• 제목/요약/키워드: Dental Impression

검색결과 348건 처리시간 0.021초

신개발 국산 부가중합 실리콘 인상재의 젖음성과 기포발생에 관한 비교 연구

  • 조리라;정경호;김경남
    • 대한치과의사협회지
    • /
    • 제41권1호통권404호
    • /
    • pp.35-41
    • /
    • 2003
  • Wettability of addition silicone impression material is very important property for making an accurate restoration. This study examined theimpression quality in clinical condition and the wettability of impression material. Three commercially available addition silicone impression material (Imprint; 3M, USA, Examix; GC, Japan, Perfect; Handae, Korea) were studied. A total of 90 putty/wash impressions of semi-dried premolars and wet molar teeth were examined for void production in impression body. The percentae of the sulcus reproduction ability of each material was calculated from the sulcus depths of cross-sectioned casts from the impressions with stereomicroscope. Three impression materials were used to produce die stone casts from vcid entrapment die. Voids in the stone casts were counted with the stereomicroscpe. From the experiment, the following results were obtained: 1. In direct observation, Imprint showed greatest numbers of void in impression body (P<.001).However, correlations were not found between sulcus reproduction and void production. 2. Sulcus reproduction ability of additional silicone impression material was diminished in order of Imprint, Examix, Perfect. The significant difference was found between Imprint and other material (P<.001). 3. In void entrapment laboratory test, void productions was diminished in order of Examix, Imprint, Perfect. All voids in casts were less in delayed poured cast than immediately poured cast. 4. Especially, the stone pouring time of Perfect impression material should be delayed.

  • PDF

백색광과 청색광 스캐너를 이용한 지대치 인상체 스캐닝의 반복재현성 비교 (Comparison of reproducibility of prepared tooth impression scanning utilized with white and blue light scanners)

  • 전진훈;성환경;민병국;황재선;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제37권4호
    • /
    • pp.213-218
    • /
    • 2015
  • Purpose: The purpose of this study compared of reproducibility of prepared tooth impression scanning utilized with white and blue light scanners. Methods: To evaluate reproducibility with white and blue light scanners, the impression of premolar were rotated by $10^{\circ}{\sim}20^{\circ}$ and scanned. These data were compared with the first 3-D data (STL file), and the error sizes were measured (n=5). Independent t test was used to evaluation the reproducibility of impression of premolar with white versus blue light scanners through discrepancies of mean, RMS (${\alpha}=0.05$). Results: Discrepancies of mean with regard to reproducibility were $11.2{\mu}m$, $5.8{\mu}m$, respectively, with white and blue light scanners (p<0.047). And discrepancies of RMS with regard to reproducibility were $33.4{\mu}m$, $18.8{\mu}m$, respectively, with white and blue light scanners (p<0.045). Conclusion: Our results indicate a good reproducibility of prepared tooth impression digitized with blue light scanner more than that with white light scanner.

디지털 구강스캐너에 대한 치과위생사의 지식과 태도에 관한 인식도 분석 (Analysis of dental hygienists' perception of knowledge and attitude toward digital oral scanner)

  • 이천희;안선하
    • 한국치위생학회지
    • /
    • 제19권1호
    • /
    • pp.33-44
    • /
    • 2019
  • Objectives: To investigate how dental hygienists who have never used a digital oral scanner perceive the impression acquisition and evidence needed for prosthesis planning by using a digital oral scanner. Methods: From July 1, 2017 to December 31, 2017, subjects from Daegu, Gyeongsangbuk-do, Korea, were selected. The purpose of the study was described to dental hygienists who had never used a digital intraoral scanner. Questionnaires were distributed to the students selected. Of the 137 questionnaires distributed, 93 were used in the analysis after excluding 44 completed questionnaires that had errors or missing answers. Results: Of the respondents, 33.7% (36/93) were aged ${\geq}30$ years, 68.8% graduated from a 3-year vocational college course, 33.5% were aged ${\geq}33$ years, and 61.3%. At present, our center has the largest number of clinics (92.5%). The difficulty of impression taking using the digital oral scanner significantly differed (p<0.05) according to age and current occupation (p<0.05). Impression taking using a digital oral scanner significantly affected the present workflow of dental hygienists and their interest in sharing information about future use of digital oral scanner (p<0.01). Conclusions: If more routes are available to access digital intraoral scanners and more systems are developed for clinical use, the digital intraoral scanner could become digitized in the dental system; thereby, the existing impressions could be replaced with digitized impressions. With digital intraoral scanners, the expansion of the business of dental hygiene can be expected.

