• Title/Summary/Keyword: Dental Impression

Search Result 348, Processing Time 0.097 seconds

The correlation among the oral & facial states and the gummy smile in female college students (일부 여대생의 구강 및 안모상태와 치은노출(Gummy smile)과의 상관성)

  • So, Mi-Hyun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.2
    • /
    • pp.345-353
    • /
    • 2012
  • Objectives : The author has studied about correlation of gingival exposure upon smiling and oral facial status that reduce facial aesthetic. Methods : The subjects in this study are 91 female vulunteers who were in aged $21.4{\pm}1.89$ in Suwon. Objectives should be normal oral and facial status without the prosthodontic, orthodontic appliance or conqenital missing tooth, and agree to be examined the oral status and impression taking. 1.Measure the length of gingival exposure upon smiling. 2.Measure of the size on central incisor. 3.Measure of Facial. SPSS(SPSS 10.0 for windows, SPSS Inc, Chicago, USA) was utilized for calculating the correlation coefficient between gingival exposure upon smiling and facial status. Regression analysis was calculated in order to predict the R square for gingival exposure upon smiling. Results : 1.Correlation coefficient between the gingival exposure and length of maxillary central incisor was calculated as reversed correlation(r=-.302, p<0.01), and between the gingival exposure and the ratio of the length of central incisor/width of central incisor was revealed as reversed correlation(r=-.250, p<0.05) on smiling. 2.There was correlation between the gingival exposure and the facial height(r=.351, p<0.01), the lower facial height(r=.454, p<0.01) and the upper lip height(r=.274, p<0.01) upon smiling. 3.There was correlation between the gingival exposure and the ratio of the facial height/facial width(r=.358, p<0.05), the ratio of the upper facial height/facial width(r=.214, p<0.05), and the ratio of the lower facial height/facial height(r=.383, p<0.01) upon smiling. 4.The equation of the regression analysis for gingival exposure upon smiling could be estimated as gingival exposure upon smiling=-5.139+.279${\times}$lower facial height-.615${\times}$maxillary central incisal length-.05${\times}$nasolabial angle. Conclusions : Considering these results, it recommended that treatment planning should be designed in consideration of such factors as the length of maxillary central incisor, facial height, upper lip height and lower facial height, in order to promote the easthetic problems of face on smiling.

A Study for the development of the Korean orthodontic bracket (한국형 교정치료용 Bracket의 개발에 관한 연구)

  • Chang, Young-Il;Yang, Won-Sik;Nahm, Dong-Seok;Moon, Seong-cheol
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.565-578
    • /
    • 2000
  • The aim of this study was development of the Straight-Wire Appliance(SWA) suitable lot the treatment or Korean. To accomplish the object of this study, Korean adult with normal occlusion were selected with following criteria : 1) no functional abnormality in the craniofacial area, 2) good dental arch form and posterior occlusal relationship, 3) Angle Class I occlusal relationship, 4) no experience of orthodontic, nor prosthodontic treatment, especially, no dental treatment on labial and buccal surfaces of teeth, 5) good racial profile. Impression were taken for upper and lower dental arches or the selected normal occlusion samples and the orthodontic dental stone models were fabricated. 5 well-trained orthodontists had examined the acquired dental stone models to select study samples which satisfy the Six keys to optimal occlusion of Andrews. 155 pairs of dental stone models (92 pairs of Male, 63 of Female) were finally selected. 3 dimensional digitization were performed with the Coordinate Measuring Machine(CMM, MPC802, WEGU-Messtechnik, Germany) and measuring of Angulation, Inclination, In-and-Out, Molar offset angle and Arch form were accomplished with a measuring software to achieve data for the development of SWA. Before the measurement, error study was performed on the 3 dimensional digitization with CMM, and the analysis of reliability of computerized measuring method adapted in this study and conventional manual method Presented by Andrews was performed. Results of this study were as to)lows : 1. Equi-distance digitization with mesh size 0.25 mm, 0.5 mm and 1.0 mm were acceptable in 3 dimensional digitization of dental stone model with the CMM, and the digitization with 1.0 mm mesh size was recommendable in terms of efficiency. 2. Computerized measuring method with 3 dimensional digitization was more reliable than manual measuring method of Andrews. 3. Data were collected for the development of SWA suitable for the morphological characteristics of Korean with the computerized measuring method with 3 dimensional digitization.

