $1,600^{\circ}C$, flexural strength was measured using a universal testing machine (total 6 group, n=10 for each group). Also, a scanning electron microscopy (SEM) was performed to observe its microstructure, and the data obtained through the experiment were analyzed with two-way ANOVA. The results of the flexural strength analysis show that the highest value was measured $762.3{\pm}42.3MPa$ in EKL2 group, while the lowest value was $516.4{\pm}77.1MPa$ in EKH4 group. According to the results of the two-way ANOVAs, flexural strength was not related with interaction between sintering temperature and number of times dipped in coloring liquid ($R^2=0.737$). However, there were statistically significant differences in flexural strength depending on sintering temperature (P<0.001). The flexural strength of zirconia ceramics having improved transparency was dependent on sintering temperature. The number of times dipped in the coloring liquid did not affect flexural strength of the zirconia ceramic having improved transparency.

Review of a Laminate Veneer Technique using a Castable Apatite Ceramic Material (Castable Apatite Ceramics Laminate Veneers 술식에 대한 고찰)

  • Yang, Jae-Ho
    • The Journal of the Korean dental association
    • /
    • v.25 no.11 s.222
    • /
    • pp.1019-1028
    • /
    • 1987
  • 결손된 치질과 변색된 법랑질을 수복하기 위해 많은 재료와 술식이 개발되어왔다. 즉 silicate cement, PMMA resin, BISGMA composite resin, glass ionomer cement, porcelain등이 이용되어 왔으나 이것들은 biocompatible하지 않아 이상적인 재료는 아니다. 따라서 인간의 결손된 enamel을 수복할 수 있는 새로운 생역학적인 재료가 필요하게 되었다. 필자는 최근 관심의 대상이 되고 있는 porcelain laminate veneer system(층상 도재 전장관)에 관하여 문헌을 중심으로 고찰해 보고자 한다(국내에서는 장완식 교수께서 1987년 6월10일 보철학교실 세미나에서 video tape를 통해 소개한바 있음). 여기서는 Hobo, Iwata(1985)등이 소개한 castable apatite ceramic material을 이용한 laminate veneer술식에 관해 기술하고 내화성 모형(refractory cast)을 이용한 laminate술식과 비교 기술하고자 한다.

  • PDF

인공치아용 결정화 유리의 제조(I)

  • 한복섭;이준희
    • Journal of Biomedical Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.295-304
    • /
    • 1990
  • In order to use for artificial dental tooth (dental crowens) , new glass-ceramics material has been studied. Its basic composition and the condition of heat treatment for crystalization, mechanical and chemical properties were investigated. Adding of the LAS system composition in the basic glass, time and temperature for crystalization were shortened. Fracture toughness (kic)of samples heat treated at 90$0^{\circ}C$ for 2 hours is 2.5-2.6MN/m3/2, the optimum condition of heat treatment for artificial tooth is A and B samples heating to 75$0^{\circ}C$ for 2 hours, raising to 90$0^{\circ}C$ and maintaining at 90$0^{\circ}C$ for 2 hours and C sample heating to 75$0^{\circ}C$ maintaining at 75$0^{\circ}C$ for 2 hours. In acid and'alkali solution, chemical durability is excellent.

  • PDF