• 제목/요약/키워드: Dental Prescale

검색결과 9건 처리시간 0.02초

Dental Prescale과 편측 교합력 측정기를 이용한 정상성인의 교합력 비교 (COMPARISON OF BITE FORCE WITH DENTAL PRESCALE AND UNILATERAL BITE FORCE RECORDER IN HEALTHY SUBJECTS)

  • 권호근;유자혜;권영숙;김백일
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.103-111
    • /
    • 2006
  • Statement of problem: The previous unilateral bite force recorder has several limitations for taking long time for measuring and causing discomfort to subjects. Because of these reasons, it could not use widely for epidemiological researches. However, 'Dental Prescale System' which is new equipment for measuring bite force, is more convenient for measuring bite force than previous unilateral recorder. Purpose: The purpose of this study was to compare a new technique(Dental Prescale System) using pressure sensitive foils for recording of maximal jaw closing force with conventional measurement using unilateral bite force recorder Material and method: This studies included 22 healthy dental students in college of dentistry Yonsei university in Rep of Korea. Mean age was 23.9 years. All subjects had continuous dental arches and no significant malocclusion or signs from the teeth and craniomandibular system. The Dental Prescale System (Fuji Film, Tokyo, Japan) consists of a horseshoe-shaped pressure sensitive sheet (50H, R type) and a computerized scanning system.(FPD705) We also used unilateral bite force recorder(Denbotics Co. Seoul, Rep.Korea) for comparing with Dental Prescale. Results and conclusion: The total bite force recorded with Dental Prescale System (1423 N) was systematically higher than that recorded by unilateral bite force recorder. (256 N) However, the maximum bite force values measured in the two ways were significantly correlated (r=0.46, p<0.05). The Dental Prescale bite force calculated for first molar (208 N) was lower than that recorded by unilateral bite force recorder. (256 N) The two values were also very significantly correlated. (r=0.66. p<0.001) There were significantly different in bite force between two measurement methods. The reasons were first, unilateral bite force recorder measured only the bite force of a part of teeth, and Dental Prescale measured the total teeth force. Second, in measurement, a difference in muscle contraction appeared by an extent of mouth-opening. Third, unilateral bite force recorder has the reducing effect of the bite force by protective tape. Fourth, Dental Prescale has limitations during the computer scanning procedure. Therefore, Dental Prescale System is considered to be a very promising alternative to be conventional bite force recording methods.

보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례 (Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report)

  • 최수현;최유성;이종혁;하승룡
    • 대한치과보철학회지
    • /
    • 제61권2호
    • /
    • pp.160-178
    • /
    • 2023
  • 보철 치료 시 교합관계의 진단과 분석은 중요한 요소 중 하나이다. 치료 시행 전 면밀한 교합분석 및 평가가 선행되어 안정적인 악간 관계를 회복시켜 주어야 하며, 치료 과정 및 정기 검진 시에도 이에 대한 평가는 필수적이다. 최근, 치과용 기기와 디지털 처리 방식의 발달로 환자의 교합관계를 기록할 수 있는 새로운 정량적 분석 방법들이 소개되고 있다. 그 중 T-Scan Novus (Tekscan Inc., S. Boston, MA, USA)는 압력측정센서를 이용하여 상하악 치아의 초기접촉점과 교합접촉점의 상대적인 강도를 나타내며 치아의 교합접촉 시간, 교합력의 전후방, 좌우균형을 비교할 수 있다. Dental prescale II (GC Co., Tokyo, Japan)는 압력감지필름을 이용하여 교합접촉점을 스캔하여 접촉점의 밀도를 분석하는 방법으로 최대한 자연스러운 교합상태 치열의 교합력 분포와 강도를 측정할 수 있다. 환자의 치아 상실 부위와 범위에 따라 4-unit 고정성 국소의치, 가철성 국소의치, 총의치, 완전구강회복술을 시행하였다. 적절한 교합 분석을 위해, 초진, 각 치료 단계, 치료 직후 및 정기검진 시의 환자의 교합을 T-Scan Novus와 Dental prescale II를 이용하여 정량적으로 비교, 평가하였다. 보철수복 치료과정에서 교합 분석에 대한 이해도를 제고할 수 있었고, 기능 및 심미적으로 환자와 술자 모두 만족할 만한 결과를 얻었기에 이를 보고하고자 한다.

