• 제목/요약/키워드: Dental cast analysis

검색결과 80건 처리시간 0.034초

부산, 경남지역 치과기공사의 직무분석 (The job analysis of dental technicians in Busan, Gyeongnam)

  • 나정숙
    • 대한치과기공학회지
    • /
    • 제36권4호
    • /
    • pp.277-296
    • /
    • 2014
  • Purpose: This study intends to set standard for organizing the curriculum of short-term dental technicians and the change of job environment, as well as the knowledge & training, by identifying the importance and actual job performance of dental technicians following job analysis in the university education of Dept. of Dental Laboratory Technology, and furthermore to foster junior executives to cope with modernization and globalization. Methods: The tools used in this study are based on the job analysis of research report suggested by National Health Personnel Licensing Examination Board(Lee Gyu-seon, 2011), and it consists of general characteristic 7 items. Every competence duty was measured through Likert 5 point gauging, and internal consistency through Cronbach's Alpha. The competence importance of entire questionnaire was .984 and its performance was .874, reflecting considerably high level, and in terms of each competence duty, high credibility was proved and high internal consistency was verified with competence importance ranging from the minimum .655 to the maximum .966 and its performance ranging from the minimum .677 to the maximum .993. Results: Competence importance and its performance in each duty on the job analysis of dental technicians were measured. In competence importance in each duty, the highest was "checking design order form"(average, 4.52), followed by "selling dental prosthesis"(average 4.49), "making removable orthodontic appliance"(average, 4.48), "open managing dental laboratory"(average, 4.46) in order. However, "making complete denture" was found the lowest(average, 4.23), with importance of all competence dutys was considerably high level. In the performance of its competence duty, "checking design order form"(average, 4.04) was found to be the most importance competence, followed by "making conservative restoration"(average, 4.00), "making porcelain"(average 3.98), "checking working cast"(average, 3.90) in order. However it was found out that "making fixed orthodontic appliance"(average, 3.12) was the lowest, and the importance of all competence dutys was quite high level. Conclusion: The duties of dental technicians consist of 13 kinds, in total, and it was found out that "checking design order form"(average, 4.52) was the most important in the competence importance and job performance. In particular, it was revealed that there was a great difference between the competence importance and its performance in the order of "selling dental prosthesis", "open managing dental laboratory", "making removable orthodontic appliance", "making CAD/CAM prosthesis", and then "making fixed orthodontic appliance".

Fracture resistances of zirconia, cast Ni-Cr, and fiber-glass composite posts under all-ceramic crowns in endodontically treated premolars

  • Habibzadeh, Sareh;Rajati, Hamid Reza;Hajmiragha, Habib;Esmailzadeh, Shima;Kharazifard, Mohamadjavad
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.170-175
    • /
    • 2017
  • PURPOSE. The aim of the present study was to evaluate the fracture resistances of zirconia, cast nickel-chromium alloy (Ni-Cr), and fiber-composite post systems under all-ceramic crowns in endodontically treated mandibular first premolars. MATERIALS AND METHODS. A total of 36 extracted human mandibular premolars were selected, subjected to standard endodontic treatment, and divided into three groups (n=12) as follows: cast Ni-Cr post-and-core, one-piece custom-milled zirconia post-and-core, and prefabricated fiber-glass post with composite resin core. Each specimen had an all-ceramic crown with zirconia coping and was then loaded to failure using a universal testing machine at a cross-head speed of 0.5 mm/min, at an angle of 45 degrees to the long axis of the roots. Fracture resistance and modes of failure were analyzed. The significance of the results was assessed using analysis of variance (ANOVA) and Tukey honest significance difference (HSD) tests (${\alpha}=.05$). RESULTS. Fiber-glass posts with composite cores showed the highest fracture resistance values ($915.70{\pm}323N$), and the zirconia post system showed the lowest resistance ($435.34{\pm}220N$). The corresponding mean value for the Ni-Cr casting post and cores was reported as $780.59{\pm}270N$. The differences among the groups were statistically significant (P<.05) for the zirconia group, as tested by ANOVA and Tukey HSD tests. CONCLUSION. The fracture resistance of zirconia post-and-core systems was found to be significantly lower than those of fiber-glass and cast Ni-Cr post systems. Moreover, catastrophic and non-restorable fractures were more prevalent in teeth restored by zirconia posts.

