• Title/Summary/Keyword: Dental amalgam

Search Result 143, Processing Time 0.025 seconds

AN ELECTROCHEMICAL STUDY ON THE OXIDATION' AND REDUCTION OF DENTAL AMALGAM (치과용 아말감의 산화환원에 관한 전기화학적 연구)

  • Yi, In-Bog;Lee, Myong-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.431-445
    • /
    • 1993
  • The purpose of this study was to observe corrosion characteristics of six dental amalgams and was to analyse corrosion products electrochemically. After each amalgam alloy and Hg was triturated as the direction of the manufacturer by using mechanical amalgamator, the triturated mass was inserted into the cylinderical metal mold ($12{\times}10mm$) and was condensed with 160kg/$cm^2$ by using the hydrolic press. The specimen was removed from the mold and was stored at room temperature for 1 week, and was polished with amalgam polishing kit. The anodic and cathodic polarization curve was obtained by using cyclic voltammetric method with 3-electrode potentiostat in saline for each amalgam and Ag, Sn, Cu plate specimen at $37{\pm}0.5^{\circ}C$. The potential sweep range was -1.7V~0. 4V(vs SCE) in working electrode and scan rate was 50mV/s and the exposed surface area of each specimen to the electrolytic solution was $0.79cm^2$. The results were as follows. 1. In anodic-cathodic polarization curve of amalgam specimens, two anodic current rising areas and two cathodic current peaks were obtained at the low Cu amalgam(CF, CS) specimen and three anodic current rising areas and three cathodic current peaks were obtained at the high Cu amalgam (TY, DS, HV) specimen. 2. As this compared with the anodic and cathodic current peak potentials of Sn, Cu and Ag specimen, the first cathodic current peak I c was caused by the reduction of divalent tin salt, second cathodic current peak IIIc results from the reduction of quadravalent tin salt, and third cathodic current peak me results from the reduction of copper salt. 3. As reverse potential sweeping was done repeatedly, anodic current was decreased slightly in all amalgam specimens.

  • PDF

Association between Amalgam Tooth Fillings and Blood Mercury Levels in Children

  • SaKong, Joon;Choi, Youn-Hee;Chung, Sun-Young;Kwon, Ho-Jang;Karmaus, Wilfried;Merchant, Anwar T.;Ha, Mi-Na;Hong, Yun-Chul;Kang, Dong-Mug;Song, Keun-Bae
    • International Journal of Oral Biology
    • /
    • v.36 no.3
    • /
    • pp.123-128
    • /
    • 2011
  • The notion that dental amalgam is a potential source of mercury exposure remains a controversial issue. However, there are few epidemiological analyses that have addressed whether this occurs in children. We aimed in our current study to identify the relationship between dental amalgam filling surfaces and the blood mercury levels in a cohort of 711 South Korean children aged between 8-9 years. Oral examinations were conducted to detect the number of amalgam filling surfaces on the teeth of these individuals. Blood samples were also taken from these children to assess the levels of mercury accumulation in the body. The amalgam filling surfaces were classified into four groups based on their number: 0 (n = 368), 1-5 (n = 219), 6-10 (n = 89), and 11+ (n = 35). The blood mercury levels in the children with more than 10 amalgam surfaces was 0.47 ${\mu}g$/L higher on average than those with no amalgam surfaces after adjusting for the frequency of fish or seafood consumption, age, and gender (P < 0.05). We found from our data that a higher number of dental amalgam fillings correlated with a higher blood mercury level in Korean children. Further studies are needed to investigate whether these elevated mercury levels exert neurotoxic or nephrotoxic effects.