골유착성 임플랜트 지지 고정성 보철물과 자연치의 최대교합력 비교 (COMPARISON OF MAXIMUM OCCLUSAL FORCES ON OSSEOINTEGRATED IMPLANT SUPPORTED FIXED PROSTHESES AND NATURAL TEETH)

  • 권영숙;황선홍;한동후
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.498-510
    • /
    • 2005
  • Purpose: The purpose of this study was to compare the maximum occlusal force implant prostheses to natural teeth. Material and Method: Fifty nine patients treated either with $Br{\aa}anemark$ implants and ITI implants during the recent ten years were involved in this study. The maximum occlusal force were measured with unilateral bite force recorder and dental prescale system. Results: 1. The maximum occlusal forces of the implant prostheses and natural teeth were not significantly different where measured with unilateral bite force recorder and dental prescale system. 2. The maximum occlusal forces were not significantly different between $Br{\aa}nemark$ implant and ITI implant prostheses. 3. The maximum occlusal forces of the implant prostheses had lower when compared with natural teeth during 1-6 months functional periods when measured with the unilareral bite force recorder(P<0.05) and 1-12 months functional periods when measured with the dental prescale system(P<0.05). After these periods there was not statistical significant difference between the implant prostheses and natural teeth. 4. The maximum occlusal forces of the wide diameter implant prostheses were higher than the maximum occlusal forces of the regular diameter implant prostheses when measured with dental prescale system(P<0.05), but there was no significant difference between the wide diameter and the regular diameter implant prostheses when measured with unilateral bite force recorder. 5. The maximum occlusal forces of the single implant prostheses were not significantly different with the splinting implants prostheses. 6. The maximum occlusal forces of the implant prostheses were not significantly different by age and sex. 7. There was significantly different between maximum occlusal forces measured with unilateral bite force recorder and dental prescale system(P<0.0001) but there was positive correlation(r=0.52. P<0.05). Conclusion: The maximum occlusal forces of the implant prostheses were not significantly different to natural teeth during clenching and unilateral maximum biting.

단일 치관 수복 시 구강스캐너를 이용한 교합평가 활용 증례보고 (A case report of single crown restoration using an intraoral scanner for occlusal evaluation)

  • 송준범;이종혁;하승룡;최유성;최선영
    • 대한치과보철학회지
    • /
    • 제59권3호
    • /
    • pp.341-349
    • /
    • 2021
  • 디지털 방식을 이용한 교합평가는 종래의 방식인 교합지와 occlusion foil 등에 비해 기록, 비교, 분석 등이 쉽고 간편하며 객관적 이라는 장점이 있다. 이에 본 증례보고에서는 교합평가에 디지털 기술을 활용하고자 단일 전장관 수복이 필요한 환자에서 구강스캐너(i500, Medit, Seoul, Korea)를 이용하여 매 내원시 교합을 평가하였으며, 비교를 위하여 교합지를 이용한 교합관계 확인과 디지털 교합분석장비(Dental prescale II, GC corporation, Tokyo, Japan)를 이용하여 교합관계를 평가하였다. 치료과정에서 구강스캐너를 이용한 방법과 기존의 교합지를 이용한 방법이 유사한 결과를 보여 향후 임상적으로 유용하게 사용될 수 있을 것으로 사료되었다.

임상가를 위한 특집 3 - 교합력 측정의 방법과 임상적 적용 (The methods for occlusal force measurement and their clinical applicatio)

  • 박지만;허성주;전윤식
    • 대한치과의사협회지
    • /
    • 제50권1호
    • /
    • pp.22-30
    • /
    • 2012
  • The methods for the occlusal force measurement have long been developed. The occlusal analyzing equipment utilizing the pressure-sensitive film (Prescale) is useful for the assessment and comparison among large group of patients. On the other hand, the apparatus which uses the grid-based sensor sheet (T-scan) can be a useful assistant for acquiring the well-balanced occlusion. The device that can process the electrical input from the strain gauge which is attached to the tooth surface can collect the dynamic data of actual masticatory force. This device has been developed for the measurement of actual mastication with the food bolus and it can be a useful method for the comparison before and after the restorative treatment. Occlusal force measurement can be applied for the analysis of therapeutic action, diagnosis of crack- tooth syndrome, temporomandibul ar disease, and idiopathic implant loosening.