  • PDF

Comparison of crown designs of different dental occupational groups, using CAD-CAM (CAD-CAM을 이용하여 디자인한 금관의 치과 직업군에 따른 형태 비교)

  • Kim, TaeHyeon;Kim, Jong-Eun;Lee, Ah-Reum;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.234-238
    • /
    • 2016
  • Purpose: Increasing use of computer aided design-computer aided manufacturing (CAD-CAM) system and number of design software made design of restoration easy and quick. Outcome of restoration has been dependent on dental technician's wax up proficiency, dentists can design restoration for themselves now. This study aims to investigate the outcome of restoration designs, according to handling skill of CAD-CAM design tool. Materials and methods: A patient's mandibular right 1st molar was prepared. After taking impression, stone model was made, scanned the stone model with 3 shape intra-oral scanner, stereolithography (STL) file was extracted. With 3shape dental designer, one dental technician with more than 5 years work experience (designer 0) and three dental technicians with less than 2years work experience (designer 1, 2, 3-group DT) and 4 1st year residents (designer 4, 5, 6, 7-group RT) designed gold crown on the same STL file. Designed crown's MD (mesio-distal) and BL (bucco-lingual) diameter, height of crown, inter-cuspal distance, number of occlusal contact points were compared. Statistical analysis was carried out, test of normality within each group, using independent t-test. Number of contact points were compared, using Wilcoxon signed-rank test. Results: There was no significant difference between group DT and group RT. Number of contact points also resulted in no significant difference. Conclusion: The outcome of each designed crowns showed no statistical differences, in values which can be expressed as numbers. Subjective factors were different. With increasing proficiency in handling designing software, fabrication of restorations according to each designer's occlusal concept can be made easy.

The effect of screw tightening techniques on the detorque value in internal connection implant superstructure (내부연결 임플란트 상부구조물에서 나사조임술식이 풀림토크값에 미치는 영향)

  • Choi, Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.243-250
    • /
    • 2010
  • Purpose: This study evaluated the effect of different screw tightening sequences and methods on detorque values in a well-fitting implant superstructure. Materials and methods: A fully edentulous mandibular master model and a metal framework directly connected to four parallel implants (Astra Tech) with a passive fit to each other were fabricated. Six stone casts were made with a splinted impression technique to represent a 'well-fitting' situation with the metal framework. Detorque values were measured twice after screw tightening using 20 Ncm. Detorque values and minimum detorque values for three screw tightening sequences (1-2-3-4, 2-4-3-1, and 2-3-1-4) and for two tightening methods (two-step and one-step) were analyzed using multi-way analysis of variance and two-way analysis of variance, respectively, at a .05 level of significance. Results: The mean detorque values for screw tightening sequences ranged from 12.8 Ncm (2-4-3-1) to 13.1 Ncm (2-3-1-4), and for screw tightening methods were 13.1 Ncm (two-step) and 11.8 Ncm (one-step). The mean of mimimum detorque values for screw tightening sequences were 11.1 Ncm (1-2-3-4) and 11.2 Ncm (2-4-3-1 and 2-3-1-4), and for screw tightening methods were 11.2 Ncm (two-step) and 9.9 Ncm (one-step). No statistically significant differences among three screw tightening sequences were found for detorque values and for mimimum detorque values. But, statistically significant differences between two screw tightening methods were found for two values. Two-step screw tightening method showed higher detorque value (P = .0003) and higher minimum detorque value (P = .0035) than one-step method. Conclusion: Within the limitations of this study, the screw tightening sequence was not a critical factor for the detorque values in a well-fitting implant superstructure by the splinted impression technique. But, two-step screw tightening method showed greater detorque values than one-step method.

Detorque values of abutment screws in a multiple implant-supported prosthesis (다수 임플란트 지지 보철물에서 지대주 나사의 풀림 토크값에 대한 연구)

