Supply Route Analysis and Performance Evaluation of Dental High-Speed Air Turbine Handpiece (치과용 고속 에어터빈 핸드피스의 공급관로 분석 및 성능평가)

  • Han, Myung-Chul;Kim, Jung-Kwan;Choi, Myoung-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.1
    • /
    • pp.80-88
    • /
    • 2011
  • The dental high-speed air turbine handpiece is one of the most popular devices that have been widely used as the main means of cutting tooth structure and restorative material in dentistry. In consideration of usage and marketability of the dental handpiece, it is obviously worthy of investigating it. The goal of this paper is to establish the relationship between the air turbine speed and the supply route inside the handpiece. To do this, the Computational Fluid Dynamics(CFD) tool, Fine$^{TM}$/Turbo is used and the optimal supply route position is suggested from the simulation results. In addition, as an attempt for domestic product, the reverse engineering process of a high speed dental handpiece by 3D X-Ray CT equipment and wire cutting is presented for the Mark II model in NSK. In doing so, the 3D modeling of the handpiece parts is carried out with CATIA V5, and the interference between parts is examined. Finally, the result of performance test for the prototype produced in this research is presented.

Numerical Analysis on Performance of Dental Air Turbine Handpiece for Various Reflection Angles of Turbine Rotor (터빈 로터 반사각에 따른 의료용 에어터빈 핸드피스의 성능에 관한 수치 해석)

  • Lee, Jeong-Ho;Lee, Sang-Do;Kim, Kui-Soon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.29-32
    • /
    • 2008
  • Dental high-speed air turbine handpieces have been used as a dental cutting tool in clinical dentistry for over 50 years, yet little study has been reported on their flow and performance analysis. Therefore it is necessary to investigate turbine for the performance improvements of an air turbine handpiece. This paper presents pressure on turbine rotor and flow analysis in air turbine handpiece using CFD (computational fluid dynamics). Characteristics on each flow and pressure for four various reflection angles of turbine rotor are presented, and then performance change is analyzed about air turbine handpieces by CFD results.

  • PDF

Design of Air Turbine and Air Bearing for Dental Handpiece

  • Hwang, Pyung;Park, Sang-Shin;Sohn, Jeong-L.;Kwon, Seong-In;Kim, Do-Hyung;Kim, Woo-Seok
    • Tribology and Lubricants
    • /
    • v.23 no.5
    • /
    • pp.240-247
    • /
    • 2007
  • The design process of the dental handpiece is described. The parameters of the high speed air turbine are estimated. The effect of supply hole on the stiffuess and damping of the air bearing for handpiece is studied numerically. The Reynolds equation is solved by using the divergence formulation and the perturbation method. The test rig is built and the test procedure is developed for the turbine rotational speed measurement by using Fourier transform of noise generated by the turbine during steady operation.

NUMERICAL ANALYSIS OF INTERNAL CHARACTERISTICS ON DENTAL HIGH-SPEED AIR TURBINE HANDPIECE (의료용 고속 에어터빈 핸드피스의 내부 유동특성에 대한 수치해석)

  • Ryu, K.J.;Youn, D.H.;Baek, J.H.;Lee, D.W.;Kim, D.Y.;Kim, D.Y.;Song, D.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.535-542
    • /
    • 2011
  • To utilizing CFX V12.0.l, internal flow characteristics of denture high-speed air turbine hand-piece unit was identified, in order to analyze the performance of the torque values were compared. In order to find out the difference of torque by mash values, under steady condition, performed grid convergence test. It compared theoretical torque with torque through flow analysis. To describe the motion of turbine blade was used to immerged solid method. Depending on the location of the turbine blade were calculated from five case. Maximum and minimum values of turbine blades was analyzed. To analyze the performance of the torque values were compared with speed of turbine blade.

  • PDF

Numerical Study on the Effect of Turbine Blade Shape on Performance Characteristics of a Dental Air Turbine Handpiece (터빈 블레이드 형상에 따른 의료용 에어터빈 핸드피스의 성능 특성에 관한 수치적 연구)

  • Lee, Jeong-Ho;Kim, Kui-Soon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.1
    • /
    • pp.34-42
    • /
    • 2009
  • High-speed air turbine handpieces have been used as a dental cutting tool in clinical dentistry for over 50 years, but little study has been reported on their performance analysis. Therefore, the effect of turbine blade shape on performance characteristics of dental air turbine handpiece were studied using CFD in this paper. Computations have been performed for five different positions of turbine blade by using frozen rotor method that is one of steady-state method. The characteristics of turbine blade for shapes and reflection angles were analyzed. As a result of the computation, torque is increased by increasing the reflection angle of turbine blade.

