• Title/Summary/Keyword: Dental Radiography

Search Result 511, Processing Time 0.03 seconds

Formation of ghost images due to metal objects on the surface of the patient's face: A pictorial essay

  • Ramos, Barbara Couto;da Silva Izar, Bruna Raquel;Pereira, Jessica Lourdes Costa;Souza, Priscilla Sena;Valerio, Claudia Scigliano;Tuji, Fabricio Mesquita;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.63-68
    • /
    • 2016
  • Panoramic radiographs are a relatively simple technique that is commonly used in all dental specialties. In panoramic radiographs, in addition to the formation of real images of metal objects, ghost images may also form, and these ghost images can hinder an accurate diagnosis and interfere with the accuracy of radiology reports. Dentists must understand the formation of these images in order to avoid making incorrect radiographic diagnoses. Therefore, the present study sought to present a study of the formation of panoramic radiograph ghost images caused by metal objects in the head and neck region of a dry skull, as well as to report a clinical case in order to warn dentists about ghost images and to raise awareness thereof. An understanding of the principles of the formation of ghost images in panoramic radiographs helps prevent incorrect diagnoses.

Laterally positioned flap using subepithelial connective tissue graft for iatrogenic gingival recession treatment (상피하결합조직 이식을 동반한 측방변위 판막술을 통한 의원성 치은퇴축 치료 증례보고)

  • Lee, Sung-Jo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.330-337
    • /
    • 2016
  • Gingival recession could occur after orthodontic or endodontic treatment. This could influence not only functional and aesthetic problem, but also patient's treatment satisfaction. There are a lot of techniques for preventing gingival recession, but laterally positioned flap with subepithelial connective tissue graft could get definite advantages such as increase of keratinized gingival width and harmonious color match between graft tissue and surrounding tissue. Clinician should select a right patient case and diagnosis with clinical and radiography exam. In a surgical procedure, getting enough amounts of subepithelial connective tissue and flap coverage should be taken into consideration. The clinical outcomes in this case report shows laterally positioned flap with subepithelial connective tissue graft could be a treatment with predictive outcome.

The effects of image acquisition control of digital X-ray system on radiodensity quantification

  • Seong, Wook-Jin;Kim, Hyeon-Cheol;Jeong, Soocheol;Heo, Youngcheul;Song, Woo-Bin;Ahmad, Mansur
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.3
    • /
    • pp.146-153
    • /
    • 2013
  • Objectives: Aluminum step wedge (ASW) equivalent radiodensity (eRD) has been used to quantify restorative material's radiodensity. The aim of this study was to evaluate the effects of image acquisition control (IAC) of a digital X-ray system on the radiodensity quantification under different exposure time settings. Materials and Methods: Three 1-mm thick restorative material samples with various opacities were prepared. Samples were radiographed alongside an ASW using one of three digital radiographic modes (linear mapping (L), nonlinear mapping (N), and nonlinear mapping and automatic exposure control activated (E)) under 3 exposure time settings (underexposure, normal-exposure, and overexposure). The ASW eRD of restorative materials, attenuation coefficients and contrasts of ASW, and the correlation coefficient of linear relationship between logarithms of gray-scale value and thicknesses of ASW were compared under 9 conditions. Results: The ASW eRD measurements of restorative materials by three digital radiographic modes were statistically different (p = 0.049) but clinically similar. The relationship between logarithms of background corrected grey scale value and thickness of ASW was highly linear but attenuation coefficients and contrasts varied significantly among 3 radiographic modes. Varying exposure times did not affect ASW eRD significantly. Conclusions: Even though different digital radiographic modes induced large variation on attenuation of coefficient and contrast of ASW, E mode improved diagnostic quality of the image significantly under the underexposure condition by improving contrasts, while maintaining ASW eRDs of restorative materials similar. Under the condition of this study, underexposure time may be acceptable clinically with digital X-ray system using automatic gain control that reduces radiation exposure for patient.

