• Title/Summary/Keyword: Dental Procedure

Search Result 925, Processing Time 0.027 seconds

OSTECTOMIES FOR MANDIBULAR ANGLE REDUCTION: A SYSTEMATIC REVIEW AND A REPORT OF CASES (하악 우각부 축소를 위한 골절제술의 체계적 고찰 및 증례 보고)

  • Park, Jun-Woo;Choi, Jin-Young;Kim, Hyung-Wook;Kim, Jong-Sik;Choung, In-Won;Kang, Jin-Han;Hong, Soon-Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.4
    • /
    • pp.340-352
    • /
    • 2007
  • In this systematic review on bone reduction procedures for the correction of the prominent mandibular angle, we collected and sorted the methods. The strength and weakness, indication, complication, and final esthetic result of each method were evaluated. After searching and filtering the literatures on the base of inclusion criteria, 9 eligible case series studies were included in this study. There were 3 types of curved ostectomies and 4 types of lateral cortical ostectomies. Surgical procedures for curved ostectomies were divided into 2 types. One was single curved ostectomy and the other was multistaged curved ostectomy. Lateral cortical ostectomies reported were all similar to sagittal split ramus osteotomy. The complications reported in the included studies were scarce, but curved ostectomies may be able to induce many complications. The prominent mandibular angle must be analyzed in the lateral dimension and frontal dimension, and curved ostectomy can reduce the mandibular angle laterally while lateral cortical ostectomy can reduce the bigonial distance frontally. Because curved ostectomies can induce complications and unnaturally large mandibular angle while can not reduce bigonial distance efficiently, the current trend for the angle reduction procedure is lateral cortical ostectomies.

EFFECTS ON ER,CR:YSGG LASER ON PERI-IMPLANTITIS (임프란트 주위염에 대한 Er,Cr:YSGG 레이저 조사가 미치는 영향)

  • Choi, Sung-Lim;Kim, Jin-Hwan;Hwang, Dong-Hyeon;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.428-436
    • /
    • 2008
  • For Longevity of implant, considerations of biomechanical and microbiological aspects must be done. Recently, due to the remarkable development of bone grafting procedure. Implant has been implanted into the more favorable sites but peri-implantitis resulted from periodontal bacteria may obscure the long-term prognosis. Although many different modalities have been introduced to treat the failed implant. Implant's surface and irreversible bony destruction around the implant prevents good result. After Er,Cr:YSGG (waterlase) laser using the wave-length of 2780nm has been introduced to dental field, good results have been reported. Because waterlase uses the hydrokinetic force of water. It is excellent device to detoxify the implant surface mechanically without the heat generation and damage to the implant surface. We designed to evaluate waterlase effect on the peri-implantitis has been occurred after implantation. Four beagle dogs were involved. We have made four premolar extraction in each right and left side of the lower jaw and placed two implants in the anterior of the jaw as a control and six implant were placed posterior in each socket after extraction immediately as an experimental group. We tied floss-silk in each implant to make peri-implantitis intentionally. After three months, we explored peri-implant sites on each experimental fixtures. Using waterlase laser irradiation was performed on that implantitis sites under 3W, air 30% and water 20% intensity for 2 minutes. In control group, we repositioned the flap to cover the exposed fixture without any supportive care. Three months later, we sacrificed experimental animals and extracted and preparated bone blocks with Donath and Breuner (982), Donath (988)'s methods and examined under microscope. We have obtained good re-osseointegration around fixtures after treating with waterlaser irradiation. But it was shown fibroosseointegration in the control group.

THE USE OF AUTOLOGOUS VENOUS BLOOD FOR MAXILLARY SINUS FLOOR AUGMENTATION IN CONJUNCTION WITH THE SINUS MEMBRANE ELEVATION : AN EXPERIMENTAL STUDY (상악동 점막 거상 술식에서 자가 정맥 혈액의 사용이 상악동 저 증강에 미치는 영향)