Subcutaneous Emphysema and Pneumomediastinum After Mandibular Third Molar Extraction: a Case Report (하악 제3대구치 발치 후 병발된 피하기종과 종격동 기종: 증례보고)

  • Kim, Duk-Sil;Kim, Sung-Wan;Byun, Kyung-Hwan;Kim, Hyun-Su
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.597-599
    • /
    • 2010
  • Subcutaneous emphysema and pneumomediastium is a relatively uncommon phenomenon. Most case of pneumomediastium are caused by iatrogenic injury on the cervical region and chest during tracheostomy. It is also well known that emphysema may occur secondary to dental treatment using high-speed air turbine handpiece, but there have been few cases of emphysema extended to involving the mediastinum. These complications are reported to occur mainly in patients after dental procedures, in particular during mandibular third molar extraction. Early recognition and conservative treatment of these problems is essential in preventing life-threatening complications such as airway obstruction, mediastinitis, pneumothorax and cardiac failure. As we report a case of 25-year-old woman with subcutaneous emphysema and pneumomediastium after mandibular third molar extraction using high-speed air turbine handpiece.

A study on the usage satisfaction of multi-type handpieces with equipped air-jet function (Air-jet기능을 장착한 멀티형 복합유닛 핸드피스의 사용 만족도 조사)

  • Kim, Im-Sun;Choi, Byung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.37 no.3
    • /
    • pp.169-178
    • /
    • 2015
  • Purpose: This study was to investigate usage satisfaction of multi type handpiece with equipped air-jet function Methods: The subjects of this study through the survey was conducted for fifty-nine dental technicians in Daegu and Gyeongsangbukdo from the May 7 to 19, after the June 23 to July 4 2014. The survey was about the function and quality through user testing environment by cutting zirconia specimens using appliance for zirconia. The collected date was analyzed by the statistical program SPSS Win Ver 19.0 for the satisfaction of handpiece and control system. To test for significance on each item, p<0.05 had been decided a standard. General characteristics and relationship between the handpiece and control system was performed correlation analysis. Results: The results of this study is as follows. 35 dental technicians had 1~2 years career in zirconia part as the highest 59.3%, 95% of subjects expected that the prospects for the zirconia material have bright prospects. The satisfaction of multi type handpiece and control system design and function showed a significant difference. Subjects satisfied with the design and function of the multi type showed negative correlation with those of Standard. The satisfaction of multi type handpiece showed 3.37 points of air jet, 3.05 points of noise level, 2.69 points of water flow rate, and 1.98 points of cruise function. Sample differences in all parameters showed a statistically higher difference. Conclusion: High-speed cutting mechanism of multi-type is recommended working with zirconia materials and the multi-type unit combined handpiece motor, air-turbine and air-gun will be expected the increase of user due to the high satisfaction of air jet.

Subcutaneous Emphysema and Pneumomediastinum during Extraction of Maxillary Third Molar: A Case Report

  • Jung, Da-Woon;Yoon, Hyun-Joong;Lee, Sang-Hwa
    • Journal of Korean Dental Science
    • /
    • v.7 no.1
    • /
    • pp.25-30
    • /
    • 2014
  • Subcutaneous emphysema and pneumomediastinum is a relatively uncommon phenomenon. It may occur secondary to dental treatment using high-speed air turbine handpieces, especially after extraction of tooth. Subcutaneous emphysema is often limited only to the areas of head and neck, but also can involve deeper structures. Thorough examination and conservative treatment of these problems are essential in preventing life-threatening complications such as airway obstruction and mediastinitis. The subject of this report is a 57-year-old woman with subcutaneous emphysema and pneumomediastinum during the extraction of maxillary third molar using high-speed air turbine handpiece. If there isn't any appropriate measure, severe complications may occur. Therefore it is important to be well-informed of proper diagnosis and treatment. This article shall present a case report with literature review.