Head and neck radiotherapy-induced changes in dentomaxillofacial structures detected on panoramic radiographs: A systematic review

  • Munhoz, Luciana;Nishimura, Danielle Ayumi;Iida, Christyan Hiroshi;Watanabe, Plauto Christopher Aranha;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.223-235
    • /
    • 2021
  • Purpose: This study aimed to summarize the impact of neck and head radiation treatment on maxillofacial structures detected on panoramic radiographs. Materials and Methods: In this systematic review, the authors searched PubMed Central, Embase, Scopus, Cochrane Central Register of Controlled Trials, Web of Science, and Google Scholar for original research studies up to February 2020 that included the following Medical Subject Headings keywords: words related to "radiotherapy" and synonyms combined with keywords related to "panoramic radiography" and "oral diagnosis" and synonyms. Only original studies in English that investigated the maxillofacial effects of radiotherapy via panoramic radiographs were included. The quality of the selected manuscripts was evaluated by assessing the risk of bias using Cochrane's ROBINS-I tool for non-randomized studies. Results: Thirty-three studies were eligible and included in this review. The main objectives pertained to the assessment of the effects of radiation on maxillofacial structures, including bone architecture alterations, periodontal space widening, teeth development abnormalities, osteoradionecrosis, and implant bone loss. The number of participants evaluated ranged from 8 to 176. Conclusion: The interaction between ionizing radiation and maxillofacial structures results in hazard to the tissues involved, particularly the bone tissue, periosteum, connective tissue of the mucosa, and endothelium. Hard tissue changes due to radiation therapy can be detected on panoramic radiographs.

Detection of different foreign bodies in the maxillofacial region with spiral computed tomography and cone-beam computed tomography: An in vitro study

  • Abolvardi, Masoud;Akhlaghian, Marzieh;Shishvan, Hadi Hamidi;Dastan, Farivar
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.291-298
    • /
    • 2020
  • Purpose: The detection and exact localization of penetrating foreign bodies are crucial for the appropriate management of patients with dentoalveolar trauma. This study compared the efficacy of cone-beam computed tomography (CBCT) and spiral computed tomography (CT) scans for the detection of different foreign bodies composed of 5 frequently encountered materials in 2 sizes. The effect of the location of the foreign bodies on their visibility was also analyzed. Materials and Methods: In this in vitro study, metal, tooth, stone, glass, and plastic particles measuring 1×1×1 mm and 2×2×2 mm were prepared. They were implanted in a sheep's head in the tongue muscle, nasal cavity, and at the interface of the mandibular cortex and soft tissue. CBCT and spiral CT scans were taken and the visibility of foreign bodies was scored by 4 skilled maxillofacial radiologists who were blinded to the location and number of foreign bodies. Results: CT and CBCT were equally accurate in visualizing metal, stone, and tooth particles of both sizes. However, CBCT was better for detecting glass particles in the periosteum. Although both imaging modalities visualized plastic particles poorly, CT was slightly better for detecting plastic particles, especially the smaller ones. Conclusion: Considering the lower patient radiation dose and cost, CBCT can be used with almost equal accuracy as CT for detecting foreign bodies of different compositions and sizes in multiple maxillofacial regions. However, CT performed better for detecting plastic particles.

Imaging features of Stafne bone defects on computed tomography: An assessment of 40 cases

  • Morita, Lucas;Munhoz, Luciana;Nagai, Aline Yukari;Hisatomi, Miki;Asaumi, Junichi;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.81-86
    • /
    • 2021
  • Purpose: This study was performed to assess and describe the imaging features of 40 cases of Stafne bone defects (SBDs) on computed tomographic (CT) examinations. Materials and Methods: This study collected data, including age and sex, from 40 patients with SBDs who underwent CT exams. The imaging features of the SBDs were assessed in terms of their location, average size, the relationship of their contour with the cortical plate of the lingual mandible, bone margins, degree of internal density, shape, topographic relationship between the defect and the mandibular edge, the distance from the SBD to the base of the mandible, and the Ariji classification (type I, II, and III). Results: The average age was 57.3 years(range, 28-78 years), and the patients were predominantly male (70%). In all cases (100%), the posterior unilateral lingual SBD variant was observed. Within the Ariji classification, type I was the most common (60%). Among the most frequently observed radiographic characteristics were thick sclerotic bone margin across the entire defect contour, completely hypointense internal content, an oval shape, and continuity with the mandibular base with discontinuity of the mandibular edge. Conclusion: This study showed that posterior SBDs could present with an oval or rounded shape, complete hypodensity, and thick sclerotic margins. Likewise, SBDs could appear almost anywhere, with minor differences from the classic SBD appearance. It is fundamental for dental practitioners to know the imaging features of SBDs, since they are diagnosed primarily based on imaging.