Association between amalgam removal and urinary mercury concentration: a pilot study (아말감 충전물 제거와 뇨중 수은농도의 관련성 평가: 예비연구)

  • Baek, Hye-Jin;Sa, Kong-Joon;An, Seo-Young;Lee, Hee-Kyung;Song, Keun-Bae;Choi, Youn-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.431-438
    • /
    • 2012
  • Objectives : The aim of this study was assessment of the variation of urinary mercury concentrations after removal of amalgam fillings in children. Methods : 10 elemental school children with amalgam filling tooth surfaces were took part in this study. One dentist recorded the number of amalgam filling surface, and general characteristics of subjects were surveyed by questionnaire. Each urine samples were collected before, immediately after and after 24 hours amalgam removal. The statistical analysis was performed using the SPSS 18.0. Results : The mean concentration urinary mercury immediately after amalgam removal was higher ($5.70{\pm}1.20{\mu}g/g$ creatinine) than before amalgam removal ($5.28{\pm}1.53{\mu}g/g$ creatinine). The mean concentration urinary mercury level whose have 1-10 amalgam removal surfaces was increased after amalgam removal compared with before. Conclusions : Mercury concentration in urine was influenced by amalgam removal.

분산형 Amalgam에 대한 임상적 연구

  • Sunoo, Young-Gook
    • The Journal of the Korean dental association
    • /
    • v.18 no.2 s.131
    • /
    • pp.115-119
    • /
    • 1980
  • The purpose of this study was to observe clinical behavior on a national dispersant amalgam alloy, KISTCAP which newly developed by the KIST (Korea Instute for Science and Technology) in Korea. The results were as follows: 1. There was no significant difference in manipulating between the above mentioned alloy and the conventional lathe cut alloy. 2. The condensation pressure for this alloy was relatively less than that of conventional one. 3. More time was needed to polish the surface of this amalgam filling body than the conventional one. 4. No notable difference was seen in the over-all clinical behavior between the Whitecap and kistcap, except the latter one showed a little more tendency in redish color.

  • PDF

Trend change of dental filling materials for permanent teeth of primary and middle school children in a city (일부 도시 초·중등 학생들의 재료별 영구치 충전율 변화)

  • Kong, Wook Sung;Kim, Cheoul Sin
    • The Journal of the Korean dental association
    • /
    • v.55 no.5
    • /
    • pp.339-350
    • /
    • 2017
  • The aim of the study was to analyze the distribution of dental filling materials for carious permanent teeth of school children in a city. The study was designed as time-serial study, using the data of the dental survey for children aged 8-, 10- and 12-year children living in Gimhae city. The samples were selected by stratified clusters sampling. The number of surveyed samples in depth-analysis for types of dental filling materials were 567 in 2009 and 331 in 2013, respectively. They had dental restorations on one or more teeth. The changing pattern of used dental filling materials was analyzed between 2009 and 2013. Statistical analysis was conducted according to variables related to dental filling material type; DMFT and DMFS index, number of fissure sealed teeth and surface and surveyed year. Amalgam filling rate decreased from 27.9% in 2009 to 18.8% in 2013, while filling rate of tooth-colored materials increased from 56.1% in 2009 and 68.9% in 2013. Amalgam filling rate was a negative correlation with filling rate of tooth-colored materials or gold and number of fissure sealed teeth and a positive correlation with DMFT index. Filling rate of tooth-colored materials was a negative correlation with filling rate of amalgam or gold and DMFT index and a positive correlation with number of fissure sealed teeth. The light-curing composite resin should be included in the reimbursement range of National Health Insurance to solve an inequity of dental health care services.