Effect of alginate chemical disinfection on bacterial count over gypsum cast

  • Haralur, Satheesh B.;Al-Dowah, Omir S.;Gana, Naif S.;Al-Hytham, Abdullah
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권2호
    • /
    • pp.84-88
    • /
    • 2012
  • PURPOSE. To evaluate the efficacy of sodium hypochlorite (1 : 10) and iodophor disinfectants on alginate impressions along with their effect on the survived bacterium count on the gypsum cast. MATERIALS AND METHODS. Four alginate impression on each dentate patients were made, of which Group I were not washed or disinfected, Group II impressions were merely washed with water, Group III were disinfected by spraying with sodium hypochlorite (1 : 10), Group IV were disinfected with iodophor (1 : 213). Gypsum cast (type III) were made from all the impression. Impressions and gypsum cast were swabbed in mid palatal region for bacterial culture. Bacterial colony counting done after 3 days of incubation at $37^{\circ}C$ in blood agar media. The data obtained was analyzed by one way ANOVA test at a significant difference level of 0.05. RESULTS. Group I and Group II showed significantly more bacteria compared to Group III and Group IV. Bacterial colonies on the alginate impression and gypsum cast in group disinfected with Sodium hypochlorite (1 : 10) were 0.18, 0.82 respectively compared to group treated with iodophor (1 : 213). There was an increase in bacterial count on dental cast compared to source alginate impressions. CONCLUSION. Sodium hypochlorite (1 : 10) was found to be better disinfectant for alginate impression. There was an indication of increase in number of bacteria from alginate impression to making of dental cast. Additional gypsum cast disinfectant procedures need to be encouraged to completely eliminate cross infection to dental laboratory.

몇 치과인상재료의 Flow에 대한 실험적 연구 Flow Studies of Certain Dental Impression materials

  • 김인철;선우양국
    • 대한치과의사협회지
    • /
    • 제4권1호
    • /
    • pp.5-7
    • /
    • 1963
  • The purpose of this investigation was to study the preperty of flow for seven different impression materials presently available in KOREA. In this study ,200 grams of a load was applied at regular intervals. As the result of this study, following points were revealed in terms of flow property of respective materials. 1)Impression plaster and irreversible hydrocolloid impression materials were found to have insufficient working time due to their tendency to set rapidly after mixing. 2)Regarding to impresssion pastes, it was found that it has manifested an ideal flow property until 2 minutes after mixing. Clinically, this material seems to allow sufficient working time for its manipulation.

  • PDF

알지네이트 인상체에 대한 상업성 소독제의 효과 (The effect of disinfectants for Alginate impression)

  • 김선미
    • 한국치위생학회지
    • /
    • 제1권2호
    • /
    • pp.243-250
    • /
    • 2001
  • To evaluate the effect of disinfectants for Alginate impression, several commercially available disinfectants were tested to Alginate model contaminated by Methicillin resistant Staphylococcus aureus. Alginate specimens were artificially contaminated by Staphylococcus aureus and soaking in four commercially available disinfectants for 1, 5, 10 minutes and colonies were counted for each case. Significant reduction of bacterial colony counts was noted after soaking in 0.5% and 0.05% sodium hypochlorite and after soaking in 2% glutaraldehyde, but not after soaking in Hypochlorus add. Commercially available sodium hypochlorite and glutaraldehyde were found to be effective disinfectants for Alginate impression. But hypochlorus add was not adequate disinfectant.

  • PDF

치과용 백색광 스캐너를 이용한 impression scanning의 반복 측정에 대한 안정성 평가 (Evaluation on the repeatability of dental white light scanner-based digital impression)

  • 전진훈;이경탁;김혜영;김지환;김웅철
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.37-42
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the repeatability of dental white light scanner. Methods: The impression(Zerosil, Dreve, Germany) were digitized in white light scanner(Identica, Medit, Korea) to create 3-dimensional surface-models. The distribution of the discrepancies between the number of points in the corresponding CRM models and the point clouds in the others were measured by a matching-software(PowerInspect 2012, Delcam Plc, UK). The discriptive statistics were used for statistical analysis(SPSS 20.0). Results: The measurement of repeatablity showed very good reliability. The mean(SD) discrepancy value on the white light scanner digital models was 8.7(0.67) ${\mu}m$, based on SD and absolute mean values. Conclusion: These in vitro studies showed that repeatability of dental white light scanner is high reliability. These results can be confirmed in further clinical studies.