Sex determination from lateral cephalometric radiographs using an automated deep learning convolutional neural network

  • Khazaei, Maryam;Mollabashi, Vahid;Khotanlou, Hassan;Farhadian, Maryam
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.239-244
    • /
    • 2022
  • Purpose: Despite the proliferation of numerous morphometric and anthropometric methods for sex identification based on linear, angular, and regional measurements of various parts of the body, these methods are subject to error due to the observer's knowledge and expertise. This study aimed to explore the possibility of automated sex determination using convolutional neural networks(CNNs) based on lateral cephalometric radiographs. Materials and Methods: Lateral cephalometric radiographs of 1,476 Iranian subjects (794 women and 682 men) from 18 to 49 years of age were included. Lateral cephalometric radiographs were considered as a network input and output layer including 2 classes(male and female). Eighty percent of the data was used as a training set and the rest as a test set. Hyperparameter tuning of each network was done after preprocessing and data augmentation steps. The predictive performance of different architectures (DenseNet, ResNet, and VGG) was evaluated based on their accuracy in test sets. Results: The CNN based on the DenseNet121 architecture, with an overall accuracy of 90%, had the best predictive power in sex determination. The prediction accuracy of this model was almost equal for men and women. Furthermore, with all architectures, the use of transfer learning improved predictive performance. Conclusion: The results confirmed that a CNN could predict a person's sex with high accuracy. This prediction was independent of human bias because feature extraction was done automatically. However, for more accurate sex determination on a wider scale, further studies with larger sample sizes are desirable.

Effect of deep transfer learning with a different kind of lesion on classification performance of pre-trained model: Verification with radiolucent lesions on panoramic radiographs

  • Yoshitaka Kise;Yoshiko Ariji;Chiaki Kuwada;Motoki Fukuda;Eiichiro Ariji
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.27-34
    • /
    • 2023
  • Purpose: The aim of this study was to clarify the influence of training with a different kind of lesion on the performance of a target model. Materials and Methods: A total of 310 patients(211 men, 99 women; average age, 47.9±16.1 years) were selected and their panoramic images were used in this study. We created a source model using panoramic radiographs including mandibular radiolucent cyst-like lesions (radicular cyst, dentigerous cyst, odontogenic keratocyst, and ameloblastoma). The model was simulatively transferred and trained on images of Stafne's bone cavity. A learning model was created using a customized DetectNet built in the Digits version 5.0 (NVIDIA, Santa Clara, CA). Two machines(Machines A and B) with identical specifications were used to simulate transfer learning. A source model was created from the data consisting of ameloblastoma, odontogenic keratocyst, dentigerous cyst, and radicular cyst in Machine A. Thereafter, it was transferred to Machine B and trained on additional data of Stafne's bone cavity to create target models. To investigate the effect of the number of cases, we created several target models with different numbers of Stafne's bone cavity cases. Results: When the Stafne's bone cavity data were added to the training, both the detection and classification performances for this pathology improved. Even for lesions other than Stafne's bone cavity, the detection sensitivities tended to increase with the increase in the number of Stafne's bone cavities. Conclusion: This study showed that using different lesions for transfer learning improves the performance of the model.