  • PDF

A STUDY ON THE FRACTURE OF DENTAL AMALGAM (치과용 아말감의 파절에 관한 연구)

  • Huh, Hyeon-Do;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.9 no.1
    • /
    • pp.101-106
    • /
    • 1983
  • It was the purpose of this study to investigate the fracture mode of dental amalgam by observing the crack propagation, and to relate this to the microstructure of the amalgam. Caulk 20th Century Regular, Caulk Spherical, Dispersalloy, and Tytin amalgam alloys were used for this study. After each amalgam alloy and Hg measured exactly by the balance was triturated by the mechanical amalgamator (Capmaster, S.S. White), the triturated mass was inserted into the cylindrical metal mold which was 4 mm in diameter and 12 mm in height and was pressed by the Instron Universal Testing Machine at the speed of 1mm/min with 120Kg. The specimen removed from the mold was stored in the room temperature for a week. This specimen was polished with the emery papers from #100 to #200 and finally on the polishing cloth with 0.06${\mu}Al_2O_3$ powder suspended in water. The specimen was placed on the Instron testing machine in the method similar to the diametral tensile test and loaded at the crosshead speed of 0.05mm/min. The load was stopped short of fracture. The cracks on the polished surface of specimen was examined with scanning electron microscope (JSM-35) and analyzed by EPMA (Electron probe microanalyzer). The following results were obtained. 1. In low copper lathe-cut amalgam, the crack went through the voids and ${\gamma}_2$ phase, through the ${\gamma}_1$ phase around the ${\gamma}$ particles. 2. In low copper spherical amalgam, it was observed that the crack passed through the ${\gamma}_2$ and ${\gamma}_1$ phase, and through the boundary between the ${\gamma}_1$ and ${\gamma}$ phase. 3. In high copper dispersant (Dispersalloy) amalgam, the crack was found to propagate at the interface between the ${\gamma}_1$ matrix and reaction ring around the dispersant (Ag-Cu) particles, and to pass through the Ag-Sn particles. 4. In high copper single composition (Tytin) amalgam, the crack went through the ${\gamma}_1$ matrix between ${\eta}$ crystals, and through the unreacted alloy particle (core).

  • PDF

Changes in Urinary Mercury Levels after Removal of Amalgam Fillings (어린이에서 구강내 아말감 제거 후 요중 수은농도 변화)

  • Jin, Hye-Jung;Sakong, Joon;Song, Keun-Bae;Jeon, Eun-Suk;Kim, Ki-Rim;Choi, Youn-Hee
    • Journal of dental hygiene science
    • /
    • v.15 no.2
    • /
    • pp.190-195
    • /
    • 2015
  • The objective of this study is to estimate the relationship between amalgam removal and urinary mercury levels. To measure urinary mercury concentration, urine of participants was collected at baseline, immediately, 24 hours and 48 hours after removal of amalgam restorations. The statistical analysis was performed using IBM SPSS Statistics ver. 20.0. The overall mean urinary mercury concentration at baseline, immediately, 24 hours and 48 hours after removal of amalgam restorations was 2.77, 2.75, 2.95 and $4.00{\mu}g/g$ creatinine, respectively. Logistic regression model shows that the gender leads to increased odds of high urinary mercury concentration in children (odds ratio, OR=1.99), even after adjusting for high amalgam surfaces (OR=1.23) and fish consumption (OR=1.26) at the baseline. Our findings suggest that mercury exposure from dental amalgam adversely impact health and therefore are a health risk.

THE RETENTION OF FULL VENEER GOLD CROWN BY CORE MATERIAL AND DENTAL CEMENT (Core와 시멘트의 종류가 전부주조금관의 유지력에 미치는 영향)

  • Ha Jum-Im;Cho Hye-Won;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.1
    • /
    • pp.93-101
    • /
    • 1992
  • The purpose of this study was to evaluate the effectiveness of core materials and luting agents on the retention of full veneer gold crown. The core materials used in this study was dental amalgam, and composite resin, and the luting agents were zinc phosphate cement, polycarboxylate cement, and glass ionomer cement. The obtained results were as follows. 1. In full veneer gold crown supported by composite resin core, the crown retention with zinc phosphate cement was the highest of all. 2. In full veneer gold crown supported by amalgam core, the crown retention was shown no statistical difference by luting agent. 3. There was no statistical difference in the crown retention between the full veneer gold crown supported by composite resin core and dental amalgam core.

  • PDF