수종 치과용 석고의 접촉각 및 젖음성에 관한 비교 연구 (A STUDY ON THE CONTACT ANGLE AND WETTABILITY OF THE DENTAL STONES)

  • 조리라;정경호;김경남
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.61-70
    • /
    • 2003
  • The purpose of this study was to investigate the contact angles and wettability of conventional dental stones and improved dental stones and newly developed dental stones on several impression materials. Materials included in this study were several dental stones and newly developed dental stone ; 2 type III stones (Snow Rock, New Diastone), 6 type IV stones(Crystal Rock, Vel Mix, Fuji Rock, Tuff Rock, Resin Rock and newly developed dental stone) and 1 type V stone (Die Keen). Contact angles on the impression materials were measured with contact angle measuring device. Ten specimens for each material, total 180 specimens were made on void entrapment model. The two impression materials (Handae, GC) were used to produce 9 groups of die stone casts form void entrapment model. Voids in the stone casts were counted under a stereoscopic microscope. The grad for the reproduction ability of each materials on the void entrapment model was calculated from the casts by one examiner. From the experiment, the following results were obtained : 1. The newly developed stones showed smallest contact angle. Type III dental stone had larger contact angles than type IV and V stones. Contact angle was much affected by the impression materials. 2. Resin containing die materials such as Tuff Rock and Resin Rock had smallest void number than any other groups. 3. In comparing reproduction parameters, Tuff Rock and Resin Rock presented superior results, while Vel Mix showed lowest reproduction ability.

Accuracy of five implant impression technique: effect of splinting materials and methods

  • Lee, Sang-Jik;Cho, Sung-Bum
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권4호
    • /
    • pp.177-185
    • /
    • 2011
  • PURPOSE. The aim of this study was to evaluate the effect of dimensional stability of splinting material on the accuracy of master casts. MATERIALS AND METHODS. A stainless steel metal model with 6 implants embedded was used as a master model. Implant level impressions were made after square impression copings were splinted using 5 different techniques as follows. (1) Splinted with autopolymerizing resin and sectioned, reconnected to compensate polymerization shrinkage before the impression procedure. (2) Splinted with autopolymerizing resin just before impression procedure. (3) Primary impression made with impression plaster and secondary impression were made over with polyether impression material. (4) Splinted with impression plaster. (5) Splinted with VPS bite registration material. From master model, 5 impressions and 5 experimental casts, total 25 casts were made for each of 5 splinting methods. The distortion values of each splinting methods were measured using coordinate measuring machine, capable of recordings in the x-, y-, z- axes. A one-way analysis of variance (ANOVA) at a confidence level of 95% was used to evaluate the data and Tukey's studentized range test was used to determine significant differences between the groups. RESULTS. Group 1 showed best accuracy followed by Group 3 & 4. Group 2 and 5 showed relatively larger distortion value than other groups. No significant difference was found between group 3, 4, 5 in x-axis, group 2, 3, 4 in y-axis and group 1, 3, 4, 5 in z-axis (P<.0001). CONCLUSION. Both Splinting impression copings with autopolymerizing resin following compensation of polymerization shrinkage and splinting method with impression plaster can enhance the accuracy of master cast and impression plaster can be used simple and effective splinting material for implant impression procedure.

스캐닝 방법에 따른 백색광 스캐너 기반으로 채득된 디지털 모형의 정확성 비교 (Comparison of the accuracy of digital models made from white light scanner by scanning method)

  • 김기백;이경탁;김재홍
    • 한국치위생학회지
    • /
    • 제12권6호
    • /
    • pp.1082-1089
    • /
    • 2012
  • Objectives : The aim of this study was to determine the accuracy of digitized stone models, impression materials compared to the master model and the reliability of the computer aided analysis. Methods : A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Ten vinyl polysiloxane impressions(Examix$^{(R)}$, GC Industrial Corp, Japan) of master model were taken and type IV stone(aesthetic-base gold$^{(R)}$, Dentona, Germany) were poured in stone models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK). The t-student test for paired samples was used for statistical analysis. Results : The mean differences to master model for stone model and impression material were 0.11~0.19mm, and 0.19~0.29mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between master model and stone model/impressions(p<.05). Conclusions : Two different scanning methods showed clinically acceptable accuracy of full arch digital impression produced by them. These results will have to be confirmed in further clinical studies.