  • Kim, Ha-Rang;Mo, Dong-Yub;Lee, Chun-Ui;Yoo, Jae-Ha;Choi, Byung-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.346-352
    • /
    • 2009
  • There have been reports of successful bone formation with sinus floor elevation by simply elevating the maxillary sinus membrane and filling the sinus cavity below the lifted sinus membrane with a blood clot. But, in a review of the current literature, we found no animal study that substantiated blood clot's ability in this respect. The aim of this study was to investigate the effect of the method of maxillary sinus floor augmentation using the patient's own venous blood in conjunction with a sinus membrane elevation procedure. An implant was placed bilaterally in the maxillary sinus of six adult mongrel dogs so that it protruded 8 mm into the maxillary sinus after sinus membrane elevation. On one side of the maxillary sinus, the resultant space between the membrane and the sinus floor was filled with autologous venous blood retrieved from the dog. On the opposite side, the maxillary sinus was left untreated as a control. The implants were left in place for six months. The mean height of the newly formed bone in the sinus was 3.7 mm on the side without venous blood and 3.5 mm on the side with venous blood (p>0.05). There was no difference between the two sides regarding new bone height in the sinus. Our results indicate that filling the space between the lifted sinus membrane and the sinus floor with venous blood has no effect on bone formation around implants placed in the maxillary sinus cavity.

A comparative clinical study on oxidized titanium implants and sandblasted large-grit acid etched implants in soft bone

  • Lee, Jun-Young;Song, Ji-Eun;Jung, Ui-Won;Kim, Chang-Sung;Choi, Seong-Ho;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.sup2
    • /
    • pp.205-212
    • /
    • 2009
  • Purpose: The aim of this retrospective study was to compare the survival rate of oxidized titanium implants and sandblasted large-grit acid etched implants in soft bone. Methods: 201 oxidized titanium implants were inserted in 84 patients between May 1999 and May 2004. 120 sandblasted large-grit acid etched implants were inserted in 74 patients between December 2000 and May 2004. The patients were followed-up 0${\sim}$5 years in ITI group or 0${\sim}$6 years in BRA group, respectively. The following information was collected from the patient records: age, gender, systemic disease, implant type, number, length and diameter of the implants, their location in the jaws, bone quantity, the number of failed implants, the causes of failure, and advanced surgery for bone augmentation. Results: In the oxidized titanium implants, 8 implants showed early failure, and 1 implant showed late failure, respectively. The cumulative survival rate was 95.48%. In the sandblasted large-grit acid etched implants, 1 implant showed late failure and cumulative survival rate was 99.10%. The cumulative survival rate and the survival rates in the case of the advanced procedure during the implant placement were not significantly different in both groups. Conclusions: Oxidized titanium implants and sandblasted large-grit acid etched implants can be used successfully in soft bone regardless of the surgical methods used during the implant placement. (J Korean Acad Periodontol 2009;39:205-212)

Anatomical Review of Rectus Abdominis Muscle Free Flap for the Oral and Maxillofacial Reconstruction (구강악안면재건을 위한 복직근 유리피판의 해부학적 고찰)

  • Park, Jung Min;Seo, Mi Hyun;Kim, Soung Min;Kang, Ji Young;Myoung, Hoon;Lee, Jong Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.5
    • /
    • pp.367-375
    • /
    • 2012
  • Midfacial reconstruction following resection of extensive malignant oral cavity tumors constitutes a challenging problems for reconstructive surgeons. Rectus abdominis muscle free flap (RAMFF) can be considered as the optimal reconstructive option in this case, because this flap has some advantages including consistent deep inferior epigastric artery anatomy, easy to dissect with well defined skin boundaries, acceptable donor site morbidity and the ability to perform simultaneous flap harvest with oral cancer ablation surgery. The rectus abdominis muscle forms an important part of the anterior abdominal wall and flexes the vertebral column, which is a long strap-like muscle divided transversely by three tendinous intersections, fibrous bands which are adherent to the anterior rectus sheath, which is thickly enclosed by the rectus sheath, except for the posterior part below the arcuate line that is usually located midway between the umbilicus and symphysis pubis. Below the arcuate line, this muscle lies in direct contact with the transversalis fascia and parietal peritoneum. For the better understanding of RAMFF as a routine reconstructive procedure in oral and maxillofacial surgery, the constant anatomical findings muse be learned and memorized by the young doctors in the course of the special curriculum periods for the Korean national board of oral and maxillofacial surgery. This review article will discuss the anatomical basis of RAMFF with Korean language.

Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews

  • Yun, Soon-Dong;Choi, Sung-Hwan;Cha, Jung-Yul;Yu, Hyung-Seog;Kim, Kwang-Mahn;Kim, Jin;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.47 no.4
    • /
    • pp.238-247
    • /
    • 2017
  • Objective: The aim of this study was to compare recycled and unused orthodontic miniscrews to determine the feasibility of reuse. The comparisons included both miniscrews with machined surfaces (MS), and those with etched surfaces (ES). Methods: Retrieved MS and ES were further divided into three subgroups according to the assigned recycling procedure: group A, air-water spray; group B, mechanical cleaning; and group C, mechanical and chemical cleaning. Unused screws were used as controls. Scanning electron microscopy, energy-dispersive X-ray spectrometry, insertion time and maximum insertion torque measurements in artificial bone, and biological responses in the form of periotest values (PTV), bone-implant contact ratio (BIC), and bone volume ratio (BV) were assessed. Results: Morphological changes after recycling mainly occurred at the screw tip, and the cortical bone penetration success rate of recycled screws was lower than that of unused screws. Retrieved ES needed more thorough cleaning than retrieved MS to produce a surface composition similar to that of unused screws. There were no significant differences in PTV or BIC between recycled and unused screws, while the BV of the former was significantly lower than that of the latter (p < 0.05). Conclusions: These results indicate that reuse of recycled orthodontic miniscrews may not be feasible from the biomechanical aspect.

An Evaluation of the Repetitive Tooth Bleaching with Nonthermal Atmospheric Pressure Plasma

  • Nam, Seoul Hee;Kim, Gyoo Cheon;Hong, Jin Woo
    • International Journal of Oral Biology
    • /
    • v.41 no.4
    • /
    • pp.243-251
    • /
    • 2016
  • This study was undertaken to achieve a high bleaching efficacy with plasma, through longer application and reparative bleaching processes, by different shade evaluation methods. Extracted human teeth were divided into 6 groups (n=10). All teeth were treated in pairs. Low concentration of 15% carbamide peroxide (CP) was applied, with and without plasma, for 10, 20, and 30-min tooth bleaching, respectively. The bleaching procedure was repeated once daily for four days. The teeth were maintained in a moist environment provided by artificial saliva. The Vitapan Classical shade guide and Commission Internationale de L'Eclairage (CIELAB) color system were collectively used to measure the bleaching efficacy. Color evaluation was statistically analyzed using Student t-test and one-way analysis of variance (ANOVA) complemented by Tukey's test. Combining the plasma with 15% CP showed significantly greater color changes compared to bleaching without plasma (p<0.05). A high bleaching efficacy with plasma is proportional to the repetitive application and the treatment time. A 30-min application with plasma provided the best bleaching. Repetitive bleaching showed lower probability of color relapse of the bleached tooth. The color change by shade guide correlated with the changes in CIELAB color system. A value of 1 color change units (CCU) conversion factor for overall color change (${\Delta}E$) values comparisons was 3.724 values. The two measuring methods provide a more accurate correspondence of color change. The repetitive and longer application for tooth bleaching, combined with plasma, has a strong bleaching effect and produces whiter teeth.

THE COMPARATIVE STUDY FOR OCCLUSAL PLANE BETWEEN ARTICULATED CAST MODEL AND CEPHALOGRAM IN ORTHOGANTIHIC SURGERY PATIENTS (악교정수술 환자에서 교합기 석고 모형과 측면두부방사선사진의 교합평면에 관한 비교 연구)