  • Lee, Ju-Ri;Lee, Dong-Hwan;Hwang, Jae-Woong;Choi, Jung-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.280-286
    • /
    • 2010
  • Purpose: This study evaluated the detorque values of screws in a multiple implant-supported superstructure using stone casts made with 2 different impression techniques. Material and methods: A fully edentulous mandibular master model and a metal framework directly connected to four implants (Br${\aa}$nemark $System^{(R)}$; Nobel Biocare AB) with a passive fit to each other were fabricated. Six experimental stone casts (Group 1) were made with 6 non-splinted impressions on a master cast and another 6 experimental casts (Group 2) were made with 6 acrylic resin splinted impressions. The detorque values of screws ($TorqTite^{(R)}$ GoldAdapt Abutment Screw; Nobel Biocare AB) were measured twice after the metal framework was fastened onto each experimental stone cast with 20 Ncm torque. Detorque values were analyzed using the mixed model with the fixed effect of screw and reading and the random effect of model for the repeated measured data at a .05 level of ignificance. Results: The mean detorque values were 7.9 Ncm (Group 1) and 8.1 Ncm (Group 2), and the mean of minimum detorque values were 6.1 Ncm (Group 1) and 6.5 Ncm (Group 2). No statistically significant differences between 2 groups were found and no statistically significant differences among 4 screws were found for detorque values. No statistically significant differences between 2 groups were also found for minimum detorque values. Conclusion: In a multiple external hexagon implant-supported prosthesis, no significant differences between 2 groups were found for detorque values and for minimum detorque values. There seems to be no significant differences in screw joint stability between 2 stone cast groups made with 2 different impression techniques.

Selection of all ceramic crown (완전 도재관의 선택)

  • Lee, Seung-Kyu
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.24 no.2
    • /
    • pp.122-133
    • /
    • 2015
  • The requirements for the successful treatment of all-ceramic restorations are not so different from the ones of conventional restorations. "The provisional restoration followed by an adequate tooth reduction" and "the accurately fitting prostheses with corresponding to final impression" can be the examples of them. Nevertheless, the one which all-ceramic restorations are distinguished from conventional restorations is the additional procedure of so called "bonding". In addition to the application of resin cement between "inner surface of restoration and outer surface of abutment", bonding technology can be also applied to the treatment process of "Post and Core" in particular if the abutments are non-vital teeth. Core build-up for all-ceramic crown is conducted with fiber post and tooth colored composite by considering the properties of the restorations transmitting light. We know well that a vital abutment is easier than a non-vital one to get the targeted goals for clinical success in connection with esthetics and structure. The creation of "Post and Core" with bonding technique is a decisive factor for a long-term success if the abutment is non-vital tooth with dentinal collapse. I would like to share my clinical experience about "post & core build-up and all-ceramic restoration bonding" out of several success strategies of all-ceramic crown with this review article.

STRAIN CHANGES OF ACRYLIC RESIN SPECIMENS CURED BY THREE CURING CYCLES

  • Kang, In-Ho;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.3
    • /
    • pp.236-245
    • /
    • 2002
  • The acrylic resin was first introduced as denture base materials in 1937 and it is commonly used for denture base fabrication nowadays. Three different curing cycles (Conventional curing cycle, short curing cycle and long curing cycle) and three commercially available heat-activated acrylic resins (Vertex RS, Lucitone 199 and ProBase Hot) were investigated to find the curing cycle and material that showed the minimum shrinkage of the resin during polymerization process. A brass master mold was fabricated and duplicated by additional silicone impression material. Stone molds were made by pouring of type III dental stone (SILKY-ROCK YELLOW, Whip-Mix, Louisville, Kentucky). It was embedded in the flask. Strain gauge and thermocouple were embedded in the specimen. Strain gauge and thermocouple were connected to signal conditioning amplifier and data was recorded by pre-programmed software. The parameters ESmax (Maximum expansion strain), Sb (Strain measured just before deflasking procedure), Sa (Strain measured just after deflasking procedure) and Sf (Strain measured at the end of the experiment) were measured. ${\Delta}$S was calculated from Sb and Sa (${\Delta}$S=Sb-Sa). In the experiment concerned about materials, the parameters 90-ESmax (Maximum expansion strain measured during early 90 minutes of curing procedure), 180-ESmax (Maximum expansion strain measured from 90 minutes to 180 minutes), Sb, Sa, ${\Delta}$S and Sf were measured and the following conclusions were made. 1. The ESmax value of conventional curing cycle showed the largest value and the 180-ESmax value of Lucitone 199 showed the smallest value. 90-ESmax values showed no significant difference (p<0.05). 2. ${\Delta}$S values of conventional curing cycle showed the positive values. ${\Delta}$S values of short curing cycle and long curing cycle showed the negative values. All three materials cured by conventional curing cycle showed the positive values. 3. The Sf values of long curing cycle and ProBase Hot (cured by conventional curing cycle) showed the smallest values.