Acute Malocclusion Related to Posterior Disc Displacement According to Complete Disc Tearing: Two Case Reports

  • Jo-Eun Park
    • Journal of Oral Medicine and Pain
    • /
    • 제49권2호
    • /
    • pp.29-34
    • /
    • 2024
  • Acute malocclusion can occur in conditions related to temporomandibular joint (TMJ) disorders. This report presents two cases of acute malocclusion related to posterior disc displacement according to complete disc tearing. A 65-year-old male and an 88-yearold female presented with TMJ pain and occlusal discrepancies. Clinical examination, computed tomography, and magnetic resonance imaging revealed complete disc tearing and posterior displacement of a partial disc fragment. Dental cast analysis revealed a slight anterior and lateral deviation of the mandible toward the non-affected side; however, clinically, significant occlusal changes were not observed. This was attributed to the displacement of a small disc fragment rather than the entire disc. Including the cases presented, most instances of complete disc tearing responded well to conservative treatment such as pharmacotherapy and physical therapy, resulting in pain alleviation, and residual occlusal changes were tolerable for the patients in their daily activities. However, persistent occlusal changes or severe chewing difficulty may require surgical intervention.

Accuracy of Bolton analysis measured in laser scanned digital models compared with plaster models (gold standard) and cone-beam computer tomography images

  • Kim, Jooseong;Lagravere, Manuel O.
    • 대한치과교정학회지
    • /
    • 제46권1호
    • /
    • pp.13-19
    • /
    • 2016
  • Objective: The aim of this study was to compare the accuracy of Bolton analysis obtained from digital models scanned with the Ortho Insight three-dimensional (3D) laser scanner system to those obtained from cone-beam computed tomography (CBCT) images and traditional plaster models. Methods: CBCT scans and plaster models were obtained from 50 patients. Plaster models were scanned using the Ortho Insight 3D laser scanner; Bolton ratios were calculated with its software. CBCT scans were imported and analyzed using AVIZO software. Plaster models were measured with a digital caliper. Data were analyzed with descriptive statistics and the intraclass correlation coefficient (ICC). Results: Anterior and overall Bolton ratios obtained by the three different modalities exhibited excellent agreement (> 0.970). The mean differences between the scanned digital models and physical models and between the CBCT images and scanned digital models for overall Bolton ratios were $0.41{\pm}0.305%$ and $0.45{\pm}0.456%$, respectively; for anterior Bolton ratios, $0.59{\pm}0.520%$ and $1.01{\pm}0.780%$, respectively. ICC results showed that intraexaminer error reliability was generally excellent (> 0.858 for all three diagnostic modalities), with < 1.45% discrepancy in the Bolton analysis. Conclusions: Laser scanned digital models are highly accurate compared to physical models and CBCT scans for assessing the spatial relationships of dental arches for orthodontic diagnosis.

레이저 용접과 납착법으로 연결된 귀금속성 금속-도재 합금의 물리적 성질 (Mechanical Properties of Precious Metal-Ceramic Alloy Joined by the Laser-Welding and the Soldering Method)

  • 오정란;이석형;우이형
    • 구강회복응용과학지
    • /
    • 제19권4호
    • /
    • pp.269-279
    • /
    • 2003
  • This study investigated the mechanical properties of precious metal-ceramic alloy joined by the laser-welding and the soldering compared with the parent metal. Twenty-four tensile specimens were cast in precious metal-ceramic alloy and divided into three groups of eight. All specimens in the control group(group 1) were left in the as-cast condition. Group 2 and 3 were the test specimens, which were sectioned at the center. Eight of sectioned specimens were joined by soldering with a propane-oxygen torch, and the remaining specimens were joined by laser-welding. After joining, each joint diameter was measured, and then tested to tensile failure on an Instron machine. Failure loads were recorded, and then fracture stress(ultimate tensile strength), 0.2% yield strength and % elongation calculated. These data for three groups were subjected to a one-way analysis of variance(ANOVA). Neuman-Keuls post hoc test was then used to determine any significant differences between groups. The fracture locations, fracture surfaces were examined by SEM(scanning electron microscope). The results were as follows: 1) The tensile strength and 0.2% yield strength of the soldered group($280.28{\pm}49.35MPa$, $160.24{\pm}26.67MPa$) were significantly less than both the as-cast group($410.99{\pm}13.07MPa$, $217.82{\pm}17.99MPa$) and the laser-welded group($383.56{\pm}59.08MPa$, $217.18{\pm}12.96MPa$). 2) The tensile strength and 0.2% yield strength of the laser-welded group were about each 98%, 99.7% of the as-cast group. There were no statistically significant differences in these two groups(p<0.05). 3) The percentage elongations of the soldered group($3.94{\pm}2.32%$) and the laser-welded group($5.06{\pm}1.08%$) were significantly less than the as-cast group($14.25{\pm}4.05%$) (p<0.05). 4) The fracture of the soldered specimens occurred in the solder material and many porosities were showed at the fracture site. 5) The fracture of the laser-welded specimens occurred also in the welding area, and lack of fusion and a large void was observed at the center of the fracture surface. However, the laser-welded specimens showed a ductile failure mode like the as- cast specimens. The results of this study indicated that the tensile strengths of the laser-welded joints were comparable to those of the as-cast joints and superior to those of the soldered joints.