  • Seo, Kyung-Suk;Park, Mi-Hwa;Lee, Ju-Hyun;Kim, Chul-Hwan;Chae, Jong-Moon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.239-244
    • /
    • 2003
  • The common errors in preoperative treatment plan for the orthognathic surgery can be occurred during cast impression, cast mounting procedure with face-bow transfer, surgical stent fabrication, and so on. One of the most common errors exists during mounting process of the model on the articulator. Accurate mounting of dental casts to articulator should be achieved by transferring the 3-dimensional spatial relationship of the maxillary arch to an articulator. A face-bow is used for transfer this relationship to articulator, usually by relating the face-bow to a plane of reference of maxillary cast. The purpose of this study is evaluation of the accuracy of face-bow transferring of maxillary model to the articulator. The maxillary casts of thirty patients for orthognathic surgery were mounted on articulator with an face-bow instrument. The relationship of occlusal plane angle to Frankfort horizontal plane relations were compared the cephalogram with the cast-mounted articulator. As a result of this study, the significant difference between the maxillary occlusal planes angle in the cephalogram and articulator were found. The results were followed, 1. The mean occlusal plane angle in cast-mounted articulator was $13.5^{\circ}\;(SD{\pm}5.4)$. 2. The mean occlusal plane angle in cephalogram was $10.4^{\circ}\;(SD{\pm}4.3)$. 3. The mean difference of occlusal plane angle between cast-mounted articulator and cephalogram was $3.3^{\circ}\;(SD{\pm}4.6)$. According to the result, we should suggest that the occlusal plane angle to Frankfort plane in cast-mounted articulator is more steeper than that of cephalogram. And then, maxillofacial surgeon should try to get a more predictable result by suggesting the proper correction method and mounting the cast accurately.

Reliability study of 6-axis model surgery simulator for orthognathic surgery (6축 모형수술 시뮬레이터의 정확도에 관한 연구)

  • Jeon, Jae-Ho;Lee, Hyung-Chul;Ji, Hyun-Jin;Jeon, Yeong-Jin;Kim, Yong-Il;Son, Woo-Sung;Park, Soo-Byung;Kim, Sung-Sik;Whang, Dae-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.1
    • /
    • pp.23-27
    • /
    • 2010
  • The purpose of this study was to evaluate the reliability of 6-axis model surgery simulator (6AMSS) for orthognathic surgery. A rectangular parallelepiped plastic block was assembled to model-mounting plate of 6AMSS. Left-right (X), anterior-posterior (Y), up-down (Z) translation and pitching (${\phi}X$), rolling (${\phi}Y$) and yawing (${\phi}Z$) rotation was planned and performed using 6AMSS. The actual translation and rotation were measured with dial gauge and precisional protractor, respectively. Comparison between the planned and actual movements of plastic block for each variable were made using paired t- test. Statistical analysis for X, Y, Z, ${\phi}X$, ${\phi}Y$ and ${\phi}Z$ movement have shown no significant differences between planned and actual movement (P > 0.05). This indicate that model surgery performed with the aid of the 6AMSS is accurate in 3D translation and rotation. The 6AMSS is practically useful for accurate fabrication of surgical splint for orthognathic surgery.

HISTOMORPHOMETRIC ANALYSIS OF MAXILLARY SINUS AUGMENTATION WITH DEPROTEINIZED BOVINE BONE(BIO-$OSS^{(R)}$) AND VARIOUS ABSORBABLE MEMBRANE (탈단백 소뼈 기질과 다양한 종류의 흡수성 막을 이용한 상악동 거상술 후의 조직-형태학적 분석)

  • Jang, Tae-Hwa;Jang, Yoon-Je;Kwon, Tae-Geon;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.6
    • /
    • pp.609-616
    • /
    • 2007
  • Purpose: The aim of the present study was to evaluate the effect of Bio-Oss on bone formation in terms of healing period and type of membrane so that determine the most suitable condition for implant fixation in grafted maxilla. Material & Method: Forty-five biopsy specimens from graft site were evaluated. Sinus lift was performed in the patients with reduced alveolar bone height(less than 5mm). The specimen was taken at the time of implant fixation, which was performed at least 5 months after the sinus lift procedure. All specimens were stained with H&E and Trichrome staining and evaluated histomorphometrically. Result: The results showed that Bio-Oss particle was in direct contact with newly formed bone in all cases. In the present study, the amount of newly formed bone and the residual bone substitute material were not statistically different according to various membrane and different healing period. There was no difference between the histological feature of the specimen of 5 and 31 months. No statistical significance was detected between male and female. Conclusion: The result implies that Bio-Oss does not seem to be resorbed over time regardless of the type of the membranes. The further investigation is needed to clarify this issue with the extended period of follow-up.