Comparative study on the radiopacity of different resin-based implant cements (레진계 임플란트용 시멘트의 방사선 불투과성에 대한 비교연구)

  • Han, Kyeong-Hwan;Cheon, Ho-Young;Kim, Min-Su;Shin, Sang-Wan;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.97-104
    • /
    • 2014
  • This study was aimed to compare the radiopacity of four kinds of currently available resin based implant cements using digital radiography. Materials and Methods: Four resin-based implant cements((Estemp $Implant^{TM}$ (Spident, Incheon, Korea), $Premier^{(R)}$Implant (Premier, Pennsylvania, USA), $Cem-Implant^{TM}$ (B.J.M lab, Or-yehuda, Israel), $InterCem^{TM}$ (SCI-PHARM, California, USA)) and control group (Elite Cement $100^{TM}$ (GC, Tokyo, Japan) ) were mixed and cured according to the manufacturer's instructions on the custom made split-type metal mold. A total of 150 specimens of each cement were prepared and each specimen (purity over 99%) was placed side-by-side with an aluminum step wedge for image taking with Intraoral X-ray unit (Esx, Vatech, Korea) and digital X-ray sensor (EzSensor, Vatech, Korea). For the evaluation of aluminum wedge equivalent thickness (mm Al), ImageJ 1.47 m (Wayne Rasband, National Institutes of Health, USA) and Color inspector 3D ver 2.0 (Interaktive Visualisierung von Farbraumen, Berlin, Germany) programs were used. Result: Among the 5 cements, Elite cement $100^{TM}$ (control group) showed the highest radio-opacity in all thickness. In the experimental group, $InterCem^{TM}$ had the highest radio-opacity followed by $Premier^{(R)}$ Implant $Cement^{TM}$, $Cem-Implant^{TM}$ and Estemp $Implant^{TM}$. In addition, $InterCem^{TM}$ showed radio-opacity that met the ISO No. 4049 standard in all the tested specimen thickness. Cem-Implant on 0.5 mm thickness showed radiopacity that met the ISO No. 4049 standard. Conclusion: Among the implant resin-based cements tested in the study, $Premier^{(R)}$ Implant Cement and Estemp $Implant^{TM}$ did not show appropriate radio-opacity. Only $InterCem^{TM}$ and $Cem-Implant^{TM}$ 0.5 mm specimen had the proper radiopacity and met the experiment standard.

DISTRIBUTION OF ABSORBED DOSES TO THE IMPORTANT ORGANS OF HEAD AND NECK REGION IN PANORAMIC RADIOGRAPHY (파노라마 촬영시 두경부 주요기관에 대한 흡수선량 분포)

  • Kim Byeong Sam;Choi Karp Shik;Kim Chin Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.253-264
    • /
    • 1990
  • The purpose of this study was to estimate the distribution of absorbed doses of each important organs of head and neck region in panoramic radiography. Radiation dosimetry at internal anatomic sites and skin surfaces of phantom (RT-210 Humanoid Head & Neck Section/sup R/) was performed with lithium fluoride (TLD-100/sup R/) thermoluminescent dosimeters according to change of kilovoltage (65kVp, 75kVp and 85kVp) with 4 miliamperage and 20 second exposure time. The results obtained were as follows; Radiation absorbed doses of internal anatomic sites were presented the highest doses of 1.04 mGy, 1.065 mGy and 2.09 mGy in nasopharynx, relatively high doses of 0.525 mGy, 0.59 mGy and 1.108 mGy in deep lobe of parotid gland, 0.481 mGy, 0.68 mGy and 1.191 mGy in submandibular gland. But there were comparatively low doses of 0.172 mGy and 0.128 mGy in eyes and thyroid gland that absorbed dose was estimated at 85kVp. Radiation absorbed doses of skin surfaces were presented the highest doses of 1. 263 mGy, 1.538 mGy and 2.952 mGy in back side of first cervical vertebra and relatively high doses of 0.267 mGy, 0.401 mGy and 0.481 mGy in parotid gland. But there were comparatively low doses of 0.057 mGy, 0.068 mGy and 0.081 mGy in philtrum and 0.059 mGy in middle portion of chin that absorbed dose was estimated at 85kVp. According to increase of kilovoltage, the radiation absorbed doses were increased 1.1 times when kilovolt age changes from 65kVp to 75kVp and 1.9 times when kilovolt age changes from 75kVp to 85kVp at internal anatomic sites. According to increase of kilovoltage, the radiation absorbed doses were increased 1.3 times when kilovolt age changes from 65kVp to 75kVp and 1.6 times when kilovoltage changes from 75kVp to 85kVp at skin surfaces.

  • PDF