치과용 캐드캠을 이용하여 연질금속 재료로 제작한 고정성 보철물의 변연 간격 평가 (Evaluation of Marginal Gap of Fixed Dental Prostheses Fabricated by Soft Metal Material Using Dental CAD/CAM)

  • 김재홍;김원수;김기백
    • 치위생과학회지
    • /
    • 제14권3호
    • /
    • pp.349-355
    • /
    • 2014
  • 본 연구는 최근 치의학계 전반적으로 치과용 캐드캠 시스템의 사용이 증가함에 따라 새로운 재료의 개발도 활발히 이루어지고 있는 현실을 반영하였다. 최근 새롭게 개발된 고정성 보철물의 제작 재료인 연질금속재료를 이용하여 제작된 고정성 보철물의 변연 간격을 평가하여 봄으로써 신재료의 임상적 허용 가능성을 변연 간격을 기준으로 가늠하여보고자 하였으며, 나아가서는 치과의사, 치과위생사 및 치과기공사 등 해당 분야 임상가들에게 참고자료를 제시하고자 하였다. 연구 결과에 따르면 연질금속블록을 가공하여 제작된 집단이 전통적인 방식에 의해 제작된 집단보다 우수한 변연간격을 보였으나, 통계적으로 유의하지 않았다. 또한 연질금속블록을 가공하여 제작된 보철물들의 변연 간격이 임상적 허용 수치로 제시되고 있는 $120{\mu}m$를 넘지 않는 것으로 보아 변연 간격을 기준으로 하였을 때 임상적으로 허용이 가능할 것으로 생각된다.

Computerized occlusal analysis: correlation with occlusal indexes to assess the outcome of orthodontic treatment or the severity of malocculusion

  • Lee, Sang-Min;Lee, Jin-Woo
    • 대한치과교정학회지
    • /
    • 제46권1호
    • /
    • pp.27-35
    • /
    • 2016
  • Objective: The aims of our study were to verify the validity of the T-Scan III system (Tekscan) as an objective occlusal evaluation tool, and to assess the differences between two occlusal indexes - the peer assessment rating (PAR) index and the American Board of Orthodontics objective grading system (OGS) - by comparing the scores derived from the T-Scan III system with the two occlusal indexes and analyzing the correlations between them. Methods: The final study sample included 48 adult volunteers (39 men and 9 women, mean age $24.14{\pm}3.16years$), after excluding 29 volunteers whose occlusion could not be evaluated by the T-Scan III system due to severe skeletal or occlusal problems. PAR index and OGS scores were assessed using dental study models, and measurements of centric occlusion, protrusive movement, and lateral excursion movement were obtained via the T-Scan III system. The results were analyzed to determine correlations. Results: Occlusal analysis by the T-Scan III system was clinically reliable (p < 0.05), and the PAR index and OGS scores were significantly correlated with several measurements obtained with the T-Scan III system (p < 0.05). Conclusions: The T-Scan III system is a quantitative and reliable method for occlusal evaluation, and represents a potential substitute for occlusal indexes. Compared to the PAR index, the OGS scores of more variables were significantly correlated with the T-Scan measurements.