Comparative observations of lingualized occlusion and monoplane occlusion in the treatment of severe atrophy of edentulous mandible (심한 하악 치조골 흡수를 보이는 환자에서 설측 교두 교합과 단일평면 교합을 비교 관찰한 의치 수복 증례)

  • Ahn, Gyo-zin;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.127-136
    • /
    • 2018
  • The patient who has severely absorbed residual ridges, treatments are challenging to satisfy many factors: support, retention, stability, etc. The neutral zone or monoplane occlusion with non-anatomical tooth would be helpful to get additional retention and stability. The monoplane occlusion has been used long time because it can eliminate horizontal forces and many other advantages. The lingualized occlusion was introduced to improve chewing efficiency and esthetics. But from a stability aspect, it seems controversy between monoplane occlusion and lingualized occlusion. This case report shows the results of the treat two flat residual ridge patients using functional impression; piezography, and made 2 other dentures with monoplane and lingualized occlusion that patient can select denture.

Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading

  • Kim, Seong-Beom;Yun, Pil-Young;Kim, Sang-Yun;Yi, Yang-Jin;Kim, Ji-Yun;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.5
    • /
    • pp.396-403
    • /
    • 2016
  • PURPOSE. Early loading of implant can be determined by excellent primary stability and characteristic of implant surface. The implant system with recently improved surface can have load application 4-6 weeks after installing in maxilla and mandible. This study evaluated the effect of healing period to the stability of hydrophilic tapered-type implant at maxillary posterior area. MATERIALS AND METHODS. This study included 30 patients treated by hydrophilic tapered-type implants (total 41 implants at maxilla) and classified by two groups depending on healing period. Group 1 (11 patients, 15 implants) was a control group and the healing period was 12 weeks, and Group 2 (19 patients, 26 implants) was test group and the healing period was 6 weeks. Immediately after implant placement, at the first impression taking, implant stability was measured using Osstell Mentor. The patients also took periapical radiographs after restoration delivery, 12 months after restoration and final followup period. The marginal bone loss around the implants was measured using the periapical radiographs. RESULTS. All implants were survived and success rate was 97.56%. The marginal bone loss was less than 1mm after 1 year postoperatively except the one implant. The stabilities of the implants were not correlated with age, healing period until loading, insertion torque (IT), the diameter of fixture and the location of implant. Only the quality of bone in group 2 (6 week) was correlated with the stability of implant. CONCLUSION. Healing period of 6 weeks can make the similar clinical prognosis of implants to that of healing period of 12 weeks if bone quality is carefully considered in case of early loading.

THE COMPARATIVE STUDY FOR OCCLUSAL PLANE BETWEEN ARTICULATED CAST MODEL AND CEPHALOGRAM IN ORTHOGANTIHIC SURGERY PATIENTS (악교정수술 환자에서 교합기 석고 모형과 측면두부방사선사진의 교합평면에 관한 비교 연구)

  • Seo, Kyung-Suk;Park, Mi-Hwa;Lee, Ju-Hyun;Kim, Chul-Hwan;Chae, Jong-Moon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.4
    • /
    • pp.239-244
    • /
    • 2003
  • The common errors in preoperative treatment plan for the orthognathic surgery can be occurred during cast impression, cast mounting procedure with face-bow transfer, surgical stent fabrication, and so on. One of the most common errors exists during mounting process of the model on the articulator. Accurate mounting of dental casts to articulator should be achieved by transferring the 3-dimensional spatial relationship of the maxillary arch to an articulator. A face-bow is used for transfer this relationship to articulator, usually by relating the face-bow to a plane of reference of maxillary cast. The purpose of this study is evaluation of the accuracy of face-bow transferring of maxillary model to the articulator. The maxillary casts of thirty patients for orthognathic surgery were mounted on articulator with an face-bow instrument. The relationship of occlusal plane angle to Frankfort horizontal plane relations were compared the cephalogram with the cast-mounted articulator. As a result of this study, the significant difference between the maxillary occlusal planes angle in the cephalogram and articulator were found. The results were followed, 1. The mean occlusal plane angle in cast-mounted articulator was $13.5^{\circ}\;(SD{\pm}5.4)$. 2. The mean occlusal plane angle in cephalogram was $10.4^{\circ}\;(SD{\pm}4.3)$. 3. The mean difference of occlusal plane angle between cast-mounted articulator and cephalogram was $3.3^{\circ}\;(SD{\pm}4.6)$. According to the result, we should suggest that the occlusal plane angle to Frankfort plane in cast-mounted articulator is more steeper than that of cephalogram. And then, maxillofacial surgeon should try to get a more predictable result by suggesting the proper correction method and mounting the cast accurately.