A COMPARISON OF THE MASTICATORY FUNCTION BETWEEN TWO DIFFERENT TYPES OF IMPLANT SUPPORTED PROSTHESES AND COMPLETE DENTURE FOR FULLY EDENTULOUS PATIENTS

  • Lee, Jae-Hoon;Kim, Woo-Hyun;Shin, Rie-Hye;Lee, Keun-Woo
    • 대한치과보철학회지
    • /
    • 제46권6호
    • /
    • pp.591-601
    • /
    • 2008
  • STATEMENT OF PROBLEM: The improvement in oral function and comfort from the dental implant appears to depend on the particular type of implant support used with the denture. The number and positioning of implants have an influence on the force transfer and subsequent stress distribution around implants. Nevertheless, a quantitative comparison has not been made between the types of implant prosthesis used with different materials compared to conventional complete denture. PURPOSE: The objective of this study is to assess the masticatory performance, bite force and impact of two different type of implant supported prostheses on oral health-related quality of life compared to conventional complete denture with GOHAI, validated oral-specific health status measures, the sieving method, and the Prescale Dental System. MATERIAL AND METHODS: From the years 1999 to 2006, a total of 30 completely edentulous patients in a single arch were selected from the Yonsei University Dental Hospital, Department of Prosthodontics and Implant Clinic in Seoul, S. Korea. Patients were divided into 3 groups of 10 each. Group HR was restored with fixed-detachable hybrid prostheses with resin teeth. Group FP had fixed dentures with porcelain teeth while Group CD had a complete denture. The masticatory performance was compared between 3 groups. RESULTS: The results showed a significant improvement in oral health-related quality of life with dental implants compared to a conventional denture in GOHAI comparison. Overall, implant prostheses showed a higher masticatory performance ($S_{50}$) and maximum bite force compared with conventional dentures (P < .05) but no differences between different implant supported prostheses (P > .05). CONCLUSION: Within the limitation of this study, the numbers of implant and material of implant prostheses does not appear to impact patient satisfaction, masticatory performance or bite force.

Comparison of the bite force and occlusal contact area of the deviated and non-deviated sides after intraoral vertical ramus osteotomy in skeletal Class III patients with mandibular asymmetry: Two-year follow-up

  • Kwon, Hyejin;Park, Sun-Hyung;Jung, Hoi-In;Hwang, Woo-Chan;Choi, Yoon Jeong;Chung, Chooryung;Kim, Kyung-Ho
    • 대한치과교정학회지
    • /
    • 제52권3호
    • /
    • pp.172-181
    • /
    • 2022
  • Objective: The objectives of this study were to compare the time-dependent changes in occlusal contact area (OCA) and bite force (BF) of the deviated and non-deviated sides in mandibular prognathic patients with mandibular asymmetry before and after orthognathic surgery and investigate the factors associated with the changes in OCA and BF on each side. Methods: The sample consisted of 67 patients (33 men and 34 women; age range 15-36 years) with facial asymmetry who underwent 2-jaw orthognathic surgery. OCA and BF were taken before presurgical orthodontic treatment, within 1 month before surgery, and 1 month, 3 months, 6 months, 1 year, and 2 years after surgery. OCA and BF were measured using the Dental Prescale System. Results: The OCA and BF decreased gradually before surgery and increased after surgery on both sides. The OCA and BF were significantly greater on the deviated side than on the non-deviated side before surgery, and there was no difference after surgery. According to the linear mixed-effect model, only the changes in the mandibular plane angle had a significant effect on BF (p < 0.05). Conclusions: There was a difference in the amount of the OCA and BF between the deviated and non-deviated sides before surgery. The change in mandibular plane angle affects the change, especially on the non-deviated side, during the observation period.