A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: effects of tooth irregularity and scanning direction

  • Anh, Ji-won;Park, Ji-Man;Chun, Youn-Sic;Kim, Miae;Kim, Minji
    • 대한치과교정학회지
    • /
    • 제46권1호
    • /
    • pp.3-12
    • /
    • 2016
  • Objective: The purpose of this study was to compare the precision of three-dimensional (3D) images acquired using iTero$^{(R)}$(Align Technology Inc., San Jose, CA, USA) and Trios$^{(R)}$(3Shape Dental Systems, Copenhagen, Denmark) digital intraoral scanners, and to evaluate the effects of the severity of tooth irregularities and scanning sequence on precision. Methods: Dental arch models were fabricated with differing degrees of tooth irregularity and divided into 2 groups based on scanning sequence. To assess their precision, images were superimposed and an optimized superimposition algorithm was employed to measure any 3D deviation. The t-test, paired t-test, and one-way ANOVA were performed (p < 0.05) for statistical analysis. Results: The iTero$^{(R)}$ and Trios$^{(R)}$ systems showed no statistically significant difference in precision among models with differing degrees of tooth irregularity. However, there were statistically significant differences in the precision of the 2 scanners when the starting points of scanning were different. The iTero$^{(R)}$ scanner (mean deviation, $29.84{\pm}12.08{\mu}m$) proved to be less precise than the Trios$^{(R)}$ scanner ($22.17{\pm}4.47{\mu}m$). Conclusions: The precision of 3D images differed according to the degree of tooth irregularity, scanning sequence, and scanner type. However, from a clinical standpoint, both scanners were highly accurate regardless of the degree of tooth irregularity.

세 가지 방식으로 제작된 레진코핑의 내면적합성 평가: 3차원적 분석 (Assessment of internal fitness on resin copings fabricated by 3 - ways methods: Three - dimensional analysis)

  • 강신영;박진영;김동연;김웅철
    • 대한치과기공학회지
    • /
    • 제39권1호
    • /
    • pp.17-24
    • /
    • 2017
  • Purpose: The purpose of this study was to evaluate the internal fitness of the resin coping that was fabricated by the traditional and Digital manufacturing methods through 3-dimensional analysis. Methods: maxillary right second molar was chosen implant master model. Custom-built impression trays were manufactured. After screwing the pick-up impression coping onto the master cast, impressions were made with silicone impression. The Working model was then made with type IV stone. The coping was fabricated: SLAC group (n=8), APPC group (n=8), LAPC group (n=8) Resin coping data was measured by using a three-dimensional evaluation program. Internal fitness was calculated by RMS (Root Mean Square).It measures mean and Standard Deviation (SD). Results: Three groups are measured $47.11{\pm}(3.08){\mu}m$ total RMS of SLAC group, $48.35({\pm}1.55{\mu}m)$ for total RMS of LAPC group, $43.45{\pm}2.09{\mu}m$ for total RMS of APPC group. Measured value is gradually increased. Followed by autopolymerized pattern resin; Stereolithography resin, Light-activated pattern resin But there were no differences stastically(P>0.321). Conclusion: Evaluation of internal fitness on Resin copings was fabricated by three-ways methods showed that no differences statistically significant and clinically acceptable results.

Comparative analysis of the clinical techniques used in evaluation of marginal accuracy of cast restoration using stereomicroscopy as gold standard

  • Rastogi, Abhishek;Kamble, Vikas
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.69-75
    • /
    • 2011
  • This study assessed the effect of preparation design on marginal adaptation and also compared the sensitivity and specificity of clinical evaluation techniques for marginal accuracy of cast restorations to stereomicroscopy. MATERIALS AND METHODS. Three Ivorine molar teeth of different designs were prepared. (A)-A complete crown preparation with buccal shoulder and beveled finish line. (B)-A complete crown preparation with chamfer finish line. (C)-A three-quarter crown preparation with proximal boxes and beveled finish line. Twenty four castings were prepared with eight castings for each design respectively. Each casting underwent examination with an explorer, disclosing media, and a stereomicroscope. Stereomicroscopy at a value less than or equal to 30 microns was used as a gold standard to evaluate the significance of different designs on marginal adaptation. Chi-square tests of independence and Kruskal-Wallis were used to evaluate the effect of preparation design and compare the agreement between examination methods for detection of marginal gap size of greater than or equal to 30 microns (${\alpha}$=.05). Sensitivity and specificity for explorer and disclosing media as compared to stereomicroscope was calculated using statistical formula given by Park. RESULTS. The preparation design did not significantly affect overall marginal adaptation. Examination by explorer and disclosing media at $30 \;{mu}m$ revealed 39% and 10.06% sensitivity and 91% and 82% specificity respectively. CONCLUSION. Preparation designs examined in this study did not significantly affect the marginal adaptation of the castings. Commonly used clinical evaluation techniques using explorer and disclosing media appeared to be inadequate for assessment of marginal accuracy.