한국인에서의 부정교합 여부와 골격형태, 연령, 성별에 따른 교합력의 비교 (Comparisons of occlusal force according to occlusal relationship, skeletal pattern, age and gender in Koreans)

  • 윤혜림;최윤정;김경호;정주령
    • 대한치과교정학회지
    • /
    • 제40권5호
    • /
    • pp.304-313
    • /
    • 2010
  • 본 연구는 한국인 정상교합자와 부정교합자 사이의 교합력의 크기와 교합 시의 접촉 면적의 차이 및 골격 형태와 교합 관계, 연령, 성별이 교합력의 크기에 영향을 미치는지 알아보기 위해 시행되었다. 정상교합자 15명, 부정교합자 636명에서 일회용 pressure sensitive sheet (Dental $Prescale^{(R)}$ 50H, typeR, Fuji Film Corp., Tokyo, Japan)를 자연 두부위에서 최대 근력으로 교합하도록 한 후, CCD camera ($Occluzer^{(R)}$ FPD 707, Fuji Film Corp., Tokyo, Japan)로 판독하여 교합력의 크기 및 접촉 면적을 측정하였다. 정상교합자군의 교합력의 크기는 $744.5{\pm}262.6N$, 접촉면적은 $24.2{\pm}8.2mm^2$으로, 부정교합자군의 $439.0{\pm}229.9N$, $12.4{\pm}10.7mm^2$에 비해 교합력의 크기와 접촉 면적이 유의하게 컸다 ($p$ < 0.05). 부정교합자군의 경우 연령에 따른 교합력의 차이는 없었으나, 남자가 여자에 비해 큰 교합력을 가지고 있었다 ($p$ < 0.05). 악안면의 전후방적인 골격 형태를 나타내는 ANB 및 골격성 1급 부정교합에서의 구치부의 Angle 분류는 교합력에 유의한 차이를 나타내지 않았으나, 수직적인 골격 형태를 구분하는 mandibular plane angle, gonial angle이 큰 경우, 교합력이 유의하게 작았다 ($p$ < 0.05). 하지만, 교합력의 크기와 접촉 면적간에는 높은 상관관계가 존재하는 점과 접촉 면적을 통제한 상태에서의 골격 형태와 교합력의 크기 사이에는 유의할 만한 상관관계가 없는 점을 고려한다면 수직적인 골격 형태가 직접적으로 교합력에 영향을 주기보다는 수직적인 골격 형태에 따른 접촉 면적의 감소가 교합력 저하에 관여한다고 판단된다.

덴탈 프리스케일로 평가한 보툴리눔 A형 독소 반복 주사 후 근육의 약화 (Muscle Weakness after Repeated Injection of Botulinum Toxin Type A Evaluated by Dental Prescale)

  • 변영섭;송지희;최영찬;김성택
    • 구강회복응용과학지
    • /
    • 제26권1호
    • /
    • pp.69-75
    • /
    • 2010
  • A형 보툴리눔 독소(botulinum toxin type A, BTX-A)는 교근 비대의 치료에 성공적으로 적용되어 왔지만 주사 부위 근육의 약화를 초래한다. 이 연구는 BTX-A를 사람 교근에 주사한 후 최대 교합력(Maximum Bite Force, MBF) 의 변화를 측정하고, 반복 주사의 효과를 평가하기 위해 시행되었다. 30명의 자원자들을 18주간 추적 관찰하고, 최대 교합력을 측정하였다. 1차 주사로부터 18주가 경과한 후 시술에 만족한 16명은 제외하고 나머지 14명에게 반복 주사를 시행하였고, 다시 18주간 측정하였다. 평균 최대 교합력은 주사 2주 후 20% 감소하였다가 4주부터 점차 회복되었으며, 12주 뒤에는 주사 이전 수준으로 회복되었다. 최대 교합력은 주사 전과 주사 2주, 4주, 8주 후에서 유의한 차이를 보였다(p<.05). 반복 주사군(n=14)의 최대 교합력은 6주에 두드러진 감소를 보였다가(p<.05) 12주간 점차 회복되었다. 실험군이 경험한 불편감의 수준은 일반적인 저작에는 거의 영향을 미치지 않았다.